Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Phys Med ; 32(12): 1724-1730, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27856119

RESUMO

Interventional radiology and hemodynamic procedures have rapidly grown in number in the past decade, increasing the importance of personnel dosimetry not only for patients but also for medical staff. The optimization of the absorbed dose during operations is one of the goals that fostered the development of real-time dosimetric systems. Indeed, introducing proper procedure optimization, like correlating dose rate measurements with medical staff position inside the operating room, the absorbed dose could be reduced. Real-time dose measurements would greatly facilitate this task through real-time monitoring and automatic data recording. Besides real-time dose monitoring could allow automatic data recording. In this work, we will describe the calibration and validation of a wireless real-time prototype dosimeter based on a new sensor device (CMOS imager). The validation measurement campaign in clinical conditions has demonstrated the prototype capability of measuring dose-rates with a frequency in the range of few Hz, and an uncertainty smaller than 10%.


Assuntos
Radiologia Intervencionista , Radiometria/métodos , Radiometria/instrumentação , Fatores de Tempo , Tecnologia sem Fio
2.
Ann Ist Super Sanita ; 35(4): 577-81, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10721228

RESUMO

The sedimentable mineral organic detritus (SMOD) drawn by rivers can be considered an important matrix for the monitoring of contaminants in aquatic environments. In Italy the collection and radioactivity analysis of SMOD has been introduced and standardised in the 80s. However hydrological parameters, like the flow and the amount of suspended matter close to the sampling points, must be considered to improve the methodology. This technique has been applied by the authors since 1992 to monitor the concentration of both 137Cs (following the Chernobyl accident) and 131I (because of possible waste discharge from Perugia University Hospital) along the Umbrian course of the Tiber River. In this paper the results of 137Cs water concentration are presented and discussed in the light of our interpretative working hypothesis based on hydrological parameters. This work allowed us to reduce the number of sampling points without loss of radioecological information.


Assuntos
Ecologia , Sedimentos Geológicos/análise , Minerais/análise , Poluentes Radioativos/análise , Monitoramento Ambiental/métodos , Água Doce , Itália , Espectrometria gama/métodos
3.
Radiat Prot Dosimetry ; 110(1-4): 627-30, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353720

RESUMO

The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with (10)B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 10(9) to 10(14) nth cm(-2). The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those using only alanine. Moreover, a negligible correction for the gamma contribution, measured with TL detectors, almost insensitive to thermal neutrons, was necessary. Therefore, a simultaneous analysis of our TL and ESR detectors allows discrimination between thermal neutron and gamma doses, as required in BNCT.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Raios gama/uso terapêutico , Nêutrons/uso terapêutico , Proteção Radiológica/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/métodos , Carga Corporal (Radioterapia) , Boro/efeitos da radiação , Terapia por Captura de Nêutron de Boro/instrumentação , Humanos , Isótopos/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Integração de Sistemas , Dosimetria Termoluminescente/instrumentação
4.
Pharmacol Res ; 32(1-2): 69-74, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8668650

RESUMO

The accident to the nuclear power plant of Chernobyl (in April 1986) caused a radioactive contamination in large areas of the majority of European countries. During the first transient time the fall-out phenomenon was the most important method of contamination, particularly from 131I whose relative isotopic abundance with respect to other released radionuclides was very high. Thereafter, 137Cs, owing to its long half-time and its large presence in environmental matrixes and so in the food chain, became the element on which the attention was to be focused. Plant drugs and their derivatives are, at present, of very large alimentary consumption among people. This can cause some problems to human health, so the authors have studied (from 1986 to 1994) the activity of 137Cs in a large number of drugs (about 5000) and in some industrial and home-made officinal products. Some suggestions on the Cs+,K+ ions competition in soil can also be derived.


Assuntos
Radioisótopos de Césio/análise , Plantas Medicinais/química , Centrais Elétricas , Cinza Radioativa/análise , Liberação Nociva de Radioativos , Contaminação de Alimentos , Troca Iônica , Radioisótopos de Potássio/análise , Poluentes Radioativos do Solo/análise , Ucrânia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA