Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cochrane Database Syst Rev ; 7: CD011671, 2024 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-38979743

RESUMO

BACKGROUND: Kidney transplantation is the optimal treatment for kidney failure. Donation, transport and transplant of kidney grafts leads to significant ischaemia reperfusion injury. Static cold storage (SCS), whereby the kidney is stored on ice after removal from the donor until the time of implantation, represents the simplest preservation method. However, technology is now available to perfuse or "pump" the kidney during the transport phase ("continuous") or at the recipient centre ("end-ischaemic"). This can be done at a variety of temperatures and using different perfusates. The effectiveness of these treatments manifests as improved kidney function post-transplant. OBJECTIVES: To compare machine perfusion (MP) technologies (hypothermic machine perfusion (HMP) and (sub) normothermic machine perfusion (NMP)) with each other and with standard SCS. SEARCH METHODS: We contacted the information specialist and searched the Cochrane Kidney and Transplant Register of Studies until 15 June 2024 using search terms relevant to this review. Studies in the Register are identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Registry Platform (ICTRP) Search Portal, and ClinicalTrials.gov. SELECTION CRITERIA: All randomised controlled trials (RCTs) and quasi-RCTs comparing machine perfusion techniques with each other or versus SCS for deceased donor kidney transplantation were eligible for inclusion. All donor types were included (donor after circulatory death (DCD) and brainstem death (DBD), standard and extended/expanded criteria donors). Both paired and unpaired studies were eligible for inclusion. DATA COLLECTION AND ANALYSIS: The results of the literature search were screened, and a standard data extraction form was used to collect data. Both of these steps were performed by two independent authors. Dichotomous outcome results were expressed as risk ratios (RR) with 95% confidence intervals (CI). Survival analyses (time-to-event) were performed with the generic inverse variance meta-analysis of hazard ratios (HR). Continuous scales of measurement were expressed as a mean difference (MD). Random effects models were used for data analysis. The primary outcome was the incidence of delayed graft function (DGF). Secondary outcomes included graft survival, incidence of primary non-function (PNF), DGF duration, economic implications, graft function, patient survival and incidence of acute rejection. Confidence in the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. MAIN RESULTS: Twenty-two studies (4007 participants) were included. The risk of bias was generally low across all studies and bias domains. The majority of the evidence compared non-oxygenated HMP with standard SCS (19 studies). The use of non-oxygenated HMP reduces the rate of DGF compared to SCS (16 studies, 3078 participants: RR 0.78, 95% CI 0.69 to 0.88; P < 0.0001; I2 = 31%; high certainty evidence). Subgroup analysis revealed that continuous (from donor hospital to implanting centre) HMP reduces DGF (high certainty evidence). In contrast, this benefit over SCS was not seen when non-oxygenated HMP was not performed continuously (low certainty evidence). Non-oxygenated HMP reduces DGF in both DCD and DBD settings in studies performed in the 'modern era' and when cold ischaemia times (CIT) were short. The number of perfusions required to prevent one episode of DGF was 7.69 and 12.5 in DCD and DBD grafts, respectively. Continuous non-oxygenated HMP versus SCS also improves one-year graft survival (3 studies, 1056 participants: HR 0.46, 0.29 to 0.75; P = 0.002; I2 = 0%; high certainty evidence). Assessing graft survival at maximal follow-up confirmed a benefit of continuous non-oxygenated HMP over SCS (4 studies, 1124 participants (follow-up 1 to 10 years): HR 0.55, 95% CI 0.40 to 0.77; P = 0.0005; I2 = 0%; high certainty evidence). This effect was not seen in studies where HMP was not continuous. The effect of non-oxygenated HMP on our other outcomes (PNF, incidence of acute rejection, patient survival, hospital stay, long-term graft function, duration of DGF) remains uncertain. Studies performing economic analyses suggest that HMP is either cost-saving (USA and European settings) or cost-effective (Brazil). One study investigated continuous oxygenated HMP versus non-oxygenated HMP (low risk of bias in all domains); the simple addition of oxygen during continuous HMP leads to additional benefits over non-oxygenated HMP in DCD donors (> 50 years), including further improvements in graft survival, improved one-year kidney function, and reduced acute rejection. One large, high-quality study investigated end-ischaemic oxygenated HMP versus SCS and found end-ischaemic oxygenated HMP (median machine perfusion time 4.6 hours) demonstrated no benefit compared to SCS. The impact of longer periods of end-ischaemic HMP is unknown. One study investigated NMP versus SCS (low risk of bias in all domains). One hour of end ischaemic NMP did not improve DGF compared with SCS alone. An indirect comparison revealed that continuous non-oxygenated HMP (the most studied intervention) was associated with improved graft survival compared with end-ischaemic NMP (indirect HR 0.31, 95% CI 0.11 to 0.92; P = 0.03). No studies investigated normothermic regional perfusion (NRP) or included any donors undergoing NRP. AUTHORS' CONCLUSIONS: Continuous non-oxygenated HMP is superior to SCS in deceased donor kidney transplantation, reducing DGF, improving graft survival and proving cost-effective. This is true for both DBD and DCD kidneys, both short and long CITs, and remains true in the modern era (studies performed after 2008). In DCD donors (> 50 years), the simple addition of oxygen to continuous HMP further improves graft survival, kidney function and acute rejection rate compared to non-oxygenated HMP. Timing of HMP is important, and benefits have not been demonstrated with short periods (median 4.6 hours) of end-ischaemic HMP. End-ischaemic NMP (one hour) does not confer meaningful benefits over SCS alone and is inferior to continuous HMP in an indirect comparison of graft survival. Further studies assessing NMP for viability assessment and therapeutic delivery are warranted and in progress.


Assuntos
Sobrevivência de Enxerto , Transplante de Rim , Preservação de Órgãos , Perfusão , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Temperatura Baixa , Função Retardada do Enxerto/prevenção & controle , Rim , Transplante de Rim/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Perfusão/instrumentação , Traumatismo por Reperfusão/prevenção & controle , Temperatura , Doadores de Tecidos
2.
Cochrane Database Syst Rev ; 9: CD014685, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37698189

RESUMO

BACKGROUND: Liver transplantation is the only chance of cure for people with end-stage liver disease and some people with advanced liver cancers or acute liver failure. The increasing prevalence of these conditions drives demand and necessitates the increasing use of donated livers which have traditionally been considered suboptimal. Several novel machine perfusion preservation technologies have been developed, which attempt to ameliorate some of the deleterious effects of ischaemia reperfusion injury. Machine perfusion technology aims to improve organ quality, thereby improving outcomes in recipients of suboptimal livers when compared to traditional static cold storage (SCS; ice box). OBJECTIVES: To evaluate the effects of different methods of machine perfusion (including hypothermic oxygenated machine perfusion (HOPE), normothermic machine perfusion (NMP), controlled oxygenated rewarming, and normothermic regional perfusion) versus each other or versus static cold storage (SCS) in people undergoing liver transplantation. SEARCH METHODS: We used standard, extensive Cochrane search methods. The latest search date was 10 January 2023. SELECTION CRITERIA: We included randomised clinical trials which compared different methods of machine perfusion, either with each other or with SCS. Studies comparing HOPE via both hepatic artery and portal vein, or via portal vein only, were grouped. The protocol detailed that we also planned to include quasi-randomised studies to assess treatment harms. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were 1. overall participant survival, 2. quality of life, and 3. serious adverse events. Secondary outcomes were 4. graft survival, 5. ischaemic biliary complications, 6. primary non-function of the graft, 7. early allograft function, 8. non-serious adverse events, 9. transplant utilisation, and 10. transaminase release during the first week post-transplant. We assessed bias using Cochrane's RoB 2 tool and used GRADE to assess certainty of evidence. MAIN RESULTS: We included seven randomised trials (1024 transplant recipients from 1301 randomised/included livers). All trials were parallel two-group trials; four compared HOPE versus SCS, and three compared NMP versus SCS. No trials used normothermic regional perfusion. When compared with SCS, it was uncertain whether overall participant survival was improved with either HOPE (hazard ratio (HR) 0.91, 95% confidence interval (CI) 0.42 to 1.98; P = 0.81, I2 = 0%; 4 trials, 482 recipients; low-certainty evidence due to imprecision because of low number of events) or NMP (HR 1.08, 95% CI 0.31 to 3.80; P = 0.90; 1 trial, 222 recipients; very low-certainty evidence due to imprecision and risk of bias). No trials reported quality of life. When compared with SCS alone, HOPE was associated with improvement in the following clinically relevant outcomes: graft survival (HR 0.45, 95% CI 0.23 to 0.87; P = 0.02, I2 = 0%; 4 trials, 482 recipients; high-certainty evidence), serious adverse events in extended criteria DBD liver transplants (OR 0.45, 95% CI 0.22 to 0.91; P = 0.03, I2 = 0%; 2 trials, 156 participants; moderate-certainty evidence) and clinically significant ischaemic cholangiopathy in recipients of DCD livers (OR 0.31, 95% CI 0.11 to 0.92; P = 0.03; 1 trial, 156 recipients; high-certainty evidence). In contrast, NMP was not associated with improvement in any of these clinically relevant outcomes. NMP was associated with improved utilisation compared with SCS (one trial found a 50% lower rate of organ discard; P = 0.008), but the reasons underlying this effect are unknown. We identified 11 ongoing studies investigating machine perfusion technologies. AUTHORS' CONCLUSIONS: In situations where the decision has been made to transplant a liver donated after circulatory death or donated following brain death, end-ischaemic HOPE will provide superior clinically relevant outcomes compared with SCS alone. Specifically, graft survival is improved (high-certainty evidence), serious adverse events are reduced (moderate-certainty evidence), and in donors after circulatory death, clinically relevant ischaemic biliary complications are reduced (high-certainty evidence). There is no good evidence that NMP has the same benefits over SCS in terms of these clinically relevant outcomes. NMP does appear to improve utilisation of grafts that would otherwise be discarded with SCS; however, the reasons for this, and whether this effect is specific to NMP, is not clear. Further studies into NMP viability criteria and utilisation, as well as head-to-head trials with other perfusion technologies are needed. In the setting of donation following circulatory death transplantation, further trials are needed to assess the effect of these ex situ machine perfusion methods against, or in combination with, normothermic regional perfusion.


Assuntos
Doença Hepática Terminal , Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Qualidade de Vida , Perfusão
3.
Clin Transplant ; 34(4): e13814, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32031711

RESUMO

BACKGROUND: There remains a lack of consensus on the optimal storage method for deceased donor kidneys. This meta-analysis compares storage with hypothermic machine perfusion (HMP) vs traditional static cold storage (SCS). METHODS: The Cochrane Kidney and Transplant Specialised Register was searched to identify (quasi-) randomized controlled trials (RCTs) to include in our meta-analysis. PRISMA guidelines were used to perform and write this review. RESULTS: There is high-certainty evidence that HMP reduces the risk of delayed graft function (DGF) when compared to SCS (2138 participants from 14 studies, RR = 0.77; 0.67-0.90, P = .0006). This benefit is significant in both donation following circulatory death (DCD; 772 patients from seven studies, RR = 0.75; 0.64-0.87, P = .0002) and donation following brainstem death (DBD) grafts (971 patients from four studies, RR = 0.78; 0.65-0.93, P = .006). The number of perfusions required to prevent one episode of DGF was 7.26 and 13.60 in DCD and DBD grafts, respectively. There is strong evidence that HMP also improves graft survival in both DBD and DCD grafts, at both 1 and 3 years. Economic analyses suggest HMP is cost-saving at 1 year compared with SCS. CONCLUSION: Hypothermic machine perfusion is superior to SCS in deceased donor renal transplantation. Direct comparisons with normothermic machine perfusion in RCTs are essential to identify optimal preservation methods in kidney transplantation.


Assuntos
Transplante de Rim , Função Retardada do Enxerto/prevenção & controle , Sobrevivência de Enxerto , Humanos , Rim , Preservação de Órgãos , Perfusão , Doadores de Tecidos
4.
Cochrane Database Syst Rev ; 3: CD011671, 2019 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-30875082

RESUMO

BACKGROUND: Kidney transplantation is the optimal treatment for end-stage kidney disease. Retrieval, transport and transplant of kidney grafts causes ischaemia reperfusion injury. The current accepted standard is static cold storage (SCS) whereby the kidney is stored on ice after removal from the donor and then removed from the ice box at the time of implantation. However, technology is now available to perfuse or "pump" the kidney during the transport phase or at the recipient centre. This can be done at a variety of temperatures and using different perfusates. The effectiveness of treatment is manifest clinically as delayed graft function (DGF), whereby the kidney fails to produce urine immediately after transplant. OBJECTIVES: To compare hypothermic machine perfusion (HMP) and (sub)normothermic machine perfusion (NMP) with standard SCS. SEARCH METHODS: We searched the Cochrane Kidney and Transplant Register of Studies to 18 October 2018 through contact with the Information Specialist using search terms relevant to this review. Studies in the Register are identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Register (ICTRP) Search Portal and ClinicalTrials.gov. SELECTION CRITERIA: All randomised controlled trials (RCTs) and quasi-RCTs comparing HMP/NMP versus SCS for deceased donor kidney transplantation were eligible for inclusion. All donor types were included (donor after circulatory (DCD) and brainstem death (DBD), standard and extended/expanded criteria donors). Both paired and unpaired studies were eligible for inclusion. DATA COLLECTION AND ANALYSIS: The results of the literature search were screened and a standard data extraction form was used to collect data. Both of these steps were performed by two independent authors. Dichotomous outcome results were expressed as risk ratio (RR) with 95% confidence intervals (CI). Continuous scales of measurement were expressed as a mean difference (MD). Random effects models were used for data analysis. The primary outcome was incidence of DGF. Secondary outcomes included: one-year graft survival, incidence of primary non-function (PNF), DGF duration, long term graft survival, economic implications, graft function, patient survival and incidence of acute rejection. MAIN RESULTS: No studies reported on NMP, however one ongoing study was identified.Sixteen studies (2266 participants) comparing HMP with SCS were included; 15 studies could be meta-analysed. Fourteen studies reported on requirement for dialysis in the first week post-transplant (DGF incidence); there is high-certainty evidence that HMP reduces the risk of DGF when compared to SCS (RR 0.77; 95% CI 0.67 to 0.90; P = 0.0006). HMP reduces the risk of DGF in kidneys from DCD donors (7 studies, 772 participants: RR 0.75; 95% CI 0.64 to 0.87; P = 0.0002; high certainty evidence), as well as kidneys from DBD donors (4 studies, 971 participants: RR 0.78, 95% CI 0.65 to 0.93; P = 0.006; high certainty evidence). The number of perfusions required to prevent one episode of DGF (number needed to treat, NNT) was 7.26 and 13.60 in DCD and DBD kidneys respectively. Studies performed in the last decade all used the LifePort machine and confirmed that HMP reduces the incidence of DGF in the modern era (5 studies, 1355 participants: RR 0.77, 95% CI 0.66 to 0.91; P = 0.002; high certainty evidence). Reports of economic analysis suggest that HMP can lead to cost savings in both the North American and European settings.Two studies reported HMP also improves graft survival however we were not able to meta-analyse these results. A reduction in incidence of PNF could not be demonstrated. The effect of HMP on our other outcomes (incidence of acute rejection, patient survival, hospital stay, long-term graft function, duration of DGF) remains uncertain. AUTHORS' CONCLUSIONS: HMP is superior to SCS in deceased donor kidney transplantation. This is true for both DBD and DCD kidneys, and remains true in the modern era (studies performed in the last decade). As kidneys from DCD donors have a higher overall DGF rate, fewer perfusions are needed to prevent one episode of DGF (7.26 versus 13.60 in DBD kidneys).Further studies looking solely at the impact of HMP on DGF incidence are not required. Follow-up reports detailing long-term graft survival from participants of the studies already included in this review would be an efficient way to generate further long-term graft survival data.Economic analysis, based on the results of this review, would help cement HMP as the standard preservation method in deceased donor kidney transplantation.RCTs investigating (sub)NMP are required.


Assuntos
Rim , Preservação de Órgãos/métodos , Perfusão/métodos , Refrigeração/métodos , Doadores de Tecidos , Função Retardada do Enxerto , Rejeição de Enxerto/epidemiologia , Sobrevivência de Enxerto , Humanos , Incidência , Transplante de Rim/mortalidade , Preservação de Órgãos/instrumentação , Perfusão/instrumentação , Ensaios Clínicos Controlados Aleatórios como Assunto , Refrigeração/instrumentação , Fatores de Tempo
5.
JOP ; 13(2): 199-204, 2012 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-22406601

RESUMO

CONTEXT: There is paucity of data on the prognostic value of pre-operative inflammatory response and post-operative lymph node ratio on patient survival after pancreatic-head resection for pancreatic ductal adenocarcinoma. OBJECTIVES: To evaluate the role of the preoperative inflammatory response and postoperative pathology criteria to identify predictive and/or prognostic variables for pancreatic ductal adenocarcinoma. DESIGN: All patients who underwent pancreaticoduodenectomy for pancreatic ductal adenocarcinoma between 2002 and 2008 were reviewed retrospectively. The following impacts on patient survival were assessed: i) preoperative serum CRP levels, white cell count, neutrophil count, neutrophil/lymphocyte ratio, lymphocyte count, platelet/lymphocyte ratio; and ii) post-operative pathology criteria including lymph node status and lymph node ratio. RESULTS: Fifty-one patients underwent potentially curative resection for pancreatic ductal adenocarcinoma during the study period. An elevated preoperative CRP level (greater than 3 mg/L) was found to be a significant adverse prognostic factor (P=0.015) predicting a poor survival, whereas white cell count (P=0.278), neutrophil count (P=0.850), neutrophil/lymphocyte ratio (P=0.272), platelet/lymphocyte ratio (P=0.532) and lymphocyte count (P=0.721) were not significant prognosticators at univariate analysis. Presence of metastatic lymph nodes did not adversely affect survival (P=0.050), however a raised lymph node ratio predicted poor survival at univariate analysis (P<0.001). The preoperative serum CRP level retained significance at multivariate analysis (P=0.011), together with lymph node ratio (P<0.001) and tumour size (greater than 2 cm; P=0.008). CONCLUSION: A pre-operative elevated serum CRP level and raised post-operative lymph node ratio represent significant independent prognostic factors that predict poor prognosis in patients undergoing curative resection for pancreatic ductal adenocarcinoma. There is potential for future neo-adjuvant and adjuvant treatment strategies in pancreatic cancer to be tailored based on preoperative and postoperative factors that predict a poor survival.


Assuntos
Proteína C-Reativa/metabolismo , Carcinoma Ductal Pancreático/mortalidade , Carcinoma Ductal Pancreático/cirurgia , Linfonodos/patologia , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia/mortalidade , Adenocarcinoma/imunologia , Adenocarcinoma/mortalidade , Adenocarcinoma/cirurgia , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Biópsia , Proteína C-Reativa/imunologia , Carcinoma Ductal Pancreático/imunologia , Bases de Dados Factuais/estatística & dados numéricos , Feminino , Humanos , Estimativa de Kaplan-Meier , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/imunologia , Período Pós-Operatório , Valor Preditivo dos Testes , Período Pré-Operatório , Prognóstico
6.
Food Chem Toxicol ; 136: 111069, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31883992

RESUMO

Ionic liquids are a diverse range of charged chemicals with low volatility and often liquids at ambient temperatures. This characteristic has in part lead to them being considered environmentally-friendly replacements for existing volatile solvents. However, methylimidazolium ionic liquids are slow to break down in the environment and a recent study at Newcastle detected 1 octyl 3 methylimidazolium (M8OI) - an 8 carbon variant methylimidazolium ionic liquid - in soils in close proximity to a landfill site. The current M8OI toxicity database in cultured mammalian cells, in experimental animal studies and in model indicators of environmental impact are reviewed. Selected analytical data from the Newcastle study suggest the soils in close proximity to the landfill site, an urban soil lacking overt contamination, had variable levels of M8OI. The potential for M8OI - or a structurally related ionic liquid - to trigger primary biliary cholangitis (PBC), an autoimmune liver disease thought to be triggered by an unknown agent(s) in the environment, is reviewed.


Assuntos
Imidazóis/toxicidade , Líquidos Iônicos/toxicidade , Fígado/efeitos dos fármacos , Animais , Linhagem Celular , Humanos
7.
World J Transplant ; 9(5): 94-102, 2019 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-31598468

RESUMO

Managing blood loss in Jehovah's Witness (JW) patients is a matter of controversy. These patients will not accept transfusions of red blood cells, white blood cells, platelets or plasma, even if that is required to save their lives. There are many discussions regarding safety of operating upon JW patients in general surgical procedures, but in solid organ transplantation there is a paucity of literature on this subject. We have reviewed individual case reports and small series documenting on experience with solid organ transplantation in JW patients and the strategies adopted to facilitate that. It is clear that such patients require the surgical team to dedicate more time to ensure their safe management. This begins with a thorough, detailed consent of exactly which products and interventions they will or will not accept. Planning must begin weeks before surgery if possible. Each case must be assessed individually, but provided they meet fitness requirements, there are no absolute contraindications to abdominal organ transplantation.

8.
Surg Endosc ; 22(12): 2564-70, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18814007

RESUMO

INTRODUCTION: Reduction in hospital stay, blood loss, postoperative pain and complications are common findings after laparoscopic liver resection, suggesting that the laparoscopic approach may be a suitable alternative to open surgery. Some concerns have been raised regarding cost effectiveness of this procedure and potential implications of its large-scale application. Our aim has been to determine cost effectiveness of laparoscopic liver surgery by a case-matched, case-control, intention-to-treat analysis of its costs and short-term clinical outcomes compared with open surgery. METHODS: Laparoscopic liver segmentectomies and bisegmentectomies performed at Ninewells Hospital and Medical School between 2005 and 2007 were considered. Resections involving more than two Couinaud segments, or involving any synchronous procedure, were excluded. An operation-magnitude-matched control group was identified amongst open liver resections performed between 2004 and 2007. Hospital costs were obtained from the Scottish Health Service Costs Book (ISD Scotland) and average national costs were calculated. Cost of theatre time, disposable surgical devices, hospital stay, and high-dependency unit (HDU) and intensive care unit (ICU) usage were the main endpoints for comparison. Secondary endpoints were morbidity and mortality. Statistical analysis was performed with Student's t-test, chi(2) and Fisher exact test as most appropriate. RESULTS: Twenty-five laparoscopic liver resections were considered, including atypical resection, segmentectomy and bisegmentectomy, and they were compared to 25 matching open resections. The two groups were homogeneous by age, sex, coexistent morbidity, magnitude of resection, prevalence of liver cirrhosis and indications. Operative time (p < 0.03), blood loss (p < 0.0001), Pringle manoeuvre (p < 0.03), hospital stay (p < 0.003) and postoperative complications (p < 0.002) were significantly reduced in the laparoscopic group. Overall hospital cost was significantly lower in the laparoscopic group by an average of 2,571 pounds sterling (p < 0.04). CONCLUSIONS: Laparoscopic liver segmentectomy and bisegmentectomy are feasible, safe and cost effective compared to similar open resections. Large-scale application of laparoscopic liver surgery could translate into significant savings to hospitals and health care programmes.


Assuntos
Hepatectomia/métodos , Laparoscopia/métodos , Idoso , Perda Sanguínea Cirúrgica/prevenção & controle , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Estudos de Casos e Controles , Análise Custo-Benefício , Feminino , Hepatectomia/economia , Hepatectomia/estatística & dados numéricos , Custos Hospitalares/estatística & dados numéricos , Humanos , Período Intraoperatório/estatística & dados numéricos , Laparoscopia/economia , Laparoscopia/estatística & dados numéricos , Laparotomia/economia , Laparotomia/estatística & dados numéricos , Tempo de Internação/economia , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/prevenção & controle , Estudos Prospectivos , Escócia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA