Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(7)2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38610543

RESUMO

In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.

2.
Sensors (Basel) ; 23(9)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37177414

RESUMO

The decommissioning of nuclear installations, as well as the possible necessary accident remediations, requires the physical presence of human operators in potentially radiologically hostile environments. The number of active nuclear reactors worldwide is greater than 400, and most of them are 40 to 50 years old, thus implying that soon they will have to be dismantled. In the framework of the H2020 CLEANDEM project, a small robotic vehicle is being developed that is equipped with a series of different sensors for areas that are significantly contaminated by radiation. In this work, we describe the MiniRadMeter system, a compact low-cost sensor capable of being used to perform quick gamma and neutron radiation field mapping of environments prior to the possible start of human operations. The miniature gamma sensor is a 1 cm3 scintillator counter with moderate spectroscopic features read out by means of a 6 × 6 mm2 SiPM, whereas neutrons are detected by means of a silicon diode coupled to a layer of 6LiF and placed inside a 6 × 6 × 6 cm3 polyethylene box. The front-end and data acquisition electronics were developed based on a Raspberry Pi4 microcomputer. In this paper, the system performance and the preliminary test results are described.

3.
Sensors (Basel) ; 23(24)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38139677

RESUMO

The shortage of 3He, a crucial element widely used as a neutron converter in neutron detection applications, has sparked significant research efforts aimed at finding alternative materials, developing appropriate deposition methods, and exploring new detector architectures. This issue has required the exploration of novel approaches to address the challenges faced in neutron detection. Among the available conversion materials, 10B has emerged as one of the most promising choices due to its high neutron-capture cross-section and relatively high Q value. In our previous papers, we delved into the possibility of depositing neutron conversion layers based on 10B using Pulsed Laser Deposition (PLD). We investigated and evaluated the performance of these layers based on various factors, including deposition conditions, substrate properties, and film thickness. Moreover, we successfully developed and tested a device that employed a single conversion layer coupled with a silicon particle detector. In this current study, we present the development of a new device that showcases improved performance in terms of efficiency, sensitivity, and discrimination against γ background signals. The background signals can arise from the environment or be associated with the neutron field. To achieve these advancements, we considered a new detection geometry that incorporates the simultaneous use of two 10B conversion layers, each with a thickness of 1.5 µm, along with two solid-state silicon detectors. The primary objective of this design was to enhance the overall detection efficiency when compared to the single-layer geometry. By employing this novel setup, our results demonstrate a significant enhancement in the device's performance when exposed to a neutron flux from an Am-Be neutron source, emitting a flux of approximately 2.2 × 106 neutrons per second. Furthermore, we established a noteworthy agreement between the experimental data obtained and the simulation results.

4.
Sensors (Basel) ; 22(13)2022 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-35808247

RESUMO

In the framework of radioactive material handling, such as in radwaste sorting and segregation operations, the availability of a simple tool to quickly detect and locate gamma radiation spots can be quite convenient. Additional spectroscopic features, even with moderate energy resolutions, could provide a useful benefit. As a proof of principle for such a tool, we developed a gamma detector prototype featuring an array of 10 × 10 CsI(Tl) scintillators (1 × 1 × 1 cm3) providing readouts by means of a corresponding array of 6 × 6 mm2 silicon photo multipliers (SiPM). Such a detector table could be easily incorporated into a work desk for quick scanning of possibly radioactive objects. The proposed detector has a good counting efficiency and energy resolution, while the simulations and tests show interesting hot-spot localization capabilities.


Assuntos
Tomografia por Emissão de Pósitrons , Silício , Raios gama , Decoração de Interiores e Mobiliário , Contagem de Cintilação , Análise Espectral
5.
Sensors (Basel) ; 21(8)2021 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-33918061

RESUMO

In the framework of the MICADO (Measurement and Instrumentation for Cleaning And Decommissioning Operations) European Union (EU) project, aimed at the full digitization of low- and intermediate-level radioactive waste management, a set of 32 solid state thermal neutron detectors named SiLiF has been built and characterized. MICADO encompasses a complete active and passive characterization of the radwaste drums with neutrons and gamma rays, followed by a longer-term monitoring phase. The SiLiF detectors are suitable for the monitoring of nuclear materials and can be used around radioactive waste drums possibly containing small quantities of actinides, as well as around spent fuel casks in interim storage or during transportation. Suitable polyethylene moderators can be exploited to better shape the detector response to the expected neutron spectrum, according to Monte Carlo simulations that were performed. These detectors were extensively tested with an AmBe neutron source, and the results show a quite uniform and reproducible behavior.

6.
Inorg Chem ; 51(15): 8409-18, 2012 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-22799598

RESUMO

This contribution explores the aggregation properties in solution of noncoordinating solvents of a series of amphiphilic Zn(salen) derivatives, through detailed (1)H NMR, DOSY NMR, and optical absorption spectroscopic studies. It is found that these aggregate species are involved in a unique structural interconversion between two defined dimers, A and B, driven by the concentration of water dissolved in chloroform. Dilute CHCl(3) solutions are characterized by the presence of dimeric species, A, in which both Zn(II) atoms of the Zn(salen) units mutually interact through a Zn···O axial coordination, likely adopting a square-base pyramidal structure. Investigations to higher concentrations indicate the existence of a new dimeric species, B, in equilibrium to that observed at lower concentrations, involving a coordination mode interconversion of an intermediate monomer presumably from a square-pyramidal to a trigonal bipyramidal structure. This behavior may be related to the nonconjugated, conformational flexible nature of the bridging diamine of the Schiff base, and is influenced by the solvent polarity. Variable-temperature (1)H NMR studies indicate the existence of a nonequivalent species B' in a fluxional equilibrium with species B.

7.
Inorg Chem ; 49(11): 5134-42, 2010 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-20459126

RESUMO

The synthesis, characterization, optical, and fluorescent properties of an amphiphilic Schiff-base bis(salicylaldiminato)zinc(II) complex are reported. Detailed (1)H nuclear magnetic resonance (NMR), diffusion-ordered spectroscopy (DOSY) NMR, optical absorption, and fluorescence spectroscopy studies indicate the existence of aggregate species in noncoordinating solvents. The degree and type of aggregation are related to the concentration and the polarity of the noncoordinating solvent. Dilute solutions are likely characterized by the presence of defined dimers, whereas larger oligomeric aggregates are conceivably formed at higher concentrations. The concentration needed to observe the formation of larger species depends upon solvent polarity. In coordinating solvents or in the presence of coordinating species, a complete deaggregation of the system occurs, because of the axial coordination to the Zn(II) ion, accompanied by considerable changes of (1)H NMR and optical absorption spectra. A dramatic enhancement of fluorescence emission is observed in dichloromethane solutions upon deaggregation with a coordinating agent. The formation of a defined 2:1 supramolecular structure is demonstrated in the case of a ditopic ligand as coordinating species. Overall, these complexes are promising systems for the development of new supramolecular architectures and supramolecular fluorescent probes.


Assuntos
Compostos Organometálicos/síntese química , Zinco/química , Substâncias Macromoleculares/síntese química , Substâncias Macromoleculares/química , Estrutura Molecular , Compostos Organometálicos/química , Bases de Schiff/química
8.
Sensors (Basel) ; 8(8): 4636-4655, 2008 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-27873777

RESUMO

Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs). Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

9.
Molecules ; 13(3): 678-700, 2008 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-18463570

RESUMO

We have synthetized medium-sized cyclophanes and macrocycles containing phosphonic groups, directly linked to the aromatic rings of the phanes or as pendant arms,for use as specific receptors for the selective complexation of neutral guests or for complexing lanthanides, as luminescent sensors and for diagnostic bioassays in medicine.Furthermore, because it would be of great interest for biochemistry as well as for pharmacological studies to dispose of preorganized rigid chiral hosts for biorelevant molecules we designed inter alia, some new chiral macrocycles capable of a triple binding mode and we used them for constructing macrocycles that could also be of interest for chiral recognition and chiral separations. Thus, in this paper we shall review the salient aspects of some macrocycles synthetized in our laboratory, all possessing the phosphonate moiety and a spirobisindanol scaffold and able to act as complexing agents for cations and organic substrates. In particular, we shall describe their NMR characterization, their stereochemistry in solution and in the solid state, and their use as chiral receptors for biorelevant molecules. Chiral HPLC resolution of some of them is also reported.


Assuntos
Indanos/química , Compostos Macrocíclicos/síntese química , Organofosfonatos/química , Compostos de Espiro/química , Elementos da Série dos Lantanídeos/química , Compostos Macrocíclicos/química , Espectroscopia de Ressonância Magnética , Estereoisomerismo
10.
Rev Sci Instrum ; 84(3): 033503, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23556817

RESUMO

A semiconductor detector coupled with a neutron converter is a good candidate for neutron detection, especially for its compactness and reliability if compared with other devices, such as (3)He tubes, even though its intrinsic efficiency is rather lower. In this paper we show a neutron detector design consisting of a 3 cm × 3 cm silicon pad detector coupled with one or two external (6)LiF layers, enriched in (6)Li at 95%, placed in contact with the Si active surfaces. This prototype, first characterized and tested at INFN Laboratori Nazionali del Sud and then at JRC Ispra, was successfully shown to detect thermal neutrons with the expected efficiency and an outstanding gamma rejection capability.

11.
Rev Sci Instrum ; 83(11): 114301, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206076

RESUMO

We report on the measurements performed using a (22)Na source on a detector element for a magnetic resonance imaging-compatible time-of-flight-positron emission tomography endorectal prostate probe, with depth-of-interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with Lumirror, readout at both ends by means of silicon photomultipliers. With a detailed description of the data analysis procedure, we show that our results point to a 400 ps coincidence resolving time and, at the same time, to a depth-of-interaction resolution of 1 mm. These appealing features, along with the tiny 1.5 mm × 1.5 mm × 10 mm crystal size, are quite promising in view of the realization of a prototype probe.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Próstata/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Masculino , Radioisótopos de Sódio , Fatores de Tempo
12.
Rev Sci Instrum ; 83(8): 084302, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22938315

RESUMO

By exploiting a suitable treatment of the scintillator surfaces, along with silicon photomultiplier photodetectors and specific algorithms for raw data analysis, we achieved a remarkable tradeoff between energy, time, and depth-of-interaction (DOI) resolution, thus supporting the feasibility of a prostate time-of-flight positron emission tomography probe, magnetic resonance imaging compatible, with the required features and performance. In numbers this means a detector element of 1.5 mm × 1.5 mm × 10 mm, promising to achieve at the same time energy resolution around 11.5%, coincidence resolving time around 300 ps corresponding to a space resolution <5 cm along the line of response, and DOI resolution even below 1 mm. We stress that such a time resolution allows to increase significantly the noise equivalent counting rate, and consequently improve the image quality and the lesion detection capability.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Contagem de Cintilação/instrumentação , Algoritmos , Estudos de Viabilidade , Estatística como Assunto , Fatores de Tempo
13.
Dalton Trans ; 41(2): 387-95, 2012 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-22005842

RESUMO

The synthesis, characterization, (1)H NMR, optical absorption and fluorescent properties of a series of amphiphilic Schiff-base bis(salicylaldiminato)zinc(II) complexes are reported. Detailed (1)H NMR, DOSY NMR, optical absorption and fluorescence spectroscopy studies indicate the existence of aggregate species in solutions of non-coordinating solvents. The degree of aggregation is related to the nature of the bridging diamine. Chloroform solutions of complexes where the bridging diamine contains a naphthalene or the pyridine nucleus are always characterized by the presence of defined dimer aggregates, whereas oligomeric aggregates are likely formed by complexes where the bridging diamine contains a benzene ring. In coordinating solvents or in the presence of coordinating species, a complete deaggregation of the complexes occurs, because of the axial coordination to the Zn(II) ion, accompanied by considerable changes in the (1)H NMR and optical absorption spectra. The effect of the alkyl chains length seems to play a minor role in the aggregation properties, as noticed by (1)H NMR data, optical absorption and fluorescence spectra, which remain almost unaltered on changing the chain length.


Assuntos
Ácidos de Lewis/química , Compostos Organometálicos/química , Bases de Schiff/química , Tensoativos/síntese química , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Compostos Organometálicos/síntese química , Solubilidade , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta , Tensoativos/química
14.
Rev Sci Instrum ; 81(3): 033308, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20370171

RESUMO

Triggered by the need of a detection system to be used in experiments of nuclear fusion in laser-generated plasmas, we developed an imaging technique for the measurement and calibration of the scintillation light yield of scintillating materials. As in such experiments, all the reaction products are generated in an ultrashort time frame, the event-by-event data acquisition scheme is not feasible. As an alternative to the emulsion technique (or the equivalent CR39 sheets) we propose a scintillating screen readout by means of a high performance charge coupled device camera. Even though it is not strictly required in the particular application, this technique allows the absolute calibration of the scintillation light yield.

15.
Rev Sci Instrum ; 81(10): 103302, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034082

RESUMO

In order to investigate the limits of scintillating screens for beam profile monitoring in the ultra-low energy, ultra-low intensity regime, CsI:Tl, YAG:Ce, and a Tb glass-based scintillating fiber optic plate (SFOP) were tested. The screens response to 200 and 50 keV proton beams with intensities ranging from a few picoampere down to the subfemtoampere region was examined. In the following paper, the sensitivity and resolution studies are presented in detail for CsI:Tl and the SFOP, the two most sensitive screens. In addition, a possible use of scintillators for ultra-low energy antiproton beam monitoring is discussed.

16.
Rev Sci Instrum ; 81(9): 093503, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20886978

RESUMO

We propose a technique for thermal neutron detection, based on a (6)Li converter placed in front of scintillating fibers readout by means of silicon photomultipliers. Such a technique allows building cheap and compact detectors and dosimeters, thus possibly opening new perspectives in terms of granular monitoring of neutron fluxes as well as space-resolved neutron detection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA