Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Radiol Med ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39043979

RESUMO

OBJECTIVES: To evaluate the ability of 50-keV virtual monoenergetic images (VMI) to depict abdominal arteries in abdominal CT angiography (CTA) compared with 70-keV VMI with photon-counting detector CT (PCD-CT). METHODS: Fifty consecutive patients who underwent multiphase abdominal scans between March and April 2023 were included. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were quantitatively assessed for the abdominal aorta (AA), celiac artery (CeA), superior mesenteric artery (SMA), renal artery (RA), and right hepatic artery (RHA) at both 50- and 70-keV VMI. In addition, 3D images from CTA were analyzed to measure arterial lengths and evaluate the visualization of distal branches. RESULTS: Significantly higher SNR and CNR were observed at 50-keV compared to 70-keV VMI for all arteries: AA (36.54 and 48.28 vs. 25.70 and 28.46), CeA (22.39 and 48.38 vs. 19.09 and 29.15), SMA (23.34 and 49.34 vs. 19.67 and 29.71), RA (22.88 and 48.84 vs. 20.15 and 29.41), and RHA (14.38 and 44.41 vs. 13.45 and 27.18), all p < 0.05. Arterial lengths were also significantly longer at 50-keV: RHA (192.6 vs. 180.3 mm), SMA (230.9 vs. 216.5 mm), and RA (95.9 vs. 92.0 mm), all p < 0.001. CONCLUSION: In abdominal CTA with PCD-CT, 50-keV VMI demonstrated superior quantitative image quality compared to 70-keV VMI. In addition, 50-keV VMI 3D CTA allowed better visualization of abdominal artery branches, highlighting its potential clinical advantage for improved imaging and detailed assessment of abdominal arteries.

2.
Ann Surg Oncol ; 30(5): 2964-2973, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36920588

RESUMO

PURPOSE: To investigate the clinical practices of diagnosing multicystic cervical lesions as a means to develop a more appropriate diagnostic algorithm for gastric-type adenocarcinoma (GAS) and its precursors. METHODS: Clinical information for 159 surgically treated patients for multicystic disease of the uterine cervix was collected from 15 hospitals. We performed a central review of the MRI and pathological findings. The MRI findings were categorized into four types including two newly proposed imaging features based on the morphology and distribution of cysts, and the diagnosis accuracy was assessed. Among the four MRI types, types 1 and 2 were categorized as benign lesions that included LEGH; type 3 were precancerous lesions (with an assumption of atypical LEGH); and type 4 were malignant lesions. RESULTS: The central pathological review identified 56 cases of LEGH, seven with GAS, four with another form of carcinoma, and 92 with benign disease. In clinical practice, over-diagnosis of malignancy (suspicion of MDA) occurred for 12/19 cases (63.2%) and under-diagnosis of malignancy occurred for 4/11 (36%). Among the 118 patients who had a preoperative MRI and underwent a hysterectomy, type 3 or 4 MRI findings in conjunction with abnormal cytology were positively indicative of premalignancy or malignancy, with a sensitivity and specificity of 61.1% and 96.7%, respectively. CONCLUSIONS: Although the correct preoperative diagnosis of cervical cancer with a multicystic lesion is challenging, the combination of cytology and MRI findings creates a more appropriate diagnostic algorithm that significantly improves the diagnostic accuracy for differentiating benign disease from premalignancy and malignancy.


Assuntos
Adenocarcinoma , Lesões Pré-Cancerosas , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/cirurgia , Colo do Útero/cirurgia , Colo do Útero/patologia , Adenocarcinoma/cirurgia , Adenocarcinoma/patologia , Lesões Pré-Cancerosas/diagnóstico , Lesões Pré-Cancerosas/cirurgia , Lesões Pré-Cancerosas/patologia , Imageamento por Ressonância Magnética
3.
J Comput Assist Tomogr ; 47(5): 698-703, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37707398

RESUMO

OBJECTIVE: To evaluate the image quality and lesion detectability of pancreatic phase thin-slice computed tomography (CT) images reconstructed with a deep learning-based reconstruction (DLR) algorithm compared with filtered-back projection (FBP) and hybrid iterative reconstruction (IR) algorithms. METHODS: Fifty-three patients who underwent dynamic contrast-enhanced CT including pancreatic phase were enrolled in this retrospective study. Pancreatic phase thin-slice (0.625 mm) images were reconstructed with each FBP, hybrid IR, and DLR. Objective image quality and signal-to-noise ratio of the pancreatic parenchyma, and contrast-to-noise ratio of pancreatic lesions were compared between the 3 reconstruction algorithms. Two radiologists independently assessed the image quality of all images. The diagnostic performance for the detection of pancreatic lesions was compared among the reconstruction algorithms using jackknife alternative free-response receiver operating characteristic analysis. RESULTS: Deep learning-based reconstruction resulted in significantly lower image noise and higher signal-to-noise ratio and contrast-to-noise ratio than hybrid IR and FBP ( P < 0.001). Deep learning-based reconstruction also yielded significantly higher visual scores than hybrid IR and FBP ( P < 0.01). The diagnostic performance of DLR for detecting pancreatic lesions was highest for both readers, although a significant difference was found only between DLR and FBP in one reader ( P = 0.02). CONCLUSIONS: Deep learning-based reconstruction showed improved objective and subjective image quality of pancreatic phase thin-slice CT relative to other reconstruction algorithms and has potential for improving lesion detectability.


Assuntos
Aprendizado Profundo , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Neoplasias Pancreáticas/diagnóstico por imagem
4.
Radiol Med ; 128(6): 629-643, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37120661

RESUMO

OBJECTIVES: To compare the image quality of high-resolution diffusion-weighted imaging (DWI) using multiplexed sensitivity encoding (MUSE) versus reduced field-of-view (rFOV) techniques in endometrial cancer (EC) and to compare the diagnostic performance of these techniques with that of dynamic contrast-enhanced (DCE) MRI for assessing myometrial invasion of EC. METHODS: MUSE-DWI and rFOV-DWI were obtained preoperatively in 58 women with EC. Three radiologists assessed the image quality of MUSE-DWI and rFOV-DWI. For 55 women who underwent DCE-MRI, the same radiologists assessed the superficial and deep myometrial invasion using MUSE-DWI, rFOV-DWI, and DCE-MRI. Qualitative scores were compared using the Wilcoxon signed-rank test. Receiver operating characteristic analysis was performed to compare the diagnostic performance. RESULTS: Artifacts, sharpness, lesion conspicuity, and overall quality were significantly better with MUSE-DWI than with rFOV-DWI (p < 0.05). The area under the curve (AUC) of MUSE-DWI, rFOV-DWI, and DCE-MRI for the assessment of myometrial invasion were not significantly different except for significantly higher AUC of MUSE-DWI than that of DCE-MRI for superficial myometrial invasion (0.76 for MUSE-DWI and 0.64 for DCE-MRI, p = 0.049) and for deep myometrial invasion (0.92 for MUSE-DWI and 0.80 for DCE-MRI, p = 0.022) in one observer, and that of rFOV-DWI for deep myometrial invasion in another observer (0.96 for MUSE-DWI and 0.89 for rFOV-MRI, p = 0.048). CONCLUSION: MUSE-DWI exhibits better image quality than rFOV-DWI. MUSE-DWI and rFOV-DWI shows almost equivalent diagnostic performance compared to DCE-MRI for assessing superficial and deep myometrial invasion in EC although MUSE-DWI may be helpful for some radiologists.


Assuntos
Alprostadil , Neoplasias do Endométrio , Feminino , Humanos , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia
5.
Radiographics ; 42(7): 2095-2111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36083804

RESUMO

Borderline epithelial ovarian tumors are a distinct pathologic entity characterized by increased epithelial proliferation and nuclear atypia, but without frank stromal invasion. Borderline tumor (BT) is now considered to represent an intermediate phase in the stepwise progression from benign to malignant ovarian epithelial tumor. Since BTs commonly manifest at early stages in women of reproductive age and are associated with a good prognosis, making the correct diagnosis is important in determining whether a patient is a candidate for fertility-sparing surgery. There are six histologic BT subtypes (serous, mucinous, seromucinous, endometrioid, clear cell, and Brenner), and each has different MRI features, reflecting their unique histologic architectures. Radiologists should be aware of the MRI features that can suggest BTs. These features include a hyperintense papillary architecture with hypointense internal branching, which can be observed with serous and seromucinous BTs on T2-weighted images; aggregates of microcysts that have hypointensity on T2-weighted images and reticular enhancement on contrast-enhanced T2-weighted images, which can be seen with mucinous BTs; and moderately high signal intensity on diffusion-weighted images along with relatively high apparent diffusion coefficient values, which can be observed regardless of the histologic subtype. Nevertheless, because the imaging features of BTs overlap with those of many benign lesions (eg, cystadenoma and cystadenofibroma, decidualized endometriosis, and polypoid endometriosis) and malignant tumors (ovarian cancers and metastases), histologic confirmation is required for the final diagnosis. Special emphasis is placed on the MRI features of BTs, pathologic correlation, and the challenges related to diagnosis. ©RSNA, 2022.


Assuntos
Carcinoma , Endometriose , Neoplasias Ovarianas , Feminino , Humanos , Neoplasias Ovarianas/patologia , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos
6.
Radiology ; 289(1): 255-260, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29944085

RESUMO

Purpose To examine the diagnostic performance of high-spatial-resolution (HSR) CT with 0.25-mm section thickness for evaluating renal artery in-stent restenosis. Materials and Methods A 0.05-mm wire phantom and vessel phantoms with renal stents with in-stent stenotic sections of varying diameters were scanned with both an HSR CT scanner equipped with 160-section multi-detector rows (0.25-mm section thickness) and a conventional CT scanner. The wire phantom was used to analyze modulation transfer function (MTF). With the vessel phantoms, the error rates were calculated as the absolute difference between the measured diameters and true diameters divided by the true diameters at the narrowing sections. For qualitative evaluation, overall image quality and diagnostic accuracy for evaluating stenosis in three stages were assessed by two radiologists. Statistical analyses included the paired t test, Wilcoxon signed-rank test, and McNemar test. Results HSR CT achieved 24.3 line pairs per centimeter ± 0.5 (standard deviation) and 29.1 line pairs per centimeter ± 0.4 at 10% and 2% MTF, respectively; and conventional CT was 12.5 line pairs per centimeter ± 0.1 and 14.3 line pairs per centimeter ± 0.1 at 10% and 2% MTF, respectively. The mean error rate of the measured diameter at HSR CT (8.0% ± 5.8) was significantly lower than that at at conventional CT (16.9% ± 9.3; P < .001). Image quality at HSR CT was significantly better than that at conventional CT (P < .001), but HSR CT was not significantly superior to conventional CT in terms of diagnostic accuracy. Conclusion Compared with conventional CT, high-spatial-resolution CT achieved spatial resolutions of up to 29 line pairs per centimeter at 2% modulation transfer function and yielded improved measurement accuracy for the evaluation of in-stent restenosis in a phantom study of renal artery stents. Published under a CC BY 4.0 license.


Assuntos
Oclusão de Enxerto Vascular/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Stents , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Humanos , Modelos Biológicos , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação
8.
Jpn J Radiol ; 42(6): 599-611, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38351253

RESUMO

PURPOSE: Liver and pancreatic fibrosis is associated with diabetes mellitus (DM), and liver fibrosis is associated with pancreatic fibrosis. This study aimed to investigate the relationship between the hepatic and pancreatic extracellular volume fractions (fECVs), which correlate with tissue fibrosis, and their relationships with DM and pre-DM (pDM). MATERIAL AND METHODS: We included 100 consecutive patients with known or suspected liver and/or pancreatic diseases who underwent contrast-enhanced CT. Patients were classified as nondiabetes, pDM, and DM with hemoglobin A1c (HbA1c) levels of < 5.7%, 5.7%-6.5%, and ≥ 6.5% or fasting plasma glucose (FPG) levels of < 100, 100-125 mg/dL, and ≥ 126 mg/dL, respectively. Subtraction images between unenhanced and equilibrium-phase images were prepared. The liver and the pancreas were automatically extracted using a high-speed, three-dimensional image analysis system, and their respective mean CT values were calculated. The enhancement degree of the aorta (Δaorta) was measured. fECV was calculated using the following equation: fECV = (100 - hematocrit) * Δliver or pancreas/Δaorta. Differences were investigated in hepatic and pancreatic fECVs among the three groups, and the correlation between each two in hepatic fECV, pancreatic fECV, and HbA1c was determined. RESULTS: The pancreatic fECV, which was positively correlated with the hepatic fECV and HbA1c (r = 0.51, P < 0.001, and r = 0.51, P < 0.001, respectively), significantly differed among the three groups (P < 0.001) and was significantly greater in DM than in pDM or nondiabetes and in pDM with nondiabetes (P < 0.001). Hepatic fECV was significantly greater in DM than in nondiabetes (P < 0.05). CONCLUSION: The pancreatic fECV and pDM/DM are closely related.


Assuntos
Meios de Contraste , Fígado , Estado Pré-Diabético , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Fígado/diagnóstico por imagem , Estado Pré-Diabético/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Adulto , Diabetes Mellitus/diagnóstico por imagem , Idoso de 80 Anos ou mais , Imageamento Tridimensional/métodos , Cirrose Hepática/diagnóstico por imagem , Estudos Retrospectivos
9.
Magn Reson Med Sci ; 23(2): 214-224, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36990740

RESUMO

PURPOSE: To compare the effects of deep learning reconstruction (DLR) on respiratory-triggered T2-weighted MRI of the liver between single-shot fast spin-echo (SSFSE) and fast spin-echo (FSE) sequences. METHODS: Respiratory-triggered fat-suppressed liver T2-weighted MRI was obtained with the FSE and SSFSE sequences at the same spatial resolution in 55 patients. Conventional reconstruction (CR) and DLR were applied to each sequence, and the SNR and liver-to-lesion contrast were measured on FSE-CR, FSE-DLR, SSFSE-CR, and SSFSE-DLR images. Image quality was independently assessed by three radiologists. The results of the qualitative and quantitative analyses were compared among the four types of images using repeated-measures analysis of variance or Friedman's test for normally and non-normally distributed data, respectively, and a visual grading characteristics (VGC) analysis was performed to evaluate the image quality improvement by DLR on the FSE and SSFSE sequences. RESULTS: The liver SNR was lowest on SSFSE-CR and highest on FSE-DLR and SSFSE-DLR (P < 0.01). The liver-to-lesion contrast did not differ significantly among the four types of images. Qualitatively, noise scores were worst on SSFSE-CR but best on SSFSE-DLR because DLR significantly reduced noise (P < 0.01). In contrast, artifact scores were worst both on FSE-CR and FSE-DLR (P < 0.01) because DLR did not reduce the artifacts. Lesion conspicuity was significantly improved by DLR compared with CR in the SSFSE (P < 0.01) but not in FSE sequences for all readers. Overall image quality was significantly improved by DLR compared with CR for all readers in the SSFSE (P < 0.01) but only one reader in the FSE (P < 0.01). The mean area under the VGC curve values for the FSE-DLR and SSFSE-DLR sequences were 0.65 and 0.94, respectively. CONCLUSION: In liver T2-weighted MRI, DLR produced more marked improvements in image quality in SSFSE than in FSE.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias Hepáticas/patologia , Artefatos
10.
Abdom Radiol (NY) ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888738

RESUMO

Photon-counting CT has a completely different detector mechanism than conventional energy-integrating CT. In the photon-counting detector, X-rays are directly converted into electrons and received as electrical signals. Photon-counting CT provides virtual monochromatic images with a high contrast-to-noise ratio for abdominal CT imaging and may improve the ability to visualize small or low-contrast lesions. In addition, photon-counting CT may offer the possibility of reducing radiation dose. This review provides an overview of the actual clinical operation of photon-counting CT and its diagnostic utility in abdominal imaging. We also describe the clinical implications of photon-counting CT including imaging of hepatocellular carcinoma, liver metastases, hepatic steatosis, pancreatic cancer, intraductal mucinous neoplasm of the pancreas, and thrombus.

11.
Magn Reson Med Sci ; 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37899224

RESUMO

PURPOSE: To compare objective and subjective image quality, lesion conspicuity, and apparent diffusion coefficient (ADC) of high-resolution multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) with conventional DWI (c-DWI) and reduced FOV DWI (rFOV-DWI) in prostate MRI. METHODS: Forty-seven patients who underwent prostate MRI, including c-DWI, rFOV-DWI, and MUSE-DWI, were retrospectively evaluated. SNR and ADC of normal prostate tissue and contrast-to-noise ratio (CNR) and ADC of prostate cancer (PCa) were measured and compared between the three sequences. Image quality and lesion conspicuity were independently graded by two radiologists using a 5-point scale and compared between the three sequences. RESULTS: The SNR of normal prostate tissue was significantly higher with rFOV-DWI than with the other two DWI techniques (P ≤ 0.01). The CNR of the PCa was significantly higher with rFOV-DWI than with MUSE-DWI (P < 0.05). The ADC of normal prostate tissue measured by rFOV-DWI was lower than that measured by MUSE-DWI and c-DWI (P < 0.01), while there was no difference in the ADC of cancers. In the qualitative analysis, MUSE-DWI showed significantly higher scores than rFOV-DWI and c-DWI for visibility of anatomy and overall image quality in both readers, and significantly higher scores for distortion in one of the two readers (P < 0.001). There was no difference in lesion conspicuity between the three sequences. CONCLUSION: High-resolution MUSE-DWI showed higher image quality and reduced distortion compared to c-DWI, while maintaining a wide FOV and similar ADC quantification, although no difference in lesion conspicuity was observed.

12.
Invest Radiol ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37975732

RESUMO

OBJECTIVE: The aim of this study was to evaluate the impact of ultra-high-resolution acquisition and deep learning reconstruction (DLR) on the image quality and diagnostic performance of T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) imaging of the rectum. MATERIALS AND METHODS: This prospective study included 34 patients who underwent magnetic resonance imaging (MRI) for initial staging or restaging of rectal tumors. The following 4 types of oblique axial PROPELLER images perpendicular to the tumor were obtained: a standard 3-mm slice thickness with conventional reconstruction (3-CR) and DLR (3-DLR), and 1.2-mm slice thickness with CR (1.2-CR) and DLR (1.2-DLR). Three radiologists independently evaluated the image quality and tumor extent by using a 5-point scoring system. Diagnostic accuracy was evaluated in 22 patients with rectal cancer who underwent surgery after MRI without additional neoadjuvant therapy (median interval between MRI and surgery, 22 days). The signal-to-noise ratio and tissue contrast were measured on the 4 types of PROPELLER imaging. RESULTS: 1.2-DLR imaging showed the best sharpness, overall image quality, and rectal and lesion conspicuity for all readers (P < 0.01). Of the assigned scores for tumor extent, extramural venous invasion (EMVI) scores showed moderate agreement across the 4 types of PROPELLER sequences in all readers (intraclass correlation coefficient, 0.60-0.71). Compared with 3-CR imaging, the number of cases with MRI-detected extramural tumor spread was significantly higher with 1.2-DLR imaging (19.0 ± 2.9 vs 23.3 ± 0.9, P = 0.03), and the number of cases with MRI-detected EMVI was significantly increased with 1.2-CR, 3-DLR, and 1.2-DLR imaging (8.0 ± 0.0 vs 9.7 ± 0.5, 11.0 ± 2.2, and 12.3 ± 1.7, respectively; P = 0.02). For the diagnosis of histopathologic extramural tumor spread, 3-CR and 1.2-CR had significantly higher specificity than 3-DLR and 1.2-DLR imaging (0.75 and 0.78 vs 0.64 and 0.58, respectively; P = 0.02), and only 1.2-CR had significantly higher accuracy than 3-CR imaging (0.83 vs 0.79, P = 0.01). The accuracy of MRI-detected EMVI with reference to pathological EMVI was significantly lower for 3-CR and 3-DLR compared with 1.2-CR (0.77 and 0.74 vs 0.85, respectively; P < 0.01), and was not significantly different between 1.2-CR and 1.2-DLR (0.85 vs 0.80). Using any pathological venous invasion as the reference standard, the accuracy of MRI-detected EMVI was significantly the highest with 1.2-DLR, followed by 1.2-CR, 3-CR, and 3-DLR (0.71 vs 0.67 vs 0.59 vs 0.56, respectively; P < 0.01). The signal-to-noise ratio was significantly highest with 3-DLR imaging (P < 0.05). There were no significant differences in tumor-to-muscle contrast between the 4 types of PROPELLER imaging. CONCLUSIONS: Ultra-high-resolution PROPELLER T2-weighted imaging of the rectum combined with DLR improved image quality, increased the number of cases with MRI-detected extramural tumor spread and EMVI, but did not improve diagnostic accuracy with respect to pathology in rectal cancer, possibly because of false-positive MRI findings or false-negative pathologic findings.

13.
Eur J Radiol ; 150: 110271, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35334243

RESUMO

PURPOSE: A newly developed Adaptive Image Receive (AIR) coil is designed to be more flexible to conform to the human body habitus, and may improve image quality by reducing the distance between the coil element and the imaging subject. This study evaluated the AIR coil's usefulness for liver MR imaging at 3.0 T in comparison with that of a conventional coil retrospectively. METHOD: The study population comprised 50 consecutive patients, who underwent follow-up liver MR examinations with a 3.0-T MR system using both an AIR coil and a conventional coil to evaluate hepatocellular carcinoma. Three-dimensional fat-suppressed T1-weighted gradient-echo images before and after injection of an MRI contrast agent, T2-weighted single-shot fast spin-echo (SSFSE) images, and diffusion-weighted (DW) images obtained with the AIR coil were compared with corresponding images obtained with the conventional coil. One radiologist measured signal-to-noise ratios (SNRs), while two other radiologists used a 3-point scale to independently assess subjective image noise, artifacts, signal uniformity, and overall image quality. RESULTS: SNRs for the AIR coil were significantly higher than those for the conventional coil (P <.05). Subjective image noise for the AIR coil on pre- and postcontrast T1-weighted and DW images was lower than for the conventional coil for both readers (P <.05). Overall image quality on pre- and postcontrast T1-weighted and DW images for the AIR coil was better than that for the conventional coil for at least one reader (P <.05). CONCLUSIONS: In comparison with the conventional coil, AIR coil improved SNR and image quality of liver MR imaging.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Tecnologia
14.
Sci Rep ; 12(1): 12176, 2022 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-35842451

RESUMO

Virtual thin-slice (VTS) technique is a generative adversarial network-based algorithm that can generate virtual 1-mm-thick CT images from images of 3-10-mm thickness. We evaluated the performance of VTS technique for assessment of the spine. VTS was applied to 4-mm-thick CT images of 73 patients, and the visibility of intervertebral spaces was evaluated on the 4-mm-thick and VTS images. The heights of vertebrae measured on sagittal images reconstructed from the 4-mm-thick images and VTS images were compared with those measured on images reconstructed from 1-mm-thick images. Diagnostic performance for the detection of compression fractures was also compared. The intervertebral spaces were significantly more visible on the VTS images than on the 4-mm-thick images (P < 0.001). The absolute value of the measured difference in mean vertebral height between the VTS and 1-mm-thick images was smaller than that between the 4-mm-thick and 1-mm-thick images (P < 0.01-0.54). The diagnostic performance of the VTS images for detecting compression fracture was significantly lower than that of the 4-mm-thick images for one reader (P = 0.02). VTS technique enabled the identification of each vertebral body, and enabled accurate measurement of vertebral height. However, this technique is not suitable for diagnosing compression fractures.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Algoritmos , Fraturas por Compressão/diagnóstico por imagem , Humanos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
15.
Front Oncol ; 12: 1026608, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36620558

RESUMO

Purpose: PET with L-4-borono-2-[18F] fluoro-phenylalanine (FBPA) was reported to be useful to differentiate malignant tumors and inflammation. Although immunotherapy with immune checkpoint inhibitors (ICIs) has been applied to cancer treatment recently, FDG PET may not be suitable to determine the effect of ICIs because of false-positive findings caused by treatment-related inflammation. In this study, we aimed to demonstrate that FBPA PET allowed detection of the early response of anti-PD-1 immunotherapy in tumor-bearing mice, comparing the results with those of FDG PET. Materials and methods: Mice with B16F10 melanoma tumor xenografts were prepared. Anti-mouse PD-1 antibody or PBS was administered twice intraperitoneally to the tumor-bearing mice on Day 0 (3 days after inoculation) and Day 5 (treatment or control group ). PET/CT imaging was performed twice for each mouse on Day 0 before the anti-PD-1 antibody/PBS administration and on Day 7 using a micro-PET/CT scanner. FBPA and FDG PET/CT studies were conducted separately. SUVmax and the tumor to liver ratio (T/L ratio) were used as parameters exhibiting tumor activity. Tumor uptake volume (TUV) and metabolic tumor volume (MTV) were also calculated for FBPA and FDG, respectively. Changes between pre- and posttreatment SUVmax or T/L ratio were observed using the formula as follows: [(posttreatment parameter values/pretreatment values - 1) × 100] (%). Results: Tumors in TrG were smaller than those in CoG on Day 7. SUVmax and T/L ratio represented no differences between TrG and CoG in FBPA and FDG PET before treatment. FBPA PET on Day 7 demonstrated that SUVmax, T/L ratio, and TUV in TrG were statistically smaller than those in CoG. %T/L ratio and %SUVmax exhibited the same trend in FBPA PET. However, FDG PET on Day 7 revealed no differences in all parameters between TrG and CoG. T/L ratio and %SUVmax in TrG represented larger values than those in CoG without statistical significances. Conclusion: This study demonstrated that FBPA PET allowed detection of the early response of anti-PD-1 immunotherapy in B16F10 melanoma-bearing mice. FDG PET did not detect the response. Further studies are required to determine whether FBPA PET is useful in evaluating the treatment effect of ICIs in humans.

16.
J Clin Med ; 11(19)2022 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-36233521

RESUMO

Purpose: To compare the accuracy of liver fibrosis staging with MR elastography and of staging with extracellular volume fraction (fECV) analysis using contrast-enhanced CT. Methods: This retrospective study included 60 patients who underwent both MR elastography and contrast-enhanced CT before liver surgery between October 2013 and July 2020. Two radiologists independently measured liver stiffness of MR elastography and fECV of CT images. Accuracy for liver fibrosis staging was assessed using receiver operating characteristic (ROC) analysis. Correlations between liver stiffness or fECV and liver fibrosis were also evaluated by means of the Spearman rank correlation coefficient. Results: The areas under the ROC curves for MR elastography for each stage differentiation of ≥F1 (0.85, 0.82 for the two radiologists), ≥F2 (0.88, 0.89), ≥F3 (0.87, 0.86), and F4 (0.84, 0.83) were greater than those for fECV analysis with CT (0.64, p = 0.06, 0.69, p = 0.2; 0.62, p < 0.005, 0.63, p < 0.005; 0.62, p < 0.005, 0.62, p < 0.01; and 0.70, p = 0.08, 0.71, p = 0.2, respectively). The correlation coefficients between liver stiffness and liver fibrosis in A0 (0.67, 0.69 for the two radiologists), A1 (0.64, 0.66) and A2 group (0.58, 0.51) were significantly higher than those between fECV and liver fibrosis (0.28, 0.30; 0.27, 0.31; and 0.23, 0.07; p < 0.05 for all comparisons). Conclusion: MR elastography allows for more accurate liver fibrosis staging compared with fECV analysis with CT. In addition, MR elastography may be less affected than fECV analysis by the inflammatory condition.

17.
Eur J Radiol ; 156: 110522, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36113381

RESUMO

PURPOSE: This study aimed to assess the relationship between pancreatic fibrosis measured by the extracellular volume fraction (ECV) using contrast-enhanced computed tomography (CT) and the histologic pancreatic fibrosis fraction and investigate the relationship between pancreatic fibrosis and pancreatic cancer. METHOD: The study included 88 consecutive patients (48 males, 40 females; median age, 69 years; range, 17-89 years); 47 had pancreatic cancer, and 41 had other diseases. Fifty-two cases were evaluated pathologically for pancreatic fibrosis. The histologic pancreatic fibrosis fraction was quantified using image analysis software in nontumorous pancreatic tissue at the resection stump using 2-µm-thick Azan-stained slides. Two board-certified radiologists measured ECV in the pancreatic parenchyma at an estimated transection line. The correlation between histologic pancreatic fibrosis fraction and ECV was investigated, and whether the ECV value could be used as a biomarker for pancreatic cancer was investigated. RESULTS: The histologic pancreatic fibrosis fraction was significantly correlated with the ECV (r = 0.64, P < 0.01). Pancreatic fibrosis evaluated by ECV was higher in pancreatic cancer patients than in other patients (P < 0.01). On receiver-operating characteristic curve analysis, the ECV had good diagnostic accuracy for the development of pancreatic cancer (cut-off value 32.8%; sensitivity 61.0%, specificity 85.1%). ECV was identified on multivariate analysis as an independent risk factor for pancreatic cancer (odds ratio 1.16; P < 0.01). CONCLUSIONS: Extracellular volume fraction was strongly related to the histologic pancreatic fibrosis fraction, which was independently associated with pancreatic cancer. Thus, extracellular volume fraction is an imaging biomarker that reflects the progression of pancreatic fibrosis and may potentially help predict the development of pancreatic cancer, although further investigation will be needed.

18.
J Clin Med ; 10(19)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34640568

RESUMO

Background: Strong correlation has been reported between tissue water diffusivity and tissue elasticity in the liver. The purpose of this study is to explore the capability of diffusion-based virtual MR elastography (VMRE) in the characterization of liver tumors by extending beyond liver fibrosis assessments. Methods: Fifty-four patients (56 liver tumors: hepatocellular carcinoma (HCC), 31; metastases, 25) who underwent MRE, diffusion-weighted imaging (DWI) (b: 0, 800 s/mm2), and VMRE (b: 200, 1500 s/mm2) were enrolled. The MRE shear modulus (µMRE), apparent diffusion coefficient (ADC), and shifted ADC (sADC) were obtained. Virtual stiffness (µdiff) was estimated from the relationship between µMRE and sADC. A linear discriminant analysis combining VMRE and MRE to classify HCC and metastases was performed in a training cohort (thirty-two patients) to estimate a classifier (C), and evaluate its accuracy in a testing cohort (twenty-two patients). Pearson's correlations between µMRE, sADC, and ADC were evaluated. In addition to the discriminant analysis, a receiver operating characteristic (ROC) curve was used to assess the discrimination capability between HCC and metastases. Results: The correlations between µMRE and sADC were significant for liver, HCC, and metastases (r = 0.91, 0.68, 0.71; all p < 0.05). Those between µMRE and ADC were weaker and significant only for metastases (r = 0.17, 0.20, 0.55). µdiff values were not significantly different between HCC and metastases (p = 0.56). Areas under the curves (AUC) to differentiate HCC from metastases were as follows: VMRE, 0.46; MRE alone, 0.89; MRE + VMRE, 0.96. The classifier C also provided better performance than MRE alone, in terms of sensitivity (100 vs. 93.5%, respectively) and specificity (92 vs. 76%, respectively, p = 0.046). Conclusions: The correlation between sADC and µMRE was strong both in the liver and in tumors. However, VMRE alone could not classify HCC and metastases. The combination of MRE and VMRE, however, allowed discriminant performance between HCC and metastases.

19.
Jpn J Radiol ; 39(9): 889-897, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33948788

RESUMO

PURPOSE: To evaluate the image quality and ability to delineate the small visceral arteries of high-resolution (HR) abdominal CT angiography (CTA) using an ultra-high-resolution computed tomography (UHR CT) scanner. MATERIALS AND METHODS: Thirty-seven patients were enrolled who underwent abdominal CTA using a UHR CT scanner. The images were reconstructed with a matrix of 1024 × 1024 and 0.25 mm thickness for HR CTA and with a matrix of 512 × 512 and 0.5 mm thickness for normal resolution (NR) CTA. Maximum CT value, image quality, and delineation of the small arteries were compared between HR CTA and NR CTA. RESULTS: HR CTA showed significantly higher maximum CT value, higher image quality, and better delineation of the small arteries than did NR CTA (P < .005). CONCLUSION: HR CTA using a UHR CT scanner showed higher image quality than NR CTA and enhanced the delineation of visceral arteries.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Abdome , Angiografia , Artérias , Humanos
20.
Medicine (Baltimore) ; 100(20): e26109, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34011134

RESUMO

ABSTRACT: Understanding intratumoral fat in hepatocellular carcinoma (HCC) is clinically important to elucidate prognosis. We sought to quantify HCC and liver fat with a multimaterial decomposition (MMD) algorithm with rapid kilovoltage-switching dual-energy computed tomography (DECT) relative to chemical-shift magnetic resonance imaging (CSI).In this retrospective study, 40 consecutive patients with HCC underwent non-contrast-enhanced (non-CE) and four-phases contrast-enhanced (four-CE) DECT (80 and 140 kVp) and abdominal MR imaging (including CSI) between April 2011 and December 2012. Fat volume fraction (FVFDECT) maps were generated by MMD algorithm to quantify HCC and liver fat. Fat fraction measured by CSI (FFCSI) was determined for HCC and liver on dual-echo sequence using 1.5- or 3-Tesla MR systems. The correlation between FVFDECT and FFCSI was evaluated using Pearson correlation test, while non-CE FVFDECT and four-CE FVFDECT were compared by one-way ANOVA and Bland-Altman analysis.Forty patients (mean age, 70.1 years ± 7.8; 25 males) were evaluated. FVFDECT and FFCSI exhibited weak to moderate correlations for HCC in non-CE and four-CE except in equilibrium phase (r = 0.42, 0.44, 0.35, and 0.33; all P < .05), and very strong correlations for liver in all phases (r = 0.86, 0.83, 0.85, 0.87, and 0.84; all P < .05). Those correlation coefficients were significantly higher for liver for each phase (all P < .05). FVFDECT did not differ significantly across scan phases regarding HCC or liver (P = .076 and 0.56). Bland-Altman analysis showed fixed bias in all phases between non- and four-CE FVFDECT in HCC and liver.As compared with liver, correlations between FVF measured by DECT-based MMD and FF measured by CSI were weak in HCC in all phases. FVF is reproducible across all scan phases in HCC and liver. The MMD algorithm requires modification for HCC fat quantification given the heterogeneous components of HCC.


Assuntos
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Fígado Gorduroso/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA