1.
J Clin Densitom ; 18(2): 209-16, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25087044

RESUMO

Total body (TB) dual-energy X-ray absorptiometry (DXA) is increasingly being used to measure body composition in research and clinical settings. This study investigated the effect of body mass index (BMI) and body fat on precision errors for total and regional TB DXA measurements of bone mineral density, fat tissue, and lean tissue using the GE Lunar Prodigy (GE Healthcare, Bedford, UK). One hundred forty-four women with BMI's ranging from 18.5 to 45.9 kg/m(2) were recruited. Participants had duplicate DXA scans of the TB with repositioning between examinations. Participants were divided into 3 groups based on their BMI, and the root mean square standard deviation and the percentage coefficient of variation were calculated for each group. The root mean square standard deviation (percentage coefficient of variation) for the normal (<25 kg/m²; n = 76), overweight (25-30 kg/m²; n = 36), and obese (>30 kg/m²; n = 32) BMI groups, respectively, were total BMD (g/cm(2)): 0.009 (0.77%), 0.009 (0.69%), 0.011 (0.91%); total fat (g): 545 (2.98%), 486 (1.72%), 677 (1.55%); total lean (g): 551 (1.42%), 540 (1.34%), and 781 (1.68%). These results suggest that serial measurements in obese subjects should be treated with caution because the least significant change may be larger than anticipated.


Assuntos
Absorciometria de Fóton , Tecido Adiposo/diagnóstico por imagem , Densidade Óssea , Osso e Ossos/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Adolescente , Adulto , Idoso , Índice de Massa Corporal , Estudos de Casos e Controles , Feminino , Humanos , Pessoa de Meia-Idade , Sobrepeso/diagnóstico por imagem , Reprodutibilidade dos Testes , Adulto Jovem
2.
Curr Osteoporos Rep ; 12(4): 475-85, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25168931

RESUMO

The functional imaging technique of dynamic fluorine-18 labeled sodium fluoride positron emission tomography ((18)F-NaF PET) allows the quantitative assessment of regional bone formation by measuring the plasma clearance of fluoride to bone at any site in the skeleton. (18)F-NaF PET provides a novel and noninvasive method of studying site-specific bone formation at the hip and spine, as well as areas of pure cortical or trabecular bone. The technique complements conventional measurements of bone turnover using biochemical markers and bone biopsy as a tool to investigate new treatments for osteoporosis, and holds promise of a future role as an early biomarker of treatment efficacy in clinical trials. This article reviews methods of acquiring and analyzing (18)F-NaF PET scan data, and outlines a simplified approach that uses 5-minute static PET scan images combined with venous blood samples to estimate (18)F-NaF plasma clearance at multiple sites in the skeleton with a single injection of tracer.


Assuntos
Osso e Ossos/metabolismo , Osteoporose/diagnóstico por imagem , Osteoporose/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Diagnóstico por Imagem , Radioisótopos de Flúor , Humanos , Computação Matemática , Osteogênese , Fatores de Tempo
3.
Calcif Tissue Int ; 93(5): 436-47, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23995764

RESUMO

(18)F-fluoride positron emission tomography ((18)F-PET) allows the assessment of regional bone formation and could have a role in the diagnosis of adynamic bone disease (ABD) in patients with chronic kidney disease (CKD). The purpose of this study was to examine bone formation at multiple sites of the skeleton in hemodialysis patients (CKD5D) and assess the correlation with bone biopsy. Seven CKD5D patients with suspected ABD and 12 osteoporotic postmenopausal women underwent an (18)F-PET scan, and bone plasma clearance, K i, was measured at ten skeletal regions of interest (ROI). Fifteen subjects had a transiliac bone biopsy following double tetracycline labeling. Two CKD5D patients had ABD confirmed by biopsy. There was significant heterogeneity in K i between skeletal sites, ranging from 0.008 at the forearm to 0.028 mL/min/mL at the spine in the CKD5D group. There were no significant differences in K i between the two study groups or between the two subjects with ABD and the other CKD5D subjects at any skeletal ROI. Five biopsies from the CKD5D patients had single tetracycline labels only, including the two with ABD. Using an imputed value of 0.3 µm/day for mineral apposition rate (MAR) for biopsies with single labels, no significant correlations were observed between lumbar spine K i corrected for BMAD (K i/BMAD) and bone formation rate (BFR/BS), or MAR. When biopsies with single labels were excluded, a significant correlation was observed between K i/BMAD and MAR (r = 0.81, p = 0.008) but not BFR/BS. Further studies are required to establish the sensitivity of (18)F-PET as a diagnostic tool for identifying CKD patients with ABD.


Assuntos
Doenças Ósseas/diagnóstico por imagem , Fluordesoxiglucose F18 , Osteogênese , Tomografia por Emissão de Pósitrons/métodos , Diálise Renal , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/terapia , Adulto , Idoso , Densidade Óssea/fisiologia , Doenças Ósseas/etiologia , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/fisiopatologia
4.
J Clin Densitom ; 16(3): 329-335, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22717905

RESUMO

The T-score discordance among skeletal sites is an important aspect of dual-energy X-ray absorptiometry (DXA) measurements. In the spine, large T-score differences between vertebrae are frequently seen in elderly patients owing to degenerative disease. However, it is unclear how often such differences occur in younger adults with healthy spines. The T-scores for individual lumbar vertebrae were compared for 2391 female singletons (18-79 yr) recruited to the Twins UK Adult Twin Register. Women were divided into 6 age bands and 5 bands by body weight, respectively, and the T-score differences between the pairs of vertebrae were examined using correlation coefficients and the standard error of the estimate (SEE) from linear regression analysis. Correlations between the T-scores for adjacent lumbar vertebrae were r = 0.92 decreasing to r = 0.79 between L1 and L4. When plotted as a function of age, r-values were constant for the 5 younger age bands, but decreased in the oldest group. In contrast, the T-score SEE values increased progressively with age from 0.4 to 0.5 for the younger groups to 0.7 for the oldest. Similar trends were seen when women were divided according to body weight. Both increasing age and higher body weight were statistically significantly associated with a higher T-score SEE. The incidence of large T-score differences between vertebrae varies with age and body weight, but is common even among younger women. Clinically significant T-score differences can occur in the absence of osteoarthritis, and visual assessment of spine DXA scans for evidence of degenerative disease is advised before vertebrae are omitted from scan analyses.


Assuntos
Absorciometria de Fóton/métodos , Envelhecimento , Doenças em Gêmeos , Vértebras Lombares/diagnóstico por imagem , Fraturas por Osteoporose/diagnóstico por imagem , Sistema de Registros , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Pessoa de Meia-Idade , Fraturas por Osteoporose/epidemiologia , Reino Unido/epidemiologia , Adulto Jovem
5.
Eur Spine J ; 22(7): 1674-82, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23455953

RESUMO

PURPOSE: To establish the sensitivity and specificity of cross-sectional scintigraphy [single photon emission computed tomography (SPECT)] combined with computed X-ray tomography (CT) in the detection of sacroiliac joint (SIJ) mechanical dysfunction and evaluate reproducibility of reporting. METHODS: Patients with pelvic girdle pain either on the basis of peri-partum SIJ dysfunction or trauma were included. These patients were imaged with bone scintigraphy with hybrid imaging with SPECT/CT. RESULTS: The study group comprised 100 patients (72 females, 28 males). Trauma accounted for 52% and the remainder were patients with peri-partum pain. Average age was 43 years and average length of history was >2 years. The major finding was increased uptake in the upper SIJ and posterior soft-tissues/ligaments. Hybrid imaging had a sensitivity of 95% and specificity of 99%. Positive predictive value was 99% and negative predictive value 94%. Power of the test was 1.0. Reproducibility of the test was good with kappa values of 0.85. CONCLUSION: Hybrid imaging with SPECT/CT reproducibly demonstrates metabolic alterations around the SIJ in patients with SIJ dysfunction, which we have termed SIJ incompetence. The condition is more common than previously recognised and frequently occurs after trauma, which has not been reported previously.


Assuntos
Dor da Cintura Pélvica/diagnóstico , Dor da Cintura Pélvica/metabolismo , Articulação Sacroilíaca/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Sensibilidade e Especificidade , Adulto Jovem
6.
Eur J Nucl Med Mol Imaging ; 39(2): 326-36, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22057627

RESUMO

PURPOSE: Visual changes on radionuclide bone scans have been reported with teriparatide treatment. To assess this, serial studies were evaluated and quantified in ten postmenopausal women with osteoporosis treated with teriparatide (20 µg/day subcutaneous) who had (99m)Tc-methylene diphosphonate (MDP) bone scans (baseline, 3 and 18 months, then after 6 months off therapy). METHODS: Women were injected with 600 MBq (99m)Tc-MDP, and diagnostic bone scan images were assessed at 3.5 h. Additional whole-body scans (10 min, 1, 2, 3 and 4 h) were analysed for (99m)Tc-MDP skeletal plasma clearance (K(bone)). Regional K(bone) differences were obtained for the whole skeleton and six regions (calvarium, mandible, spine, pelvis, upper and lower extremities). Bone turnover markers (BTM) were also measured. RESULTS: Most subjects showed visual changes on 3- and 18-month bone scan images that disappeared after 6 months off therapy. Enhanced uptake was seen predominantly in the calvarium and lower extremities. Whole skeleton K(bone) displayed a median increase of 22% (3 months, p = 0.004) and 34% (18 months, p = 0.002) decreasing to 0.7% (6 months off therapy). Calvarium K(bone) changes were three times larger than other sites. After 6 months off therapy, all K(bone) and BTM values returned towards baseline. CONCLUSION: The increased (99m)Tc-MDP skeletal uptake with teriparatide indicated increased bone formation which was supported by BTM increases. After 6 months off therapy, metabolic activity diminished towards baseline. The modulation of (99m)Tc-MDP skeletal uptake during treatment was the result of teriparatide's metabolic activity. These findings may aid the radiological evaluation of similar teriparatide patients having radionuclide bone scans.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Osteoporose/tratamento farmacológico , Teriparatida/farmacologia , Idoso , Densidade Óssea , Remodelação Óssea , Feminino , Humanos , Pessoa de Meia-Idade , Osteoporose/diagnóstico , Osteoporose Pós-Menopausa/diagnóstico , Osteoporose Pós-Menopausa/tratamento farmacológico , Cintilografia , Medronato de Tecnécio Tc 99m/uso terapêutico , Fatores de Tempo , Imagem Corporal Total/métodos
7.
Eur J Nucl Med Mol Imaging ; 39(2): 337-43, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22065012

RESUMO

PURPOSE: We evaluate a new quantitative method of acquiring and analysing (18)F positron emission tomography (PET) studies that enables regional bone plasma clearance (K ( i )) to be estimated from static scans acquired at multiple sites in the skeleton following a single injection of tracer. METHODS: Dynamic lumbar spine (18)F PET data from two clinical trials were used to simulate a series of static scans acquired 30-60 min after injection. Venous blood samples were taken at 30, 40, 50 and 60 min and K ( i ) evaluated by Patlak analysis and the static scan method. The data were used to evaluate the precision errors of the Patlak and static scan methods expressed as the percentage coefficient of variation (%CV) and compare their response to 6 months of treatment with the bone anabolic agent teriparatide. RESULTS: Static scan K ( i ) measurements 30-60 min after injection were highly correlated with the Patlak results (r > 0.99). The %CV for the static scan method was 17.5% 30 min after injection, decreasing to 14.5% at 60 min, compared with 13.0% for Patlak analysis. Response to teriparatide treatment was +25.2% for the static scan method compared with +24.3% for Patlak analysis. The mean ratio (SD) of the static scan and Patlak K ( i ) results was 1.006 (0.015) at 30 min after injection decreasing to 0.965 (0.015) at 60 min. CONCLUSION: (18)F-Fluoride bone plasma clearance can be estimated from a static scan and venous blood samples acquired 30-60 min after injection. The method enables K ( i ) to be estimated at multiple skeletal sites with a single injection of tracer.


Assuntos
Osso e Ossos/metabolismo , Fluordesoxiglucose F18/farmacologia , Tomografia por Emissão de Pósitrons/métodos , Idoso , Osso e Ossos/efeitos dos fármacos , Feminino , Radioisótopos de Flúor/farmacologia , Humanos , Processamento de Imagem Assistida por Computador , Cinética , Pessoa de Meia-Idade , Modelos Estatísticos , Osteoporose Pós-Menopausa/tratamento farmacológico , Teriparatida/farmacologia , Fatores de Tempo , Imagem Corporal Total
8.
J Clin Densitom ; 15(3): 315-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22402120

RESUMO

The precision errors of dual-energy X-ray absorptiometry (DXA) measurements are important for monitoring osteoporosis. This study investigated the effect of body mass index (BMI) on precision errors for lumbar spine (LS), femoral neck (NOF), total hip (TH), and total body (TB) bone mineral density using the GE Lunar Prodigy. One hundred two women with BMIs ranging from 18.5 to 45.9 kg/m(2) were recruited. Participants had duplicate DXA scans of the LS, left hip, and TB with repositioning between scans. Participants were divided into 3 groups based on their BMI and the percentage coefficient of variation (%CV) calculated for each group. The %CVs for the normal (<25 kg/m(2)) (n=48), overweight (25-30 kg/m(2)) (n=26), and obese (>30 kg/m(2)) (n=28) BMI groups, respectively, were LS BMD: 0.99%, 1.30%, and 1.68%; NOF BMD: 1.32%, 1.37%, and 2.00%; TH BMD: 0.85%, 0.88%, and 1.06%; TB BMD: 0.66%, 0.73%, and 0.91%. Statistically significant differences in precision error between the normal and obese groups were found for LS (p=0.0006), NOF (p=0.005), and TB BMD (p=0.025). These results suggest that serial measurements in obese subjects should be treated with caution because the least significant change may be larger than anticipated.


Assuntos
Absorciometria de Fóton , Obesidade/epidemiologia , Osteoporose/diagnóstico , Osteoporose/epidemiologia , Absorciometria de Fóton/normas , Adolescente , Adulto , Idoso , Índice de Massa Corporal , Comorbidade , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
9.
J Clin Densitom ; 14(3): 263-71, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21600822

RESUMO

Studies of bone remodeling using bone biopsy and biochemical markers of bone turnover play an important role in research studies to investigate the effect of new osteoporosis treatments on bone quality. Quantitative radionuclide imaging using either positron emission tomography with fluorine-18 sodium fluoride or gamma camera studies with technetium-99m methylene diphosphonate provides a novel tool for studying bone metabolism that complements conventional methods, such as bone turnover markers (BTMs). Unlike BTMs, which measure the integrated response to treatment across the whole skeleton, radionuclide imaging can distinguish the changes occurring at sites of particular clinical interest, such as the spine or proximal femur. Radionuclide imaging can be used to measure either bone uptake or (if done in conjunction with blood sampling) bone plasma clearance. Although the latter is more complicated to perform, unlike bone uptake, it provides a measurement that is specific to the bone metabolic activity at the measurement site. Treatment with risedronate was found to cause a decrease in bone plasma clearance, whereas treatment with the bone anabolic agent teriparatide caused an increase. Studies of teriparatide are of particular interest because the treatment has different effects at different sites in the skeleton, with a substantially greater response in the flat bone of the skull and cortical bone in the femur compared with the lumbar spine. Future studies should include investigations of osteonecrosis of the jaw and atypical fractures of the femur to examine the associated regional changes in bone metabolism and to throw light on the underlying pathologies.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Osteoporose/tratamento farmacológico , Conservadores da Densidade Óssea/uso terapêutico , Osso e Ossos/metabolismo , Ácido Etidrônico/análogos & derivados , Ácido Etidrônico/uso terapêutico , Radioisótopos de Flúor , Câmaras gama , Humanos , Osteoporose/metabolismo , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Ácido Risedrônico , Medronato de Tecnécio Tc 99m , Teriparatida/uso terapêutico
10.
Nucl Med Commun ; 42(6): 699-706, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33625180

RESUMO

[18F]NaF PET imaging is a useful tool for measuring regional bone metabolism. However, due to tracer in urine, [18F]NaF PET images of the hip reconstructed using filtered back projection (FBP) frequently show streaking artifacts in slices through the bladder leading to noisy time-activity curves unsuitable for quantification. This study compares differences between quantitative outcomes at the hip derived from images reconstructed using the FBP and ordered-subset expectation maximization (OSEM) methods. Dynamic [18F]NaF PET data at the hip for four postmenopausal women were reconstructed using FBP and nine variations of the OSEM algorithm (all combinations of 1, 5, 15 iterations and 10, 15, 21 subsets). Seven volumes of interest were placed in the hip. Bone metabolism was measured using standardized uptake values, Patlak analysis (Ki-PAT) and Hawkins model Ki-4k. Percentage differences between the standardized uptake values and Ki values from FBP and OSEM images were assessed. OSEM images appeared visually smoother and without the streaking artifacts seen with FBP. However, due to loss of counts, they failed to recover the quantitative values in VOIs close to the bladder, including the femoral head and femoral neck. This was consistent for all quantification methods. Volumes of interest farther from the bladder or larger and receiving greater counts showed good convergence with 5 iterations and 21 subsets. For VOIs close to the bladder, including the femoral neck and femoral head, 15 iterations and 10, 15 or 21 subsets were not enough to obtain OSEM images suitable for measuring bone metabolism and showed no improvement compared to FBP.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Algoritmos , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas
11.
Eur J Nucl Med Mol Imaging ; 37(4): 706-13, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20016889

RESUMO

PURPOSE: The purpose of this study was to investigate the additional value of single photon emission computed tomography/computed tomography (SPECT/CT) over whole-body planar bone scintigraphy and SPECT in prostate cancer patients in terms of diagnostic confidence, inter-reviewer agreement and the possible impact on the clinical management. METHODS: This was a retrospective review of 40 consecutive prostate cancer patients (mean age 71 years) who underwent (99m)Tc-methylene diphosphonate (MDP) whole-body planar bone scintigraphy, SPECT and SPECT/CT between April 2006 and April 2008. The images were evaluated by two independent reviewers; inter-reviewer agreement was evaluated using a weighted kappa score. Each focus of abnormal increased tracer uptake was recorded using a 4-point diagnostic confidence scale. Institutional Review Board approval was obtained. RESULTS: Fifty lesions on planar bone scintigraphy in the 40 patients were evaluated. On reporting the planar study and SPECT scans, reviewers rated 61% of lesions as equivocal. On reporting the SPECT/CT scans only 8% of lesions were rated as equivocal, 24% were rated as malignant and 68% as benign. Weighted kappa scores for inter-reviewer agreement were 0.43 for bone scintigraphy, 0.56 for SPECT and 0.87 for SPECT/CT. All were significant at p < 0.0001. Follow-up imaging confirmed the SPECT/CT diagnoses in 14 patients. CONCLUSION: The addition of SPECT/CT resulted in a significant reduction of equivocal reports; a definitive diagnosis was given in the majority of the patients due to the improved diagnostic confidence compared to planar or SPECT imaging alone in prostate cancer patients with suspected bone metastases.


Assuntos
Adenocarcinoma/secundário , Neoplasias Ósseas/secundário , Neoplasias da Próstata/patologia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada Espiral , Adenocarcinoma/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/diagnóstico por imagem , Diagnóstico Diferencial , Fraturas por Compressão/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Planejamento de Assistência ao Paciente , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/secundário , Imagem Corporal Total
12.
J Clin Densitom ; 13(3): 292-300, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20554233

RESUMO

Because osteoporosis is common and usually managed in primary care, there is a requirement for cheap and convenient methods of measuring bone mineral density (BMD). AccuDEXA (Lone Oak Medical Technologies, Doylestown, PA) is a tabletop dual-energy X-ray absorptiometry (DXA) device that performs BMD measurements of the hand in the middle phalanges of the third finger. The aims of this study were to (1) evaluate the use of AccuDEXA in UK women; (2) investigate the concordance between AccuDEXA T-scores and DXA T-scores for central (spine and hip) sites; (3) investigate the comparative response of AccuDEXA measurements to clinical risk factors for osteoporosis. Measurements of phalangeal and central BMD were performed in 620 women referred by their family doctors for bone densitometry (group 1) and 159 healthy female volunteers (group 2). For 65 women in group 2, aged 39 yr or younger, the mean Z-scores for AccuDEXA and the central sites calculated from US reference ranges were consistent with the expected value of 0, whereas for the 62 group 2 women, aged 50 yr or older, the mean Z-scores for AccuDEXA and the central sites were in the range 0.4-0.7 and were statistically significantly different from 0. In both group 1 and group 2, the AccuDEXA T-scores in older and younger women were systematically higher than those in the central sites by up to 1 unit. Of the 157 women aged 50 yr or older, with osteoporosis, based on their central DXA results, only 34 (22%) had an AccuDEXA T-score less than or equal to -2.5, whereas 76 (48%) had osteopenia and 47 (30%) were normal based on their AccuDEXA T-scores. When assessed by the effect of clinical risk factors on Z-scores, both AccuDEXA and central BMD were affected to a similar extent. We conclude that the conventional World Health Organisation T-score criteria for the diagnosis of osteoporosis should not be applied to AccuDEXA measurements in UK women. Clinical risk factors for low BMD were found to affect AccuDEXA measurements to a similar extent as central BMD measurements. AccuDEXA measurements could, therefore, provide an alternative method for identifying individuals with low bone mass, provided care is taken in interpreting T-scores, perhaps, through the use of device-specific thresholds.


Assuntos
Absorciometria de Fóton/métodos , Dedos/fisiologia , Adulto , Idoso , Densidade Óssea , Feminino , Quadril/fisiologia , Humanos , Pessoa de Meia-Idade , Análise de Regressão , Fatores de Risco , Coluna Vertebral/fisiologia
13.
JRSM Cardiovasc Dis ; 8: 2048004019848870, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31105936

RESUMO

INTRODUCTION: Aortic calcification as detected by computed tomography is associated with arterial stiffening and is an important predictor of cardiovascular morbidity and mortality. Uptake of 18F-sodium fluoride (18F-NaF) in the aortic wall reflects metabolically active areas of calcification. The aim of this study was to determine if 18F-NaF uptake in the aorta is associated with calcification and progression of calcification as detected by computed tomography. METHODS: Twenty-one postmenopausal women (mean age 62 ± 6 years) underwent assessment of aortic 18F-NaF uptake using positron emission tomography/computer tomography at baseline and a repeat computed tomography scan after a mean follow-up of 3.8 ± 1.3 years. Tracer uptake was quantified by calculating the target-to-background (TBR) ratios at baseline and follow-up. Calcification was assessed at baseline and follow-up using computed tomography. RESULTS: Over the follow-up period, aortic calcium volume increased from 0.46 ± 0.62 to 0.71 ± 0.93 cm3 (P < 0.05). However, the change in calcium volume did not correlate with baseline TBR either unadjusted (r = 0.00, P = 1.00) or adjusted for age and baseline calcium volume (beta coefficient = -0.18, P = 0.42). TBR at baseline did not differ between participants with (n = 16) compared to those without (n = 5) progression in calcium volume (2.43 ± 0.46 vs. 2.31 ± 0.38, P = 0.58). In aortic segments identified to have the highest tracer uptake at baseline, calcium volume did not significantly change over the follow-up period (P = 0.41). CONCLUSION: In a cohort of postmenopausal women, 18F-NaF uptake as measured by TBR in the lumbar aorta did not predict progression of aortic calcification as detected by computed tomography over a four-year follow-up.

14.
J Nucl Med ; 49(3): 375-82, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18287266

RESUMO

UNLABELLED: Quantitative studies of bone using (99m)Tc-methylene diphosphonate ((99m)Tc-MDP) have a potentially valuable role in investigating the treatment of patients with metabolic bone disease. In this study we compared 3 different methods of measuring whole-skeleton (99m)Tc-MDP plasma clearance (K(bone)) in 12 osteoporotic postmenopausal women (mean age, 67.3 y) before participation in a clinical trial of an osteoporosis therapy. The aim was to compare the consistency and accuracy of the 3 methods before their use in evaluating the subjects' response to treatment. METHODS: Subjects were injected with 600 MBq (99m)Tc-MDP and 3 MBq (51)Cr-ethylenediaminetetraacetic acid ((51)Cr-EDTA) and whole-body bone scan images were acquired at 10 min, 1, 2, 3, and 4 h. Two-minute static images of the thighs were acquired immediately after the 1- to 4-h whole-body scans. Six blood samples were taken between 5 min and 4 h, and free (99m)Tc-MDP was measured using ultrafiltration. The glomerular filtration rate (GFR) was estimated from the (51)Cr-EDTA plasma curve. The methods used to evaluate K(bone) were (a) the area-under-the-curve (AUC) method, in which the GFR measurement was subtracted from the total (bone plus renal) clearance (K(total)) measured from the free (99m)Tc-MDP plasma curve; (b) the modified Brenner method, in which (99m)Tc-MDP renal clearance estimated from the whole-body counts was subtracted from the total clearance measured from the rate of elimination of tracer from soft tissue; and (c) the Patlak plot method, which was also used to derive regional values of K(bone) for the skull, spine, pelvis, arms, and legs. RESULTS: There was good agreement between the 3 methods of measuring K(bone). (mean K(bone) +/- SD: AUC method, 30.3 +/- 6.4 mL x min(-1); Brenner method, 31.1 +/- 5.8 mL x min(-1); Patlak method, 35.7 +/- 5.8 mL x min(-1)). The correlation coefficients between the methods varied from r = 0.767 (P = 0.004) to r = 0.805 (P = 0.002). Regional measurements of (99m)Tc-MDP clearance gave the following percentages of the whole-skeleton clearance: skull, 13.3%; spine, 16.6%; pelvis, 17.2%; arms, 11.1%; legs, 23.7%. CONCLUSION: The 3 methods gave consistent and accurate measurements of K(bone). The Patlak method can be used to study regional as well as total-skeleton values of K(bone).


Assuntos
Remodelação Óssea , Interpretação de Imagem Assistida por Computador/métodos , Osteoporose Pós-Menopausa/sangue , Osteoporose Pós-Menopausa/diagnóstico por imagem , Medronato de Tecnécio Tc 99m/farmacocinética , Idoso , Feminino , Humanos , Taxa de Depuração Metabólica , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
J Nucl Med ; 49(5): 700-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18413385

RESUMO

UNLABELLED: (18)F-Fluoride PET allows noninvasive evaluation of regional bone metabolism and has the potential to become a useful tool for assessing patients with metabolic bone disease and evaluating novel drugs being developed for these diseases. The main PET parameter of interest, termed K(i), reflects regional bone metabolism. The aim of this study was to compare the long-term precision of (18)F-fluoride PET with that of biochemical markers of bone turnover assessed over 6 mo. METHODS: Sixteen postmenopausal women with osteoporosis or significant osteopenia and a mean age of 64 y underwent (18)F-fluoride PET of the lumbar spine and measurements of biochemical markers of bone formation (bone-specific alkaline phosphatase and osteocalcin) and bone resorption (urinary deoxypyridinoline) at baseline and 6 mo later. Four different methods for analyzing the (18)F-fluoride PET data were compared: a 4k 3-compartmental model using nonlinear regression analysis (K(i-4k)), a 3k 3-compartmental model using nonlinear regression analysis (K(i-3k)), Patlak analysis (K(i-PAT)), and standardized uptake values. RESULTS: With the exception of a small but significant decrease in K(i-3k) at 6 mo, there were no significant differences between the baseline and 6-mo values for the PET parameters or biochemical markers. The long-term precision, expressed as the coefficient of variation (with 95% confidence interval in parentheses), was 12.2% (9%-19%), 13.8% (10%-22%), 14.4% (11%-22%), and 26.6% (19%-40%) for K(i-3k), K(i-PAT), mean standardized uptake value, and K(i-4k), respectively. For comparison, the precision of the biochemical markers was 10% (7%-15%), 18% (13%-27%), and 14% (10%-21%) for bone-specific alkaline phosphatase, osteocalcin, and urinary deoxypyridinoline, respectively. Intraclass correlation between the baseline and 6-mo values ranged from 0.44 for K(i-4k) to 0.85 for K(i-3k). No significant correlation was found between the repeated mean standardized uptake value measurements. CONCLUSION: The precision and intraclass correlation observed for K(i-3k) and K(i-PAT) was equivalent to that observed for biochemical markers. This study provided initial data on the long-term precision of (18)F-fluoride PET measured at the lumbar spine, which will aid in the accurate interpretation of changes in regional bone metabolism in response to treatment.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osso e Ossos/metabolismo , Radioisótopos de Flúor , Tomografia por Emissão de Pósitrons/métodos , Idoso , Biomarcadores , Feminino , Humanos , Cinética , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/metabolismo , Pessoa de Meia-Idade , Pós-Menopausa , Sensibilidade e Especificidade , Fatores de Tempo
18.
Quant Imaging Med Surg ; 8(1): 47-59, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29541623

RESUMO

Dynamic positron emission tomography (PET) imaging with fluorine-18 labelled sodium fluoride ([18F]NaF) allows the quantitative assessment of regional bone formation by measuring the plasma clearance of fluoride to bone at any site in the skeleton. Today, hybrid PET and computed tomography (CT) dual-modality systems (PET/CT) are widely available, and [18F]NaF PET/CT offers a convenient non-invasive method of studying bone formation at the important osteoporotic fracture sites at the hip and spine, as well as sites of pure cortical or trabecular bone. The technique complements conventional measurements of bone turnover using biochemical markers or bone biopsy as a tool to investigate new therapies for osteoporosis, and has a potential role as an early biomarker of treatment efficacy in clinical trials. This article reviews methods of acquiring and analyzing dynamic [18F]NaF PET/CT scan data, and outlines a simplified approach combining venous blood sampling with a series of short (3- to 5-minute) static PET/CT scans acquired at different bed positions to estimate [18F]NaF plasma clearance at multiple sites in the skeleton with just a single injection of tracer.

19.
Crit Rev Oncol Hematol ; 64(3): 198-207, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17855108

RESUMO

Reports of osteonecrosis of the jaw (ONJ) in patients receiving long-term bisphosphonate therapy have appeared in the literature since 2003. This condition involves avascular necrotic bone in the area of maxilla or mandibula and there may be a secondary infection. Most cases of ONJ have been reported in cancer patients receiving the intravenous aminobisphosphonates zoledronic acid and pamidronate monthly or q 3 week; of note these are also the two most commonly used agents of this class. Risk factors for ONJ include a history of trauma, dental surgery or dental infection and intravenous bisphosphonate administration; in addition, the extent and duration of exposure to bisphosphonates also seem to correlate with the risk. Although a direct causal relationship with bisphosphonates cannot be assumed, these agents may possibly contribute to the development of ONJ by suppression of bone remodeling in the jaw which leads to increased rates of bone mineralisation and accumulation of microfractures. Clodronate, a non-aminobisphosphonate, appears to have a different mechanism of suppressing bone remodeling compared with aminobisphosphonates, and this may explain why few cases of ONJ have been reported with clodronate despite extensive use over the past 20 years; however, the potential of clodronate to reduce the risk of ONJ while providing equivalent clinical benefit to the aminobisphosphonates needs to be substantiated in controlled clinical trials. Use of bisphosphonate therapy should be carefully planned in patients with metastatic bone disease who have risk factors for ONJ, and appropriate preventive measures taken to avoid the development of this condition.


Assuntos
Difosfonatos/efeitos adversos , Difosfonatos/química , Doenças Maxilomandibulares/induzido quimicamente , Doenças Maxilomandibulares/terapia , Osteonecrose/induzido quimicamente , Osteonecrose/terapia , Humanos , Incidência , Doenças Maxilomandibulares/epidemiologia , Doenças Maxilomandibulares/prevenção & controle , Modelos Biológicos , Osteonecrose/epidemiologia , Osteonecrose/prevenção & controle , Fatores de Risco , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS