Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Heart J Suppl ; 25(Suppl C): C49-C57, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125321

RESUMO

Ischaemic heart disease (IHD) is one of the world's leading causes of morbidity and mortality. Likewise, the diagnosis and risk stratification of patients with coronary artery disease (CAD) have always been based on the detection of the presence and extent of ischaemia by physical or pharmacological stress tests with or without the aid of imaging methods (e.g. exercise stress, test, stress echocardiography, single-photon emission computed tomography, or stress cardiac magnetic resonance). These methods show high performance to assess obstructive CAD, whilst they do not show accurate power to detect non-obstructive CAD. The introduction into clinical practice of coronary computed tomography angiography, the only non-invasive method capable of analyzing the coronary anatomy, allowed to add a crucial piece in the puzzle of the assessment of patients with suspected or chronic IHD. The current review evaluates the technical aspects and clinical experience of coronary computed tomography in the evaluation of atherosclerotic burden with a special focus about the new emerging application such as functional relevance of CAD with fractional flow reserve computed tomography (CT)-derived (FFRct), stress CT perfusion, and imaging inflammatory makers discussing the strength and weakness of each approach.

2.
Eur J Nucl Med Mol Imaging ; 49(9): 3119-3128, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35194673

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of a deep learning (DL) algorithm predicting hemodynamically significant coronary artery disease (CAD) by using a rest dataset of myocardial computed tomography perfusion (CTP) as compared to invasive evaluation. METHODS: One hundred and twelve consecutive symptomatic patients scheduled for clinically indicated invasive coronary angiography (ICA) underwent CCTA plus static stress CTP and ICA with invasive fractional flow reserve (FFR) for stenoses ranging between 30 and 80%. Subsequently, a DL algorithm for the prediction of significant CAD by using the rest dataset (CTP-DLrest) and stress dataset (CTP-DLstress) was developed. The diagnostic accuracy for identification of significant CAD using CCTA, CCTA + CTP stress, CCTA + CTP-DLrest, and CCTA + CTP-DLstress was measured and compared. The time of analysis for CTP stress, CTP-DLrest, and CTP-DLStress was recorded. RESULTS: Patient-specific sensitivity, specificity, NPV, PPV, accuracy, and area under the curve (AUC) of CCTA alone and CCTA + CTPStress were 100%, 33%, 100%, 54%, 63%, 67% and 86%, 89%, 89%, 86%, 88%, 87%, respectively. Patient-specific sensitivity, specificity, NPV, PPV, accuracy, and AUC of CCTA + DLrest and CCTA + DLstress were 100%, 72%, 100%, 74%, 84%, 96% and 93%, 83%, 94%, 81%, 88%, 98%, respectively. All CCTA + CTP stress, CCTA + CTP-DLRest, and CCTA + CTP-DLStress significantly improved detection of hemodynamically significant CAD compared to CCTA alone (p < 0.01). Time of CTP-DL was significantly lower as compared to human analysis (39.2 ± 3.2 vs. 379.6 ± 68.0 s, p < 0.001). CONCLUSION: Evaluation of myocardial ischemia using a DL approach on rest CTP datasets is feasible and accurate. This approach may be a useful gatekeeper prior to CTP stress..


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Aprendizado Profundo , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Valor Preditivo dos Testes
3.
Eur Radiol ; 32(9): 6017-6027, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35364711

RESUMO

OBJECTIVES: Computed tomography (CT) provides excellent anatomy assessment of the aortic annulus (AoA) and is utilized for pre-procedural planning of transcatheter aortic valve implantation (TAVI). We sought to investigate if geometrical characteristics of the AoA determined by CT may represent predictors of structural valve degeneration (SVD) in patients undergoing TAVI with balloon-expandable valves. METHODS: This is a retrospective study on 124 consecutive patients (mean age: 79 ± 7 years; female: 61%) undergoing balloon-expandable TAVI prospectively enrolled in a registry. AoA maximum diameter (Dmax), minimum diameter (Dmin), and area were assessed using pre-procedural CT. SVD was identified during follow-up with transthoracic echocardiography documenting structural prosthetic valve abnormalities with or without hemodynamic changes. RESULTS: The mean follow-up was 5.9 ± 1.7 years. SVD was found in 48 out of 124 patients (38%). AoA Dmax, Dmin, and area were significantly smaller in patients with SVD compared to patients without SVD (25.6 ± 2.2 mm vs. 27.1 ± 2.8 mm, p = 0.012; 20.5 ± 2.1 mm vs. 21.8 ± 2.1 mm, p = 0.001 and 419 ± 77 mm2 vs. 467 ± 88 mm2, p = 0.002, respectively). At univariable analysis, female sex, BSA, 23-mm prosthetic valve size, Dmax < 27.1 mm, and a Dmin < 19.9 mm were associated with SVD, whereas at multivariable analysis, only Dmin < 19.9 mm (OR = 2.873, 95% CI: 1.191-6.929, p = 0.019) and female sex (OR = 2.659, 95% CI: 1.095-6.458, p = 0.031) were independent predictors of SVD. CONCLUSIONS: Female sex and AoA Dmin < 19.9 mm are associated with SVD in patients undergoing TAVI with balloon-expandable valves. When implanting large prostheses in order to avoid paraprosthetic regurgitation, caution should be observed due to the risk of excessive stretching of the AoA Dmin, which may play a role in SVD. KEY POINTS: • Long-term durability is a concern for transcatheter aortic valve bioprosthesis. • CT provides an excellent assessment of the aortic annulus's geometrical characteristics for prosthesis sizing before transcatheter aortic valve implantation (TAVI). • Female sex and a small minimum aortic annulus diameter measured with CT are independent predictors of structural valve degeneration in patients undergoing TAVI with balloon-expandable valves.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
4.
Nutr Metab Cardiovasc Dis ; 32(3): 586-595, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35109998

RESUMO

BACKGROUND AND AIMS: The aim of the present study is to evaluate whether advanced coronary atherosclerosis analysis by CCTA may improve prognostic stratification among diabetic patients at high cardiovascular risk (CV risk). METHODS AND RESULTS: The study population consisted of 265 consecutive diabetic patients at high CV risk who underwent CCTA for suspected CAD between January 2011 and December 2016. For every patients both traditional and advanced, qualitative and quantitative coronary plaque analysis were performed. The occurrence of cardiac death, ACS, and non-urgent revascularization were recorded at follow-up. Among the 265 patients enrolled, 21 were lost to follow-up, whereas 244 (92%) had a complete follow-up (mean 45 ± 22 months) and were classified at high (n = 67) or very high cardiovascular risk (n = 177), according to ESC Guidelines. A total of 63 events were recorded (3 Cardiac Death, 3 NSTEMI, 8 unstable angina, 36 late non-urgent revascularization and 13 non-cardiac death) in 57 different patients. Elevated fibro-fatty plaque volume was the only predictor of events over age, gender and traditional risk factor when ACS and MACE were considered as end-points [HR (95% CI) 6.01 (1.65-21.87), p = 0.006 and 3.46 (2.00-5.97); p < 0.001]. CONCLUSION: The present study confirms the prognostic role of advance coronary atherosclerosis evaluation beyond risk factors and stenosis severity, even in diabetics. Despite the very high cardiovascular risk of study population, a not negligible portion (23%) of patients exhibited totally normal coronaries.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Placa Aterosclerótica , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Seguimentos , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/terapia , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco
5.
Eur Radiol ; 28(4): 1383-1392, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29164383

RESUMO

OBJECTIVES: To evaluate image quality, coronary evaluability and radiation exposure of coronary CT angiography (CCTA) performed with whole-heart coverage cardiac-CT in patients with atrial fibrillation (AF). MATERIALS AND METHODS: We prospectively enrolled 164 patients with AF who underwent a clinically indicated CCTA with a 16-cm z-axis coverage scanner. In all patients CCTA was performed using prospective ECG-triggering with targeted RR interval. We evaluated image quality, coronary evaluability and effective dose (ED). Patients were divided in two subgroups based on heart rate (HR) during imaging. Group 1: 64 patients with low HR (<75 bpm), group 2: 100 patients with high HR (≥75 bpm). Written informed consent was obtained from all patients and the institutional ethics committee approved the study protocol. RESULTS: In a segment-based analysis, coronary evaluability was 98.4 % (2,577/2,620 segments) in the whole population, without significant differences between groups (1,013/1,024 (98.9 %) and 1,565/1,596 (98.1 %), for groups 1 and 2, respectively, p=0.15). Mean ED was similar in both groups (3.8±1.9 mSv and 3.9±2.1 mSv in groups 1 and 2, respectively, p=0.75) CONCLUSIONS: The whole-heart-coverage scanner could evaluate coronary arteries with high image quality and without increase in radiation exposure in AF patients, even in the high HR group. KEY POINTS: • Last-generation CT scanner improves coronary artery assessment in AF patients. • The new CT scanner enables low radiation exposure in AF patients. • Diagnostic ICA maybe avoided in AF patients with suspected CAD. • Whole-heart coverage CT scanner enables low radiation exposure in AF patients.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Idoso , Artefatos , Fibrilação Atrial/fisiopatologia , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/instrumentação , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Masculino , Movimento (Física) , Estudos Prospectivos
6.
Radiology ; 284(3): 676-684, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28445682

RESUMO

Purpose To assess image quality, interpretability, diagnostic accuracy, and radiation exposure of a computed tomography (CT) scanner with 16-cm coverage and 230-µm spatial resolution at coronary artery evaluation in patients with atrial fibrillation (AF) by using invasive coronary angiography (ICA) as the reference method and to compare the results with those obtained in patients with sinus rhythm (SR). Materials and Methods Written informed consent and institutional ethics committee approval were obtained. Between March 2015 and February 2016, 166 consecutive patients were prospectively enrolled (83 with AF, 83 with SR). They underwent ICA and coronary CT angiography performed with a whole-heart CT scanner. Image quality, coronary segment interpretability, effective dose (ED), and diagnostic accuracy were assessed at CT angiography and were compared with those attained with ICA. Diagnostic performance of the groups was compared with the pairwise McNemar test. Results Mean heart rate during scanning was 83 beats per minute ± 21 (standard deviation) in the AF group and 63 beats per minute ± 14 in the SR group (P < .01). Coronary interpretability was 98.5% in the AF group and 98.4% in the SR group (P = .96). In a segment-based analysis, sensitivity and specificity in the detection of coronary stenosis of more than 50% compared with detection of ICA were 96.4% and 98.7%, respectively, in the chronic AF group (P = .98) and 95.6% and 98.1%, respectively, in the SR group (P = .32). In a patient-based analysis, sensitivity and specificity were 95.2% and 97.6%, respectively, in the chronic AF group (P = .95) and 97.8% and 94.7%, respectively, in the SR group (P = .93). Conclusion Whole-heart CT enables evaluation of coronary arteries with high image quality, low radiation exposure, and high diagnostic accuracy in patients with chronic AF, with a diagnostic performance similar to that in patients with SR. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Tomógrafos Computadorizados , Idoso , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade
7.
Eur Radiol ; 26(1): 147-56, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25953001

RESUMO

OBJECTIVES: The aim of this study was to evaluate the impact of a novel intra-cycle motion correction algorithm (MCA) on overall evaluability and diagnostic accuracy of cardiac computed tomography coronary angiography (CCT). METHODS: From a cohort of 900 consecutive patients referred for CCT for suspected coronary artery disease (CAD), we enrolled 160 (18 %) patients (mean age 65.3 ± 11.7 years, 101 male) with at least one coronary segment classified as non-evaluable for motion artefacts. The CCT data sets were evaluated using a standard reconstruction algorithm (SRA) and MCA and compared in terms of subjective image quality, evaluability and diagnostic accuracy. RESULTS: The mean heart rate during the examination was 68.3 ± 9.4 bpm. The MCA showed a higher Likert score (3.1 ± 0.9 vs. 2.5 ± 1.1, p < 0.001) and evaluability (94%vs.79 %, p < 0.001) than the SRA. In a 45-patient subgroup studied by clinically indicated invasive coronary angiography, specificity, positive predictive value and accuracy were higher in MCA vs. SRA in segment-based and vessel-based models, respectively (87%vs.73 %, 50%vs.34 %, 85%vs.73 %, p < 0.001 and 62%vs.28 %, 66%vs.51 % and 75%vs.57 %, p < 0.001). In a patient-based model, MCA showed higher accuracy vs. SCA (93%vs.76 %, p < 0.05). CONCLUSIONS: MCA can significantly improve subjective image quality, overall evaluability and diagnostic accuracy of CCT. KEY POINTS: Cardiac computed tomographic coronary angiography (CCT) allows non-invasive evaluation of coronary arteries. Intra-cycle motion correction algorithm (MCA) allows for compensation of coronary motion. An MCA improves image quality, CCT evaluability and diagnostic accuracy.


Assuntos
Algoritmos , Artefatos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes
8.
Radiology ; 271(3): 688-94, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24520943

RESUMO

PURPOSE: To compare the image quality, evaluability, diagnostic accuracy, and radiation exposure of high-spatial-resolution (HR, 0.23-mm) computed tomographic (CT) coronary angiography with standard spatial resolution (SR, 0.625-mm) 64-section imaging in patients at high risk for coronary artery disease (CAD) by using invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: Written informed consent was obtained from all patients, and the study protocol was approved by the institutional ethical committee. Patients at high risk for CAD (n = 184) who were scheduled for ICA were randomly assigned for study with SR (n = 91) or HR (n = 93) coronary CT angiography before they underwent ICA. To compare the two groups, the Student t test or Wilcoxon test were used to evaluate differences in continuous variables. The χ(2) test or Fisher exact test were used, as appropriate, for categorical data. The McNemar test was used to compare the diagnostic performance of coronary CT angiography versus that of ICA in each group. RESULTS: HR coronary CT angiography showed a higher image quality score (3.7 vs 3.4, P < .001) and evaluability (97% vs 92%, P < .002). In a segment-based analysis, HR coronary CT angiography showed a higher specificity, positive predictive value, and accuracy in comparison with SR coronary CT angiography (98%, 91%, and 99% vs 95%, 80%, and 95%, respectively; P < .001). Moreover, HR coronary CT angiography showed a better agreement with ICA for calcified plaques compared with SR coronary CT angiography and ICA (83% vs 53%, P < .001). In a patient-based analysis, HR coronary CT angiography showed higher specificity and accuracy compared with SR coronary CT angiography (91% and 98% vs 46% and 92%, respectively; P < .01). No differences in radiation exposure were found between the two groups. CONCLUSION: Improved evaluability and accuracy were seen with HR compared with SR coronary CT angiography of calcified coronary artery lesions, suggesting a potential use for this technology in patients at high risk for CAD.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Razão Sinal-Ruído
9.
Am Heart J ; 168(3): 332-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25173545

RESUMO

BACKGROUND: Multidetector computed tomography (MDCT) provides detailed assessment of valve annulus and iliofemoral vessels in transcatheter aortic valve replacement (TAVR) patients. However, data on diagnostic performance of MDCT coronary angiography (MDCT-CA) are scarce. The aim of the study is to assess diagnostic performance of MDCT for coronary artery evaluation before TAVR. METHODS: A total of 325 consecutive patients (234 without previous myocardial revascularization, 49 with previous coronary stenting, and 42 with previous coronary artery bypass graft [CABG]) underwent invasive coronary angiography and MDCT before TAVR. MDCT-CA was performed using the same data set dedicated to standard MDCT aortic annulus evaluation. Multidetector computed tomography-CA evaluability and diagnostic accuracy in comparison with invasive coronary angiography as criterion standard were assessed. RESULTS: The MDCT-CA evaluability of native coronaries was 95.6%. The leading cause of unevaluability was beam-hardening artifact due to coronary calcifications. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for detecting ≥50% stenosis of 91%, 99.2%, 83.4%, 99.6% and 98.8%, respectively. The MDCT-CA evaluability of coronary stents was 82.1%. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy for detecting ≥50% in-stent restenosis of 94.1%, 86.7%, 66.7%, 98.1%, and 88.3%, respectively. All CABGs were correctly assessed by MDCT-CA. In a patient-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy of 89.7%, 90.8%, 80.6%, 95.4%, and 90.5%, respectively. CONCLUSIONS: Multidetector computed tomography-CA allows to correctly rule out the presence of significant native coronary artery stenosis, significant in-stent restenosis, and CABG disease in patients referred for TAVR.


Assuntos
Valva Aórtica , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Comorbidade , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Feminino , Doenças das Valvas Cardíacas/epidemiologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Doses de Radiação , Sensibilidade e Especificidade , Stents
10.
Int J Cardiol ; 406: 131997, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556216

RESUMO

AIMS: Myocardial bridging (MB) is a frequent congenital anomaly of the epicardial coronary arteries commonly considered a benign condition. However, in some cases a complex interplay between anatomical, clinical and physiology factors may lead to adverse events, including sudden cardiac death. Coronary CT angiography (CCTA) emerged as the gold standard noninvasive imaging technique for the evaluation of MB. Aim of the study was to evaluate MB prevalence and anatomical features in a large population of patients who underwent CCTA for suspected CAD and to identify potential anatomical and clinical predictors of adverse cardiac events at long-term follow-up. METHODS AND RESULTS: Two-hundred and six patients (mean age 60.3 ± 11.8 years, 128 male) with MB diagnosed at CCTA were considered. A long MB was defined as ≥25 mm of overlying myocardium, whereas a deep MB as ≥2 mm of overlying myocardium. The study endpoint was the sum of the following adverse events: cardiac death, bridge-related acute coronary syndrome, hospitalization for angina or bridge-related ventricular arrhythmias and MB surgical treatment. Of the 206 patients enrolled in the study, 9 were lost to follow-up, whereas 197 (95.6%) had complete follow-up (mean 7.01 ± 3.0 years) and formed the analytic population. Nineteen bridge-related events occurred in 18 patients (acute coronary syndrome in 7, MB surgical treatment in 2 and hospitalization for bridge-related events in 10). Typical angina at the time of diagnosis and long MB resulted as significant independent predictors of adverse outcome. CONCLUSIONS: Typical angina and MB length ≥ 25 mm were independent predictors of cardiac events.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte Miocárdica , Valor Preditivo dos Testes , Humanos , Masculino , Ponte Miocárdica/diagnóstico por imagem , Ponte Miocárdica/complicações , Ponte Miocárdica/epidemiologia , Feminino , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Idoso , Seguimentos , Angiografia Coronária/métodos , Estudos Retrospectivos
11.
Int J Cardiol ; : 132337, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964552

RESUMO

OBJECTIVES: We aimed to investigate the role of feature-tracking (FT) strain in long-term risk stratification of patients with known or suspected coronary artery disease (CAD) who underwent stress cardiac MRI with dipyridamole; to determine if contrast-free stress cardiac MRI with strain measurements could provide comparable prognostic value to myocardial perfusion. MATERIALS AND METHODS: This retrospective study included consecutive patients with stable symptoms suggesting possible cardiac ischemia who underwent stress cardiac MRI with dipyridamole. The mean follow-up period was 5.8 years ±1.2 [SD]. FT cardiac MRI analysis was performed for each patient to obtain 2D global peak circumferential strain (GCS). The primary outcome measure was major adverse cardiac events (MACE), defined as nonfatal myocardial infarction and cardiac death. RESULTS: A total of 729 patients (mean age, 63 years ±10 [SD]; 616 males) were included. MACE occurred in 70 (9.6%) patients. The presence of late gadolinium enhancement (LGE) ([HR] 2.74, [95% CI: 1.53, 4.88]; P < .001) and stress GCS (HR, 1.06 [95% CI: 1.01, 1.12]; P = .016) were independently associated with MACE. A model based on contrast-free assessment of LVEF and stress GCS showed similar performance for predicting MACE than LVEF and perfusion (P = .056). CONCLUSIONS: In patients with known or suspected CAD undergoing stress cardiac MRI with dipyridamole, GCS and LGE presence were independent predictors of MACE. Contrast-free stress cardiac MRI with stress GCS measurement offered prognostic value akin to myocardial perfusion assessment. CLINICAL RELEVANCE STATEMENT: Stress global circumferential strain represented an additional method to predict major adverse cardiac events in patients undergoing stress cardiac MRI, even without the use of contrast agents. This would be of particular significance in patients with severe renal impairment.

12.
Atherosclerosis ; : 117549, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38679562

RESUMO

BACKGROUND AND AIMS: This study investigated the additional prognostic value of epicardial adipose tissue (EAT) volume for major adverse cardiovascular events (MACE) in patients undergoing stress cardiac magnetic resonance (CMR) imaging. METHODS: 730 consecutive patients [mean age: 63 ± 10 years; 616 men] who underwent stress CMR for known or suspected coronary artery disease were randomly divided into derivation (n = 365) and validation (n = 365) cohorts. MACE was defined as non-fatal myocardial infarction and cardiac deaths. A deep learning algorithm was developed and trained to quantify EAT volume from CMR. EAT volume was adjusted for height (EAT volume index). A composite CMR-based risk score by Cox analysis of the risk of MACE was created. RESULTS: In the derivation cohort, 32 patients (8.7 %) developed MACE during a follow-up of 2103 days. Left ventricular ejection fraction (LVEF) < 35 % (HR 4.407 [95 % CI 1.903-10.202]; p<0.001), stress perfusion defect (HR 3.550 [95 % CI 1.765-7.138]; p<0.001), late gadolinium enhancement (LGE) (HR 4.428 [95%CI 1.822-10.759]; p = 0.001) and EAT volume index (HR 1.082 [95 % CI 1.045-1.120]; p<0.001) were independent predictors of MACE. In a multivariate Cox regression analysis, adding EAT volume index to a composite risk score including LVEF, stress perfusion defect and LGE provided additional value in MACE prediction, with a net reclassification improvement of 0.683 (95%CI, 0.336-1.03; p<0.001). The combined evaluation of risk score and EAT volume index showed a higher Harrel C statistic as compared to risk score (0.85 vs. 0.76; p<0.001) and EAT volume index alone (0.85 vs.0.74; p<0.001). These findings were confirmed in the validation cohort. CONCLUSIONS: In patients with clinically indicated stress CMR, fully automated EAT volume measured by deep learning can provide additional prognostic information on top of standard clinical and imaging parameters.

14.
Br J Radiol ; 96(1149): 20220733, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37449675

RESUMO

OBJECTIVES: Aim of the study is to compare manual and semi-automatic measurements for aortic annulus assessment among different operators. METHODS: Eighty patients who underwent TAVI were retrospectively enrolled. The measurements manually performed by an experienced reader for aortic annulus (minimum and maximum diameters, perimeter, area), annulus-to-coronary ostia distance and time needed for the whole evaluation, were collected. The same operator (observer 1) and two less experienced readers (observer 2 and 3, with >5 years and 1 year of experience, respectively) assessed the same measurements using a semi-automatic software. Differences between manual and semi-automatic measurements, reading time and suggested valves size derived by CT were compared. RESULTS: Very good correlations were found between manual and software-aided measurements for aortic annulus area and perimeter in comparison with standard measurements for the three readers (ICC range 0.81-0.98). Good correlations were found for the distance with coronary ostia(0.75-0.79). The same area-derived prosthesis size for manual and semi-automatic measurements was selected in 96% of cases for observer 1; very good correlations were also found for observer 2 and 3 (ICC = 0.89 and 0.88, respectively). Using semi-automatic measurements, the mean time needed for CT images was significantly lower for observers 1 and 2 (1.50 and 1.72versus 3.14 min), respectively. CONCLUSIONS: Pre-TAVI CT using semi-automatic software allows accurate and reproducible measurements, reducing reconstruction time up to 50% and is reliable even for operators with different experience. ADVANCES IN KNOWLEDGE: The use of semi-automatic dedicated software for CT in TAVI planning is reliable even for operators without long time experience and allows accurate and reproducible measurements improving pre-TAVI workflow.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Software , Reprodutibilidade dos Testes
15.
JACC Cardiovasc Imaging ; 16(2): 175-188, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36444769

RESUMO

BACKGROUND: Although cardiac magnetic resonance (CMR) is considered the gold standard for myocardial fibrosis detection, cardiac computed tomography (CCT) is emerging as a promising alternative. OBJECTIVES: The purpose of this study was to assess feasibility and diagnostic accuracy of a comprehensive functional and anatomical evaluation with CCT as compared with CMR in patients with newly diagnosed left ventricular dysfunction (LVD). METHODS: A total of 128 consecutive patients with newly diagnosed LVD were screened. Based on the exclusion criteria, 28 cases were excluded. CCT was performed within 10 days from CMR. Biventricular volumes and ejection fraction, and presence and pattern of delayed enhancement (DE), were determined, along with evaluation of coronary arteries among patients undergoing invasive angiography in the 6 months after CCT. RESULTS: Six cases were excluded because of claustrophobia at CMR. Among the 94 patients who formed the study population, the concordance between CCT and CMR in suggesting the cause of the LVD was high (94.7%, 89/94 patients) in the overall population and was 100% for identifying ischemic cardiomyopathy. The CCT diagnostic rate for DE assessment was also high (96.7%, 1,544/1,598 territories) and similar to that of CMR (97.4%; P = 0.345, CCT vs CMR). Moreover, CCT showed high diagnostic accuracy in the detection of DE (94.8%, 95% CI: 93.6%-95.8%) in a territory-based analysis. Biventricular volumes and function parameters as measured by CCT and CMR were similar, without significant differences with the exception of a modest difference in RV volume. CCT was confirmed to be accurate for assessing arterial coronary circulation. The mean radiation exposure of the whole CCT was 7.78 ± 2.53 mSv (0.84 ± 0.24 mSv for DE). CONCLUSIONS: CCT performed with low-dose whole-heart coverage scanner and high-concentration contrast agent appears an effective noninvasive tool for a comprehensive assessment of patients with newly diagnosed LVD.


Assuntos
Cardiomiopatias , Ventrículos do Coração , Humanos , Ventrículos do Coração/diagnóstico por imagem , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
16.
J Cardiovasc Comput Tomogr ; 17(4): 261-268, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37147147

RESUMO

BACKGROUND: Cardiac computed tomography (CCT) was recently validated to measure extracellular volume (ECV) in the setting of cardiac amyloidosis, showing good agreement with cardiovascular magnetic resonance (CMR). However, no evidence is available with a whole-heart single source, single energy CT scanner in the clinical context of newly diagnosed left ventricular dysfunction. Therefore, the aim of this study was to test the diagnostic accuracy of ECVCCT in patients with a recent diagnosis of dilated cardiomyopathy, having ECVCMR as the reference technique. METHODS: 39 consecutive patients with newly diagnosed dilated cardiomyopathy (LVEF <50%) scheduled for clinically indicated CMR were prospectively enrolled. Myocardial segment evaluability assessment with each technique, agreement between ECVCMR and ECVCCT, regression analysis, Bland-Altman analysis and interclass correlation coefficient (ICC) were performed. RESULTS: Mean age of enrolled patients was 62 â€‹± â€‹11 years, and mean LVEF at CMR was 35.4 â€‹± â€‹10.7%. Overall radiation exposure for ECV estimation was 2.1 â€‹± â€‹1.1 â€‹mSv. Out of 624 myocardial segments available for analysis, 624 (100%) segments were assessable by CCT while 608 (97.4%) were evaluable at CMR. ECVCCT demonstrated slightly lower values compared to ECVCMR (all segments, 31.8 â€‹± â€‹6.5% vs 33.9 â€‹± â€‹8.0%, p â€‹< â€‹0.001). At regression analysis, strong correlations were described (all segments, r â€‹= â€‹0.819, 95% CI: 0.791 to 0.844). On Bland-Altman analysis, bias between ECVCMR and ECVCCT for global analysis was 2.1 (95% CI: -6.8 to 11.1). ICC analysis showed both high intra-observer and inter-observer agreement for ECVCCT calculation (0.986, 95%CI: 0.983 to 0.988 and 0.966, 95%CI: 0.960 to 0.971, respectively). CONCLUSIONS: ECV estimation with a whole-heart single source, single energy CT scanner is feasible and accurate. Integration of ECV measurement in a comprehensive CCT evaluation of patients with newly diagnosed dilated cardiomyopathy can be performed with a small increase in overall radiation exposure.


Assuntos
Cardiomiopatia Dilatada , Humanos , Pessoa de Meia-Idade , Idoso , Cardiomiopatia Dilatada/patologia , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Miocárdio/patologia , Coração , Meios de Contraste , Fibrose
17.
Biomolecules ; 13(10)2023 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-37892152

RESUMO

Circulating small extracellular vesicles (sEVs) contribute to inflammation, coagulation and vascular injury, and have great potential as diagnostic markers of disease. The ability of sEVs to reflect myocardial damage assessed by Cardiac Magnetic Resonance (CMR) in ST-segment elevation myocardial infarction (STEMI) is unknown. To fill this gap, plasma sEVs were isolated from 42 STEMI patients treated by primary percutaneous coronary intervention (pPCI) and evaluated by CMR between days 3 and 6. Nanoparticle tracking analysis showed that sEVs were greater in patients with anterior STEMI (p = 0.0001), with the culprit lesion located in LAD (p = 0.045), and in those who underwent late revascularization (p = 0.038). A smaller sEV size was observed in patients with a low myocardial salvage index (MSI, p = 0.014). Patients with microvascular obstruction (MVO) had smaller sEVs (p < 0.002) and lower expression of the platelet marker CD41-CD61 (p = 0.039). sEV size and CD41-CD61 expression were independent predictors of MVO/MSI (OR [95% CI]: 0.93 [0.87-0.98] and 0.04 [0-0.61], respectively). In conclusion, we provide evidence that the CD41-CD61 expression in sEVs reflects the CMR-assessed ischemic damage after STEMI. This finding paves the way for the development of a new strategy for the timely identification of high-risk patients and their treatment optimization.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Miocárdio/patologia , Imageamento por Ressonância Magnética , Inflamação/patologia
18.
Am Heart J ; 164(4): 576-84, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23067917

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a valid alternative to surgery in high-risk patients with severe aortic stenosis. Aortic annulus (AoA) sizing is crucial for TAVI success. The aim of the study was to compare AoA dimensions measured by multidetector computed tomography (MDCT) vs those obtained with transthoracic (TTE) and transesophageal echocardiography (TEE) for predicting paravalvular aortic regurgitation (PVR) after TAVI. METHODS: Aortic annulus maximum diameter, minimum diameter, and area were assessed using MDCT and compared with TTE and TEE diameter and area for predicting PVR after TAVI in 151 patients (45 men, age 81.2 ± 6.4 years). RESULTS: Aortic annulus maximum, minimum diameter, and area detected by MDCT were 25.04 ± 2.39 mm, 21.27 ± 2.10 mm, and 420.87 ± 76.10 mm(2), respectively. Aortic annulus diameter and area measured by TTE and TEE were 21.14 ± 1.94 mm and 353.82 ± 64.57 mm(2) and 22.04 ± 1.94 mm and 384.33 ± 67.30 mm(2), respectively. A good correlation was found between AoA diameters and area evaluated by MDCT vs TTE and TEE (0.61, 0.65, and 0.69 and 0.61, 0.65, and 0.70, respectively), with a mean difference of 3.90 ± 1.98 mm, 0.13 ± 1.67 mm, and 67.05 ± 55.87 mm(2) and 3.0 ± 2.0 mm, 0.77 ± 1.70 mm, and 36.54 ± 56.43 mm(2), respectively. Grade ≥2 PVR occurred in 46 patients and was related to male gender, higher body mass index, preprocedural aortic regurgitation, and lower mismatch between the nominal area of the implanted prosthesis and AoA area detected by MDCT. CONCLUSIONS: Mismatch between prosthesis area and AoA area detected by MDCT is a better predictor of PVR as compared with echocardiography mismatch. Specific MDCT-based sizing recommendations should be developed.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/patologia , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Tamanho do Órgão
19.
Europace ; 14(2): 209-16, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21933801

RESUMO

AIMS: Chest computed tomography (CT) scanning is increasingly used as an imaging technique in patients undergoing atrial fibrillation (AF) catheter ablation. Chest CT scans visualize organs other than the heart and collateral findings may be identified incidentally. Our study aims to assess the prevalence and clinical relevance of such collateral findings in patients undergoing AF ablation. METHODS AND RESULTS: One hundred and seventy-three patients (127 males, age 59 ± 10 years) underwent chest CT scan for image integration in AF ablation. Collateral findings from visualized thoracic and upper abdominal organs were collected. Findings that required further investigations or treatment according to current guidelines were considered as clinically significant. A total of 164 collateral findings were identified in 97 (56%) patients, and most patients showed abnormalities of the lungs (67 patients, 39%). Forty-nine (28%) patients had clinically significant findings needing further investigation and 17 (10%) of them required specific treatments, including three cases (1.7 %) of lung malignancy. CONCLUSIONS: Chest CT images acquired for integration in AF ablation should be read thoroughly as they may serve as a screening tool for otherwise unrecognized clinically significant conditions of the heart, lungs, or other visualized organs.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Hepatopatias/epidemiologia , Pneumopatias/epidemiologia , Radiografia Torácica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Fibrilação Atrial/diagnóstico por imagem , Comorbidade , Feminino , Humanos , Itália/epidemiologia , Hepatopatias/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco
20.
J Clin Med ; 11(3)2022 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-35159929

RESUMO

Coronary artery disease (CAD) represents the most common cardiovascular disease, with high morbidity and mortality. Historically patients with chest pain of suspected coronary origin have been assessed with functional tests, capable to detect haemodynamic consequences of coronary obstructions through depiction of electrocardiographic changes, myocardial perfusion defects or regional wall motion abnormalities under stress condition. Stress echocardiography (SE), single-photon emission computed tomography (SPECT), positron emission tomography (PET) and cardiovascular magnetic resonance (CMR) represent the functional techniques currently available, and technical developments contributed to increased diagnostic performance of these techniques. More recently, cardiac computed tomography angiography (cCTA) has been developed as a non-invasive anatomical test for a direct visualisation of coronary vessels and detailed description of atherosclerotic burden. Cardiovascular imaging techniques have dramatically enhanced our knowledge regarding physiological aspects and myocardial implications of CAD. Recently, after the publication of important trials, international guidelines recognised these changes, updating indications and level of recommendations. This review aims to summarise current standards with main novelties and specific limitations, and a diagnostic algorithm for up-to-date clinical management is also proposed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA