Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Ultrasonics ; 139: 107284, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458061

RESUMO

High frame rate ultrasound (US) imaging techniques in 3D are promising tools for capturing abdominal aortic aneurysms (AAAs) over time, however, with the limited number of channel-to-element connections current footprints are small, which limits the field of view. Moreover, the maximal steering angle of the ultrasound beams in transmit and the maximal receptance angle in receive are insufficient for capturing the curvy shape of the AAA. Therefore, an approach is needed towards large arrays. In this study, high frame rate bistatic 3D US data (17 Hz) were acquired with two synchronized matrix arrays positioned at different locations (multi-aperture imaging) using a translation stage to simulate what a larger array with limited channel-to-element connections can potentially achieve. Acquisitions were performed along an AAA shaped phantom with different probe tilting angles (0 up to ± 30°). The performance of different multi-aperture configurations was quantified using the generalized contrast-to-noise ratio of the wall and lumen (gCNR). Furthermore, a parametric model of the multi-aperture system was used to estimate in which AAA wall regions the contrast is expected to be high. This was evaluated for AAAs with increasing diameters and curvature. With an eight-aperture 0° probe angle configuration a 69 % increase in field of view was measured in the longitudinal direction compared to the field of view of a single aperture configuration. When increasing the number of apertures from two to eight, the gCNR improved for the upper wall and lower wall by 35 % and 13 % (monostatic) and by 36 % and 13 % (bistatic). Contrast improvements up to 22 % (upper wall) and 12 % (lower wall) are achieved with tilted probe configurations compared to non-tilted configurations. Moreover, with bistatic imaging with tilted probe configurations gCNR improvements up to 4 % (upper wall) and 7 % (lower wall) are achieved compared to monostatic imaging. Furthermore, imaging with a larger inter-probe distance improved the gCNR for a ± 15° probe angle configuration. The gCNR has an expected pattern over time, where the contrast is lower when there is more wall motion (systole) and higher when motion is reduced (diastole). Furthermore, a higher frame rate (45 Hz) yields a lower gCNR, because fewer compound angles are used. The results of the parametric model suggest that a flat array is suitable for imaging AAA shapes with limited curvature, but that it is not suitable for imaging larger AAA shapes with more curvature. According to the model, tilted multi-aperture configurations combined with bistatic imaging can achieve a larger region with high contrast compared to non-tilted configurations. The findings of the model are in agreement with experimental findings. To conclude, this study demonstrates the vast improvements in field of view and AAA wall visibility that a large, sparsely populated 3D array can potentially achieve when imaging AAAs compared to single or dual aperture imaging. In the future, larger arrays, less thermal noise, more steering, and more channel-to-element connections combined with carefully chosen orientations of (sub-) apertures will likely advance 3D imaging of AAAs.


Assuntos
Aneurisma da Aorta Abdominal , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ultrassonografia/métodos
2.
Comput Struct Biotechnol J ; 21: 4288-4300, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37701019

RESUMO

Background: To fully quantify arterial wall and plaque stiffness, acoustic radiation force impulse (ARFI)-induced wave-tracking along the entire vessel circumference is desired. However, attenuation and guided wave behavior in thin vessel walls limits wave-tracking to short trajectories. This study investigated the potential of beam-steered ARFI and wave-tracking to extend group velocity estimation over a larger proportion of the circumference compared to conventional 0° ARFI-induced wave-tracking. Methods: Seven vessel-mimicking polyvinyl alcohol cryogel phantoms with various dimensions and compositions and an ex vivo human carotid artery were imaged in a dedicated setup. For every 20° phantom rotation, transverse group wave velocity measurements were performed with an Aixplorer Ultimate system and SL18-5 transducer using 0°/20°/-20°-angled ultrasound pushes. Transmural angular wave velocities were derived along 60°-trajectories. A 360°-angular velocity map was composed from the top-wall 60°-trajectories 0°-data, averaged over all physical phantom rotations (reference). For each phantom rotation, 360°-angular velocity maps were composed using 0°-data (0°-approach) or data from all angles (beam-steered approach). Percentages of rotations with visible waves and relative angular velocity errors compared to the reference map as function of the circumferential angle were determined for both approaches. Results: Reference 360°-angular velocity maps could be derived for all samples, representing their stiffness. Beam-steering decreased the proportion of the circumference where waves were untraceable by 20% in phantoms and 10% ex vivo, mainly at 0° push locations. Relative errors were similar for both approaches (phantoms: 10-15%, ex vivo: 15-35%). Conclusion: Beam-steering enables wave-tracking along a higher proportion of the wall circumference than 0° ARFI-induced wave-tracking.

3.
Ultrasound Med Biol ; 49(3): 866-874, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36567191

RESUMO

The construct validity and reproducibility of three commonly used handheld ultrasound (US) devices in measuring carotid arterial diameter was evaluated: Telemed MicrUs EXT-1H (Telemed, Vilnius, Lithuania), Butterfly iQ (Butterfly Network, Inc., Guilford, CT, USA) and Philips Lumify (Philips Healthcare, Best, The Netherlands). An in vitro setup was built to evaluate construct validity, compared with high-end US, and intra-observer variability of handheld US devices. Handheld devices showed a mean difference of 0.023 ± 0.030 cm, 0.012 ± 0.037 cm and 0.009 ± 0.046 cm for, respectively, Telemed, Butterfly and Lumify in comparison with high-end US devices. Intraclass agreement with the high-end system as well as intra-observer variability for handheld US devices was classified as excellent, with all values greater than 0.95. Subsequently, inter-observer variability of handheld US devices was investigated in an in vivo setup with 20 healthy volunteers. Inter-observer variability was classified as excellent for Telemed (0.901), good for Lumify (0.827) and moderate for Butterfly (0.684) with a difference of, respectively, 0.005 ± 0.031 cm, 0.020 ± 0.050 cm and -0.003 ± 0.033 cm. In conclusion, handheld US devices demonstrated an excellent construct validity and intra-observer variability. Additionally, excellent-to-good inter-observer variability for Telemed and Lumify was observed, and Butterfly demonstrated a moderate inter-observer agreement. These results indicate that handheld US devices are effective for measuring carotid arterial diameter.


Assuntos
Artérias Carótidas , Artéria Carótida Primitiva , Humanos , Reprodutibilidade dos Testes , Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassom , Variações Dependentes do Observador
4.
IEEE Trans Biomed Eng ; 69(3): 1042-1051, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34324419

RESUMO

The introduction of ultrafast ultrasound and spatiotemporal filtering has significantly improved the sensitivity of Doppler ultrasound imaging. This work describes the development of a 3D power Doppler imaging technique which uses a 1D-array ultrasound probe that mechanically translates at a constant speed. The continuous translation allows for a fast scan of a large 3D volume without requiring complex hardware. The technique was realized in a prototype and its feasibility illustrated using phantom and in vivo kidney and breast lesion experiments. Although this 3D Doppler imaging technique is limited in some aspects, it enables power Doppler imaging of a large volume in a short acquisition time with less computational costs.


Assuntos
Imageamento Tridimensional , Ultrassonografia Doppler , Imageamento Tridimensional/métodos , Rim/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos
5.
Ultrasound Med Biol ; 48(11): 2335-2343, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35999121

RESUMO

Ultrasound-based local pulse wave velocity (PWV) estimation, as a measure of arterial stiffness, can be based on fast focused imaging (FFI) or plane wave imaging (PWI). This study was aimed at comparing the accuracy of in vivo PWV estimation using FFI and PWI. Ultrasound radiofrequency data of carotid arteries were acquired in 14 healthy volunteers (25-57 y) by executing the FFI (12 lines, 7200 Hz) and PWI (128 lines, 2000 Hz) methods consecutively. PWV was derived at two time-reference points, dicrotic notch (DN) and systolic foot (SF), for multiple pressure cycles by fitting a linear function through the positions of the peaks of low-pass filtered wall acceleration curves as a function of time. The accuracy of PWV estimation was determined for various cutoff frequencies (10-200 Hz). No statistically significant difference was observed between PWVs estimated by both approaches. The PWV and R2 at DN were higher, on average, than those at SF (PWV/R2: FFI SF 5.5/0.92, FFI DN 6.1/0.92; PWI SF 5.4/0.89, PWI DN 6.3/0.95). The use of cutoff frequencies between 40 and 80 Hz provided the most accurate PWVs. Both methods seemed equally suitable for use in clinical practice, although we have a preference for the PWV at DN given the higher R2 values.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Artérias Carótidas/diagnóstico por imagem , Humanos , Análise de Onda de Pulso/métodos , Sístole , Ultrassonografia/métodos
6.
Med Phys ; 36(9): 4268-76, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19810501

RESUMO

PURPOSE: Interfraction dose accumulation is necessary to evaluate the dose distribution of an entire course of treatment by adding up multiple dose distributions of different treatment fractions. This accumulation of dose distributions is not straightforward as changes in the patient anatomy may occur during treatment. For this purpose, the accuracy of nonrigid registration methods is assessed for dose accumulation based on the calculated deformations fields. METHODS: A phantom study using a deformable cubic silicon phantom with implanted markers and a cylindrical silicon phantom with MOSFET detectors has been performed. The phantoms were deformed and images were acquired using a cone-beam CT imager. Dose calculations were performed on these CT scans using the treatment planning system. Nonrigid CT-based registration was performed using two different methods, the Morphons and Demons. The resulting deformation field was applied on the dose distribution. For both phantoms, accuracy of the registered dose distribution was assessed. For the cylindrical phantom, also measured dose values in the deformed conditions were compared with the dose values of the registered dose distributions. Finally, interfraction dose accumulation for two treatment fractions of a patient with primary rectal cancer has been performed and evaluated using isodose lines and the dose volume histograms of the target volume and normal tissue. RESULTS: A significant decrease in the difference in marker or MOSFET position was observed after nonrigid registration methods (p < 0.001) for both phantoms and with both methods, as well as a significant decrease in the dose estimation error (p < 0.01 for the cubic phantom and p < 0.001 for the cylindrical) with both methods. Considering the whole data set at once, the difference between estimated and measured doses was also significantly decreased using registration (p < 0.001 for both methods). The patient case showed a slightly underdosed planning target volume and an overdosed bladder volume due to anatomical deformations. CONCLUSIONS: Dose accumulation using nonrigid registration methods is possible using repeated CT imaging. This opens possibilities for interfraction dose accumulation and adaptive radiotherapy to incorporate possible differences in dose delivered to the target volume and organs at risk due to anatomical deformations.


Assuntos
Modelos Biológicos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico , Humanos , Imagens de Fantasmas , Doses de Radiação , Neoplasias Retais/radioterapia , Reto/diagnóstico por imagem , Reto/efeitos da radiação , Silício/efeitos da radiação , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/efeitos da radiação
7.
Ultrasound Med Biol ; 45(7): 1675-1690, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31005369

RESUMO

Atherosclerotic plaque development in the carotid artery bifurcation elevates the risk for stroke, which is often initiated by plaque rupture. The risk-to-rupture of a plaque is related to its composition. Two-dimensional non-invasive carotid elastography studies have found a correlation between wall strain and plaque composition. This study introduces a technique to perform non-invasive volumetric elastography in vivo. Three-dimensional ultrasound data of carotid artery bifurcations were acquired in four asymptomatic individuals using an electrocardiogram-triggered multislice acquisition device that scanned over a length of 35 mm (350 slices) using a linear transducer (L11-3, fc = 9 MHz). For each slice, three-angle ultrasound plane wave data were acquired and beamformed. A correction for breathing-induced motion was applied to spatially align the slices, enabling 3-D cross-correlation-based compound displacement, distensibility and strain estimation. Distensibility values matched with previously published values, while the corresponding volumetric principal strain maps revealed locally elevated compressive and tensile strains. This study presents for the first time 3-D elastography of carotid arteries in vivo.


Assuntos
Artérias Carótidas/anatomia & histologia , Técnicas de Imagem por Elasticidade/métodos , Imageamento Tridimensional/métodos , Adulto , Artérias Carótidas/efeitos dos fármacos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valores de Referência , Reprodutibilidade dos Testes
8.
Ultrasound Med Biol ; 45(7): 1691-1707, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31079874

RESUMO

Visualization and quantification of blood flow are considered important for early detection of atherosclerosis and patient-specific diagnosis and intervention. As conventional Doppler imaging is limited to 1-D velocity estimates, 2-D and 3-D techniques are being developed. We introduce an adaptive velocity compounding technique that estimates the 2-D velocity vector field using predominantly axial displacements estimated by speckle tracking from dual-angle plane wave acquisitions. Straight-vessel experiments with a 7.8-MHz linear array transducer connected to a Verasonics Vantage ultrasound system revealed that the technique performed with a maximum velocity magnitude bias and angle bias of -3.7% (2.8% standard deviation) and -0.16° (0.41° standard deviation), respectively. In vivo, complex flow patterns were visualized in two healthy and three diseased carotid arteries and quantified using a vector complexity measure that increased with increasing wall irregularity. This measure could potentially be a relevant clinical parameter which might aid in early detection of atherosclerosis.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Doppler/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Carótidas/fisiopatologia , Humanos
9.
Artigo em Inglês | MEDLINE | ID: mdl-29993371

RESUMO

Plaque strain and blood vector velocity imaging of stenosed arteries are expected to aid in diagnosis and prevention of cerebrovascular disease. Ultrafast plane wave imaging enables simultaneous strain and velocity estimation. Multiple ultrasound vendors are introducing high-frequency ultrasound probes and systems. This paper investigates whether the use of high-frequency ultrafast ultrasound is beneficial for assessing blood velocities and strain in arteries. The performance of strain and blood flow velocity estimation was compared between a high-frequency transducer (MS250, fc = 21 MHz) and a clinically utilized transducer (L12-5, fc = 9 MHz). Quantitative analysis based on straight tube phantom experiments revealed that the MS250 outperformed the L12-5 in the superficial region: low velocities near the wall were more accurately estimated and wall strains were better resolved. At greater than 2-cm echo depth, the L12-5 performed better due to the high attenuation of the MS250 probe. Qualitative comparison using a perfused patient-specific carotid bifurcation phantom confirmed these findings. Thus, in conclusion, for strain and blood velocity estimation for depths up to ~2 cm, a high-frequency probe is recommended.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Ultrassonografia/métodos , Idoso , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Desenho de Equipamento , Humanos , Masculino , Modelos Cardiovasculares , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/fisiopatologia , Álcool de Polivinil , Ultrassonografia/instrumentação
10.
Artigo em Inglês | MEDLINE | ID: mdl-27249826

RESUMO

Cardiovascular disease (CVD) is a leading cause of death and is in the majority of cases due to the formation of atherosclerotic plaques in arteries. Initially, thickening of the inner layer of the arterial wall occurs. Continuation of this process leads to plaque formation. The risk of a plaque to rupture and thus to induce an ischemic event is directly related to its composition. Consequently, characterization of the plaque composition and its proneness to rupture are of crucial importance for risk assessment and treatment strategies. The carotid is an excellent artery to be imaged with ultrasound because of its superficial position. In this review, ultrasound-based methods for characterizing the mechanical properties of the carotid wall and atherosclerotic plaque are discussed. Using conventional echography, the intima media thickness (IMT) can be quantified. There is a wealth of studies describing the relation between IMT and the risk for myocardial infarction and stroke. Also the carotid distensibility can be quantified with ultrasound, providing a surrogate marker for the cross-sectional mechanical properties. Although all these parameters are associated with CVD, they do not easily translate to individual patient risk. Another technique is pulse wave velocity (PWV) assessment, which measures the propagation of the pressure pulse over the arterial bed. PWV has proven to be a marker for global arterial stiffness. Recently, an ultrasound-based method to estimate the local PWV has been introduced, but the clinical effectiveness still needs to be established. Other techniques focus on characterization of plaques. With ultrasound elastography, the strain in the plaque due to the pulsatile pressure can be quantified. This technique was initially developed using intravascular catheters to image coronaries, but recently noninvasive methods were successfully developed. A high correlation between the measured strain and the risk for rupture was established. Acoustic radiation force impulse (ARFI) imaging also provides characterization of local plaque components based on mechanical properties. However, both elastography and ARFI provide an indirect measure of the elastic modulus of tissue. With shear wave imaging, the elastic modulus can be quantified, although the carotid artery is one of the most challenging tissues for this technique due to its size and geometry. Prospective studies still have to establish the predictive value of these techniques for the individual patient. Validation of ultrasound-based mechanical characterization of arteries and plaques remains challenging. Magnetic resonance imaging is often used as the "gold" standard for plaque characterization, but its limited resolution renders only global characterization of the plaque. CT provides information on the vascular tree, the degree of stenosis, and the presence of calcified plaque, while soft plaque characterization remains limited. Histology still is the gold standard, but is available only if tissue is excised. In conclusion, elastographic ultrasound techniques are well suited to characterize the different stages of vascular disease.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea , Estenose das Carótidas/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Artérias Carótidas/patologia , Humanos , Análise de Onda de Pulso
11.
Artigo em Inglês | MEDLINE | ID: mdl-27824559

RESUMO

Conventional color Doppler imaging is limited, since it only provides velocity estimates along the ultrasound beam direction for a restricted field of view at a limited frame rate. High-frame-rate speckle tracking, using plane wave transmits, has shown potential for 2-D blood velocity estimation. However, due to the lack of focusing in transmit, image quality gets reduced, which hampers speckle tracking. Although ultrafast imaging facilitates improved clutter filtering, it still remains a major challenge in blood velocity estimation. Signal dropouts and poor velocity estimates are still present for high beam-to-flow angles and low blood flow velocities. In this paper, ultrafast plane wave imaging was combined with multiscale speckle tracking to assess the 2-D blood velocity vector in a common carotid artery (CCA) flow field. A multiangled plane wave imaging sequence was used to compare the performance of displacement compounding, coherent compounding, and compound speckle tracking. Zero-degree plane wave imaging was also evaluated. The performance of the methods was evaluated before and after clutter filtering for the large range of velocities (0-1.5 m/s) that are normally present in a healthy CCA during the cardiac cycle. An extensive simulation study was performed, based on a sophisticated model of the CCA, to investigate and evaluate the performance of the methods at different pulse repetition frequencies and signal-to-noise levels. In vivo data were acquired of a healthy carotid artery bifurcation to support the simulation results. In general, methods utilizing compounding after speckle tracking, i.e., displacement compounding and compound speckle tracking, were least affected by clutter filtering and provided the most robust and accurate estimates for the entire velocity range. Displacement compounding, which uses solely axial information to estimate the velocity vector, provided most accurate velocity estimates, although it required sufficiently high pulse repetition frequencies in high blood velocity phases and reliable estimates for all acquisition angles. When this latter requirement was not met, compound speckle tracking was most accurate, because it uses the possibility to discard angular velocity estimates corrupted by clutter filtering. Similar effects were observed for in vivo data obtained at the carotid artery bifurcation. Investigating a combination of these two compounding techniques is recommended for future research.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Imageamento Tridimensional/métodos , Modelos Cardiovasculares , Ultrassonografia/métodos , Velocidade do Fluxo Sanguíneo , Humanos
12.
Artigo em Inglês | MEDLINE | ID: mdl-27576246

RESUMO

Three-dimensional (3-D) strain estimation might improve the detection and localization of high strain regions in the carotid artery (CA) for identification of vulnerable plaques. This paper compares 2-D versus 3-D displacement estimation in terms of radial and circumferential strain using simulated ultrasound (US) images of a patient-specific 3-D atherosclerotic CA model at the bifurcation embedded in surrounding tissue generated with ABAQUS software. Global longitudinal motion was superimposed to the model based on the literature data. A Philips L11-3 linear array transducer was simulated, which transmitted plane waves at three alternating angles at a pulse repetition rate of 10 kHz. Interframe (IF) radio-frequency US data were simulated in Field II for 191 equally spaced longitudinal positions of the internal CA. Accumulated radial and circumferential displacements were estimated using tracking of the IF displacements estimated by a two-step normalized cross-correlation method and displacement compounding. Least-squares strain estimation was performed to determine accumulated radial and circumferential strain. The performance of the 2-D and 3-D methods was compared by calculating the root-mean-squared error of the estimated strains with respect to the reference strains obtained from the model. More accurate strain images were obtained using the 3-D displacement estimation for the entire cardiac cycle. The 3-D technique clearly outperformed the 2-D technique in phases with high IF longitudinal motion. In fact, the large IF longitudinal motion rendered it impossible to accurately track the tissue and cumulate strains over the entire cardiac cycle with the 2-D technique.


Assuntos
Aterosclerose/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Modelos Cardiovasculares , Ultrassonografia , Algoritmos , Artérias Carótidas/patologia , Humanos , Imagens de Fantasmas , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA