RESUMO
Clinical applications of cone-beam breast CT(CBBCT) are hindered by relatively higher radiation dose and longer scan time. This study proposes sparse-view CBBCT, i.e. with a small number of projections, to overcome the above bottlenecks. A deep learning method - conditional generative adversarial network constrained by image edges (ECGAN) - is proposed to suppress artifacts on sparse-view CBBCT images reconstructed by filtered backprojection (FBP). The discriminator of the ECGAN is the combination of patchGAN and LSGAN for preserving high frequency information, with a modified U-net as the generator. To further preserve subtle structures and micro calcifications which are particularly important for breast cancer screening and diagnosis, edge images of CBBCT are added to both the generator and the discriminator to guide the learning. The proposed algorithm has been evaluated on 20 clinical raw datasets of CBBCT. ECGAN substantially improves the image qualities of sparse-view CBBCT, with a performance superior to those of total variation (TV) based iterative reconstruction and FBPConvNet based post-processing. On one CBBCT case with the projection number reduced from 300 to 100, ECGAN enhances peak-signal-to-noise ratio (PSNR) and structural similarity (SSIM) on FBP reconstruction from 24.26 and 0.812 to 37.78 and 0.963, respectively. These results indicate that ECGAN successfully reduces radiation dose and scan time of CBBCT by 1/3 with only small image degradations.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Algoritmos , Mama , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios XRESUMO
PURPOSE: Coronavirus disease 2019 (COVID-19) has become a global pandemic and is still posing a severe health risk to the public. Accurate and efficient segmentation of pneumonia lesions in computed tomography (CT) scans is vital for treatment decision-making. We proposed a novel unsupervised approach using a cycle consistent generative adversarial network (cycle-GAN) which automates and accelerates the process of lesion delineation. METHOD: The workflow includes lung volume segmentation, healthy lung image synthesis, infected and healthy image subtraction, and binary lesion mask generation. The lung volume was first delineated using a pre-trained U-net and worked as the input for the following network. A cycle-GAN was trained to generate synthetic healthy lung CT images from infected lung images. After that, the pneumonia lesions were extracted by subtracting the synthetic healthy lung CT images from the infected lung CT images. A median filter and k-means clustering were then applied to contour the lesions. The auto segmentation approach was validated on three different datasets. RESULTS: The average Dice coefficient reached 0.666 ± 0.178 on the three datasets. Especially, the dice reached 0.748 ± 0.121 and 0.730 ± 0.095, respectively, on two public datasets Coronacases and Radiopedia. Meanwhile, the average precision and sensitivity for lesion segmentation on the three datasets were 0.679 ± 0.244 and 0.756 ± 0.162. The performance is comparable to existing supervised segmentation networks and outperforms unsupervised ones. CONCLUSION: The proposed label-free segmentation method achieved high accuracy and efficiency in automatic COVID-19 lesion delineation. The segmentation result can serve as a baseline for further manual modification and a quality assurance tool for lesion diagnosis. Furthermore, due to its unsupervised nature, the result is not influenced by physicians' experience which otherwise is crucial for supervised methods.
Assuntos
COVID-19 , Pneumonia , COVID-19/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Pandemias , Tomografia Computadorizada por Raios X/métodosRESUMO
PURPOSE: Cone-beam CT (CBCT) has been widely utilized in image-guided radiotherapy. Planning CT (pCT)-aided CBCT scatter correction could further enhance image quality and extend CBCT application to dose calculation and adaptive planning. Nevertheless, existing pCT-based approaches demand accurate registration between pCT and CBCT, leading to limited imaging performance and increased computational cost when large anatomical discrepancies exist. In this work, we proposed a robust and fast CBCT scatter correction method using local filtration technique and rigid registration between pCT and CBCT (LF-RR). METHODS: First of all, the pCT was rigidly registered with CBCT, then forward projection was performed on registered pCT to create scatter-free projections. The raw scatter signals were obtained via subtracting the scatter-free projections from the measured CBCT projections. Based on frequency and intensity threshold criteria, reliable scatter signals were selected from the raw scatter signals, and further filtered for global scatter estimation via local filtration technique. Finally, corrected CBCT was reconstructed with the projections generated by subtracting the scatter estimation from the raw CBCT projections using FDK algorithm. The LF-RR method was evaluated via comparison with another pCT-based scatter correction method based on Median and Gaussian filters (MG method). RESULTS: Proposed method was first validated on an anthropomorphic pelvis phantom, and showed satisfied performance on scatter removal even when anatomical mismatches were intentionally created on pCT. The quantitative analysis was further performed on four clinical CBCT images. Compared with the uncorrected CBCT, CBCT corrected by MG with rigid registration (MG-RR), MG with deformable registration (MG-DR), and LF-RR reduced the CT number error from 79 ± 35 to 25 ± 18 , 17 ± 13 and 7 ± 3 HU for adipose and from 115 ± 61 to 36 ± 22 , 30 ± 24 , 7 ± 3 HU for muscle, respectively. After correction, the spatial non-uniformity (SNU) of CBCT corrected with MG-RR, MG-DR and LF-RR was 51 ± 13 , 60 ± 21 , and 21 ± 9 HU for adipose, and 50 ± 22 , 57 ± 41 , and 25 ± 6 HU for muscle, respectively. Meanwhile, the contrast-to-noise ratio (CNR) between muscle and adipose was increased by a factor of 2.70, 2.89 and 2.56, respectively. Using the LF-RR method, the scatter correction of 656 projections can be finished within 10 s and the corrected volumetric images (200 slices) can be obtained within 2 min. CONCLUSION: We developed a fast and robust pCT-based CBCT scatter correction method which exploits the local-filtration technique to promote the accuracy of scatter estimation and is resistant to pCT-to-CBCT registration uncertainties. Both phantom and patient studies showed the superiority of the proposed correction in imaging accuracy and computational efficiency, indicating promisingfuture clinical application.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Radioterapia Guiada por Imagem , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Espalhamento de RadiaçãoRESUMO
PURPOSE: Flat-panel detector (FPD) based dual-energy cone-beam computed tomography (DE-CBCT) is a promising imaging technique for dedicated clinical applications. In this paper, we proposed a fully analytical method for fast and effective single-scan DE-CBCT image reconstruction and decomposition. METHODS: A rotatable Mo filter was inserted between an x-ray source and imaged object to alternately produce low and high-energy x-ray spectra. First, filtered-backprojection (FBP) method was applied on down-sampled projections to reconstruct low and high-energy images. Then, the two images were converted into a vectorized form represented with an amplitude and an argument image. Using amplitude image as a guide, a joint bilateral filter was applied to denoise the argument image. Then, high-quality dual-energy images were recovered from the amplitude image and the denoised argument image. Finally, the recovered dual-energy images were further used for low-noise material decomposition and electron density synthesis. Imaging was conducted on a Catphan® 600 phantom and an anthropomorphic head phantom. The proposed method was evaluated via comparison with the traditional two-scan method and a commonly used filtering method (HYPR-LR). RESULTS: On the Catphan® 600 phantom, the proposed method successfully reduced streaking artifacts and preserved spatial resolution and noise-power-spectrum (NPS) pattern. In the electron density image, the proposed method increased contrast-to-noise ratio (CNR) by more than 2.5 times and achieved <1.2% error for electron density values. On the anthropomorphic head phantom, the proposed method greatly improved the soft-tissue contrast and the fine detail differentiation ability. In the selected ROIs on different human tissues, the differences between the CT number obtained by the proposed method and that by the two-scan method were less than 4 HU. In the material images, the proposed method suppressed noise by over 75.5% compared with two-scan results, and by over 40.4% compared with HYPR-LR results. Implementation of the whole algorithm took 44.5 s for volumetric imaging, including projection preprocessing, FBP reconstruction, joint bilateral filtering, and material decomposition. CONCLUSIONS: Using down-sampled projections in single-scan DE-CBCT, the proposed method could effectively and efficiently produce high-quality DE-CBCT images and low-noise material decomposition images. This method demonstrated superior performance on spatial resolution enhancement, NPS preservation, noise reduction, and electron density accuracy, indicating better prospect in material differentiation and dose calculation.