ScientificWorldJournal ; 2017: 9690704, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28740857

RESUMO

Hydrogen-sulfide (H2S) is a molecule of small dimensions typically present in the odor emissions from different plants. The European Standard EN 13725:2003 set a maximum storage time allowed of 30 hours, during which the sampling bag has to maintain the mixture of odorants with minimal changes. This study investigates the H2S losses through Nalophan bags and it shows that nonnegligible losses of H2S can be observed. The percent H2S loss after 30 hrs with respect to the initial concentration is equal to 33% ± 3% at a relative humidity of 20% and equal to 22% ± 1% at a relative humidity of 60%. The average quantity of adsorbed H2S at 30 h is equal to 2.17 105 gH2S/gNalophan at a storage humidity of 20% and equal to 1.79 105 gH2S/gNalophan at a storage humidity of 60%. The diffusion coefficients of H2S through Nalophan, for these two humidity conditions tested, are comparable (i.e., 7.5 10-12 m2/sec at 20% humidity and 6.6 10-12 m2/sec at 60% humidity).


Assuntos
Umidade , Sulfeto de Hidrogênio/análise , Polietilenotereftalatos , Adsorção , Difusão
2.
Sensors (Basel) ; 17(4)2017 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-28379190

RESUMO

Indoor air quality influences people's lives, potentially affecting their health and comfort. Nowadays, ventilation is the only technique commonly used for regulating indoor air quality. CO2 is the reference species considered in order to calculate the air exchange rates of indoor environments. Indeed, regarding air quality, the presence of pleasant or unpleasant odours can strongly influence the environmental comfort. In this paper, a case study of indoor air quality monitoring is reported. The indoor field tests were conducted measuring both CO2 concentration, using a photoacoustic multi-gas analyzer, and odour trends, using an electronic nose, in order to analyze and compare the information acquired. The indoor air monitoring campaign was run for a period of 20 working days into a university room. The work was focused on the determination of both CO2 and odour emission factors (OEF) emitted by the human activity and on the evaluation of the odour impact in a naturally ventilated room. The results highlighted that an air monitoring and recycling system based only on CO2 concentration and temperature measurements might be insufficient to ensure a good indoor air quality, whereas its performances could be improved by integrating the existing systems with an electronic nose for odour detection.


Assuntos
Odorantes/análise , Ventilação
3.
Sensors (Basel) ; 16(9)2016 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-27657086

RESUMO

Despite initial enthusiasm towards electronic noses and their possible application in different fields, and quite a lot of promising results, several criticalities emerge from most published research studies, and, as a matter of fact, the diffusion of electronic noses in real-life applications is still very limited. In general, a first step towards large-scale-diffusion of an analysis method, is standardization. The aim of this paper is describing the experimental procedure adopted in order to evaluate electronic nose performances, with the final purpose of establishing minimum performance requirements, which is considered to be a first crucial step towards standardization of the specific case of electronic nose application for environmental odor monitoring at receptors. Based on the experimental results of the performance testing of a commercialized electronic nose type with respect to three criteria (i.e., response invariability to variable atmospheric conditions, instrumental detection limit, and odor classification accuracy), it was possible to hypothesize a logic that could be adopted for the definition of minimum performance requirements, according to the idea that these are technologically achievable.

4.
Sensors (Basel) ; 16(10)2016 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-27754437

RESUMO

The electronic nose is able to provide useful information through the analysis of the volatile organic compounds in body fluids, such as exhaled breath, urine and blood. This paper focuses on the review of electronic nose studies and applications in the specific field of medical diagnostics based on the analysis of the gaseous headspace of human urine, in order to provide a broad overview of the state of the art and thus enhance future developments in this field. The research in this field is rather recent and still in progress, and there are several aspects that need to be investigated more into depth, not only to develop and improve specific electronic noses for different diseases, but also with the aim to discover and analyse the connections between specific diseases and the body fluids odour. Further research is needed to improve the results obtained up to now; the development of new sensors and data processing methods should lead to greater diagnostic accuracy thus making the electronic nose an effective tool for early detection of different kinds of diseases, ranging from infections to tumours or exposure to toxic agents.

5.
ScientificWorldJournal ; 2014: 214190, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25506608

RESUMO

The ammonia loss through Nalophan bags has been studied. The losses observed for storage conditions and times as allowed by the reference standard for dynamic olfactometry (EN 13725:2003) indicate that odour concentration values due to the presence of small molecules may be significantly underestimated if samples are not analysed immediately after sampling. A diffusion model was used in order to study diffusion through the bag. The study discusses the effect of concentration gradient (ΔC) across the polymeric membrane of the analyte. The ΔC was controlled by using a setup bag called "double bags." Experimental data show a reduction of ammonia percentage losses due to the effect of the external multibarrier. The expedient of the double bag loaded with the same gas mixture allows a reduced diffusion of ammonia into the inner bag. Comparing the inner bag losses with those of the single bag stored in the same conditions (T, P, u) and with equal geometrical characteristics (S/V, z), it was observed that the inner bag of the double bag displays a 16% loss while the single bag displays a 37% loss. Acting on the ΔC it is possible to achieve a gross reduction of 57% in the ammonia leakage due to diffusion.


Assuntos
Amônia/análise , Polietilenotereftalatos/química , Difusão , Fatores de Tempo
6.
Water Sci Technol ; 69(3): 486-94, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24552718

RESUMO

The aim of the work is to verify the diffusion rate of ammonia through the Nalophan™ film that constitutes the sampling bag, considering storage times ranging from 1 to 26 h. The ammonia decay over time was evaluated using gas-chromatography for the quantification of ammonia concentration inside the bag. The research assesses the roles of both of ammonia and water concentration gradients at the polymeric film interface on the diffusion process. The results show that both the ammonia concentration gradient and, in a less pronounced way, the water concentration gradient are the main 'engines' of ammonia diffusion. Double bags seem to represent a simple solution for preventing ammonia losses during storage. Another interesting result concerns the role of the bag surface on the ammonia diffusion rate: the higher the surface/volume (S/V) ratio, the higher the ammonia diffusion rate through the polymeric film.


Assuntos
Amônia/química , Polietilenoglicóis/química , Difusão , Polietilenotereftalatos
7.
Langmuir ; 26(20): 15814-23, 2010 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-20866034

RESUMO

The rheology of cement pastes can be controlled by polymeric dispersants such as branched polyelectrolytes that adsorb on the surfaces of silicate particles. In the present work, we analyze the adsorption behavior of ad hoc-prepared end-carboxylated poly(ethylene glycol), or PEG, on CaCO(3) particles as a model of cement in an early hydration stage. The experimental adsorption isotherms form the base of a theoretical study aimed at unraveling polymer conformational aspects of adsorption. The study was carried out with Monte Carlo simulations using a coarse-grained bead-and-spring model of linear end-charged polymer chains adsorbing on a flat, continuous, uniformly charged surface. The adsorption driving force was introduced by a Debye-Hückel electrostatic screened potential to describe the interaction between the negatively charged end group of PEG and the positively charged CaCO(3) surface empirically. With a suitable length-scale conversion between real PEG and the coarse-grained model, the calculated and experimental adsorption isotherms can be semiquantitatively compared. The theoretical results reproduce the fundamental aspects of polymer adsorption, in essential agreement with analytical approaches relating the isotherm shape to the polymer conformational properties. The conformational transition mushroom-brush of the adsorbed polymer is located on the isotherm and is related to the molecular shape. The solvent quality effect and the solution ionic strength are also considered, and their implications on the isotherms are discussed.


Assuntos
Carbonato de Cálcio/química , Modelos Moleculares , Método de Monte Carlo , Polietilenoglicóis/química , Adsorção , Concentração Osmolar , Solventes/química , Propriedades de Superfície
8.
Cancers (Basel) ; 10(4)2018 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-29670060

RESUMO

Prostate cancer is the second most common cause of cancer death among men. It is an asymptomatic and slow growing tumour, which starts occurring in young men, but can be detected only around the age of 40–50. Although its long latency period and potential curability make prostate cancer a perfect candidate for screening programs, the current procedure lacks in specificity. Researchers are rising to the challenge of developing innovative tools able of detecting the disease during its early stage that is the most curable. In recent years, the interest in characterisation of biological fluids aimed at the identification of tumour-specific compounds has increased significantly, since cell neoplastic transformation causes metabolic alterations leading to volatile organic compounds release. In the scientific literature, different approaches have been proposed. Many studies focus on the identification of a cancer-characteristic “odour fingerprint” emanated from biological samples through the application of sensorial or senso-instrumental analyses, others suggest a chemical characterisation of biological fluids with the aim of identifying prostate cancer (PCa)-specific biomarkers. This paper focuses on the review of literary studies in the field of prostate cancer diagnosis, in order to provide an overview of innovative methods based on the analysis of urine, thereby comparing them with the traditional diagnostic procedures.