Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Orthopedics ; 45(6): 345-352, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35947454

RESUMO

Previous studies have defined risk factors for development of venous thromboembolisms (VTEs) among patients with lower extremity orthopedic trauma. Limited data exist on this risk after upper extremity orthopedic trauma. A total of 269,137 incidents of upper extremity orthopedic trauma (fractures of the clavicle, scapula, humerus, elbow, or lower arm) were identified in the State Inpatient Database for 4 states included in the analysis (California, Florida, New York, and Washington) from 2006 to 2014. These patients were split into 2 cohorts, a derivation cohort (California and New York) and a validation cohort (Florida and Washington). Univariate and multivariate logistic regression analyses of risk factors for VTE within 90 days of discharge in the derivation group were used to develop the Thromboembolic Risk after Upper Extremity Trauma (TRUE-T) scale. Linear regression was used to determine fit of the TRUE-T scale to the 2 cohorts. We found that 2.61% of patients in the derivation cohort and 2.72% of patients in the validation cohort had a VTE within 90 days of discharge. Risk factors associated with increased rates of VTE were age older than 40 years, Medicare payer, anemia, chronic lung disease, coagulopathy, heart failure, malignancy, obesity, renal failure, head injury, chest injury, abdominal injury, rib fracture, humerus fracture, elbow fracture, and closed reduction. Application of the TRUE-T scale to the validation cohort showed an R2 value of 0.88. The patient factors, concomitant injuries, and fracture treatment modalities included in the TRUE-T scale can be used to identify patients at increased risk for VTE after upper extremity orthopedic trauma. [Orthopedics. 2022;45(6):345-352.].


Assuntos
Fraturas Ósseas , Traumatismos da Perna , Tromboembolia Venosa , Trombose Venosa , Humanos , Idoso , Estados Unidos , Adulto , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/epidemiologia , Tromboembolia Venosa/etiologia , Medicare , Fraturas Ósseas/complicações , Traumatismos da Perna/complicações , Extremidade Superior
2.
J Orthop Trauma ; 36(7): e265-e270, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34924510

RESUMO

OBJECTIVES: To compare the interobserver and intraobserver reliability of traction radiographs with 2-dimensional computed tomography (2D CT) in distal humerus fracture classification and characterization. DESIGN: Randomized controlled radiographic review of retrospectively collected data. SETTING: Academic Level 1 trauma center. PATIENTS/PARTICIPANTS: Skeletally mature patients with intra-articular distal humerus fractures with both traction radiographs and CT scans were reviewed by 11 orthopaedists from different subspecialties and training levels. INTERVENTION: The intervention involved traction radiographs and 2D CT. MAIN OUTCOME MEASUREMENTS: The main outcome measurements included interobserver and intraobserver reliability of fracture classification by the OTA/AO and Jupiter-Mehne and determination of key fracture characteristics. RESULTS: For the OTA/AO and Jupiter-Mehne classifications, we found a moderate intraobserver agreement with both 2D CT and traction radiographs (κ = 0.70-0.75). When compared with traction radiographs, 2D CT improved the interobserver reliability of the OTA/AO classification from fair to moderate (κ = 0.3 to κ = 0.42) and the identification of a coronal fracture from slight to fair (κ = 0.2 to κ = 0.34), which was more pronounced in a subgroup analysis of less-experienced surgeons. When compared with 2D CT, traction radiographs improved the intraobserver reliability of detecting stable affected articular fragments from fair to substantial (κ = 0.4 to κ = 0.67). CONCLUSIONS: Traction radiographs provide similar diagnostic characteristics as 2D CT in distal humerus fractures. For less-experienced surgeons, 2D CT may improve the identification of coronal fracture lines and articular comminution.


Assuntos
Fraturas Ósseas , Tração , Humanos , Úmero , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Injury ; 52(4): 686-691, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33246644

RESUMO

OBJECTIVES: The purpose of this study was to compare the biomechanical attributes of patella fracture fixation with either anterior plating utilizing two parallel, longitudinal 2.0 mm plates technique versus a cannulated screw tension band technique. METHODS: Five matched pairs (ten specimens) of fresh frozen cadavers were utilized. A transverse patella fracture (OTA 34C1.1) was fixed using either two 4.0 mm cannulated screw anterior tension band (CATB) or with two 2.0 mm stainless steel non-locking plates along the anterior cortex secured with 2.4 mm cortical screws traversing the fracture site. Specimens underwent 1000 cycles of simulated active knee range of motion before load to failure destructive testing. RESULTS: During cyclic loading there were no failures in the plate fixation group, and 2 out of 5 specimens catastrophically failed in the CATB group (p = 0.22). Average fracture displacement at the end of fatigue testing was 0.96 mm in the plate fixation group and 2.72 mm in the CATB group (p = 0.18). The specimens that withstood cyclic testing underwent a destructive load. Mean load to failure for the plate fixation specimens was 1286 N, which was not significantly different from the CATB group mean of 1175 N (p = 0.48). The mechanism of failure in the plate fixation cohort was uniformly via a secondary vertical patella fracture around the plates in all five specimens. In the CATB group, the mechanism of failure was via wire elongation and backing out of the screws. CONCLUSIONS: Patella fixation with anterior plating technique statistically performed equivalent to cannulated screw anterior tension band in ultimate load to failure strength and fatigue endurance under cyclical loading. No failures were observed cyclic simulated active range of motion in the anterior plate group. There was a trend towards improved fatigue endurance in the plate fixation group, however this did not reach statistical significance. We believe plate fixation technique represents a low-profile implant option for treatment of transverse patella fractures, which may allow for early active range of motion, and these data support biomechanical equivalency to standard of care.


Assuntos
Fraturas Ósseas , Patela , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixação de Fratura , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos , Patela/cirurgia
4.
Arthroplast Today ; 2(3): 133-136, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28326415

RESUMO

In medicine today, there is a trend toward increasing transparency. Higher quality and better value are being sought, and one of the methods being used is publicly reported health care outcomes. However, there is a problem that comes from our loss of anonymity. Physicians who are being individually watched have to choose between doing what is best for the patient and doing what would look good when it is publicly reported. Often this might mean choosing not to treat a particularly sick patient who is unlikely to have a good outcome. Adjusting outcomes to account for risk factors should be a way to prevent this effect, but these methods need to be studied more. The current performance measures being released are based on administrative claims data, and to date, much of that information is not properly risk adjusted. To ensure that the increasing transparency reveals an accurate picture, it is critical that the complexity of care provided by surgeons be carefully documented. Therefore, we propose accurate coding of patients' comorbidities during hospitalization for total knee arthroplasty and total hip arthroplasty, and we have included a chart detailing our recommendations of the specific diagnostic codes that are most important.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA