RESUMO
BACKGROUND: Ulnar neuropathy at the elbow caused by heterotopic ossification (HO) is a rare condition. This retrospective study aims to report on 32 consecutive cases of ulnar nerve encasement caused by elbow HO and evaluate long-term outcomes of operative management and a standardized postoperative rehabilitation regimen. METHODS: A retrospective case series was conducted on 32 elbows (27 patients) that underwent operative management of bony ulnar nerve encasement. All procedures were performed in the inpatient setting at an Academic Level 1 Trauma Center from September 1999 to July 2021 by one of 3 fellowship-trained shoulder and elbow. Postoperatively, all patients received formal physical therapy, HO prophylaxis (30 received indomethacin, 2 received radiation), and a structured continuous passive motion machine regimen. Patient demographics, age, gender, type of injury, history of tobacco use, and medical comorbidities were obtained to include in the analysis. Long-term follow-up examinations were performed to evaluate elbow flexion-extension arc of motion, Mayo Elbow Performance Score, and visual analog scale pain scores. RESULTS: Thirty-two elbows with complete bony ulnar nerve encasement secondary to HO were identified (14 from burns, 15 from trauma, 3 closed head injuries). Following surgery, the mean flexion-extension arc of motion improved significantly, increasing from 21° to 100° at long-term follow-up (average 8.7 years, range 2-17 years), with statistically significant improvements in preoperative vs. long-term postoperative elbow extension (P < .001), flexion (P < .001), and total arc of motion (P < .001). There was a statistically significant improvement in pre- vs. postprocedure ulnar nerve function, as demonstrated by a decrease in average McGowan grade (1.2-0.7; P = .002). Additionally, 63% of patients with preoperative ulnar neuropathy symptoms (20/32) had either complete resolution or subjective improvement after surgery. The mean time from injury to surgery was 518 days (range 65-943 days). Age, gender, time to surgery, and medical comorbidities were not associated with outcomes. The complication rate was 9% (3/32). Patients had an average flexion-extension arc of motion of 97° and average Mayo Elbow Performance Score of 80 ("good") at long-term follow-up. CONCLUSIONS: The combination of operative management, postoperative HO prophylaxis, and a regimented rehabilitation program has proven to be a durable solution for treating and ensuring good long-term functional outcomes for patients with elbow HO and bony ulnar nerve encasement. This treatment approach leads to superior range of motion, improved or resolved ulnar neuropathy, and good to excellent long-term functional outcomes.
Assuntos
Articulação do Cotovelo , Ossificação Heterotópica , Neuropatias Ulnares , Humanos , Cotovelo/cirurgia , Nervo Ulnar/cirurgia , Estudos Retrospectivos , Articulação do Cotovelo/cirurgia , Neuropatias Ulnares/etiologia , Ossificação Heterotópica/etiologia , Ossificação Heterotópica/cirurgia , Ossificação Heterotópica/diagnóstico , Amplitude de Movimento Articular/fisiologia , Resultado do TratamentoRESUMO
BACKGROUND: Patients undergoing reverse shoulder arthroplasty (RTSA) have been noted on postoperative radiographs to have a curved bony overgrowth on the inferior glenoid neck. This study aims to investigate potential risk factors for and postoperative effects of these ossifications, here called glenoid hyperostosis (GHOST) lesions due to their location. METHODS: A retrospective review of patients undergoing reverse total shoulder arthroplasty between 2007 and 2020 at a single institution was performed. Predictors including gender, age, implant sizing, and preoperative diagnosis were examined using logistic regression analysis. Outcomes including readmission rate, revision rate, preoperative and postoperative range of motion, visual analog scale (VAS) pain scores, and American Shoulder and Elbow Surgeons (ASES) functional outcome scores were also analyzed using two-sample t-tests. RESULTS: Preoperative and postoperative radiographs of 170 primary reverse shoulder arthroplasty patients were assessed. 25.9% of RTSAs were identified to have a GHOST lesion. When adjusting for race, age, BMI, preoperative diagnosis, male patients were still associated with 2.28 odds of developing a GHOST lesion compared to female patients (95% CI: 1.08 - 4.86). Other elements such as age, race, BMI, laterality, preoperative diagnosis, implant manufacturer, and implant sizing demonstrated no statistically significant association to GHOST lesion presence. Postoperatively, GHOST lesion development was not associated with range of motion or ASES score. However, presence of GHOST lesions on radiographs was associated with increased pain scores for patients at 2 months (p = 0.034) and 12 months (p = 0.029) postoperatively. DISCUSSION: Inferior glenoid hyperostosis (GHOST) lesions is a common and potentially benign finding following reverse shoulder arthroplasty, with unclear etiology. Risk factors for GHOST lesions included male gender, while patient demographics, implant type or size, shoulder lateralization and distalization were not associated with lesion formation. Clinically, greater short-term VAS scores were seen in patients with GHOST lesions. However, there were no differences observed between the two groups in ASES scores or postoperative range of motion at later time points. Further research is needed to identify risk factors and assess the clinical implications of GHOST lesions.
RESUMO
BACKGROUND: Reverse shoulder arthroplasty (RSA) for fracture currently shares a single current procedural terminology (CPT) code with RSA for arthropathy despite potential differences in patient factors, procedural demands, postoperative care and needs, and overall hospital systems' resource utilization. We hypothesize that patients indicated for RSA for fracture will have greater medical complexity, require longer operative duration, have higher complication rates, demonstrate inferior functional outcomes, and require greater healthcare cost expenditures compared to a cohort undergoing RSA for rotator cuff arthropathy. METHODS: 383 RSAs were retrospectively reviewed from January 2011 to December 2020. Demographics, comorbidities, operative time, financial charge and cost data, length of stay (LOS), discharge disposition, and all-cause revisions were assessed. Visual analog scale (VAS) pain score and active range of motion (AROM) were evaluated at 2, 6, and 12 months postoperatively. RESULTS: 197 total RSA were included with 28 for fracture and 169 for arthropathy indications after exclusions. RSA operative time was longer for fractures with an average of 143.2±33.7 minutes compared to 108.2±33.9 minutes for arthropathy (p=0.001). Average cost per patient for RSA for proximal humerus fracture was $2,489 greater than cost for RSA for elective indications; however, no statistically significant difference was noted between average costs (p=0.126). LOS was longer for RSA for fracture compared to arthropathy with a mean of 4.0 ± 3.6 days versus 1.8 ± 2.3 days (p=0.004). The fracture group was 3.6 times more likely to be discharged to a skilled nursing facility or inpatient rehab (32% versus 9%, p=0.002). Early and late all-cause revisions were similar between groups. Differences in postoperative AROM for fracture versus arthropathy were significant for active forward flexion (aFF) at 2 months (95.5±36.7°, 117.0±32.3°) and 6 months (110.9±35.2°, 129.2±28.3°) (p=0.020) as well as active adducted external rotation (aER) at 6 months (20.0±20.9°, 33.1±12.3°) (p=0.007) and at 12 months (23.3±18.1°, 34.5±13.8°) (p=0.012). No difference in VAS pain scores were noted between fracture and arthropathy groups at any time point. DISCUSSION: RSA for fractures versus arthropathy have substantial differences in patient characteristics, surgical complexity, and hospital resource utilization. This is of importance given the currently available CPT code does not differentiate indications for RSA, especially if intending to accurately document surgical care delivered.
RESUMO
BACKGROUND: Alcohol consumption is a significant risk factor for both the occurrence and severity of rotator cuff tears. However, there is limited supporting evidence to suggest alcohol use is associated with suboptimal outcomes following operative repair of rotator cuff tears. Rat shoulders have been demonstrated as consistent and reliable models for studying rotator cuff disease. HYPOTHESIS/PURPOSE: Perioperative alcohol exposure will negatively impact biomechanical and histologic properties of surgically repaired rotator cuffs in rats. METHODS: Rats were randomized to receive a 20% ethanol or isocaloric control solution as their primary source of drinking water. A tenotomy of the supraspinatus tendon from bone was performed surgically and then immediately repaired with a transosseous technique. Following surgery, rats were continued on the same exposure solution until animals were humanely euthanized at 7, 14, or 21 days postoperatively. The surgically-repaired shoulders underwent biomechanical testing to assess load to failure and failure strain. Histological evaluation of tendon-to-bone healing was performed by a blinded pathologist using a qualitative grading system. Quantitative reverse transcription-polymerase chain reaction (qRT-PCR) on total RNA from tendon-to-bone interface tissue was performed to quantify the mRNA expression of Type I & III collagen, and transforming growth factor-beta 1 (TGF-B1) & 3 (TGF-B3) at the repair site. RESULTS: Biomechanical testing showed that repaired shoulder constructs in rats exposed to ethanol had significantly lower load to failure at 7 days postop relative to repairs in rats exposed to a control solution. No other biomechanical parameters or time points reached statistical significance. TGF-B3 mRNA expression was found in significantly higher quantities at the repair sites of rats exposed to ethanol at 7 days postop relative to control rat repair sites. No other time points or factors reached statistical significance. No significant differences were identified amongst time points or groups at the healing tendon-to-bone interface. CONCLUSION: Alcohol exposure significantly decreases biomechanical load to failure of rotator cuff repairs in the early postoperative period in rat models. In the later postoperative period, alcohol exposure was not associated with a decrease in biomechanical load to failure compared to controls. Additionally, rats exposed to ethanol have significantly higher TGF-B3 expression at repair sites on postoperative day 7. This data suggests that ethanol consumption does deleteriously affect rotator cuff and bone healing. Future study is needed to validate the clinical significance of these findings in humans.
RESUMO
BACKGROUND: Recurrent shoulder instability after reverse total shoulder arthroplasty (rTSA) presents a challenging clinical problem. A handful of cases have been reported describing stability achieved only after revision rTSA with cerclage augmentation. We describe an acromiohumeral cerclage technique, where the humeral component is fixed with a nonabsorbable, high-tensile suture tape looped through transosseous acromial drill tunnels as an augment to salvage shoulder stability. METHODS: All patients treated with acromiohumeral cerclage in rTSA for instability between November 1, 2015, and February 1, 2020, with minimum 1-year follow-up were included. Demographic information, baseline preoperative and postoperative range of motion at most recent follow-up, American Shoulder and Elbow Surgeons (ASES) shoulder scores, and visual analog scale (VAS) scores were recorded and compared. RESULTS: Ten patients, 4 female and 6 male, aged 64.3 ± 7.4 years (range, 53-77 years) with the mean postoperative follow-up of 23 months were included; 90% underwent surgery on the dominant side. Patients underwent an average of 2.1 ± 1.9 prior revisions (range, 0-7), over an average of 10.4 months (range, 0-72 months), before revision with suture cerclage augmentation was performed. All patients either had significant past shoulder history at other institutions and/or comorbidities that added significant complexity to their cases, with an average of 0.6 ± 0.9 (range, 0-3) prior other shoulder operations performed before their initial rTSA. The average decrease in VAS score among the 10 patients was 4.3 ± 2.7 (P < .05), ranging from 0 to 8 points. The average increase in ASES score was 51.3 ± 21 (P < .05), ranging from 13.3 to 69.9 points. The average increase in active forward elevation for 8 patients was 79° ± 39° (P = .0008), ranging from 40° to 160°. All patients have remained stable with well-positioned prostheses since their final operations with no recurrent dislocations or acromial complications. Two patients unable to travel for an office visit were contacted via phone and answered questions to obtain postoperative ASES and VAS scores. CONCLUSION: Acromiohumeral cerclage suture augmentation in revision rTSA may be a useful, simple surgical strategy to employ with other revision and augmentation techniques to treat cases of recurrent, chronic instability, particularly in the setting of multiple revisions.
Assuntos
Artroplastia do Ombro , Instabilidade Articular , Articulação do Ombro , Artroplastia do Ombro/efeitos adversos , Feminino , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Masculino , Amplitude de Movimento Articular , Reoperação/efeitos adversos , Estudos Retrospectivos , Articulação do Ombro/cirurgia , Resultado do TratamentoRESUMO
BACKGROUND: The study objective was to compare the reaming congruency of hand, power, and visual feedback axial alignment-guided (Marksman) reamers on glenoid models. We hypothesized that (1) a significant difference in average reaming deviation would be found between reamer types and (2) less ream-to-ream variation would occur with the Marksman reamer. METHODS: Retroversion correction of 18 identical Sawbones glenoid models was conducted using either a hand, power, or Marksman reamer with a 40-mm curvature radius. Glenoid correction with either 0° or 10° reaming was conducted in triplicate sets for each reamer. Reamed glenoid computed tomography images were 3-dimensionally reconstructed using Mimics Medical software (version 21.0). Congruency between the glenoid surface and a 3-dimensional sphere with a 40-mm curvature radius was analyzed. Average deviation and ream-to-ream variance were compared between the hand, power, and Marksman reamer groups. RESULTS: The power reamer demonstrated the smallest median deviation (0.08 mm; interquartile range [IQR], 0.07-0.19 mm), followed by the Marksman (0.09 mm; IQR, 0.08-0.17 mm) and hand (0.11 mm; IQR, 0.10-0.13 mm) reamers. Kruskal-Wallis analysis indicated no significant difference in deviation among the 3 reaming methods (P = .42). The Marksman reamer demonstrated the least variance (0.0034 mm), followed by the power (0.0076 mm) and hand (0.0093 mm) reamers. The results of the Conover squared ranks test indicated no significant difference in variance among the 3 reaming methods (P = .32). CONCLUSION: Our findings showed no statistically significant difference in the accuracy or consistency of reaming between reamer types. Trends showed less variance in the Marksman reamer group compared with the hand and power reamer groups, although differences in variation between groups were not statistically significant.
Assuntos
Procedimentos Ortopédicos/instrumentação , Escápula/cirurgia , Humanos , Modelos Anatômicos , Escápula/diagnóstico por imagem , Articulação do Ombro , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND: Devastating transient and permanent postoperative neurocognitive complications in previously healthy, low-risk patients have been observed after elective shoulder arthroscopy in the beach chair position (BCP). Continuous monitoring of cerebral oxygen saturation has been recommended to identify cerebral desaturation events (CDEs) and improve patient safety. However, the relatively high cost and limited availability of monitoring may not be cost-effective. More cost-effective and available measures, including the use of thigh-high compression stockings (CS), have been investigated. However, efficacy data of CS usage is limited, especially for obese patients, who have been shown to be at increased risk for CDEs. The purpose of this was study was to determine if the intraoperative addition of thigh-high compression stockings decreases the incidence, frequency, and magnitude of CDEs in obese patients undergoing shoulder arthroscopy in the BCP. METHODS: Thirty-three patients in the treatment group wore both thigh-high compression stockings (CS) and sequential compression devices (SCDs), and the remaining 33 patients in the control group wore SCDs alone. Cerebral oximetry was monitored during surgery using near-infrared spectroscopy. RESULTS: The incidence of CDEs was equal between groups, with 9 patients (27%) in each experiencing desaturation events. The median number of CDEs per patient was 3 for the control group and 1 for patients wearing CS (P = .29). There was no difference between groups in terms of median time from induction of anesthesia to onset of CDE (P = .79), median time from upright positioning to onset of CDE (P = .60), mean CDE duration per patient (P = .22), and median cumulative CDE duration (P = .19). The median maximal desaturation from baseline was also not different between groups: 27.6% in the control group and 24.3% in the treatment group (P = .35). CONCLUSION: The combination of thigh-high CS and SCDs did not decrease the incidence, frequency, or magnitude of CDEs in patients undergoing shoulder arthroscopy in the BCP. Twenty-seven percent of patients undergoing shoulder arthroscopy in the BCP demonstrated CDEs with or without the use of CS. Therefore, further research is required to identify cost-effective, minimally invasive, and universally available methods of decreasing the incidence of CDEs during this common surgical procedure.
Assuntos
Artroscopia/efeitos adversos , Encéfalo/irrigação sanguínea , Obesidade/fisiopatologia , Posicionamento do Paciente/efeitos adversos , Articulação do Ombro/cirurgia , Meias de Compressão , Adulto , Idoso , Artroscopia/métodos , Circulação Cerebrovascular , Feminino , Humanos , Dispositivos de Compressão Pneumática Intermitente , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Oximetria , Oxigênio/sangue , Estudos Prospectivos , Postura SentadaRESUMO
Given the increase in the incidence and survivability of those with solid organ transplantations in the United States, the purpose of this study was to identify inpatient, 30-day, and 90-day outcomes following primary shoulder arthroplasty in transplant recipients. The Healthcare Cost and Utilization Project State Inpatient Databases identified patients who underwent shoulder arthroplasty after solid organ transplantation between January 2007 and December 2013. International Classification of Diseases, Ninth Revision, codes were used to define the primary composite outcome of death or postoperative complication. Logistic models with frequency weights were used to compare propensity-matched groups. Patients undergoing primary shoulder arthroplasty following solid organ transplant are at elevated risk of inpatient and 30-day and 90-day postoperative complications (respiratory, hemorrhage) and have longer length of stays compared with nontransplant patients. Transplant patients did not have an increased risk of surgical site infection or mortality at any time point (Journal of Surgical Orthopaedic Advances 28(1):41-47, 2019).
Assuntos
Artroplastia do Ombro , Transplantados , Bases de Dados Factuais , Humanos , Complicações Pós-Operatórias , Estudos Retrospectivos , Estados UnidosRESUMO
BACKGROUND: Fractures of the capitellum are rare and are commonly classified into 4 types. Type II variants involve a shear injury with a mostly articular cartilage component and little subchondral bone. Symptoms upon presentation after these injuries are variable, and the diagnosis can be difficult to make in the immature skeleton. METHODS: We retrospectively reviewed 3 cases of type II capitellar fractures in adolescent athletes who presented for evaluation with the senior author. RESULTS: All patients were initially treated conservatively, without identification or treatment of the capitellar shear component of their injury. Unfortunately, radiocapitellar arthrosis rapidly developed in all 3 and required surgical intervention at our institution. At an average postoperative follow-up of 49 months from the index procedure, patients ultimately had positive outcomes despite advanced degenerative changes on imaging. One patient required 2 subsequent operations for mechanical symptoms and pain. DISCUSSION: The 3 reported cases represent adolescent, athletic patients with missed shear injuries to the capitellum. These patients exhibited low Disabilities of Arm, Shoulder and Hand scores and high Mayo Elbow Performance Scores at final follow-up, but each patient demonstrated advanced degenerative changes on imaging, and 1 patient required 2 subsequent operations for mechanical symptoms and pain. A high index of suspicion is necessary to identify this injury pattern, and proper plain radiographic imaging with a low threshold for advanced imaging is necessary. Although the overall long-term prognosis is unknown for these patients, early recognition likely would have changed the initial conservative management decision in each and, theoretically, might have altered the outcome for these patients.
Assuntos
Lesões no Cotovelo , Articulação do Cotovelo/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Adolescente , Artralgia/etiologia , Artralgia/cirurgia , Traumatismos em Atletas/cirurgia , Moldes Cirúrgicos/efeitos adversos , Criança , Erros de Diagnóstico , Avaliação da Deficiência , Articulação do Cotovelo/cirurgia , Feminino , Fraturas Ósseas/cirurgia , Humanos , Masculino , Modalidades de Fisioterapia/efeitos adversos , Amplitude de Movimento Articular , Estudos Retrospectivos , Falha de TratamentoRESUMO
PURPOSE: To determine if the use of thigh-high compression stockings could decrease the incidence of cerebral desaturation events (CDEs) in patients with a body mass index (BMI) of 30 kg/m(2) or greater undergoing shoulder arthroscopy in the beach-chair position (BCP). METHODS: Between December 2013 and May 2014, 23 patients aged 18 years or older with a BMI of 30 kg/m(2) or greater undergoing shoulder arthroscopy in the BCP were monitored intraoperatively using near-infrared spectroscopy while wearing thigh-high compression stockings. Data obtained on these patients were compared with data from a previous cohort at our institution comprising 24 patients with a BMI of 30 kg/m(2) or greater who underwent elective shoulder arthroscopy in the BCP with the same monitoring but without wearing compression stockings. The incidence of CDEs was identified in each group. RESULTS: The incidence of CDEs in the group with compression stockings was 4% (1 of 23) compared with 18% (7 of 24) in the group without compression stockings (P = .048). There were no statistically significant differences in mean age (53.0 years v 53.3 years, P = .91), mean BMI (34.5 kg/m(2)v 36.2 kg/m(2), P = .21), or various medical comorbidities between the treatment group and control group. There was a significant difference in the operative time between the treatment group (156.6 minutes) and control group (94.1 minutes) (P < .001). CONCLUSIONS: The use of thigh-high compression stockings may decrease the incidence of CDEs in obese patients undergoing shoulder arthroscopy in the BCP. LEVEL OF EVIDENCE: Level IV, therapeutic case series.
Assuntos
Hipóxia Encefálica/prevenção & controle , Artropatias/cirurgia , Obesidade/complicações , Postura/fisiologia , Articulação do Ombro/cirurgia , Meias de Compressão , Adulto , Idoso , Artroscopia/métodos , Feminino , Humanos , Hipóxia Encefálica/etiologia , Artropatias/complicações , Masculino , Pessoa de Meia-Idade , Oxigênio/análise , Posicionamento do Paciente/efeitos adversos , Estudos Prospectivos , Espectroscopia de Luz Próxima ao InfravermelhoRESUMO
BACKGROUND: Little is known about the role that a torn superior labrum (SLAP) plays in glenohumeral stability after biceps tenodesis. This biomechanical study evaluated the contribution of a type II SLAP lesion to glenohumeral translation in the presence of biceps tenodesis. The authors hypothesize that subsequent to biceps tenodesis, a torn superior labrum does not affect glenohumeral stability and therefore does not require anatomic repair in an overhead throwing athlete. METHODS: Baseline anterior, posterior, and abduction and maximal external rotation glenohumeral translation data were collected from 20 cadaveric shoulders. Translation testing was repeated after the creation of anterior (n = 10) and posterior (n = 10) type II SLAP lesions. Translation re-evaluation after biceps tenodesis was performed for each specimen. Finally, anatomic SLAP lesion repair and testing were performed. RESULTS: Anterior and posterior SLAP lesions led to significant increases in glenohumeral translation in all directions (P < .0125). Biceps tenodesis showed no significance in stability compared with SLAP alone (P > .0125). Arthroscopic repair of anterior SLAP lesions did not restore anterior translation compared with the baseline state (P = .0011) but did restore posterior (P = .823) and abduction and maximal external rotation (P = .806) translations. Repair of posterior SLAP lesions demonstrated no statistical difference compared with the baseline state (P > .0125). CONCLUSIONS: With no detrimental effect on glenohumeral stability in the presence of a SLAP lesion, biceps tenodesis may be considered a valid primary or revision surgery for patients suffering from symptomatic type II SLAP tears. However, biceps tenodesis should be considered with caution as the primary treatment of SLAP lesions in overhead throwing athletes secondary to its inability to completely restore translational stability.
Assuntos
Traumatismos em Atletas/cirurgia , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Tenodese , Adulto , Idoso , Artroscopia , Traumatismos em Atletas/fisiopatologia , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/cirurgia , Amplitude de Movimento Articular , Rotação , Lesões do Ombro , Articulação do Ombro/fisiopatologia , Traumatismos dos Tendões/fisiopatologia , Traumatismos dos Tendões/cirurgia , Adulto JovemRESUMO
Introduction: Assessing scholarly contributions in academic orthopaedic surgery remains challenging, despite the importance of publication productivity in evaluating academic leaders. The Hirsch (h)-index and its derivative, the m-index, offer objective measures to compare and evaluate publication productivity. The primary aims of this study were to compare h- and m-indices of department chairs and residency program directors of orthopaedic training programs in the United States and assess the association between h-index and program rank. Methods: A publicly available Doximity report was used to identify and rank orthopaedic surgery residency programs in the United States. Internet-based searches of institution-specific websites were performed to confirm current department chairs and residency program directors as of January 2024. H-index data were collected from a publicly available database known as Scopus. The m-index was calculated as the quotient of h-index and years in practice. Gender and years in practice were obtained through available biographies on institution-specific websites. Results: Department chairs had significantly higher h- and m-indices at both the career and 5-year time intervals compared with program directors. Upon subgroup analysis, department chairs and program directors at top-10 ranked programs had significantly higher h- and m-indices compared with the entire population of department chairs and program directors. Linear regression analyses demonstrated a direct linear association between department chair/program director h- and m-indices and program rank. Conclusions: Publication productivity was higher for department chairs than residency program directors. Orthopaedic leaders at top-10 institutions had higher publication productivity compared with those at institutions outside of the top 10, per Doximity rankings. Finally, there is substantial variation in publication productivity of orthopaedic surgeons in leadership roles at academic institutions in the United States. Clinical Relevance: This study highlights the publication productivity of orthopaedic surgery department chairs and residency program directors and describes the linear association between publication productivity of academic orthopaedic leaders and program rank. This information can be utilized by those interested in learning more about the publication productivity among academic orthopaedic surgeons across different institutions and can assist those who are involved in the hiring and promotion process at these academic institutions.
RESUMO
BACKGROUND: Accurate and precise templating is paramount for anatomic total shoulder arthroplasty (TSA) and reverse total shoulder arthroplasty (RSA) to enhance preoperative planning, streamline surgery, and improve implant positioning. We aimed to evaluate the predictive potential of readily available patient demographic data in TSA and RSA implant sizing, independent of implant design. METHODS: A total of 578 consecutive, primary, noncemented shoulder arthroplasty cases were retrospectively reviewed. Demographic variables and implant characteristics were recorded. Multivariate linear regressions were conducted to predict implant sizes using patient demographic variables. RESULTS: Linear models accurately predict TSA implant sizes within 2 millimeters of humerus stem sizes 75.3% of the time, head diameter 82.1%, head height 82.1%, and RSA glenosphere diameter 77.6% of the time. Linear models predict glenoid implant sizes accurately 68.2% and polyethylene thickness 76.6% of the time and within one size 100% and 95.7% of the time, respectively. CONCLUSION: Linear models accurately predict shoulder arthroplasty implant sizes from demographic data. No significant statistical differences were observed between linear models and machine learning algorithms, although the analysis was underpowered. Future sufficiently powered studies are required for more robust assessment of machine learning models in predicting primary shoulder arthroplasty implant sizes based on patient demographics.
Assuntos
Artroplastia do Ombro , Aprendizado de Máquina , Humanos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Prótese de Ombro , Pessoa de Meia-Idade , Desenho de Prótese , Modelos Lineares , Inteligência Artificial , Algoritmos , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia , Articulação do Ombro/anatomia & histologiaRESUMO
BACKGROUND: Minimally invasive Q3 repair has been proposed for acute Achilles tendon rupture with low rate of complications. However there are still controversies about optimal technique. In this study we aimed to describe Endobutton-assisted modified Bunnell configuration as a new Achilles tendon repair technique and evaluate its biomechanical properties comparing with native tendon and Krackow technique. METHODS: 27 ovine Achilles tendons were obtained and randomly placed into 3 groups with 9 specimens ineach. The Achilles tendons were repaired with Endobutton-assisted modified Bunnell technique in group 1, Krackow suture technique in group 2 and group 3 was defined as the control group including native tendons. Unidirectional tensile loading to failure was performed at 25mm/min. Biomechanicalproperties such as peak force to failure (N), stress at peak (MPa), elongation at failure, and Young'smodulus (GPa) was measured for each group. All groups were compared with each other using one-wayANOVA followed by the Tukey HSD multiple comparison test (a=0.05). RESULTS: The average peak force (N) to failure of group 1 and group 2 and control group was 415.6±57.6, 268.1±65.2 and 704.5±85.8, respectively. There was no statistically significant difference between native tendon and group 1 for the amount elongation at failure (p>0.05). CONCLUSIONS: Regarding the results, we concluded that Endobutton-assisted modified Bunnell technique provides stronger fixation than conventional techniques. It may allow early range of motion and can be easily applied in minimally invasive and percutaneous methods particularly for cases with poor quality tendon at the distal part of rupture. LEVEL OF EVIDENCE: Level II, Biomechanical research study.
Assuntos
Tendão do Calcâneo/cirurgia , Dispositivos de Fixação Ortopédica , Estresse Mecânico , Técnicas de Sutura , Resistência à Tração , Tendão do Calcâneo/lesões , Análise de Variância , Animais , Modelos Animais , Distribuição Aleatória , Ruptura/cirurgia , OvinosRESUMO
This case study examines an adolescent athlete who had an avulsion fracture of the lesser tuberosity of the humerus. This is a relatively rare injury, although a collection of case studies have identified an increase in this type of injury in the past 15 years. Uniquely, the patient experienced a delay in appropriate diagnosis for approximately 3 years from the time of his initial injury. This is one of the most significant delays in diagnosis and treatment in the current body of literature regarding lesser tuberosity fractures. The authors include a detailed series of imaging studies, including preoperative plain radiographs, preoperative computed tomography, intraoperative arthroscopic images, and postoperative plain radiographs. In addition, a thorough description of the patient's surgery is presented. The degree of scarring to the axillary nerve present in this patient required conversion to a full open reduction. The authors' aim is that this case can be used as a reference for future surgical decision making, particularly in pediatric patients whose injuries are highly chronic or who are actively involved in athletic physical training programs. [Orthopedics. 2023;46(3):e189-e192.].
Assuntos
Fratura Avulsão , Fraturas do Ombro , Humanos , Adolescente , Criança , Fratura Avulsão/diagnóstico por imagem , Fratura Avulsão/cirurgia , Radiografia , Fraturas do Ombro/cirurgia , Tomografia Computadorizada por Raios X , ÚmeroRESUMO
Avascular necrosis (AVN) of the humeral head is a rare, yet detrimental complication. Left untreated, humeral head AVN frequently progresses to subchondral fracturing and articular collapse. Cases of late-stage humeral head AVN commonly require invasive procedures including humeral head resurfacing, hemiarthroplasty, and total shoulder arthroplasty (TSA) to improve clinical outcomes. However, in cases of early-stage AVN, core decompression of the humeral head is a viable and efficacious short-term treatment option for patients with pre-collapse AVN of the humeral head to improve clinical outcomes and prevent disease progression. Several techniques have been described, however, a percutaneous, arthroscopic-assisted technique may allow for accurate staging and concomitant treatment of intraarticular pathology during surgery, although further long-term clinical studies are necessary to assess its overall outcomes compared with standard techniques. Biologic adjunctive treatments, including synthetic bone grafting, autologous mesenchymal stem cell/bone marrow grafts, and bone allografts are viable options for reducing the progression of AVN to further collapse in the short term, although long-term follow-up with sufficient study power is lacking in current clinical studies. Further long-term outcome studies are required to determine the longevity of core decompression as a conservative measure for early-stage AVN of the humeral head.
RESUMO
BACKGROUND: Advancements in airport screening measures in response to 9/11 have resulted in increased false alarm rates for patients with orthopedic and metal implants. With the implementation of millimeter-wave scanning technology, it is important to assess the changes in airport screening experiences of patients who underwent total shoulder arthroplasty (TSA). METHODS: Here, 197 patients with prior anatomic and reverse TSA completed between 2013 and 2020 responded to a questionnaire regarding their experiences with airport travel screening after their operation. Of these patients, 86 (44%) stated that they had traveled by plane, while 111 (56%) had not. The questionnaire addressed several measures including the number of domestic and international flights following the operation, number of false alarm screenings by the millimeter-wave scanner, patient body habitus, and presence of additional metal implants. RESULTS: A total of 53 patients (62%) responded "yes" to false screening alarms due to shoulder arthroplasty. The odds of a false screening alarm for patients with other metal implants was 5.87 times that of a false screening alarm for patients with no other metal implants (P<0.1). Of a reported 662 flights, 303 (45.8%) resulted in false screening alarms. Greater body mass index was not significantly lower in patients who experienced false screening alarms (P=0.30). CONCLUSIONS: Patients with anatomic and reverse TSA trigger false alarms with millimeter-wave scanners during airport screening at rates consistent with prior reports following 9/11. Patient education on the possibility of false alarms during airport screening is important until improvements in implant identification are made. Level of evidence: IV.
RESUMO
BACKGROUND: Sleep quality, quantity, and efficiency have all been demonstrated to be adversely affected by rotator cuff pathology. Previous measures of assessing the impact of rotator cuff pathology on sleep have been largely subjective in nature. This study was undertaken to objectively analyze this relationship through the use of activity monitors. METHODS: Patients with full-thickness rotator cuff tears at a single institution were prospectively enrolled between 2018 and 2020. Waistworn accelerometers were provided for the patients to use each night for 14 days. Sleep efficiency was calculated using the ratio of the time spent sleeping to the total amount of time that was spent in bed. Retraction of the rotator cuff tear was classified using the Patte staging system. RESULTS: This study included 36 patients: 18 with Patte stage 1 disease, 14 with Patte stage 2 disease, and 4 patients with Patte stage 3 disease. During the study, 25 participants wore the monitor on multiple nights, and ultimately their data was used for the analysis. No difference in the median sleep efficiency was appreciated amongst these groups (P>0.1), with each cohort of patients demonstrating a generally high sleep efficiency. CONCLUSIONS: The severity of retraction of the rotator cuff tear did not appear to correlate with changes in sleep efficiency for patients (P>0.1). These findings can better inform providers on how to counsel their patients who present with complaints of poor sleep in the setting of full-thickness rotator cuff tears. Level of evidence: Level II.
RESUMO
Distinguishing between partial-thickness and small focal full-thickness tears of rotator cuff may be important for determining the appropriate surgical treatment options and repair constructs in the care of patients with rotator cuff pathology. This article presents a simple intraoperative technical trick to aid in identification of small full-thickness tears of the superior rotator cuff. The relatively higher-pressured subacromial space and the low-pressured glenohumeral joint are separated by the supraspinatus tendon. When this barrier is compromised due to a full-thickness tear, free fluid flows from high to low pressure down the native pressure gradient. This is seen as the movement of air bubbles into the glenohumeral joint from the subacromial space and can be used to identify the presence of a full-thickness rotator cuff tear on diagnostic arthroscopy.
RESUMO
Currently, the literature contains few studies that describe any potential complications following arthroscopic acromioplasty. Because part of the anterior deltoid originates from the anterior acromion, there is a risk for violation and subsequent iatrogenic rupture or avulsion during this procedure. This type of injury can be a devastating problem for patients that may lead to poor function and debilitating pain. We present a patient with deltoid insufficiency following arthroscopic acromioplasty who elected to proceed with operative management with a planned arthroscopic evaluation of the shoulder followed by an open deltoid repair. At the final follow-up visit 2.5 years postoperatively, the patient reported improved pain from baseline and no residual disability and was able to perform most activities of daily living without difficulty. This case serves as an example of a surgical repair for a deltoid avulsion following arthroscopic acromioplasty. As there is still a lack of standard guidelines, our suture repair technique can be considered one method of treatment for this type of injury.