Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 48(9): 2210-2213, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37126236

RESUMO

We report a precision realization of photonic thermometry using dual-comb spectroscopy to interrogate a π-phase-shifted fiber Bragg grating. We achieve readout stability of 7.5 mK at 1 s and resolve temperature changes of similar magnitude-sufficient for most industrial applications. Our dual-comb approach enables rapid sensing of dynamic temperature, and our scalable and reconfigurable electro-optic generation scheme enables a broad sensing range without laser tuning. Reproducibility on the International Temperature Scale of 1990 is tested, and ultimately limited by the frequency reference and check-thermometer stability. Our demonstration opens the door for a universal interrogator deployable to multiple photonic devices in parallel to potentially unravel complex multi-physical quantity measurements.

2.
Faraday Discuss ; 245(0): 368-379, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37306220

RESUMO

We report direct frequency comb spectroscopy of the 2ν1 band of H13CN in the short-wave infrared (λ = 1.56 µm) towards experimental validation of molecular line lists that support observatories like JWST. The laboratory measurements aim to test spectral reference data generated from an experimentally accurate potential energy surface (PES) and an ab initio dipole moment surface (DMS) calculated from quantum chemistry theory. Benchmarking theory with experiment will improve confidence in new astrophysics and astrochemistry inferred from spectroscopic observations of HCN and HNC. Here we describe our instrumentation and initial results using a cross-dispersed spectrometer with a virtually imaged phased array (VIPA).

3.
Opt Express ; 29(17): 26831-26840, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34615110

RESUMO

A simple and universal technique for performing optical feedback cavity enhanced absorption spectroscopy with a linear Fabry-Pérot cavity is presented. We demonstrate through both theoretical analysis and experiment that a diode laser can be sequentially stabilized to a series of cavity modes without any influence from the direct reflection if the feedback phase is appropriately controlled. With robust handling of the feedback phase and help from balanced detection, a detection limit of 1.3 × 10-9 cm-1 was achieved in an integration time of 30 s. The spectrometer performance enabled precision monitoring of atmospheric methane (CH4) concentrations over a time period of 72 h.

4.
Opt Lett ; 46(13): 3057-3060, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34197378

RESUMO

Frequency-stabilized mid-infrared lasers are valuable tools for precision molecular spectroscopy. However, their implementation remains limited by complicated stabilization schemes. Here we achieve optical self-locking of a quantum cascade laser to the resonant leak-out field of a highly mode-matched two-mirror cavity. The result is a simple approach to achieving stable frequencies from high-powered mid-infrared lasers. For short time scales (<0.1ms), we report a linewidth reduction factor of 3×10-6 to a linewidth of 12 Hz. Furthermore, we demonstrate two-photon cavity-enhanced absorption spectroscopy of an N2O overtone transition near a wavelength of 4.53 µm.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36452911

RESUMO

Using frequency-agile rapid scanning cavity ring-down spectroscopy, we measured line intensities and line shape parameters of 14N2 16O in air in the (4200)←(0000) and (5000)←(0000) bands near 1.6 µm. The absorption spectra were modeled with multi-spectrum fits of Voigt and speed-dependent Voigt profiles. The measured line intensities and air-broadening parameters exhibit deviations of several percent relative to values provided in HITRAN 2016. Our measured intensities for these two bands have relative combined standard uncertainties of ∼1% which is approximately five times smaller than literature values. Comparison of the present air-broadening and speed-dependent broadening parameters to experimental literature values for other rotation-vibration bands of N2O indicates significant differences in magnitude and J-dependence. For applications requiring high spectral fidelity, these results suggest that the assumption of band-independent line shape parameters is not appropriate.

6.
Artigo em Inglês | MEDLINE | ID: mdl-37554518

RESUMO

This paper outlines the major updates of the line-shape parameters that were performed for the nitrous oxide (N2O) and carbon monoxide (CO) molecules listed in the HITRAN2020 database. We reviewed the collected measurements for the air- and self-broadened N2O and CO spectra to determine proper values for the spectroscopic parameters. Careful comparisons of broadening parameters using the Voigt and speed-dependent Voigt line-shape profiles were performed among various published results for both N2O and CO. Selected data allowed for developing semi-empirical models, which were used to extrapolate/interpolate existing data to update broadening parameters of all the lines of these molecules in the HITRAN database. In addition to the line broadening parameters (and their temperature dependences), the pressure shift values were revised for N2O and CO broadened by air and self for all the bands. The air and self speed-dependence of the broadening parameter for these two molecules were added for every transition as well. Furthermore, we determined the first-order line-mixing parameters using the Exponential Power Gap (EPG) scaling law. These new parameters are now available at HITRAN online.

7.
Anal Chem ; 92(20): 13759-13766, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-32942855

RESUMO

As a potent greenhouse gas and an ozone-depleting agent, nitrous oxide (N2O) plays a critical role in the global climate. Effective mitigation relies on understanding global sources and sinks, which can be supported through isotopic analysis. We present a cross-dispersed spectrometer, coupled with a mid-infrared frequency comb, capable of simultaneously monitoring all singly substituted, stable isotopic variants of N2O. Rigorous evaluation of the instrument lineshape function and data treatment using a Doppler-broadened, low-pressure gas sample are discussed. Laboratory characterization of the spectrometer demonstrates sub-GHz spectral resolution and an average precision of 6.7 × 10-6 for fractional isotopic abundance retrievals in 1 s.

8.
Opt Express ; 28(13): 19571-19573, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32672231

RESUMO

This joint feature issue of Optics Express and Applied Optics highlights contributions from authors who presented their latest research at the OSA Optical Sensors and Sensing Congress, held in San Jose, California, USA from 25-27 June 2019. The joint feature issue comprises 6 contributed papers, which expand upon their respective conference proceedings. The published papers introduced here cover a range of timely research topics in optics and photonics for active open-path sensing, radiometry, and adaptive optics and fiber devices.

9.
Brain ; 142(6): 1723-1735, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31009046

RESUMO

The advent of tau-targeted PET tracers such as flortaucipir (18F) (flortaucipir, also known as 18F-AV-1451 or 18F-T807) have made it possible to investigate the sequence of development of tau in relationship to age, amyloid-ß, and to the development of cognitive impairment due to Alzheimer's disease. Here we report a multicentre longitudinal evaluation of the relationships between baseline tau, tau change and cognitive change, using flortaucipir PET imaging. A total of 202 participants 50 years old or older, including 57 cognitively normal subjects, 97 clinically defined mild cognitive impairment and 48 possible or probable Alzheimer's disease dementia patients, received flortaucipir PET scans of 20 min in duration beginning 80 min after intravenous administration of 370 MBq flortaucipir (18F). On separate days, subjects also received florbetapir amyloid PET imaging, and underwent a neuropsychological test battery. Follow-up flortaucipir scans and neuropsychological battery assessments were also performed at 9 and 18 months. Fifty-five amyloid-ß+ and 90 amyloid-ß- subjects completed the baseline and 18-month study visits and had valid quantifiable flortaucipir scans at both time points. There was a statistically significant increase in the global estimate of cortical tau burden as measured by standardized uptake value ratio (SUVr) from baseline to 18 months in amyloid-ß+ but not amyloid-ß- subjects (least squared mean change in flortaucipir SUVr : 0.0524 ± 0.0085, P < 0.0001 and 0.0007 ± 0.0024 P = 0.7850, respectively), and a significant association between magnitude of SUVr increase and baseline tau burden. Voxel-wise evaluations further suggested that the regional pattern of change in flortaucipir PET SUVr over the 18-month study period (i.e. which regions exhibited the greatest change) also varied as a function of baseline global estimate of tau burden. In subjects with lower global SUVr, temporal lobe regions showed the greatest flortaucipir retention, whereas in subjects with higher baseline SUVr, parietal and frontal regions were increasingly affected. Finally, baseline flortaucipir and change in flortaucipir SUVr were both significantly (P < 0.0001) associated with changes in cognitive performance. Taken together, these results provide a preliminary characterization of the longitudinal spread of tau in Alzheimer's disease and suggest that the amount and location of tau may have implications both for the spread of tau and the cognitive deterioration that may occur over an 18-month period.


Assuntos
Envelhecimento , Doença de Alzheimer/patologia , Carbolinas , Disfunção Cognitiva/patologia , Demência/patologia , Idoso , Amiloide/metabolismo , Peptídeos beta-Amiloides/metabolismo , Encéfalo/metabolismo , Encéfalo/patologia , Cognição/fisiologia , Transtornos Cognitivos/patologia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Proteínas tau/metabolismo
10.
Appl Opt ; 59(7): OSS1-OSS2, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32225749

RESUMO

This joint feature issue of Optics Express and Applied Optics highlights contributions from authors who presented their latest research at the OSA Optical Sensors and Sensing Congress, held in San Jose, California, USA, from 25-27 June 2019. The joint feature issue comprises six contributed papers, which expand upon their respective conference proceedings. The published papers introduced here cover a range of timely research topics in optics and photonics for active open-path sensing, radiometry, and adaptive optics and fiber devices.

11.
Artigo em Inglês | MEDLINE | ID: mdl-33100382

RESUMO

The λ = 2.06 µm absorption band of CO2 is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overcome accuracy limitations of existing line lists, we used frequency-stabilized cavity ring-down spectroscopy to measure 39 transitions in the 12C16O2 absorption band. The line intensities were measured with an estimated relative combined standard uncertainty of u r = 0.08 %. We predicted the J-dependence of the measured intensities using two theoretical models: a one-dimensional spectroscopic model with Herman-Wallis rotation-vibration corrections, and a line-by-line ab initio dipole moment surface model [Zak et al. JQSRT 2016;177:31-42]. For the second approach, we fit only a single factor to rescale the theoretical integrated band intensity to be consistent with the measured intensities. We find that the latter approach yields an equally adequate representation of the fitted J-dependent intensity data and provides the most physically general representation of the results. Our recommended value for the integrated band intensity equal to 7.183 × 10-21 cm molecule-1 ± 6 × 10-24 cm molecule-1 is based on the rescaled ab initio model and corresponds to a fitted scale factor of 1.0069 ± 0.0002. Comparisons of literature intensity values to our results reveal systematic deviations ranging from -1.16 % to +0.33 %.

12.
Opt Express ; 27(12): A856-A859, 2019 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-31252859

RESUMO

This joint feature issue of Optics Express and Applied Optics highlights contributions from authors who presented their latest research at the OSA Light, Energy and the Environment Congress, held in Sentosa Island, Singapore from 5 to 8 November 2018. The joint feature issue comprises 11 contributed papers, which expand upon their respective conference proceedings. The published papers introduced here cover a broad range of timely research topics in optics and photonics for lighting and illumination, solar energy, hyperspectral imaging, and environmental sensing.

13.
Opt Lett ; 44(17): 4415-4418, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31465415

RESUMO

An approach for dual-comb spectroscopy using electro-optic (EO) phase modulation is reported. Maximum-length pseudo-random binary sequences allow for energy-efficient and flexible comb generation. Self-correction of interferograms is shown to remove relative comb drifts and improve mutual coherence, even for EO combs derived from the same laser source. Methane spectroscopy is reported over a ∼10 GHz spectral range, limited by the modulators' bandwidth. The potential of a simple EO comb instrument is demonstrated to rapidly quantify atmospheric methane emissions with ppb precision over 1 km.

14.
Phys Rev Lett ; 123(4): 043001, 2019 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-31491247

RESUMO

To accurately attribute sources and sinks of molecules like CO_{2}, remote sensing missions require line intensities (S) with relative uncertainties u_{r}(S)<0.1%. However, discrepancies in S of ≈1% are common when comparing different experiments, thus limiting their potential impact. Here we report a cavity ring-down spectroscopy multi-instrument comparison which revealed that the hardware used to digitize analog ring-down signals caused variability in spectral integrals which yield S. Our refined approach improved measurement accuracy 25-fold, resulting in u_{r}(S)=0.06%.

15.
J Chem Phys ; 151(23): 234202, 2019 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-31864246

RESUMO

Reported here are portions of the infrared absorption cross section for methanol (CH3OH), as measured by frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) at wavelengths near λ = 2.0 µm. High-resolution spectra of two gravimetric mixtures of CH3OH-in-air with nominal mole fractions of 202.2 µmol/mol and 45.89 µmol/mol, respectively, were recorded at pressures between 0.8 kPa and 102 kPa and at a temperature of 298 K. Covering the experimental wavenumber range of 4990 cm-1 to 5010 cm-1 in increments of 0.0067 cm-1 and with an instrument linewidth of 30 kHz, we observed an evolution in the CH3OH spectrum from resolved absorption lines at a low pressure (0.833 kPa) to a pseudocontinuum of absorption at a near-atmospheric pressure (101.575 kPa). An analysis of resolvable features at the lowest recorded pressure yielded a minimum intramolecular vibrational energy redistribution (IVR) lifetime for the OH-stretch (ν1) plus OH-bend (ν6) combination of τIVR ≥ 232 ps-long compared to other methanol overtones and combinations. Consequently, we show that high-resolution FS-CRDS of this relatively weak CH3OH combination band provided an additional avenue by which to study the intramolecular dynamics of this simplest organic molecule with hindered internal rotation.

16.
Appl Opt ; 58(15): LEE1-LEE3, 2019 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-31158145

RESUMO

This joint feature issue of Optics Express and Applied Optics highlights contributions from authors who presented their latest research at the OSA Light, Energy and the Environment Congress, held in Sentosa Island, Singapore from 5-8 November 2018. The joint feature issue comprises 11 contributed papers, which expand upon their respective conference proceedings. The published papers introduced here cover a broad range of timely research topics in optics and photonics for lighting and illumination, solar energy, hyperspectral imaging, and environmental sensing.

17.
Opt Lett ; 43(6): 1407-1410, 2018 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-29543247

RESUMO

We demonstrate the precision molecular spectroscopy of H13CN using a free-running, all-fiber dual electro-optic frequency comb system. Successive interferograms, acquired at a rate of Δfrep=1 MHz, were phase-corrected in post-processing, averaged, and normalized to yield the complex transmission spectrum of several transitions within the 2ν1H13CN band centered near λ=1545 nm. With spectral signal-to-noise ratios as high as 326:1 achieved in 2 ms of integration time, we report accurate measurements of H13CN transition intensities which will aid in the study of extreme astrophysical environments.

19.
BMC Geriatr ; 18(1): 243, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30326851

RESUMO

BACKGROUND: The objective of this study was to examine patient characteristics and health care resource utilization (HCRU) in the 36 months prior to a confirmatory diagnosis of Alzheimer's disease (AD) compared to a matched cohort without dementia during the same time interval. METHODS: Patients newly diagnosed with AD (with ≥2 claims) were identified between January 1, 2013 to September 31, 2015, and the date of the second claim for AD was defined as the index date. Patients were enrolled for at least 36 months prior to index date. The AD cohort was matched to a cohort with no AD or dementia codes (1:3) on age, gender, race/ethnicity, and enrollment duration prior to the index date. Descriptive analyses were used to summarize patient characteristics, HCRU, and healthcare costs prior to the confirmatory AD diagnosis. The classification and regression tree analysis and logistic regression were used to identify factors associated with the AD diagnosis. RESULTS: The AD cohort (N = 16,494) had significantly higher comorbidity indices and greater odds of comorbid mental and behavioral diagnoses, including mild cognitive impairment, mood and anxiety disorders, behavioral disturbances, and cerebrovascular disease, heart disease, urinary tract infections, and pneumonia than the matched non-AD or dementia cohort (N = 49,482). During the six-month period before the confirmatory AD diagnosis, AD medication use and diagnosis of mild cognitive impairment, Parkinson's disease, or mood disorder were the strongest predictors of a subsequent confirmatory diagnosis of AD. Greater HCRU and healthcare costs were observed for the AD cohort primarily during the six-month period before the confirmatory AD diagnosis. CONCLUSION: The results of this study demonstrated a higher comorbidity burden and higher costs for patients prior to a diagnosis of AD in comparison to the matched cohort. Several comorbidities were associated with a subsequent diagnosis of AD.


Assuntos
Demandas Administrativas em Assistência à Saúde/economia , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/economia , Bases de Dados Factuais/economia , Aceitação pelo Paciente de Cuidados de Saúde , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/epidemiologia , Transtornos de Ansiedade/diagnóstico , Transtornos de Ansiedade/economia , Transtornos de Ansiedade/epidemiologia , Estudos de Coortes , Bases de Dados Factuais/tendências , Feminino , Custos de Cuidados de Saúde/tendências , Humanos , Masculino , Estudos Retrospectivos
20.
J Quant Spectrosc Radiat Transf ; 206: 367-377, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29731521

RESUMO

Reported here are highly accurate, experimentally measured ro-vibrational transition intensities for the R-branch of the (20012) - (00001) 12C16O2 band near λ = 2 µm. Measurements were performed by a frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) instrument designed to achieve precision molecular spectroscopy in this important region of the infrared. Through careful control and traceable characterization of CO2 sample conditions, and through high-fidelity measurements spanning several months in time, we achieve relative standard uncertainties for the reported transition intensities between 0.15 % and 0.46 %. Such high accuracy spectroscopy is shown to provide a stringent test of calculated potential energy and ab initio dipole moment surfaces, and therefore transition intensities calculated from first principles.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA