J Clin Monit Comput ; 36(2): 429-436, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33630220

RESUMO

The finger-cuff system CNAP (CNSystems Medizintechnik, Graz, Austria) allows non-invasive automated measurement of pulse pressure variation (PPVCNAP). We sought to validate the PPVCNAP-algorithm and investigate the agreement between PPVCNAP and arterial catheter-derived manually calculated pulse pressure variation (PPVINV). This was a prospective method comparison study in patients having neurosurgery. PPVINV was the reference method. We applied the PPVCNAP-algorithm to arterial catheter-derived blood pressure waveforms (PPVINV-CNAP) and to CNAP finger-cuff-derived blood pressure waveforms (PPVCNAP). To validate the PPVCNAP-algorithm, we compared PPVINV-CNAP to PPVINV. To investigate the clinical performance of PPVCNAP, we compared PPVCNAP to PPVINV. We used Bland-Altman analysis (absolute agreement), Deming regression, concordance, and Cohen's kappa (predictive agreement for three pulse pressure variation categories). We analyzed 360 measurements from 36 patients. The mean of the differences between PPVINV-CNAP and PPVINV was -0.1% (95% limits of agreement (95%-LoA) -2.5 to 2.3%). Deming regression showed a slope of 0.99 (95% confidence interval (95%-CI) 0.91 to 1.06) and intercept of -0.02 (95%-CI -0.52 to 0.47). The predictive agreement between PPVINV-CNAP and PPVINV was 92% and Cohen's kappa was 0.79. The mean of the differences between PPVCNAP and PPVINV was -1.0% (95%-LoA-6.3 to 4.3%). Deming regression showed a slope of 0.85 (95%-CI 0.78 to 0.91) and intercept of 0.10 (95%-CI -0.34 to 0.55). The predictive agreement between PPVCNAP and PPVINV was 82% and Cohen's kappa was 0.48. The PPVCNAP-algorithm reliably calculates pulse pressure variation compared to manual offline pulse pressure variation calculation when applied on the same arterial blood pressure waveform. The absolute and predictive agreement between PPVCNAP and PPVINV are moderate.


Assuntos
Neurocirurgia , Pressão Arterial/fisiologia , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Humanos , Estudos Prospectivos
2.
J Clin Monit Comput ; 30(4): 487-93, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26227161

RESUMO

The CNAP system (CNSystems Medizintechnik AG, Graz, Austria) provides noninvasive continuous arterial pressure measurements by using the volume clamp method. Recently, an algorithm for the determination of cardiac output by pulse contour analysis of the arterial waveform recorded with the CNAP system became available. We evaluated the agreement of the continuous noninvasive cardiac output (CNCO) measurements by CNAP in comparison with cardiac output measurements invasively obtained using transpulmonary thermodilution (TDCO). In this proof-of-concept analysis we studied 38 intensive care unit patients from a previously set up database containing CNAP-derived arterial pressure data and TDCO values obtained with the PiCCO system (Pulsion Medical Systems SE, Feldkirchen, Germany). We applied the new CNCO algorithm retrospectively to the arterial pressure waveforms recorded with CNAP and compared CNCO with the corresponding TDCO values (criterion standard). Analyses were performed separately for (1) CNCO calibrated to the first TDCO (CNCO-cal) and (2) CNCO autocalibrated to biometric patient data (CNCO-auto). We did not perform an analysis of trending capabilities because the patients were hemodynamically stable. The median age and APACHE II score of the 22 male and 16 female patients was 63 years and 18 points, respectively. 18 % were mechanically ventilated and in 29 % vasopressors were administered. Mean ± standard deviation for CNCO-cal, CNCO-auto, and TDCO was 8.1 ± 2.7, 6.4 ± 1.9, and 7.8 ± 2.4 L/min, respectively. For CNCO-cal versus TDCO, Bland-Altman analysis demonstrated a mean difference of +0.2 L/min (standard deviation 1.0 L/min; 95 % limits of agreement -1.7 to +2.2 L/min, percentage error 25 %). For CNCO-auto versus TDCO, the mean difference was -1.4 L/min (standard deviation 1.8 L/min; 95 % limits of agreement -4.9 to +2.1 L/min, percentage error 45 %). This pilot analysis shows that CNCO determination is feasible in critically ill patients. A percentage error of 25 % indicates acceptable agreement between CNCO-cal and TDCO. The mean difference, the standard deviation, and the percentage error between CNCO-auto and TDCO were higher than between CNCO-cal and TDCO. A hyperdynamic cardiocirculatory state in a substantial number of patients and the hemodynamic stability making trending analysis impossible are main limitations of our study.


Assuntos
Algoritmos , Débito Cardíaco , Monitorização Fisiológica/estatística & dados numéricos , Idoso , Cuidados Críticos , Estado Terminal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Análise de Onda de Pulso/estatística & dados numéricos , Estudos Retrospectivos , Termodiluição/estatística & dados numéricos
3.
Nat Commun ; 12(1): 1387, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33654082

RESUMO

Wearable sensors to continuously measure blood pressure and derived cardiovascular variables have the potential to revolutionize patient monitoring. Current wearable methods analyzing time components (e.g., pulse transit time) still lack clinical accuracy, whereas existing technologies for direct blood pressure measurement are too bulky. Here we present an innovative art of continuous noninvasive hemodynamic monitoring (CNAP2GO). It directly measures blood pressure by using a volume control technique and could be used for small wearable sensors integrated in a finger-ring. As a software prototype, CNAP2GO showed excellent blood pressure measurement performance in comparison with invasive reference measurements in 46 patients having surgery. The resulting pulsatile blood pressure signal carries information to derive cardiac output and other hemodynamic variables. We show that CNAP2GO can self-calibrate and be miniaturized for wearable approaches. CNAP2GO potentially constitutes the breakthrough for wearable sensors for blood pressure and flow monitoring in both ambulatory and in-hospital clinical settings.


Assuntos
Determinação da Pressão Arterial/métodos , Adulto , Algoritmos , Pressão Sanguínea , Calibragem , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Monitorização Fisiológica/instrumentação , Pulso Arterial , Processamento de Sinais Assistido por Computador , Software , Adulto Jovem
5.
Auton Neurosci ; 97(1): 45-54, 2002 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-12036186

RESUMO

Orthostatic hypotension in patients with cobalamin (Cbl) deficiency has been reported previously in isolated cases but we are not aware of detailed systematic studies of hemodynamic and autonomic nervous system function in patients with cobalamin deficiency. We investigated hemodynamic and autonomic responses to 60 degrees passive head up tilt (HUT) in 21 patients with vitamin B12 deficiency, 21 healthy age-matched control subjects and 9 age-matched patients with diabetes mellitus (DM) and established diabetic neuropathy. To systematically assess hemodynamic and autonomic nervous system function, we performed measurements of heart rate, beat-to-beat systolic and diastolic blood pressure, stroke index, cardiac index, total peripheral resistance index, total power, low (LF) and high (HF) frequency oscillatory component of heart rate variability, LF/HF ratio and spontaneous baroreflex sensitivity. As compared to controls, we found a significant fall of systolic blood pressure during 60 consecutive beats directly after head up tilt; furthermore, a significantly blunted fall of stroke index, cardiac index and a lack of increase of total peripheral resistance index for the duration of tilt in patients with diabetes mellitus and in patients with vitamin B12 deficiency. As compared to controls, we observed an altered response of spectral indices of sympathetic activation and vagal withdrawal and an impaired modulation of baroreflex sensitivity during head up tilt suggestive of a complex modification in the neural control activities in patients with cobalamin deficiency, which was comparable to that observed in patients with diabetes mellitus and established autonomic neuropathy. The results suggest that vitamin B12 deficiency causes autonomic dysfunction with similar hemodynamic consequences and patterns of autonomic failure as seen in diabetic autonomic neuropathy. Defective sympathetic activation may be the cause for orthostatic hypotension, which is occasionally seen in patients with vitamin B12 deficiency. It is concluded that patients with orthostatic hypotension should be screened for cobalamin deficiency.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Diabetes Mellitus/fisiopatologia , Hemodinâmica , Deficiência de Vitamina B 12/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Barorreflexo/fisiologia , Pressão Sanguínea , Eletrocardiografia , Feminino , Frequência Cardíaca , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA