Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
AAPS PharmSciTech ; 25(1): 24, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267745

RESUMO

Previous work demonstrated that roller compaction of a 40%w/w theophylline-loaded formulation resulted in granulate consisting of un-compacted fractions which were shown to constitute between 34 and 48%v/v of the granulate dependent on processing conditions. The active pharmaceutical ingredient (API) primary particle size within the un-compacted fraction was also shown to have undergone notable size reduction. The aim of the current work was to test the hypothesis that the observations may be more indicative of the relative compactability of the API due to the formulation being above the percolation threshold. This was done by assessing the impact of varied API loads in the formulation on the non-granulated fraction of the final granulate and the extent of attrition of API particles within the non-granulated fraction. The influence of processing conditions for all formulations was also investigated. The results verify that the observations, both of this study and the previous work, are not a consequence of exceeding the percolation threshold. The volume of un-compacted material within the granulate samples was observed to range between 34.7 and 65.5% depending on the API load and roll pressure, whilst the API attrition was equivalent across all conditions.


Assuntos
Teofilina , Tamanho da Partícula
2.
AAPS PharmSciTech ; 23(8): 286, 2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261755

RESUMO

Computational modeling, machine learning, and statistical data analysis are increasingly utilized to mitigate chemistry, manufacturing, and control failures related to particle properties in solid dosage form manufacture. Advances in particle characterization techniques and computational approaches provide unprecedented opportunities to explore relationships between particle morphology and drug product manufacturability. Achieving this, however, has numerous challenges such as producing and appropriately curating robust particle size and shape data. Addressing these challenges requires a harmonized strategy from material sampling practices, characterization technique selection, and data curation to provide data sets which are informative on material properties. Herein, common sources of error in particle characterization and data compression are reviewed, and a proposal for providing robust particle morphology (size and shape) data to support modeling efforts, approaches for data curation, and the outlook for modeling particle properties are discussed.


Assuntos
Curadoria de Dados , Indústria Farmacêutica , Pós , Tamanho da Partícula , Simulação por Computador
4.
AAPS PharmSciTech ; 21(6): 218, 2020 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-32743765

RESUMO

The attrition of drug particles during the process of dry granulation, which may (or may not) be incorporated into granules, could be an important factor in determining the subsequent performance of that granulation, including key factors such as sticking to punches and bio-performance of the dosage form. It has previously been demonstrated that such attrition occurs in one common dry granulation process train; however, the fate of these comminuted particles in granules was not determined. An understanding of the phenomena of attrition and incorporation into granule will improve our ability to understand the performance of granulated systems, ultimately leading to an improvement in our ability to optimize and model the process. Unique feeding mechanisms, geometry, and milling systems of roller compaction equipment mean that attrition could be more or less substantial for any given equipment train. In this work, we examined attrition of API particles and their incorporation into granule in an equipment train from Gerteis, a commonly used equipment train for dry granulation. The results demonstrate that comminuted drug particles can exist free in post-milling blends of roller compaction equipment trains. This information can help better understand the performance of the granulations, and be incorporated into mechanistic models to optimize such processes.


Assuntos
Composição de Medicamentos/métodos , Tecnologia Farmacêutica/métodos , Tamanho da Partícula , Pós , Comprimidos
5.
AAPS PharmSciTech ; 19(8): 3462-3480, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30411240

RESUMO

The impact of pharmaceutical materials properties on drug product quality and manufacturability is well recognised by the industry. An ongoing effort across industry and academia, the Manufacturing Classification System consortium, aims to gather the existing body of knowledge in a common framework to provide guidance on selection of appropriate manufacturing technologies for a given drug and/or guide optimization of the physical properties of the drug to facilitate manufacturing requirements for a given processing route. Simultaneously, material scientists endeavour to develop characterisation methods such as size, shape, surface area, density, flow and compactibility that enable a stronger understanding of materials powder properties. These properties are routinely tested drug product development and advances in instrumentation and computing power have enabled novel characterisation methods which generate larger, more complex data sets leading to a better understanding of the materials. These methods have specific requirements in terms of data management and analysis. An appropriate data management strategy eliminates time-consuming data collation steps and enables access to data collected for multiple methods and materials simultaneously. Methods ideally suited to extract information from large, complex data sets such as multivariate projection methods allow simpler representation of the variability contained within the data and easier interpretation of the key information it contains. In this review, an overview of the current knowledge and challenges introduced by modern pharmaceutical material characterisation methods is provided. Two case studies illustrate how the incorporation of multivariate analysis into the material sciences workflow facilitates a better understanding of materials.


Assuntos
Indústria Farmacêutica , Tecnologia Farmacêutica , Desenvolvimento de Medicamentos , Pós
6.
Pharm Dev Technol ; 22(7): 904-909, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27344924

RESUMO

The aim of this study was to determine the location of attrition of formulated API particles within a powder feed system using a Morphologi G3-ID system, an image analyzer with integrated Raman capability enabling classification of particles with respect to their chemistry, to extract the API size distribution from the blended sample. The study also aimed to investigate the impact of other process variables, such as feed screw speed, on the extent of attrition observed. The study demonstrated that attrition occurs in two zones of the powder feed system, at the bottom of the hopper at the interface with the feed screw, and also within the feed screw itself. In the situation of the attrition at the bottom of the hopper variations in the hopper fill level were not observed to change the extent of attrition observed. Variation of the feed screw speed was observed to affect the extent of API attrition, with the particle size within the formulation observed to decrease with increasing speed. The findings highlight that an understanding of the impact of unit processes, and variations in the associated processing conditions, is vital in order to fully understand the behavior and performance of pharmaceutical dosage forms.


Assuntos
Química Farmacêutica , Tecnologia Farmacêutica , Tamanho da Partícula , Pós
7.
Pharm Res ; 32(5): 1804-16, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25515491

RESUMO

PURPOSE: To understand the mechanisms of secondary drying of spray-dried dispersion (SDD) drug product and establish a model to describe the fate of organic solvents in such a product. METHODS: The experimental approach includes characterization of the SDD particles, drying studies of SDD using an integrated weighing balance and mass spectrometer, and the subsequent generation of the drying curve. The theoretical approach includes the establishment of a Fickian diffusion model. RESULTS: The kinetics of solvent removal during secondary drying from the lab scale to a bench scale follows Fickian diffusion model. Excellent agreement is obtained between the experimental data and the prediction from the modeling. CONCLUSIONS: The diffusion process is dependent upon temperature. The key to a successful scale up of the secondary drying is to control the drying temperature. The fate of primary solvents including methanol and acetone, and their potential impurity such as benzene can be described by the Fickian diffusion model. A mathematical relationship based upon the ratio of diffusion coefficient was established to predict the benzene concentration from the fate of the primary solvent during the secondary drying process.


Assuntos
Acetona/isolamento & purificação , Dessecação/métodos , Metanol/isolamento & purificação , Solventes/isolamento & purificação , Difusão , Estabilidade de Medicamentos , Cinética , Modelos Químicos , Temperatura
8.
AAPS PharmSciTech ; 16(1): 165-70, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25233802

RESUMO

Bulk density can be a key indicator of performance, and may influence choice of formulation route of materials in pharmaceutical development. During early development, the cost of API's can be expensive and the availability of material for powder property analysis is limited. The aim of this work was to investigate a suitable small-scale, low material requirement, bulk density test which would provide comparable data to the recommended large volume USP test. Materials with a range of morphological characteristics typically seen in the pharmaceutical industry were assessed to ensure that methods were suitably robust. It was found that the USP II "low volume" test does not give equivalent results to other tests in the USP, across the range of materials. An alternative test based on the FT4 powder rheometer at a scale of 25 mL gave results equivalent to the large volume USP I standard test. The use of smaller 10-mL methods was also found to give acceptable results for materials that were considered well-behaved but were more variable with difficult to handle materials with low bulk density.


Assuntos
Densitometria/normas , Teste de Materiais/normas , Tamanho da Partícula , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Tecnologia Farmacêutica/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
10.
Pharm Dev Technol ; 18(1): 246-56, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22813432

RESUMO

A novel use of external lubrication has been investigated in which magnesium stearate was applied directly to the roll surface during roller compaction. A scalable parameter; travelling roll distance per shot (D(pS)), has been defined which ensures that an equal amount of magnesium stearate is applied to the roll surface per rotation at any roll speed. It was found that a formulation containing 20% w/w of either the API Pravastatin or Ibipinabant required a smaller D(pS) than a placebo formulation in order to prevent roll adherence. The inherent adhesiveness, and hence the required amount of external magnesium stearate to prevent roll adhesion, will depend on the material properties of the formulation. The amount of magnesium stearate transferred from the roll surface to the ribbon was measured using inductively coupled plasma optical emission spectroscopy and was found to be less than 0.01% w/w. This is a significant reduction in magnesium stearate compared to the normal manufacturing procedure of blending 0.25-2.0% w/w within the formulation.The advantage of external lubrication during roller compaction is the significant reduction in magnesium stearate from the formulation which could lead to the production of tablets with superior mechanical properties and faster dissolution times.


Assuntos
Composição de Medicamentos/métodos , Excipientes/química , Lubrificantes/química , Ácidos Esteáricos/química , Adesividade , Amidinas/química , Composição de Medicamentos/instrumentação , Pravastatina/química , Pirazóis/química , Solubilidade , Espectrofotometria Atômica/métodos , Comprimidos , Fatores de Tempo
11.
Int J Pharm ; 635: 122743, 2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-36804520

RESUMO

The aim of this work was to develop approaches to utilize whole particle distributions for both particle size and particle shape parameters to map the full range of particle properties in a curated dataset. It is hoped that such an approach may enable a more complete understanding of the particle landscape as a step towards improving the link between particle properties and processing behaviour. A 1-dimensional principal component analysis (PCA) approach was applied to create a 'morphological distribution landscape'. A dataset of imaged APIs, intermediates and excipients encompassing particle size, particle shape (elongation, length and width) and distribution shape was curated between 2008 and 2022. The curated dataset encompassed over 200 different materials, which included over 150 different APIs, and approximately 3500 unique samples. For the purposes of the current work, only API samples were included. The morphological landscape enables differentiation of materials of equivalent size but varying shape and vice versa. It is hoped that this type of approach can be utilised to better understand the influence of particle properties on pharmaceutical processing behaviour and thereby enable scientists to leverage historical knowledge to highlight and mitigate risks associated to materials of similar morphological nature.


Assuntos
Tamanho da Partícula
12.
Crit Rev Toxicol ; 42(7): 549-98, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22656672

RESUMO

A recent review concluded that the evidence from epidemiology studies was indeterminate and that additional studies were required to support the diesel exhaust-lung cancer hypothesis. This updated review includes seven recent studies. Two population-based studies concluded that significant exposure-response (E-R) trends between cumulative diesel exhaust and lung cancer were unlikely to be entirely explained by bias or confounding. Those studies have quality data on life-style risk factors, but do not allow definitive conclusions because of inconsistent E-R trends, qualitative exposure estimates and exposure misclassification (insufficient latency based on job title), and selection bias from low participation rates. Non-definitive results are consistent with the larger body of population studies. An NCI/NIOSH cohort mortality and nested case-control study of non-metal miners have some surrogate-based quantitative diesel exposure estimates (including highest exposure measured as respirable elemental carbon (REC) in the workplace) and smoking histories. The authors concluded that diesel exhaust may cause lung cancer. Nonetheless, the results are non-definitive because the conclusions are based on E-R patterns where high exposures were deleted to achieve significant results, where a posteriori adjustments were made to augment results, and where inappropriate adjustments were made for the "negative confounding" effects of smoking even though current smoking was not associated with diesel exposure and therefore could not be a confounder. Three cohort studies of bus drivers and truck drivers are in effect air pollution studies without estimates of diesel exhaust exposure and so are not sufficient for assessing the lung cancer-diesel exhaust hypothesis. Results from all occupational cohort studies with quantitative estimates of exposure have limitations, including weak and inconsistent E-R associations that could be explained by bias, confounding or chance, exposure misclassification, and often inadequate latency. In sum, the weight of evidence is considered inadequate to confirm the diesel-lung cancer hypothesis.


Assuntos
Poluentes Ocupacionais do Ar/toxicidade , Neoplasias Pulmonares/epidemiologia , Exposição Ocupacional/efeitos adversos , Emissões de Veículos/toxicidade , Monóxido de Carbono/toxicidade , Monitoramento Ambiental/métodos , Estudos Epidemiológicos , Humanos , Neoplasias Pulmonares/etiologia , Neoplasias Pulmonares/fisiopatologia , Medição de Risco , Fatores de Risco
13.
Drug Dev Ind Pharm ; 38(1): 111-22, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21810064

RESUMO

A systematic evaluation on the effect of magnesium stearate on the transmission of a placebo formulation from the hopper to the rolls during screw fed roller compaction has been carried out. It is demonstrated that, for a system with two 'knurled' rollers, addition of 0.5% w/w magnesium stearate can lead to a significant increase in ribbon mass throughput, with a consequential increase in roll gap, compared to an unlubricated formulation (manufactured at equivalent process conditions). However, this effect is reduced if one of the rollers is smooth. Roller compaction of a lubricated formulation using two smooth rollers was found to be ineffective due to a reduction in friction at the powder/roll interface, i.e. powder was not drawn through the rollers leading to a blockage in the feeding system. An increase in ribbon mass throughput could also be achieved if the equipment surfaces were pre-lubricated. However this increase was found to be temporary suggesting that the residual magnesium stearate layer was removed from the equipment surfaces. Powder sticking to the equipment surfaces, which is common during pharmaceutical manufacturing, was prevented if magnesium stearate was present either in the blend, or at the roll surface. It is further demonstrated that the influence of the hopper stirrer, which is primarily used to prevent bridge formation in the hopper and help draw powder more evenly into the auger chamber, can lead to further mixing of the formulation, and could therefore affect a change in the lubricity of the carefully blended input material.


Assuntos
Composição de Medicamentos/instrumentação , Preparações Farmacêuticas/química , Pós/química , Ácidos Esteáricos/química , Tecnologia Farmacêutica/instrumentação , Celulose/química , Química Farmacêutica/métodos , Força Compressiva , Composição de Medicamentos/métodos , Excipientes/química , Lactose/química , Lubrificantes/química , Lubrificação/métodos , Tamanho da Partícula , Comprimidos/química , Tecnologia Farmacêutica/métodos
14.
Crit Rev Toxicol ; 41(5): 404-65, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21548755

RESUMO

IARC (2009; Metals, Particles and Fibres. IARC Monographs on the Evaluaton of Carcinogenic Risks to Humans. Volume 100C. Lyon, France: IARC) concluded that crystalline silica in occupational settings is a lung carcinogen. This conclusion is based primarily on studies with exposure-response (E-R) analyses and a pooled analysis of 10 major studies with about 1000 lung cancer cases. The purpose of this review is to critically assess this cancer classification based on E-R analyses in 18 studies from eight countries with about 2000 lung cancer cases and the same database used by IARC (2009) . The most appropriate exposure-response analysis is selected from latest study with least effect from bias, confounding, and presented graphically to assist individual assessment of the weight of evidence. Strength of association is consistently weak in the majority of studies. At the highest exposure level the mean relative risk (RR) is 1.5; four studies have strong associations (RRs > 2), three have moderate strong associations (RRs 1.5-2.0), six have weak-negligible associations (RRs 1-1.5), and five have no associations (RRs ≤1.0). Biological gradients were an inconsistent finding. Three studies had clear positive E-R trends; 3 had suggestive trends; and 12 had no E-R trends, 9 of which were flat or negative. There was a negative ER slope using RRs at the highest exposure of each study. Consistent findings of weak associations and lack of E-R trends does not support a causal association. Weight of evidence from occupational epidemiology does not support a causal association of lung cancer and silica exposure, which is contrary to the IARC conclusion using essentially the same data.


Assuntos
Poluentes Ocupacionais do Ar/toxicidade , Neoplasias Pulmonares/epidemiologia , Doenças Profissionais/epidemiologia , Exposição Ocupacional/estatística & dados numéricos , Dióxido de Silício/toxicidade , Adulto , Idoso , Carcinógenos/toxicidade , Cerâmica/toxicidade , China/epidemiologia , Cristalização , Relação Dose-Resposta a Droga , Alemanha/epidemiologia , Humanos , Itália/epidemiologia , Pessoa de Meia-Idade , Mineração/estatística & dados numéricos
15.
Pharm Dev Technol ; 16(5): 542-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20565228

RESUMO

Microcrystalline cellulose (MCC) is regarded as one of the most versatile tablet filler binders, finding a wide use in both granulation and direct compression operations. It has been shown that MCC particle populations consist of a mixture of 'rod like' primary particles, and agglomerates, and that the proportion of these primary particles and agglomerates differs within the different grades of materials, contributing to the different bulk properties of these materials. However, the proportion of primary particles and agglomerates has not previously been fully elucidated, and their contribution to the performance factors such as flow explained. In this paper we use a novel microscopy-based characterization technique to demonstrate that the proportion of 'agglomerates' in the series of MCC grades between PH101 and PH200 is, by number, very low, but sufficient to perturb a volume-based particle size method by significant amounts.


Assuntos
Celulose/química , Excipientes/química , Tamanho da Partícula , Tecnologia Farmacêutica/métodos , Celulose/ultraestrutura , Microscopia Eletrônica de Varredura , Pós/química , Comprimidos
16.
Pharm Dev Technol ; 15(3): 223-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22716462

RESUMO

This paper reports the use of an in-gap ribbon porosity calculation for the optimisation of roller compaction ribbon parameters in order to control downstream granule and tablet properties for a typical pharmaceutical formulation. The study demonstrates the effect of changes to roll speed and roll gap on the relative level of ribbon compaction for ribbons with equivalent in-gap porosities. It is demonstrated that in-gap ribbon porosity can be applied to enable optimization of the downstream granule processability characteristics for a typical pharmaceutical formulation and an understanding of the control space of a roller compaction process.


Assuntos
Amidinas/química , Química Farmacêutica/métodos , Força Compressiva , Pirazóis/química , Tamanho da Partícula , Porosidade , Comprimidos
17.
AAPS PharmSciTech ; 11(4): 1552-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21049309

RESUMO

This paper reports the batch-to-batch and vendor-to-vendor variations in the solid-state characteristics of multiple batches of lactose anhydrous from each of three vendors and the subsequent impact of these differences on processability and/or functionality.


Assuntos
Composição de Medicamentos , Lactose/química , Excipientes , Formaldeído , Testes de Dureza , Tamanho da Partícula , Propriedades de Superfície , Comprimidos
18.
Pharm Dev Technol ; 14(3): 299-304, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19519182

RESUMO

A study to establish if acoustic emission could be used to monitor a small scale (120 g batch size) high shear granulation process and predict the process end-point, is reported. The robustness of the prediction model was further assessed by changing process variables. It is demonstrated that the technique is capable of repeatedly producing granules with consistent physical characteristics, such as particle size distribution and bulk density, despite changes in batch size and liquid dose rates. It is demonstrated that the model was affected by changes in impeller speed such that it was unable to identify a process end-point.


Assuntos
Acústica , Composição de Medicamentos/métodos , Composição de Medicamentos/instrumentação , Desenho de Equipamento , Modelos Químicos , Tamanho da Partícula
19.
Pharm Dev Technol ; 2009 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-19624251

RESUMO

This paper reports the use of an in-gap ribbon porosity calculation for the optimisation of roller compaction ribbon parameters in order to control downstream granule and tablet properties for a typical pharmaceutical formulation. The study demonstrates the effect of changes to roll speed and roll gap on the relative level of ribbon compaction for ribbons with equivalent in-gap porosities. It is demonstrated that in-gap ribbon porosity can be applied to enable optimization of the downstream granule processability characteristics for a typical pharmaceutical formulation and an understanding of the control space of a roller compaction process.

20.
J Pharm Sci ; 108(11): 3515-3520, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31445006

RESUMO

Particle size analysis in the pharmaceutical industry has long been a source of debate regarding how best to define measurement accuracy; the degree to which the result of a measurement or calculation conforms to the true value. Defining a "true" value for the size of a particle can be challenging as the output of its measurement will differ because of variations in measurement approaches, instrumental differences and calculation methods. Consequently, for "real" particles, a universal "true" value does not exist and accuracy is therefore not a definable characteristic. Accordingly, precision is then a measure of the ability to reproducibly achieve a measurement of unknown relevance. This article proposes, in place of accuracy, a means to define the "appropriateness" of a measurement in line with the critical quality attributes (CQA) of the material being characterized. The decision as to whether the measurement is correct should involve a link to the CQA; that is, correlation should be demonstrated, without which the measured particle size cannot be defined as a critical material attribute. Correspondingly, methods should also be able to provide sufficient precision to demonstrate discrimination relating to variation in the CQA. The benefits and challenges of this approach are discussed.


Assuntos
Desenvolvimento de Medicamentos/métodos , Preparações Farmacêuticas/química , Bibliotecas de Moléculas Pequenas/química , Indústria Farmacêutica/métodos , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA