Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Pharmacol Exp Ther ; 390(2): 260-275, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-38858089

RESUMO

Radiation therapy, a standard treatment option for many cancer patients, induces DNA double-strand breaks (DSBs), leading to cell death. Ataxia telangiectasia mutated (ATM) kinase is a key regulator of DSB repair, and ATM inhibitors are being explored as radiosensitizers for various tumors, including primary and metastatic brain tumors. Efficacy of radiosensitizers for brain tumors may be influenced by a lack of effective drug delivery across the blood-brain barrier. The objective of this study was to evaluate the systemic pharmacokinetics and mechanisms that influence the central nervous system (CNS) distribution of WSD0628, a novel and potent ATM inhibitor, in the mouse. Further, we have used these observations to form the basis of predicting effective exposures for clinical application. We observed a greater than dose proportional increase in exposure, likely due to saturation of clearance processes. Our results show that WSD0628 is orally bioavailable and CNS penetrant, with unbound partitioning in CNS (i.e., unbound tissue partition coefficient) between 0.15 and 0.3. CNS distribution is not limited by the efflux transporters P-glycoprotein and breast cancer resistant protein. WSD0628 is distributed uniformly among different brain regions. Thus, WSD0628 has favorable pharmacokinetic properties and potential for further exploration to determine the pharmacodynamics-pharmacokinetics efficacy relationship in CNS tumors. This approach will provide critical insights for the clinical translation of WSD0628 for the treatment of primary and secondary brain tumors. SIGNIFICANCE STATEMENT: This study evaluates the preclinical systemic pharmacokinetics, dose proportionality, and mechanisms influencing CNS distribution of WSD0628, a novel ATM inhibitor for the treatment of brain tumors. Results indicate that WSD0628 is orally bioavailable and CNS penetrant without efflux transporter liability. We also observed a greater than dose proportional increase in exposure in both the plasma and brain. These favorable pharmacokinetic properties indicate WSD0628 has potential for further exploration for use as a radiosensitizer in the treatment of brain tumors.


Assuntos
Proteínas Mutadas de Ataxia Telangiectasia , Neoplasias Encefálicas , Radiossensibilizantes , Animais , Proteínas Mutadas de Ataxia Telangiectasia/antagonistas & inibidores , Camundongos , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/radioterapia , Radiossensibilizantes/farmacocinética , Radiossensibilizantes/administração & dosagem , Masculino , Feminino , Relação Dose-Resposta a Droga , Distribuição Tecidual , Sistema Nervoso Central/metabolismo , Sistema Nervoso Central/efeitos dos fármacos , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/antagonistas & inibidores , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Membro 2 da Subfamília G de Transportadores de Cassetes de Ligação de ATP
2.
Int J Radiat Oncol Biol Phys ; 119(3): 924-935, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38310485

RESUMO

PURPOSE: Proton relative biological effectiveness (RBE) is a dynamic variable influenced by factors like linear energy transfer (LET), dose, tissue type, and biological endpoint. The standard fixed proton RBE of 1.1, currently used in clinical planning, may not accurately represent the true biological effects of proton therapy (PT) in all cases. This uncertainty can contribute to radiation-induced normal tissue toxicity in patients. In late-responding tissues such as the spinal cord, toxicity can cause devastating complications. This study investigated spinal cord tolerance in mice subjected to proton irradiation and characterized the influence of fractionation on proton- induced myelopathy at entrance (ENT) and Bragg peak (BP) positions. METHODS AND MATERIALS: Cervical spinal cords of 8-week-old C57BL/6J female mice were irradiated with single- or multi-fractions (18x) using lateral opposed radiation fields at 1 of 2 positions along the Bragg curve: ENT (dose-mean LET = 1.2 keV/µm) and BP (LET = 6.9 keV/µm). Mice were monitored over 1 year for changes in weight, mobility, and general health, with radiation-induced myelopathy as the primary biological endpoint. Calculations of the RBE of the ENT and BP curve (RBEENT/BP) were performed. RESULTS: Single-fraction RBEENT/BP for 50% effect probability (tolerance dose (TD50), grade II paresis, determined using log-logistic model fitting) was 1.10 ± 0.06 (95% CI) and for multifraction treatments it was 1.19 ± 0.05 (95% CI). Higher incidence and faster onset of paralysis were seen in mice treated at the BP compared with ENT. CONCLUSIONS: The findings challenge the universally fixed RBE value in PT, indicating up to a 25% mouse spinal cord RBEENT/BP variation for multifraction treatments. These results highlight the importance of considering fractionation in determining RBE for PT. Robust characterization of proton-induced toxicity, aided by in vivo models, is paramount for refining clinical decision-making and mitigating potential patient side effects.


Assuntos
Fracionamento da Dose de Radiação , Transferência Linear de Energia , Camundongos Endogâmicos C57BL , Terapia com Prótons , Tolerância a Radiação , Eficiência Biológica Relativa , Medula Espinal , Animais , Feminino , Medula Espinal/efeitos da radiação , Camundongos , Terapia com Prótons/efeitos adversos , Prótons/efeitos adversos , Relação Dose-Resposta à Radiação
3.
Cancers (Basel) ; 15(14)2023 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-37509376

RESUMO

In this study, we investigated whether radiomics features from pre-treatment positron emission tomography (PET) images could be used to predict disease progression in patients with HPV-positive oropharyngeal cancer treated with definitive proton or x-ray radiotherapy. Machine learning models were built using a dataset from Mayo Clinic, Rochester, Minnesota (n = 72) and tested on a dataset from Mayo Clinic, Phoenix, Arizona (n = 22). A total of 71 clinical and radiomics features were considered. The Mann-Whitney U test was used to identify the top 2 clinical and top 20 radiomics features that were significantly different between progression and progression-free patients. Two dimensionality reduction methods were used to define two feature sets (manually filtered or machine-driven). A forward feature selection scheme was conducted on each feature set to build models of increased complexity (number of input features from 1 to 6) and evaluate model robustness and overfitting. The machine-driven features had superior performance and were less prone to overfitting compared to the manually filtered features. The four-variable Gaussian Naïve Bayes model using the 'Radiation Type' clinical feature and three machine-driven features achieved a training accuracy of 79% and testing accuracy of 77%. These results demonstrate that radiomics features can provide risk stratification beyond HPV-status to formulate individualized treatment and follow-up strategies.

4.
Radiat Res ; 195(6): 541-548, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33826742

RESUMO

The uncertainty associated with the relative biological effectiveness (RBE) in proton therapy, particularly near the Bragg peak (BP), has led to the shift towards biological-based treatment planning. Proton RBE uncertainty has recently been reported as a possible cause for brainstem necrosis in pediatric patients treated with proton therapy. Despite this, in vivo studies have been limited due to the complexity of accurate delivery and absolute dosimetry. The purpose of this investigation was to create a precise and efficient method of treating the mouse spinal cord with various portions of the proton Bragg curve and to quantify associated uncertainties for the characterization of proton RBE. Mice were restrained in 3D printed acrylic boxes, shaped to their external contour, with a silicone insert extending down to mold around the mouse. Brass collimators were designed for parallel opposed beams to treat the spinal cord while shielding the brain and upper extremities of the animal. Up to six animals may be accommodated for simultaneous treatment within the restraint system. Two plans were generated targeting the cervical spinal cord, with either the entrance (ENT) or the BP portion of the beam. Dosimetric uncertainty was measured using EBT3 radiochromic film with a dose-averaged linear energy transfer (LETd) correction. Positional uncertainty was assessed by collecting a library of live mouse scans (n = 6 mice, two independent scans per mouse) and comparing the following dosimetric statistics from the mouse cervical spinal cord: Volume receiving 90% of the prescription dose (V90); mean dose to the spinal cord; and LETd. Film analysis results showed the dosimetric uncertainty to be ±1.2% and ±5.4% for the ENT and BP plans, respectively. Preliminary results from the mouse library showed the V90 to be 96.3 ± 4.8% for the BP plan. Positional uncertainty of the ENT plan was not measured due to the inherent robustness of that treatment plan. The proposed high-throughput mouse proton irradiation setup resulted in accurate dose delivery to mouse spinal cords positioned along the ENT and BP. Future directions include adapting the setup to account for weight fluctuations in mice undergoing fractionated irradiation.


Assuntos
Terapia com Prótons/efeitos adversos , Medula Espinal/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Camundongos , Radiometria , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA