Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Clin Chem Lab Med ; 49(9): 1439-46, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21702699

RESUMO

Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.


Assuntos
Fosfatase Alcalina/metabolismo , Ensaios Enzimáticos/normas , Enzimas , Agências Internacionais/normas , Temperatura , Adolescente , Adulto , Calibragem , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Projetos de Pesquisa , Soluções , Adulto Jovem
2.
Clin Chem Lab Med ; 48(6): 795-803, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20441466

RESUMO

BACKGROUND: A new reference material for the liver enzyme aspartate transaminase (AST) (L-aspartate: 2-oxoglutarate-aminotransferase, EC 2.6.1.1), also called aspartate aminotransferase (ASAT), has been developed under the code ERM-AD457/IFCC. This certified reference material (CRM) for AST has been produced from a human type recombinant AST expressed in Escherichia coli and a buffer containing bovine serum albumin, and has been lyophilised. METHODS: The homogeneity and the stability of the material have been tested and the catalytic activity concentration has been characterised by 12 laboratories using the reference procedure for AST at 37 degrees C from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). RESULTS: The certified catalytic activity concentration and certified uncertainty of AST in the reconstituted material are (1.74+/-0.05) microkat/L or (104.6+/-2.7) U/L (with a coverage factor k=2; 95% confidence interval). CONCLUSIONS: Both the certified value and uncertainty are traceable to the International System of Units (SI). The material is aiming to control the IFCC reference procedure for AST at 37 degrees C, which will then be used to assign values to calibrants and control materials. The present paper highlights the scientific challenges and innovations which were encountered during the development of this new CRM.


Assuntos
Aspartato Aminotransferases/normas , Ensaios Enzimáticos Clínicos/normas , Animais , Aspartato Aminotransferases/análise , Aspartato Aminotransferases/genética , Bovinos , Ensaios Enzimáticos Clínicos/métodos , Humanos , Proteínas Recombinantes/análise , Proteínas Recombinantes/genética , Proteínas Recombinantes/normas , Padrões de Referência , Soroalbumina Bovina/química , Incerteza
3.
Br J Haematol ; 144(2): 176-84, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19036113

RESUMO

Prospective studies on the risk of malignant transformation in patients with monoclonal gammopathy of undetermined significance (MGUS) and factors predictive of survival are lacking. The Dutch Comprehensive Cancer Centre West, comprising 1.6 million inhabitants, initiated a prospective hospital-based cohort study on 1464 patients with newly diagnosed M-proteinaemia, median age 73 (17-103) years. M-protein related diagnoses, patients' characteristics, laboratory investigations, bone marrow examinations and skeletal X-rays were registered with a yearly follow-up. Main endpoints were death, or new diagnoses of multiple myeloma and non-Hodgkin lymphoma. Kaplan-Meier survival curves were compared with age- and gender-matched survival data from the total Dutch population. Cumulative malignant transformation was corrected for death using a competing risk model. Risk factors for transformation or death were analyzed by univariate and multivariate analyses. In 1007 MGUS-patients, malignant transformation was associated with rising M-protein levels, IgA and IgM isotype and occurred at a yearly rate of 0.4%. All MGUS patients survived less than a matched cohort of the Dutch population, even in the absence of M-protein-associated comorbidity. Serum albumin levels at entry appeared highly predictive for survival. M-proteinaemia is not an innocent symptom. Although malignant transformation occurs rarely, survival is shortened irrespective of comorbidity.


Assuntos
Proteínas do Mieloma/análise , Paraproteinemias/sangue , Isoformas de Proteínas/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Transformação Celular Neoplásica , Progressão da Doença , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Linfoma não Hodgkin/mortalidade , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/mortalidade , Paraproteinemias/mortalidade , Estudos Prospectivos , Risco , Taxa de Sobrevida , Adulto Jovem
4.
Clin Chem Lab Med ; 40(6): 643-8, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12211663

RESUMO

This paper is the third in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials tamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 1.


Assuntos
Temperatura Corporal , Enzimas/metabolismo , Química Clínica/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Controle de Qualidade , Padrões de Referência , Termodinâmica
5.
Clin Chem Lab Med ; 40(6): 635-42, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12211662

RESUMO

This paper is the second in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation. The pro- described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 3.


Assuntos
Temperatura Corporal , Enzimas/metabolismo , Química Clínica/métodos , Química Clínica/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Padrões de Referência , Termodinâmica
6.
Clin Chem Lab Med ; 40(7): 718-24, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241021

RESUMO

This paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 2.


Assuntos
Alanina Transaminase/análise , Alanina Transaminase/normas , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Valores de Referência , Soluções
7.
Clin Chem Lab Med ; 40(7): 725-33, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241022

RESUMO

This paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 3.


Assuntos
Aspartato Aminotransferases/análise , Aspartato Aminotransferases/normas , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Cinética , Valores de Referência , Soluções
8.
Clin Chem Lab Med ; 40(7): 734-8, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241023

RESUMO

This paper is the sixth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 1.


Assuntos
gama-Glutamiltransferase/análise , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Cinética , Valores de Referência , Soluções , gama-Glutamiltransferase/normas
9.
Clin Chem Lab Med ; 40(6): 631-4, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12211661

RESUMO

This paper is the first in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and with the certification of reference preparations. Other parts deal with: Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic fication of Four Reference Materials for the Determination of Enzymatic Activity of y-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation.


Assuntos
Enzimas/metabolismo , Catálise , Química Clínica/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Garantia da Qualidade dos Cuidados de Saúde , Padrões de Referência , Reprodutibilidade dos Testes , Temperatura , Termodinâmica
10.
Clin Chem Lab Med ; 40(7): 739-45, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241024

RESUMO

This paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase. A document describing the determination of preliminary reference values is also in preparation. The certification of the catalytic activity concentrations as determined by the recently elaborated IFCC primary reference methods at 37 degrees C of four enzyme preparations, namely IRMM/IFCC 452 (gamma-glutamyltransferase), IRMM/IFCC 453 (lactate dehydrogenase 1), IRMM/IFCC 454 (alanine aminotransferase) and IRMM/IFCC 455 (creatine kinase) is described. Homogeneity data were derived from previous results. Stability was assessed using recently obtained data as well as data from previous stability studies. The collaborative study for value assignment was performed under a strict quality control scheme to ensure traceability to the primary reference method. Uncertainty of the materials was assessed in compliance with the Guide to the Expression of Uncertainty in Measurement. The certified values obtained at 37 degrees C are 1.90 microkat/l +/- 0.04 microkat/l (114.1 U/l +/- 2.4 U/l), for gamma-glutamyltransferase, 8.37 microkat/l +/- 0.12 microkat/l (502 U/l +/- 7 U/l), for lactate dehydrogenase 1, 3.09 microkat/l +/- 0.07 microkat/l (186 U/l +/- 4 U/l), for alanine aminotransferase and 1.68 microkat/l +/- 0.07 microkat/l (101 U/l +/- 4 U/l), for creatine kinase. The materials are intended for internal quality control as well as for the evaluation of test systems as required by recent European Union legislation. Furthermore, the materials can be used to transfer accuracy from a reference method to a routine procedure provided the procedures exhibit the same analytical specificity and the certified materials are commutable.


Assuntos
Enzimas/normas , Guias como Assunto , Alanina Transaminase/análise , Alanina Transaminase/normas , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Creatina Quinase/análise , Creatina Quinase/normas , Enzimas/análise , Humanos , L-Lactato Desidrogenase/análise , L-Lactato Desidrogenase/normas , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , gama-Glutamiltransferase/análise , gama-Glutamiltransferase/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA