Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38719072

RESUMO

BACKGROUND: The purpose of this study is to report the minimum 5-year clinical and radiographic outcomes of patients undergoing anatomic total shoulder arthroplasty (aTSA) with a posteriorly augmented glenoid component. METHODS: Thirty-five shoulders with minimum 5-year follow-up underwent aTSA using a posteriorly augmented glenoid component for the treatment of glenohumeral osteoarthritis with posterior glenoid bone loss. Clinical outcomes included range of motion, visual analog scale (VAS) for pain, and patient-reported outcomes scores. Radiographs and computed tomography scans were obtained to assess glenoid morphology, retroversion, and central peg osseous integration via Wirth score, Lazarus scores, and Yian scores. Postoperative outcomes were measured at minimum 2- and 5-year follow-up. Kaplan-Meier survival analysis was calculated. RESULTS: Two patients experienced prosthetic instability requiring revision, leaving 33 shoulders with an average follow-up of 6.6 years. Average preoperative glenoid retroversion was 21.6°. A significant improvement in pain, range of motion, and patient-reported outcomes score was noted at minimum 2- and 5-year follow-up. In addition, VAS pain, American Shoulder and Elbow Surgeons, and Quick Disabilities of the Arm, Shoulder, and Hand scores improved between minimum 2- and 5-year follow-up. The average Lazarus and Yian scores at final follow-up were 0.73 and 2.6, respectively. There was an increase in Lazarus score and a decrease in Wirth score between 2- and 5-year follow-up. A significant correlation was identified between VAS pain scores and both Lazarus and Wirth scores. Survivorship free from revision was 92% at 8.8 years postoperatively. CONCLUSIONS: Midterm results of aTSA with a posteriorly augmented, stepped glenoid component demonstrate sustained improvements in clinical outcomes with low rates of radiographic loosening. Continued improvement in pain and function, as well as a minor progression of radiographic osteolysis, may be expected between 2- and 5-year follow-up. In addition, the severity of radiographic loosening correlates with subjective pain levels.

2.
J Shoulder Elbow Surg ; 30(12): 2786-2794, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34022366

RESUMO

BACKGROUND: Proximal humeral fractures are common injuries. Although certain fracture types may benefit from surgery including open reduction-internal fixation (ORIF), the optimal method for fixation is unclear. Newer implant designs that improve healing by minimizing hardware failure and recurrent fracture displacement may optimize clinical outcomes. METHODS: Over a 27-month period, 37 consecutive patients with proximal humeral fractures were treated by a single surgeon with a lateral humeral plate through which an intramedullary nitinol cage was inserted. Additional screws were placed through the tuberosities and cage as required. Fractures were classified by both the Neer classification and angulation or displacement in the coronal plane. At most recent follow-up, radiographic results, patient-reported outcome measurements, range of motion, complications, and reoperations were recorded. RESULTS: Thirty-one patients had a minimum of 1 year of clinical and radiographic follow-up. The average follow-up period was 91 weeks. By use of the Neer classification, there were 4 two-part, 21 three-part, and 6 four-part fractures. Twenty-one fractures were displaced in valgus and 10 in varus. Outcome measurements at most recent follow-up demonstrated an average American Shoulder and Elbow Surgeons score of 68; Single Assessment Numeric Evaluation score of 70; Quick Disabilities of the Arm, Shoulder and Hand score of 27; Veterans RAND-12 Physical Component Score of 37 and Mental Component Score of 51; Constant score of 55; Patient-Reported Outcomes Measurement Information System score of 29; and Oxford Shoulder Score of 23. Average active range of motion showed forward elevation of 134°, abduction of 91°, external rotation with the arm at the side of 30° (range, -10° to 60°), and internal rotation with the arm at the side to L1 (range, T6-S4). There were 11 complications (35%), including 2 cases of axillary nerve neurapraxia that resolved and 4 cases of avascular necrosis (13%). Unplanned reoperations were performed in 6 patients (19%). One patient underwent revision for loose hardware removal, 1 patient underwent revision ORIF after a fall, and 4 patients required component removal and revision to shoulder arthroplasty. No screw cutout or varus head collapse occurred. CONCLUSION: The management of proximal humeral fractures remains challenging. Our results demonstrate similar fracture healing, clinical improvement, and complication rates compared with conventional ORIF with screws and a side plate. At 1 year of follow-up, there were low rates of recurrent fracture displacement and screw cutout. There was a higher-than-expected rate of avascular necrosis as compared with other studies using a similar fixation construct. Larger studies and longer follow-up may demonstrate decreased rates of revision surgery and superior outcomes. Additional studies may determine whether this fixation method is superior to others for proximal humeral fractures.


Assuntos
Fixação Interna de Fraturas , Fraturas do Ombro , Placas Ósseas , Consolidação da Fratura , Humanos , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Resultado do Tratamento
3.
Arthroscopy ; 35(8): 2312-2313, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31395163

RESUMO

The arthroscopic Latarjet procedure is gaining acceptance as a procedure to treat anterior glenohumeral instability. Although complications occur, it is possible to obtain clinically meaningful results. Acquiring the skills and mastering the procedure are challenging even for expert surgeons.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Cirurgiões , Artroscopia , Humanos , Curva de Aprendizado
4.
Arthroscopy ; 35(4): 1254-1256, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30954116

RESUMO

Superior capsular reconstruction is gaining acceptance as a procedure to treat massive and irreparable superior and posterosuperior rotator cuff tears. With a paucity of clinical and no long-term data, early results suggest that superior capsular reconstruction may offer improvements in pain, range of motion, function, and validated outcome measurements.


Assuntos
Literatura Moderna , Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Amplitude de Movimento Articular , Manguito Rotador
5.
J Shoulder Elbow Surg ; 28(1): 164-169, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30082122

RESUMO

BACKGROUND: The ideal rotator cuff repair achieves high initial fixation strength and secure tendon-to-bone apposition until biological healing occurs. A suture that reacts to the local stress environment by minimizing suture laxity across the repair could theoretically maintain soft-tissue apposition to bone and therefore improve healing. METHODS: By use of an in vivo ovine shoulder model, the infraspinatus tendon was transected and then repaired with either a laxity-minimizing suture or a traditional high tensile suture. The purpose of this study was to evaluate both sutures' safety at 5 days and 6 weeks after repair. RESULTS: The macroscopic and microscopic analyses of the repair sites showed similar amounts of surgical trauma. There was no evidence of cheese wiring or tissue necrosis of the repaired tendons for either suture. There was no evidence of systematic toxicity in any animal. The maximum gap between cut edges of the tendon for repairs with the predicate suture was approximately twice the gap for the laxity-minimizing suture. CONCLUSION: The laxity-minimizing suture was as safe at 5 days and 6 weeks as the predicate suture. Neither suture contributed to local tissue damage or particle generation leading to adverse systematic consequences. An additional observation was that the maximum gap between cut edges of the tendon for repairs with the predicate suture was approximately twice the gap for the laxity-minimizing suture.


Assuntos
Teste de Materiais , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Suturas , Animais , Modelos Animais , Manguito Rotador/patologia , Ovinos
6.
Arthroscopy ; 34(10): 2808-2809, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30286880

RESUMO

Symptomatic bilateral rotator cuff tears are common. How patients compare and rate each shoulder at different time points following staged repair is variable. At a minimum of 1-year follow-up after rotator cuff repair, patients should expect similar improvement in pain and validated outcome measures for each side.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Artroplastia , Artroscopia , Humanos , Resultado do Tratamento
7.
Arthroscopy ; 32(10): 1965-1970, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27160460

RESUMO

PURPOSE: To report on the intraoperative and early postoperative (<3 months) problems and complications encountered with the arthroscopic Latarjet procedure in patients with complex anterior shoulder instability. METHODS: Between 2010 and 2014, 83 patients underwent an arthroscopic Latarjet procedure for recurrent post-traumatic anterior instability. The group's mean age was 28 ± 10 years and consisted of 76 (92%) male patients. A "problem" was defined as an unanticipated perioperative event that was not likely to affect the patient's final outcome. A "complication" was defined as an event that was likely to negatively affect outcome. RESULTS: At a mean follow-up of 17 months (range, 3 to 43 months), 20 (24%) patients sustained either a problem and/or a complication. The problem rate was 18% and the complication rate was 10%. The most commonly encountered adverse event was intraoperative fracture of the coracoid graft, which occurred in 6 patients (7%). In addition, 1 arthroscopic case was intraoperatively converted to open and 1 patient sustained a transient axillary nerve injury. A total of 7 cases underwent secondary operative procedures. The rate of problems and/or complications in primary cases was not significantly different than revision cases (P = .335). CONCLUSIONS: The rate of adverse events reported in this arthroscopic series is not insignificant and is similar to that reported with the traditional open Latarjet. With appropriate training, the arthroscopic Latarjet procedure can be effective for the management of patients with complex shoulder instability. LEVEL OF EVIDENCE: Level IV, therapeutic case series.


Assuntos
Artroscopia/efeitos adversos , Complicações Intraoperatórias/epidemiologia , Instabilidade Articular/cirurgia , Complicações Pós-Operatórias/epidemiologia , Articulação do Ombro/cirurgia , Adolescente , Adulto , Artroscopia/métodos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Ontário/epidemiologia , Fatores de Tempo , Estados Unidos , Adulto Jovem
8.
J Shoulder Elbow Surg ; 25(10): 1681-9, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27212072

RESUMO

BACKGROUND: Posterior glenoid bone loss is commonly encountered in total shoulder arthroplasty (TSA). The purpose of our study is to report the clinical and radiographic findings of patients with a minimum of 2 years' follow-up treated with an all-polyethylene, augmented glenoid component. METHODS: Twenty-two shoulders with posterior glenoid bone loss were treated by a single surgeon. All underwent primary TSA using a posteriorly augmented, all-polyethylene, stepped glenoid component. Outcome data included visual analog scale, Western Ontario Osteoarthritis of the Shoulder index, and Short Form 36 scores. Radiographic analysis was performed to evaluate bone-cement interface lucency, implant seating, and osseous integration of the central peg. RESULTS: The mean follow-up period was 36 months. Average preoperative retroversion measured with computed tomography scan was 23.5°. In addition to statistically significant increases in forward flexion and external rotation, the visual analog scale score, Western Ontario Osteoarthritis of the Shoulder score, and Short Form 36 physical component summary score all improved significantly (P < .001). Twelve shoulders had osseous integration between the central-peg flanges, 6 had bone adjacent to the central-peg flanges but without identifiable osseous integration, and 1 showed osteolysis. The mean Lazarus score was 0.5. All glenoids had perfect seating scores. Two patients sustained a total of 3 episodes of prosthetic instability. CONCLUSIONS: Early results of a posteriorly augmented, all-polyethylene, stepped prosthetic glenoid component to address posterior glenoid loss in TSA are encouraging. Continued evaluation will determine prosthetic longevity and maintained clinical improvement.


Assuntos
Prótese Articular , Osteoartrite/cirurgia , Polietileno , Articulação do Ombro/cirurgia , Adulto , Idoso , Artroplastia do Ombro/métodos , Cimentos Ósseos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Osteoartrite/diagnóstico por imagem , Medição da Dor , Desenho de Prótese , Amplitude de Movimento Articular , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Arthroscopy ; 31(11): 2183-90, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26188782

RESUMO

PURPOSE: To compare the knot characteristics of a pretied suture knot with 3 of the most commonly used arthroscopic knots tied with various high-strength sutures. METHODS: Three commonly used arthroscopic knots (surgeon's knot, Seoul Medical Center, and Duncan loop) tied with no. 2 high-strength sutures were compared with a pretied knot secured with either 1, 2, or 3 reversed half hitches (RHAPS). An orthopaedic sports medicine surgeon and fellow tied a total of 120 knots. All knot combinations were tested for strength, knot bulk, cyclic loop elongation, ultimate loop elongation, and ultimate strength. RESULTS: All pretied configurations had statistically significant improved strength (P = .048, P ≤ .001, and P < .001) versus all other knot groups with mean ± standard deviation loads of 206.3 ± 37.5, 285.6 ± 68.6, and 357.6 ± 61.1 N, respectively. The pretied knot with 1, 2, or 3 RHAPs has significantly smaller volume than the arthroscopic knots in all suture materials. All pretied knot configurations demonstrated no significant difference in cyclic loop elongation compared with standard arthroscopic knots; however, they had a statistically significant lower ultimate loop elongation (P = .001 for each pretied knot configuration). CONCLUSIONS: Compared with other commonly tied arthroscopic knots using no. 2 high-strength suture, the pretied knot with doubled no. 1 high-tensile-strength suture tied with 1, 2, or 3 RHAPs results in a statistically significantly improved strength. The pretied knot has an equivalent cyclic loop elongation and lower ultimate loop elongation with all RHAP configurations. The pretied knot with 2 or 3 RHAPs has a significantly higher ultimate strength than all combinations of arthroscopic knots excluding one. The pretied knot with 1, 2, or 3 RHAPs has significantly less knot volume than all other knots tested and offers a more reproducible knot. CLINICAL RELEVANCE: The pre-tied knot offers equivalent or improved strength while having a smaller knot volume.


Assuntos
Artroscopia/métodos , Teste de Materiais/métodos , Técnicas de Sutura/instrumentação , Suturas/normas , Desenho de Equipamento , Humanos , Resistência à Tração
11.
Orthop Traumatol Surg Res ; : 103919, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38879002

RESUMO

The Latarjet procedure is a frequently used stabilization procedure in case of anterior shoulder instability with critical glenoid bone loss and/or off-track Hill Sachs lesions. Although uncommon, intra-operative graft fractures do occur. When confronted with this potentially challenging intra-operative complication, having a secondary solution is paramount to achieve a successful outcome. This technical note provides a treatment algorithm that may function as a useful guideline to assist surgeons that experience this potentially complex unintended event during a Latarjet procedure. LEVEL OF EVIDENCE: Level IV, therapeutic case series.

12.
JSES Rev Rep Tech ; 3(1): 44-48, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37588059

RESUMO

Glenoid bone loss presents a challenging dilemma, particularly in the setting of failed arthroplasty requiring conversion to a reverse total shoulder arthroplasty (rTSA). The aim of our systematic review was to examine the success and failure of biologic glenoid bone grafting to address vault deficiencies in the setting of shoulder arthroplasty conversion to rTSA. Twelve articles were included and a complete PUBMED search. Inclusion criteria included glenoid bone grafting for conversion of failed arthroplasty and a minimum of 12 months follow-up. Exclusion criteria included grafting for primary rTSA, and re-revision for infection or humeral loosening. Failures were defined as failure of the graft to radiographically incorporate, symptomatic base plate loosening, and need for further surgical re-revision. Two hundred patients were identified across the 12 articles. Eighteen percent (36/200) of all cases demonstrated failure to radiographically incorporate. Thirteen percent (25/200) of all grafting cases required re-revision due to symptomatic failure (pain or functional deterioration). Femoral shaft demonstrated the highest failure rate at 88% (7/8). Grafting for glenoid bone loss in the setting of conversion to rTSA has an 82% rate of success across autograft and allograft utilization. Further studies are needed to better define the success of autografting versus allografting in the setting of shoulder arthroplasty conversion to rTSA with glenoid bone loss.

14.
Am J Sports Med ; 30(3): 322-8, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12016070

RESUMO

BACKGROUND: In recent years, various investigators have begun using lasers in the treatment of shoulder instability. HYPOTHESIS: Arthroscopic laser-assisted capsular shift is an effective treatment for patients with multidirectional shoulder instability. STUDY DESIGN: Retrospective cohort study. METHODS: We retrospectively identified 28 patients (30 shoulders) with multidirectional shoulder instability who were unresponsive to nonoperative management and who had undergone the laser-assisted capsular shift procedure. Twenty-five patients (27 shoulders) with an average follow-up of 28 months were available for review. All patients underwent a physical examination and completed a general questionnaire; the University of California, Los Angeles, shoulder rating scale; the Western Ontario Shoulder Instability Index; and the Short-Form 36 quality of life index. RESULTS: In 22 shoulders, results of the procedure were considered a success because the patients had no recurrent symptoms and at latest follow-up had required no further operative intervention. In five shoulders, results were considered a failure because of recurrent pain or instability and the need for an open capsular shift procedure. With recurrent instability as a measure of failure, the overall success rate was 81.5%. CONCLUSIONS: Our results with laser-assisted capsular shift are comparable with the results of other open and arthroscopic techniques in relieving pain and returning athletes to their premorbid function.


Assuntos
Artroscopia/métodos , Cápsula Articular/cirurgia , Instabilidade Articular/cirurgia , Terapia a Laser/métodos , Articulação do Ombro/cirurgia , Adolescente , Adulto , Traumatismos em Atletas/cirurgia , Criança , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Satisfação do Paciente , Amplitude de Movimento Articular , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
15.
J Am Acad Orthop Surg ; 10(1): 16-24, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11809047

RESUMO

The valgus knee presents a unique set of problems that must be addressed during total knee arthroplasty. Both bone and soft-tissue deformities complicate restoration of proper alignment, positioning of components, and attainment of joint stability. The variables that may need to be addressed include lateral femoral condyle or tibial plateau deficiencies secondary to developmental abnormalities, and/or wear; primary or acquired contracture of the lateral capsular and ligamentous structures; and, occasionally, laxity of the medial collateral ligament. Understanding the specific pathologic anatomy associated with the valgus knee is a prerequisite to selecting the proper surgical method to optimize component position and restore soft-tissue balance.


Assuntos
Artroplastia do Joelho/métodos , Deformidades Articulares Adquiridas/cirurgia , Articulação do Joelho/patologia , Artroplastia do Joelho/efeitos adversos , Humanos , Deformidades Articulares Adquiridas/etiologia , Deformidades Articulares Adquiridas/patologia
16.
Arthroscopy ; 20 Suppl 2: 208-9, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15243460

RESUMO

The author describes a technique for simplifying suture retrieval during arthroscopic procedures. During retrograde suture retrieval, it might be difficult to grasp sutures unless the suture is brought to the retrieving instrument. If the surgeon does not have an assistant with arthroscopic experience, guiding the suture to the retriever could be impossible. Using a closed-end knot pusher, the assistant can easily deliver the suture to the retriever. This technique allows even the least experienced arthroscopists to assist with suture retrieval.


Assuntos
Artroscopia/métodos , Articulação do Ombro/cirurgia , Técnicas de Sutura , Humanos , Manguito Rotador/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA