Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1141-1149, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38038728

RESUMO

PURPOSE: To propose a minimum specification dataset to characterize liquid ocular endotamponades (OEs), namely silicone oil (SO), heavy SO (HSO), perfluorodecalin (PFD), and perfluoro-octane (PFO), in terms of physicochemical properties, purity and available evidence of safety, in line with ISO16672:2020. METHODS: An evidence-based consensus using the expert panel technique was conducted. Two facilitators led a committee of 11 European experts. Facilitators prepared a dataset for each compound including the list of specifications relevant for the safety, identified by the group members on the basis of expertise and a comprehensive literature review. Each item was ranked by each member using a 9-point scale from 1 "absolutely to not include" to 9 "absolutely to include" in two rounds followed by discussion. Only items reaching consensus (score ≥ 7 from ≥ 75% of members) were included in the final datasets. RESULTS: For all OEs, consensus was reached to include manufacturer, density, refractive index, chemical composition, dynamic viscosity, interfacial and surface tension, endotoxins, in vitro cytotoxicity assessment, and any evidence from ex vivo and/or in vivo tests for safety assessment. Additional specifications were added for SO (molecular weight distribution, content of oligosiloxanes with MW ≤ 1000 g/mol, spectral transmittance) and PFD/PFO (% of pure PFD/PFO in the final product, vapor pressure, chemical analyses performed for safety assessment). CONCLUSION: The proposed evidence-based minimum specification datasets for SO, HSO, PFD, and PFO have the potential to provide surgeons and health service purchasers with an easily available overview of the most relevant information for the safety assessment of OEs.


Assuntos
Olho , Fluorocarbonos , Humanos , Tamponamento Interno
2.
Retina ; 44(3): 421-428, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37973046

RESUMO

PURPOSE: To assess the long-term visual recovery in uncomplicated macula-off pseudophakic rhegmatogenous retinal detachment treated with pars plana vitrectomy and gas tamponade in the absence of other visual comorbidities. METHODS: Single-center retrospective longitudinal study on eyes with macula-off pseudophakic rhegmatogenous retinal detachment successfully treated with pars plana vitrectomy between 2011 and 2020 and with at least 2 follow-ups (FU), first gas-free FU (first-FU) and a final-FU, were included. Patients with subsequent ocular surgery or comorbidities affecting best-corrected visual acuity were excluded. The duration between operation date and final-FU was calculated (total days FU) and split into total days quintiles-1: ≤57, 2: >57 and ≤77, 3: >77 and ≤152, 4: >152 and ≤508, and 5: >508 days. Multivariable regression was performed with logMAR gain between the first and the final-FU as the dependent variable. RESULTS: In 209 eyes, the authors report association with increase of logMAR gain between the first and the final-FU, with reducing clock hours of pseudophakic rhegmatogenous retinal detachment ( P = 0.041) and relative to the total days Quintile 1. Mean (SD) logMAR gain between the first and the final-FU was 0.02 (0.07) in the first quintile, increasing to 0.14 (0.13) ( P < 0.001) by the fifth quintile on multivariable regression. For patients not achieving 0.30 logMAR at the first-FU, this was attained at the final-FU with a sensitivity of 51.9% and specificity of 95.5% at a cut off ≤0.58 logMAR at the first-FU (area under the curve 0.756 [95% confidence interval 0.664-0.848], P < 0.001). CONCLUSION: The authors report a significant time-dependent visual improvement after uncomplicated pars plana vitrectomy with gas tamponade for macula-off pseudophakic rhegmatogenous retinal detachment without visual confounders and provide important quantitative data for counselling patients with macula-off repair.


Assuntos
Descolamento Retiniano , Humanos , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Estudos Retrospectivos , Estudos Longitudinais , Resultado do Tratamento , Acuidade Visual , Vitrectomia/efeitos adversos
3.
Retina ; 44(5): 791-798, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38236936

RESUMO

PURPOSE: To compare SF 6 relative with C 2 F 6 in the anatomical and functional outcomes following pars plana vitrectomy for uncomplicated primary pseudophakic rhegmatogenous retinal detachment with inferior causative breaks. METHODS: This is a retrospective, comparative study on eyes with pseudophakic rhegmatogenous retinal detachment with inferior causative breaks that had small-gauge pars plana vitrectomy repair using SF 6 and C 2 F 6 tamponade between 2011 and 2020 at a tertiary centre in the United Kingdom. Primary outcome was single surgery anatomical success, and the secondary outcome was best-corrected visual acuity. Propensity score matching, using preoperative findings as covariates to account for relevant confounders, was performed. RESULTS: From 162 pseudophakic rhegmatogenous retinal detachment eyes with inferior causative breaks, the median (interquartile range) follow-up was 82 (52-182) days. The single surgery anatomical success was 156 (96.3%) overall: 47 of 47 (100.0%) and 109 of 115 (94.8%) in the SF 6 and C 2 F 6 groups, respectively ( P = 0.182). Relative to the SF 6 group, the C 2 F 6 group had a higher mean number of tears (SF 6 : 3.1[2.0], C 2 F 6 : 4.5[2.7], P = 0.002) and greater retinal detachment extent (SF 6 : 5.3[2.9], C 2 F 6 : 6.2[2.6] clock hours, P = 0.025). Following propensity score matching analysis, 80 eyes were matched with 40 in each group to homogenize preoperative factors. No significant difference was found in single surgery anatomical success and best-corrected visual acuity between the groups following propensity score matching. CONCLUSION: Primary pars plana vitrectomy with gas tamponade leads to a high single surgery anatomical success rate in uncomplicated pseudophakic rhegmatogenous retinal detachment with inferior causative breaks with no additional benefit associated with long-acting tamponade when comparing C 2 F 6 with SF 6 .


Assuntos
Tamponamento Interno , Fluorocarbonos , Pseudofacia , Descolamento Retiniano , Hexafluoreto de Enxofre , Acuidade Visual , Vitrectomia , Humanos , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Vitrectomia/métodos , Estudos Retrospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia , Pseudofacia/complicações , Tamponamento Interno/métodos , Idoso , Hexafluoreto de Enxofre/administração & dosagem , Pessoa de Meia-Idade , Fluorocarbonos/administração & dosagem , Perfurações Retinianas/cirurgia , Perfurações Retinianas/etiologia , Perfurações Retinianas/diagnóstico , Seguimentos , Resultado do Tratamento
4.
Graefes Arch Clin Exp Ophthalmol ; 261(6): 1553-1562, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36512088

RESUMO

PURPOSE: To assess study design and a range of anatomical and functional changes after internal limiting membrane (ILM) peeling using forceps developed for atraumatic ILM pick-up compared to standard forceps. METHODS: We conducted a masked proof-of concept randomised controlled trial (RCT) on 65 patients who underwent ILM peeling for idiopathic full-thickness macular hole (FTMH) using etched-tip forceps (etched-tip group, 33 eyes) compared to standard ILM forceps (smooth-tip group, 32 eyes). Patients were assessed preoperatively, 3 weeks, 3 and 6 months postoperatively. RESULTS: The primary closure rate was 95.4%. There was no statistically significant difference between the groups in terms of final visual acuity (66.9 vs 70.9 ETDRS letters, p = 0.13), difference of visual field mean deviation (1.32 vs 1.14 decibels), and number of eyes with pick-up-related retinal haemorrhages (16% vs 16%, p = 0.96), swelling of arcuate nerve fibre layer lesions (63% vs 55%, p = 0.54), number of dissociated optic nerve fibre layer lesions (31.4 vs 41.0, p = 0.16), nor inner retina defects (37% vs 22%, p = 0.17). Similar changes in inner retinal volumes were detected in all 9 sectors of an ETDRS grid except for a trend (p = 0.06) towards a lower reduction in the inferior inner sector in the etched-tip group. CONCLUSIONS: The study was successfully completed with masking maintained and a low risk of bias. Multiple endpoints relating to ILM peeling were assessed, and estimates were provided that can be used for future studies. Although the study was not powered to assess any specific endpoint, the anatomical and functional outcomes assessed did not significantly differ.


Assuntos
Membrana Epirretiniana , Perfurações Retinianas , Humanos , Perfurações Retinianas/diagnóstico , Perfurações Retinianas/cirurgia , Membrana Epirretiniana/cirurgia , Vitrectomia , Membrana Basal/cirurgia , Membrana Basal/patologia , Tomografia de Coerência Óptica , Retina/patologia , Estudos Retrospectivos
5.
Graefes Arch Clin Exp Ophthalmol ; 261(9): 2517-2524, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37119305

RESUMO

PURPOSE: To investigate the effect of isovolumetric and expansile gas tamponade concentrations on single surgery anatomical success (SSAS) and day 1 intraocular pressure (IOPD1) following pars plana vitrectomy (PPV) for mild-moderate complexity primary pseudophakic rhegmatogenous retinal detachment (PRD). METHODS: We conducted a single-centre retrospective continuous and comparative study on eyes that had undergone small-gauge PPV using isovolumetric versus expansile gas for PRD repair between 2011 and 2020 at a single tertiary vitreoretinal centre in UK. We performed propensity score matching (PSM) using preoperative findings as covariates to account for relevant confounders. Significant risk factors such as proliferative vitreoretinopathy C or giant retinal tears were excluded. RESULTS: From 456 eyes, PSM analysis matched 240 eyes with 120 in each group. The median (interquartile range) follow-up was 96 (59 to 218) days. The SSAS was 229/240 (95.8%) overall; 115/120 (95.8%) and 114/120 (95.0%) in isovolumetric and expansile groups, respectively (p = 1.000). Relative to the isovolumetric group, the expansile group had lower proportion of eyes with IOP ≤ 21 mmHg (odds ratio, 95% confidence interval, 0.40 [0.23-0.68], p < 0.001); but significantly higher number of eyes with IOP ≥ 22 mmHg (2.53 [1.48-4.34], p < 0.001), ≥ 25 mmHg (2.77 [1.43-5.33], p < 0.001), ≥ 30 mmHg (2.90 [1.28-6.58], p = 0.006) and ≥ 40 mmHg (p = 0.029, isovolumetric: 0 [0%] vs expansile group: 6 [5%]). There was only one case of hypotony (≤ 5 mmHg) 1/240 (0.4%) which occurred in the expansile group. CONCLUSIONS: Expansile gas concentration does not impact SSAS but is associated with significantly raised IOPD1 with no reduction in hypotony rates following PPV for primary PRD.


Assuntos
Descolamento Retiniano , Humanos , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Pressão Intraocular , Estudos Retrospectivos , Acuidade Visual , Retina , Vitrectomia/efeitos adversos , Resultado do Tratamento , Complicações Pós-Operatórias/cirurgia
6.
Retina ; 43(8): 1370-1376, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37071921

RESUMO

PURPOSE: To propose the InTraocular EMulsion of Silicone oil (ITEMS) grading system for the assessment of silicone oil (SiO) emulsion, applicable in a routine clinical setting and validated through an expert-led consensus procedure. METHODS: Seven experts on intraocular liquid tamponades, led by a facilitator, performed a literature review on the detection of SiO emulsion. Based on the proposed ideas, a questionnaire was developed and submitted to the experts on the methods to detect SiO emulsion and the items to grade. After 2 rounds of individual ranking using a 9-point scale and related discussion, the final grading system was developed including items that reached consensus (score ≥7 from ≥75% of members). RESULTS: The agreed ITEMS grading system includes the identification of SiO microbubbles and large SiO bubbles through slit-lamp biomicroscopy, gonioscopy, fundus examination under mydriasis, or ultra-wide-field fundus photography. Moreover, macular and disk optical coherence tomography are used to detect SiO-associated hyperreflective dots. CONCLUSION: An evidence-based expert-led consensus was conducted to develop grading system of SiO emulsion, allowing, for the first time, homogenous collection of data on SiO emulsion. This has the potential to improve the understanding of the role and clinical relevance of SiO emulsion, allowing comparisons between different studies.


Assuntos
Emulsões , Descolamento Retiniano , Vitrectomia , Humanos , Óleos de Silicone , Vitrectomia/métodos , Consenso
7.
Int J Mol Sci ; 24(13)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37445711

RESUMO

Subretinal injection is performed in vitreoretinal surgery with two main aims, namely, the subretinal delivery of therapeutic agents and subretinal injection of fluid to induce a controlled and localized macular detachment. The growing interest in this technique is mainly related to its suitability to deliver gene therapy in direct contact with target tissues. However, subretinal injection has been also used for the surgical management of submacular hemorrhage through the subretinal delivery of tissue plasminogen activator, and for the repair of full-thickness macular holes, in particular refractory ones. In the light of the increasing importance of this maneuver in vitreoretinal surgery as well as of the lack of a standardized surgical approach, we conducted a comprehensive overview on the current indications for subretinal injection, surgical technique with the available variations, and the potential complications.


Assuntos
Fibrinolíticos , Ativador de Plasminogênio Tecidual , Ativador de Plasminogênio Tecidual/uso terapêutico , Fibrinolíticos/uso terapêutico , Vitrectomia/métodos , Acuidade Visual , Tomografia de Coerência Óptica , Estudos Retrospectivos
8.
Medicina (Kaunas) ; 59(3)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36984584

RESUMO

Suprachoroidal hemorrhage (SCH) is a rare and sight-threatening complication of various intraocular surgeries, including cataract surgery. Although the rate of SCH complicating cataract surgery has decreased in the era of phacoemulsification, most likely due to smaller self-sealing incisions and modern equipment, it remains a challenging complication to manage. The aim of this review is to summarize the current evidence of the pathophysiology and management of SCH complicating phaco surgery. A literature review was performed using the PubMed database searching for diagnosis, therapy, and management of SCH during phacoemulsification. The evidence available on the optimal management of this condition is low, and there is no consensus so far. An early diagnosis is thought to be essential to avoid progression to the devastating stage of expulsion of intraocular contents (expulsive hemorrhage). Sudden intraoperative anterior chamber shallowing, red reflex loss, and a significant increase in intraocular pressure are highly suspicious for this severe complication. A fundus examination and ocular ultrasound are crucial to confirm the diagnosis and, if it is confirmed, stabilize the globe immediately. The initial therapeutic approach includes aggressive topical and systemic medication focused on controlling ocular inflammation and intraocular pressure, whereas the timing and the indications of surgical intervention remain controversial.


Assuntos
Extração de Catarata , Catarata , Hemorragia da Coroide , Facoemulsificação , Humanos , Facoemulsificação/efeitos adversos , Hemorragia da Coroide/etiologia , Hemorragia da Coroide/terapia , Pressão Intraocular
9.
Exp Eye Res ; 213: 108837, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34774490

RESUMO

This study aimed to evaluate viability of retinal cells after the use of multiple intraoperative devices, namely a vitreal dye (triamcinolone acetonide,TA), a ERM/ILM dye (solution of trypan blue 0.15% and brilliant blue 0.025%), and two intraocular tamponades, namely perfluoro-n-octane, (PFO) and silicone oil (SO 1000 cSt), with minimal and maximal removal of their residues, during a simulated pars plana vitrectomy (PPV) in porcine eyes ex-vivo. The in vitro cytotoxicity of each of these compounds was verified on ARPE-19 cells by direct tests according to the ISO 10993-5 (2009). Pars plana vitrectomy was performed on 25 enucleated porcine eyes divided in five groups according to the following conditions: Group A) No surgery control: eye bulbs were kept at room temperature for 40 min; Group B) Sham surgery: PPV with the sole use of BSS for 40 min; Group C) Cytotoxic control: PPV with BSS infusion (20 min) followed by intravitreal injection of 1H-PFO (contact time: 20 min); Group D) Surgery with residues: PPV with BSS infusion and sequential intravitreal injection of TA, ERM/ILM dye, PFO and SO, with minimal removal of each compound after a specified contact-time (overall duration: 40 min); Group E) Surgery with minimal residues: PPV performed as in group D, but with maximal removal of each compound (overall duration: 40 min). All the experimental procedures were performed at room temperature. Immediately after surgery, the retina was extracted from each eye bulb and samples of 3-mm diameter were prepared. Retinal viability was determined for each sample by 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyltetrazolium bromide assay. A cell viability <70% was considered the cytotoxicity threshold. Kruskal-Wallis test was used to evaluate the differences in retinal viability between groups. No cytotoxicity was detected in retinal samples in groups A, B and E. Samples from eye bulbs that had undergone surgery with minimal removal of residues (group D) and cytotoxic controls (group C) showed high retinal cytotoxicity. The tested conditions indicated that the combined use of TA, ERM/ILM dye, PFO and SO during PPV does not affect retinal cells viability if all the devices are properly removed, whereas the cytotoxicity detected in group D may suggest that the presence and accumulation of the residues of the compounds used intraoperatively could negatively impact retinal viability due to a cumulative and/or synergistic cytotoxic effect between them, supporting the crucial role of an optimal removal of the intraoperative medical devices to ensure a safe vitrectomy to the patient.


Assuntos
Benzenossulfonatos/toxicidade , Fluorocarbonos/toxicidade , Retina/efeitos dos fármacos , Óleos de Silicone/toxicidade , Triancinolona Acetonida/toxicidade , Azul Tripano/toxicidade , Vitrectomia , Animais , Linhagem Celular , Sobrevivência Celular , Corantes/toxicidade , Tamponamento Interno , Glucocorticoides/toxicidade , Humanos , Modelos Animais , Retina/patologia , Epitélio Pigmentado da Retina/efeitos dos fármacos , Epitélio Pigmentado da Retina/patologia , Suínos
10.
Graefes Arch Clin Exp Ophthalmol ; 259(5): 1113-1121, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33394160

RESUMO

PURPOSE: To assess the influence of rheological properties of an artificial vitreous (AV) on the performance of double-blade (DB) and single-blade (SB) guillotine vitreous cutters, with 23-, 25-, and 27-gauge (G) probes. METHODS: We evaluate the aspiration flow rate, using an optical method, based on image processing. Experiments are conducted using ten viscoelastic vitreous phantoms, with different properties that are measured with rheological tests. RESULTS: Aspiration rate strongly varies with fluid properties. Regardless of cutter geometry and operational conditions, the flow rate significantly decreases as vitreous viscosity and elasticity increase. CONCLUSIONS: All tested vitreous probes are very sensitive to changes in fluid rheology. SB cutters produce smaller flow rates compared with DB ones of the same caliber; however, they are less sensitive to fluid properties at low aspiration pressures. The use of vitreous substitutes for test performance guarantees comparability between flow rate results achieved with different vitrectomy systems operating in different media. This outcome is further confirmed by the low values of estimated flow rate relative errors.


Assuntos
Vitrectomia , Corpo Vítreo , Elasticidade , Humanos , Microcirurgia , Reologia , Corpo Vítreo/cirurgia
11.
Retina ; 41(12): 2523-2530, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34001821

RESUMO

PURPOSE: To evaluate the safety, effectiveness, and the best parameters setup of hypersonic vitrectomy. METHODS: A prospective, multicentric, interventional study on 50 eyes that had undergone hypersonic vitrectomy because of various vitreoretinal diseases. We primarily assessed the effectiveness of vitreous removal, intraoperative complications, and surgical setup. Secondarily, we evaluated single-surgery anatomical success and postoperative best-corrected visual acuity. RESULTS: Intraoperative complications occurred in 5 eyes (10%), whereas technical problems were detected in 23 eyes (46%), resulting in conversion to guillotine vitrectomy in 15 cases. The most common finding related to the technical problems was an inadequate vitreous liquefaction with the formation of vitreous strands and consequent inadequate vitreous outflow, sometimes complicated by vitreous incarceration in the vitrectomy probe. The best settings were considered a stroke of 60 µm and vacuum of 40 mmHg for both core and peripheral vitrectomy. At 3-month follow-up, primary anatomical success was achieved in 49 eyes (98%) and the mean best-corrected visual acuity overall improved. CONCLUSION: The availability of hypersonic vitrectomy in the current surgical practice opens a new era in vitreoretinal surgery. Despite the potential advantages in fluidics, the performance of hypersonic vitrectomy system needs to be further optimized, mainly for the occurrence of inadequate vitreous liquefaction and vitreous strands formation.


Assuntos
Doenças Retinianas/cirurgia , Procedimentos Cirúrgicos Ultrassônicos/métodos , Vitrectomia/métodos , Idoso , Tamponamento Interno , Feminino , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Prospectivos , Doenças Retinianas/fisiopatologia , Resultado do Tratamento , Acuidade Visual/fisiologia , Cirurgia Vitreorretiniana
12.
Int J Mol Sci ; 22(18)2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34576231

RESUMO

Toxic tumour syndrome (TTS) is a particularly aggressive form of secondary vasculopathy occurring after radiation therapy of uveal melanoma due to the persistence of the necrotic tumour mass inside the eye. The development of TTS confers a particularly unfavourable functional and anatomical ocular prognosis, ultimately requiring enucleation in most cases if untreated. Vitreoretinal (VR) surgery has been successfully applied for treatment and prevention of TTS using both resecting and non-resecting techniques. In this systematic review, we aim to define characteristics of uveal melanomas benefiting the most from secondary VR surgery and to outline the optimal type and timing of VR intervention in such cases. Analysis of the literature reveals that endoresection should be performed within 3 months after radiotherapy to tumours thicker than 7 mm and with a largest basal diameter between 8 mm and 15 mm with post-equatorial location, especially after proton beam treatment. Alternatively, endodrainage remains a valid therapeutic option in eyes with macula-off retinal detachment, tumour diameter larger than 15 mm or ciliary body involvement. VR surgery can be successful in the management of TTS following radiotherapy for uveal melanoma when timing and indication are appropriately evaluated.


Assuntos
Transtornos Cerebrovasculares/prevenção & controle , Neoplasias da Coroide/radioterapia , Neoplasias da Coroide/cirurgia , Melanoma/radioterapia , Melanoma/cirurgia , Neoplasias Uveais/radioterapia , Neoplasias Uveais/cirurgia , Cirurgia Vitreorretiniana/métodos , Neoplasias da Coroide/patologia , Corpo Ciliar , Humanos , Melanoma/patologia , Prognóstico , Terapia com Prótons , Radioterapia/efeitos adversos , Descolamento Retiniano/patologia , Neoplasias Uveais/patologia , Acuidade Visual
13.
Exp Eye Res ; 194: 108018, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32209320

RESUMO

This study aimed to assess the cytotoxic effect of low molecular weight components (LMWC) and conventional silicone oils (SOs) 1000 cSt with different degree of purification (raw, intermediate, and purified) using in vitro cytotoxicity tests. Direct contact cytotoxicity tests were performed in BALB 3T3 and human retinal pigment epithelial cells (ARPE-19) using quantitative and qualitative evaluation according to the ISO 10993-5 (2009) standards. Conventional SOs 1000 cSt in form of raw, intermediate (intermediate product obtained during distillation process), and purified SO (final product after distillation) and a concentrate of LMWC (including siloxane chains with molecular weight up to 1557 g/mol) were directly applied to 100% of cell layer area for 24 h. Cell viability was quantified using 3-(4,5-dimethylthiazole-2-yl)-2,5-28 diphenyltetrazolium bromide (MTT) and neutral red uptake assays in ARPE-19 and BALB3T3, respectively. All tested samples, including the concentrate of LMWC, resulted to be not cytotoxic according to ISO 10993-5 in both qualitative and quantitative evaluations. However, the cellular viability was significantly higher in the intermediate and purified SO compared with the raw SO in ARPE-19 cells. No reduction in cell viability was detected by LMWC. The absence of cytotoxicity was observed for all tested samples in both BALB3T3 and ARPE-19 after 24 h of application. A direct cytotoxic effect is not likely to be involved in the potential complications related to SO and LMWC. Long-term potential adverse effects of SO could be related to the raw material and to different concentrations of LMWC.


Assuntos
Tamponamento Interno/métodos , Retina/efeitos dos fármacos , Doenças Retinianas/cirurgia , Óleos de Silicone/efeitos adversos , Cirurgia Vitreorretiniana/métodos , Corpo Vítreo/efeitos dos fármacos , Animais , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Cromatografia , Modelos Animais de Doenças , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Retina/patologia , Doenças Retinianas/patologia , Corpo Vítreo/patologia
14.
Int Ophthalmol ; 40(8): 2119-2127, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32383130

RESUMO

BACKGROUND: Optic disc drusen (ODD) are acellular deposits in the prelaminar optic nerve head. The most accredited theory is that they are secondary to abnormalities in axonal metabolism and degeneration, but the pathogenesis is not clear to date. CLINICAL MANIFESTATION: Although ODD are often considered a benign condition, the great majority of patients with ODD show visual field defects and are at higher risk for developing anterior ischemic optic neuropathy. ODD are classified as superficial or buried, with the latter being often misdiagnosed as papilledema with optic nerve head swelling, leading to an unnecessary investigation for causes of increased intracranial pressure. AIM: The recent technological improvements in OCT imaging which allowed an earlier and more certain diagnosis even of the smallest ODD, renovated the interest around this pathology. However, an updated systematic review is still missing. Therefore, the aim of this work is to provide a concise yet comprehensive overview of the current state of art, focusing on pathophysiology, clinical presentation, diagnostic methods, treatment modalities and potential future perspectives of this condition.


Assuntos
Drusas do Disco Óptico , Disco Óptico , Neuropatia Óptica Isquêmica , Papiledema , Humanos , Drusas do Disco Óptico/diagnóstico , Papiledema/diagnóstico , Papiledema/etiologia , Testes de Campo Visual
16.
Graefes Arch Clin Exp Ophthalmol ; 257(1): 1-8, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30377798

RESUMO

Diabetic macular edema (DME) is still one of the main causes of visual impairment. Repeated intravitreal injections of ranibizumab are considered the gold standard treatment, but the efficacy in patients with prominent cystic characteristics remains uncertain. In diabetic retinas, the identification of both antero-posterior and, particularly, tangential tractions is crucial to prevent misdiagnosis of tractional and refractory DME, and therefore to prevent poor treatment outcomes. The treatment of tractional DME with anti-VEGF injections could be poorly effective due to the influence of a tractional force. Pars plana vitrectomy (PPV) is a surgical procedure that has been widely used in the treatment of diffuse and refractory DME. Anatomical improvement, although stable and immediate, did not result in visual improvement. PPV with internal limiting membrane (ILM) peeling for the treatment of non-tractional DME in patients with prominent cysts (> 390 µm) causes subfoveal atrophy, defined as "floor effect". Epiretinal tangential forces and intraretinal change evaluation by SD-OCT of non-tractional DME are essential for determining appropriate management.


Assuntos
Retinopatia Diabética/complicações , Macula Lutea/patologia , Edema Macular/diagnóstico , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Corpo Vítreo/patologia , Retinopatia Diabética/diagnóstico , Humanos , Edema Macular/etiologia
17.
Graefes Arch Clin Exp Ophthalmol ; 256(9): 1573-1580, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29948176

RESUMO

PURPOSE: To describe functional and histopathological findings after macular peeling using different dyes. METHODS: Prospective, randomized, comparative, interventional, and immunohistochemical study. Forty-five eyes from 45 patients with idiopathic epiretinal membrane (ERM) underwent pars plana chromovitrectomy with ERM and inner limiting membrane (ILM) using trypan blue 0.15% + brilliant blue 0.05% + lutein 2% in group 1 (15 eyes), trypan blue 0.15% + brilliant blue 0.025% + polyethylene glycol 3350 4% in group 2 (15 eyes), and indocyanine green 0.05% in group 3 (15 eyes). We evaluated visual acuity (VA) and macular sensitivity (MS) preoperatively, 1, 3, and 6 months after surgery. The expression of glial fibrillary acidic protein (GFAP) and neurofilament protein (NF) was assessed immunohistochemically on the ILMs peeled as markers of glial and neuronal cells. RESULTS: In group 1, both mean VA and MS were significantly better at 1 and 3 months after surgery (P < 0.05), whereas no significant difference was found after 6 months. GFAP and NF expression was significantly lower in group 1 (P < 0.05). CONCLUSIONS: The ERM/ILM peeling is thought to rip off the intraretinal tissue, based on the amounts of GFAP and NF in the specimens. The use of lutein dyes reduces iatrogenic stress to the retinal tissue and allows a faster functional recovery in the first 3 months after surgery, suggesting a less iatrogenic adhesion to the retinal tissue.


Assuntos
Membrana Basal/cirurgia , Corantes/farmacologia , Membrana Epirretiniana/cirurgia , Angiofluoresceinografia/métodos , Complicações Intraoperatórias/diagnóstico , Células Ganglionares da Retina/patologia , Vitrectomia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Membrana Basal/patologia , Células Ependimogliais/patologia , Membrana Epirretiniana/patologia , Membrana Epirretiniana/fisiopatologia , Feminino , Seguimentos , Fundo de Olho , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Vitrectomia/métodos
19.
Retina ; 37(4): 637-642, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27465573

RESUMO

PURPOSE: To compare the safety and efficacy of 27-gauge (G) pars plana vitrectomy (PPV) with 25-G PPV for the treatment of primary rhegmatogenous retinal detachment (RRD). METHODS: In this prospective randomized comparative interventional study, 15 eyes from 30 patients were treated with 27-G PPV (Group A); the other 15 eyes underwent 25-G PPV (Group B). All patients were examined preoperatively and then 1 day, 1 week, 1 month, 3 months, and 6 months after PPV. RESULTS: In each group, retinal reattachment was observed in 14 out of 15 eyes after surgery. After six months, both groups showed a statistically significant improvement in mean BCVA (P < 0.001); the difference between the two groups was not statistically significant. No cases of ocular hypotony were seen, whereas intraocular hypertension occurred in two patients in Group B. No intraoperative nor postoperative complications were registered. There was no significant difference in operating times (P = 0.52). CONCLUSION: The safety and efficacy of 27-G PPV for rhegmatogenous retinal detachment appear similar to 25-GPPV. We found no anatomical or functional difference in terms of postoperative BCVA, IOP, complications, and operating time. Twenty-seven-G vitrectomy is therefore a valid option in the treatment of rhegmatogenous retinal detachment.


Assuntos
Descolamento Retiniano/cirurgia , Vitrectomia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/etiologia , Duração da Cirurgia , Complicações Pós-Operatórias , Estudos Prospectivos , Acuidade Visual , Vitrectomia/efeitos adversos
20.
Orbit ; 33(4): 283-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24786224

RESUMO

To describe a patient with coexistence of ipsilateral adenoid cystic carcinoma of the lacrimal gland and orbital cavernous hemangioma. The patient presented a 2-month history of painful swelling of left upper eyelid, which did not resolve on a course of oral steroid. On clinical examination, she had moderate medial and inferior dislocation of the eye globe, edema of the temporal superior eyelid and moderate restriction upgaze. Magnetic resonance imaging identified two left orbital tumors: one was a lesion that arose from the lacrimal gland, and the second was a well-defined, ovoid, intraconal mass. The patient underwent lateral orbitotomy and excision of both lesions. Postoperative histological features demonstrated two different lesions: an adenoid cystic carcinoma of the lacrimal gland and a cavernous hemangioma. The clinical presentation of the present case was strongly suggestive of a lacrimal gland malignancy, although the imaging features did not show typical invasive aspects. This is the first report of coexistence of lacrimal gland adenoid cystic carcinoma and cavernous hemangioma in the ipsilateral orbit.


Assuntos
Carcinoma Adenoide Cístico/diagnóstico , Neoplasias Oculares/diagnóstico , Hemangioma Cavernoso/diagnóstico , Doenças do Aparelho Lacrimal/diagnóstico , Segunda Neoplasia Primária/diagnóstico , Neoplasias Orbitárias/diagnóstico , Carcinoma Adenoide Cístico/cirurgia , Neoplasias Oculares/cirurgia , Feminino , Hemangioma Cavernoso/cirurgia , Humanos , Doenças do Aparelho Lacrimal/cirurgia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Segunda Neoplasia Primária/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Neoplasias Orbitárias/cirurgia , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA