Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Reprod Dev ; 64(2): 109-115, 2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29311520

RESUMO

This study aimed to clarify the feasibility of a novel timed artificial insemination (TAI) protocol using ultrasonography, and to determine the associations between the ovarian component and fertility. In Experiment 1, 272 Japanese Black cows with a corpus luteum (CL) ≥ 18 mm in diameter were divided randomly into either the TRT group (134 cows that were administered gonadotropin-releasing hormone [GnRH] 56 h [day 2] after prostaglandin F2α [PGF] administration [day 0], followed by TAI 16-20 h later) or the CN-1 group (138 cows that were administered PGF followed by AI after estrus detection). In addition, the CN-2 group was designated for 306 cows given PGF and inseminated after estrus detection in the past two years at the same farms. In Experiment 2, 38 cows had the same treatment as the TRT group, and the sizes of follicles and CL were video-recorded on days 0 and 2. In Experiment 1, the AI and ovulation synchronization rates were higher in the TRT group than those in the CN-1 group (100 vs. 87.0% and 89.2 vs. 33.3%, respectively) (P < 0.01). The pregnancy rate in the TRT group (60.4%) was higher than that in the CN-2 group (45.1%) (P < 0.05). In Experiment 2, cows with a larger CL diameter and greater CL volume on day 0 had a higher pregnancy outcome (P < 0.05). In conclusion, this protocol was effective for improving pregnancy rates in beef herds, and fertility was associated with the CL size at the time of PGF administration.


Assuntos
Corpo Lúteo/diagnóstico por imagem , Detecção do Estro , Inseminação Artificial/veterinária , Ultrassonografia/veterinária , Animais , Animais Endogâmicos , Bovinos , Corpo Lúteo/efeitos dos fármacos , Dinoprosta/farmacologia , Sincronização do Estro , Estudos de Viabilidade , Feminino , Fármacos para a Fertilidade Feminina/farmacologia , Hormônio Liberador de Gonadotropina/farmacologia , Japão , Tamanho do Órgão/efeitos dos fármacos , Folículo Ovariano/diagnóstico por imagem , Folículo Ovariano/efeitos dos fármacos , Gravidez , Progesterona/sangue , Distribuição Aleatória , Fatores de Tempo
2.
J Vet Med Sci ; 83(5): 767-774, 2021 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-33775988

RESUMO

Point-of-care (POC) devices that veterinary practitioners can use to easily and rapidly measure blood ionized calcium (iCa) levels in cows immediately after withdrawing a blood sample on the dairy farm are needed. Aims of present studies was to compare the commercially available ion-selective electrode handheld iCa meter (bovine blood iCa checker) with the benchtop blood gas analyzer GEM premier 3500 and handheld analyzer i-STAT 1. Sixty-two paired-point whole blood samples were obtained from three cows with hypocalcemia experimentally induced by Na2-EDTA infusion. Whole blood samples were also obtained from the 36 cows kept on a farm in field conditions. The results using the bovine blood iCa checker correlated with those using the GEM premier 3500 and i-STAT 1. Bovine blood iCa checker was "compatible" with the GEM premier 3500 and i-STAT 1 because the frequency of differences between the measurements within ± 20% of the mean were 100% (65/65, >75%) and 90.8% (59/65, >75%), respectively. In the field trial, the blood iCa concentration measured by the bovine blood Ca checker was significantly positively correlated with that measured by the i-STAT 1 portable analyzer. Bovine blood iCa checker was "compatible" with the i-STAT 1 because the frequency of differences between the measurements within ± 20% of the mean was 100% (36/36, >75%). Results from these findings, the bovine blood iCa checker may be applied as a simplified system to measure the iCa concentration in bovine whole blood.


Assuntos
Doenças dos Bovinos , Hipocalcemia , Animais , Gasometria/veterinária , Cálcio , Bovinos , Feminino , Testes Hematológicos/veterinária , Hipocalcemia/diagnóstico , Hipocalcemia/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA