Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Ann Emerg Med ; 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38888531

RESUMO

STUDY OBJECTIVE: The real-world effectiveness and safety of a 0/1-hour accelerated protocol using high-sensitivity cardiac troponin (hs-cTn) to exclude myocardial infarction (MI) compared to routine care in the United States is uncertain. The objective was to compare a 0/1-hour accelerated protocol for evaluation of MI to a 0/3-hour standard care protocol. METHODS: The RACE-IT trial was a stepped-wedge, randomized trial across 9 emergency departments (EDs) that enrolled 32,609 patients evaluated for possible MI from July 2020 through April 2021. Patients undergoing high-sensitivity cardiac troponin I testing with concentrations less than or equal to 99th percentile were included. Patients who had MI excluded by the 0/1-hour protocol could be discharged from the ED. Patients in the standard care protocol had 0- and 3-hour troponin testing and application of a modified HEART score to be eligible for discharge. The primary endpoint was the proportion of patients discharged from the ED without 30-day death or MI. RESULTS: There were 13,505 and 19,104 patients evaluated in the standard care and accelerated protocol groups, respectively, of whom 19,152 (58.7%) were discharged directly from the ED. There was no significant difference in safe discharges between standard care and the accelerated protocol (59.5% vs 57.8%; adjusted odds ratio (aOR)=1.05, 95% confidence interval [CI] 0.95 to 1.16). At 30 days, there were 90 deaths or MIs with 38 (0.4%) in the standard care group and 52 (0.4%) in the accelerated protocol group (aOR=0.84, 95% CI 0.43 to 1.68). CONCLUSION: A 0/1-hour accelerated protocol using high-sensitivity cardiac troponin I did not lead to more safe ED discharges compared with standard care.

2.
Catheter Cardiovasc Interv ; 101(4): 756-763, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36748804

RESUMO

BACKGROUND: TandemHeart has been demonstrated to improve hemodynamic and metabolic complications in cardiogenic shock (CS). Contemporary outcomes have not been reported. OBJECTIVES: To evaluate the outcomes of the TandemHeart (LivaNova) in contemporary real-world use. METHODS: We analyzed baseline characteristics, hemodynamic changes, and outcomes of all patients treated with TandemHeart who were enrolled in the THEME registry, a multicenter, prospective, observational study. RESULTS: Between May 2015 and June 2019, 50 patients underwent implantation of the TandemHeart device. 22% of patients had TandemHeart implanted within 12 h, 32% within 24 h, and 52% within 48 h of CS diagnosis. Cardiac index (CI) was significantly improved 24 h after implantation (median change 1.0, interquartile range (IQR) (0.5-1.4 L/min/m2 ). In survivors, there was a significant improvement in CI (1.0, IQR (0.5-2.25 L/min/m2 ) and lactate clearance -2.3 (-5.0 to -0.7 mmol/L). The 30-day and 180-day survival were 74% (95% confidence interval: 60%-85%) and 66% (95% confidence interval: 51%-79%), respectively. Survival was similarly high in those in whom TandemHeart has been used as a bridge to surgery (85% 180-day survival). CONCLUSION: In a contemporary cohort of patients presenting in CS, the use of TandemHeart is associated with a 74% 30-day survival and a 66% 180-day survival.


Assuntos
Coração Auxiliar , Choque Cardiogênico , Humanos , Choque Cardiogênico/terapia , Estudos Prospectivos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Sistema de Registros
3.
Ann Emerg Med ; 72(6): 654-664, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30119942

RESUMO

STUDY OBJECTIVE: We determine how well a new Food and Drug Administration-approved single cardiac troponin T (cTnT) Generation 5 baseline measurement below the level of quantification (6 ng/L) and a novel study-derived baseline and 30-minute cTnT Generation 5 algorithm might adequately exclude acute myocardial infarction in patients with suspected acute coronary syndrome in a US emergency department (ED). METHODS: Patients presenting with any symptoms suspicious for acute coronary syndrome were enrolled at a single US ED. Baseline and 30-minute blood samples were obtained and cTnT Generation 5 levels were later batch analyzed in an independent core laboratory. Acute myocardial infarction diagnosis was adjudicated by a cardiologist and an emergency physician. RESULTS: Of the 569 study patients, 44 (7.7%) had an acute myocardial infarction diagnosis. One hundred sixty-four patients (28.8%) had a presentation cTnT Generation 5 level less than 6 ng/L, and none of these individuals had an acute myocardial infarction (negative predictive value of 100% [95% confidence interval 97.8% to 100.0%] and sensitivity of 100% [95% confidence interval 92.0% to 100.0%]). A baseline cTnT Generation 5 value of less than 8 ng/L and a 30-minute Δ of less than 3 ng/L were present in 221 patients (41.0%), and none had acute myocardial infarction (negative predictive value of 100% [95% confidence interval 98.3% to 100.0%] and sensitivity of 100% [95% confidence interval 92.0% to 100.0%]). CONCLUSION: In a single US ED, a single baseline cTnT Generation 5 measurement less than 6 mg/L and values at baseline less than 8 ng/L and a 30-minute Δ of less than 3 ng/L ruled out acute myocardial infarction in 28.8% and 41.0% of patients, respectively. Additional multicenter US studies evaluating these ultrarapid acute myocardial infarction rule-out guidelines are needed, especially to narrow the confidence intervals.


Assuntos
Biomarcadores/sangue , Infarto do Miocárdio/diagnóstico , Troponina T/sangue , Idoso , Algoritmos , Testes Diagnósticos de Rotina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/metabolismo , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Sensibilidade e Especificidade
4.
J Am Coll Emerg Physicians Open ; 5(2): e13140, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38567033

RESUMO

Objective: Protocols to evaluate for myocardial infarction (MI) using high-sensitivity cardiac troponin (hs-cTn) have the potential to drive costs upward due to the added sensitivity. We performed an economic evaluation of an accelerated protocol (AP) to evaluate for MI using hs-cTn to identify changes in costs of treatment and length of stay compared with conventional testing. Methods: We performed a planned secondary economic analysis of a large, cluster randomized trial across nine emergency departments (EDs) from July 2020 to April 2021. Patients were included if they were 18 years or older with clinical suspicion for MI. In the AP, patients could be discharged without further testing at 0 h if they had a hs-cTnI < 4 ng/L and at 1 h if the initial value were 4 ng/L and the 1-h value ≤7 ng/L. Patients in the standard of care (SC) protocol used conventional cTn testing at 0 and 3 h. The primary outcome was the total cost of treatment, and the secondary outcome was ED length of stay. Results: Among 32,450 included patients, an AP had no significant differences in cost (+$89, CI: -$714, $893 hospital cost, +$362, CI: -$414, $1138 health system cost) or ED length of stay (+46, CI: -28, 120 min) compared with the SC protocol. In lower acuity, free-standing EDs, patients under the AP experienced shorter length of stay (-37 min, CI: -62, 12 min) and reduced health system cost (-$112, CI: -$250, $25). Conclusion: Overall, the implementation of AP using hs-cTn does not result in higher costs.

5.
Acta Crystallogr Sect E Struct Rep Online ; 66(Pt 3): m318, 2010 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-21580257

RESUMO

In the title compound, [Cu(C(8)H(4)O(4))(C(16)H(20)N(4))(H(2)O)](n), square-pyramidally coordinated Cu(II) ions are linked into [Cu(H(2)O)(isophthalate)](n) coordination polymer chains by isophthalate dianions. These chains are connected into undulating [Cu(H(2)O)(isophthalate)(3-bpmp)](n) [3-bmp is bis-(3-pyridylmeth-yl)piperazine] layers by 3-bpmp tethering ligands. The pseudo three-dimensional structure of the title compound is fostered by inter-layer O-H⋯O hydrogen bonding between the aqua ligands and unligated isophthalate O atoms. The selected crystal was non-merohedrally twinned. Only reflections from the major twin component were used in the solution and refinement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA