RESUMO
BACKGROUND: "ALARA--As Low As Reasonably Achievable" protocols reduce patient radiation dose. Addition of electroanatomical mapping may further reduce dose. METHODS: From 6/11 to 4/12, a novel ALARA protocol was utilised for all patients undergoing supraventricular tachycardia ablation, including low frame rates (2-3 frames/second), low fluoro dose/frame (6-18 nGy/frame), and other techniques to reduce fluoroscopy (ALARA). From 6/12 to 3/13, use of CARTO® 3 (C3) with "fast anatomical mapping" (ALARA+C3) was added to the ALARA protocol. Intravascular echo was not utilised. Demographics, procedural, and radiation data were analysed and compared between the two protocols. RESULTS: A total of 75 patients were included: 42 ALARA patients, and 33 ALARA+C3 patients. Patient demographics were similar between the two groups. The acute success rate in ALARA was 95%, and 100% in ALARA+C3; no catheterisation-related complications were observed. Procedural time was 125.7 minutes in the ALARA group versus 131.4 in ALARA+C3 (p=0.36). Radiation doses were significantly lower in the ALARA+C3 group with a mean air Kerma in ALARA+C3 of 13.1±28.3 mGy (SD) compared with 93.8±112 mGy in ALARA (p<0.001). Mean dose area product was 92.2±179 uGym2 in ALARA+C3 compared with 584±687 uGym2 in ALARA (p<0.001). Of the 33 subjects (42%) in the ALARA+C3 group, 14 received ⩽1 mGy exposure. The ALARA+C3 dosages are the lowest reported for a combined electroanatomical-fluoroscopy technique. CONCLUSIONS: Addition of CARTO® 3 to ALARA protocols markedly reduced radiation exposure to young people undergoing supraventricular tachycardia ablation while allowing for equivalent procedural efficacy and safety.