Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Anat ; 244(1): 63-74, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37694853

RESUMO

The apophyseal growth plate of the greater trochanter, unlike most other growth plates of the human body, exhibits a curved morphology that results in a divergent pattern resembling an open crocodile mouth on plain antero-posterior radiographs. To quantify the angular alignment of the growth plate and to draw conclusions about the function of the muscles surrounding it, we analyzed 57 MRI images of 51 children and adolescents aged 3-17 years and of six adults aged 18-52 years. We measured the angulation of the plate relative to the horizontal plane (AY angle) and the trajectories of the muscles attaching to the greater trochanter of the proximal femur. From anterior to posterior, the AY angle shows a decrease of 33.44°. In the anterior third, the cartilage is angled at a mean of 51.64°, and in the posterior third, the mean angulation is 18.6°. This indicates that the cartilage in the anterior region of the greater trochanteric apophysis is subject to more vertically oriented force vectors compared to the posterior region, as the growth plates align perpendicular to the force vectors acting on them. Combining the measured muscle trajectories with the physiological cross-sectional areas (PCSA) available from the literature revealed that, in addition to the known internal and external lateral traction ligament systems, a third, dorsally located traction ligament system exists that may be responsible for the dorsal deformation of the AY angle.


Assuntos
Lâmina de Crescimento , Articulação do Quadril , Criança , Adulto , Adolescente , Humanos , Lâmina de Crescimento/diagnóstico por imagem , Fenômenos Biomecânicos , Articulação do Quadril/anatomia & histologia , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Músculos
2.
BMC Med Imaging ; 24(1): 43, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350900

RESUMO

BACKGROUND: A deep learning (DL) model that automatically detects cardiac pathologies on cardiac MRI may help streamline the diagnostic workflow. To develop a DL model to detect cardiac pathologies on cardiac MRI T1-mapping and late gadolinium phase sensitive inversion recovery (PSIR) sequences were used. METHODS: Subjects in this study were either diagnosed with cardiac pathology (n = 137) including acute and chronic myocardial infarction, myocarditis, dilated cardiomyopathy, and hypertrophic cardiomyopathy or classified as normal (n = 63). Cardiac MR imaging included T1-mapping and PSIR sequences. Subjects were split 65/15/20% for training, validation, and hold-out testing. The DL models were based on an ImageNet pretrained DenseNet-161 and implemented using PyTorch and fastai. Data augmentation with random rotation and mixup was applied. Categorical cross entropy was used as the loss function with a cyclic learning rate (1e-3). DL models for both sequences were developed separately using similar training parameters. The final model was chosen based on its performance on the validation set. Gradient-weighted class activation maps (Grad-CAMs) visualized the decision-making process of the DL model. RESULTS: The DL model achieved a sensitivity, specificity, and accuracy of 100%, 38%, and 88% on PSIR images and 78%, 54%, and 70% on T1-mapping images. Grad-CAMs demonstrated that the DL model focused its attention on myocardium and cardiac pathology when evaluating MR images. CONCLUSIONS: The developed DL models were able to reliably detect cardiac pathologies on cardiac MR images. The diagnostic performance of T1 mapping alone is particularly of note since it does not require a contrast agent and can be acquired quickly.


Assuntos
Aprendizado Profundo , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Meios de Contraste , Pericárdio
3.
J Magn Reson Imaging ; 57(2): 622-630, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35582900

RESUMO

BACKGROUND: Diagnosis of residual or recurrent tumor in soft-tissue sarcomas (STS) is a differential diagnostic challenge since post-therapeutic changes impede diagnosis. PURPOSE: To evaluate the diagnostic accuracy of quantitative dynamic contrast enhanced (DCE)-MRI and diffusion-weighted imaging (DWI) to detect local recurrence of STS of the limb. STUDY TYPE: Prospective. POPULATION: A totalof 64 consecutive patients with primary STS of the limbs were prospectively included 3-6 months after surgery between January 2016 and July 2021. FIELD STRENGTH/SEQUENCE: A 1.5 T; axial DWI echo-planar imaging sequences and DCE-MRI using a 3D T1-weighted spoiled gradient-echo sequence. ASSESSMENT: The quantitative DCE-MRI parameters relative plasma flow (rPF) and relative mean transit time (rMTT) were calculated and ADC mapping was used to quantify diffusion restriction. Regions of interest of tumor growth and postoperative changes were drawn in consensus by two experts for diffusion and perfusion analysis. An additional morphological assessment was done by three independent and blinded radiologists. STATISTICAL TEST: Unpaired t-test, ROC-analysis, and a logistic regression model were applied. Interobserver reliability was calculated using Fleiss kappa statistics. A P value of 0.05 was considered statistically significant. RESULTS: A total of 11 patients turned out to have local recurrence. rPF was significantly higher in cases of local recurrence when compared to cases without local recurrence (61.1-4.5) while rMTT was slightly and significantly lower in local recurrence. ROC-analysis showed an area under the curve (AUC) of 0.95 (SEM ± 0.05) for rPF while a three-factor multivariate logistic regression model showed a high diagnostic accuracy of rPF (R2  = 0.71). Compared with morphological assessment, rPF had a distinct higher specificity and true positive value in detection of LR. DATA CONCLUSION: DCE-MRI is a promising additional method to differentiate local recurrence from benign postoperative changes in STS of the limb. Especially specificity in detection of LR is increased compared to morphological assessment. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Sarcoma , Neoplasias de Tecidos Moles , Humanos , Reprodutibilidade dos Testes , Estudos Prospectivos , Meios de Contraste , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Sarcoma/diagnóstico por imagem , Sensibilidade e Especificidade
4.
Eur Radiol ; 33(11): 7380-7387, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37284864

RESUMO

OBJECTIVE: For transjugular intrahepatic portosystemic shunt (TIPS) creation, ultrasound guidance for portal vein puncture is strongly recommended. However, outside regular hours of service, a skilled sonographer might be lacking. Hybrid intervention suites combine CT imaging with conventional angiography allowing to project 3D information into the conventional 2D imaging and further CT-fluoroscopic puncture of the portal vein. The purpose of this study was to assess whether TIPS using angio-CT facilitates the procedure for a single interventional radiologist. METHODS: All TIPS procedures from 2021 and 2022 which took place outside regular working hours were included (n = 20). Ten TIPS procedures were performed with just fluoroscopy guidance and ten procedures using angio-CT. For the angio-CT TIPS, a contrast-enhanced CT was performed on the angiography table. From the CT, a 3D volume was created using virtual rendering technique (VRT). The VRT was blended with the conventional angiography image onto the live monitor and used as guidance for the TIPS needle. Fluoroscopy time, area dose product, and interventional time were assessed. RESULTS: Hybrid intervention with angio-CT did lead to a significantly shorter fluoroscopy time and interventional time (p = 0.034 for both). Mean radiation exposure was significantly reduced, too (p = 0.04). Furthermore, the mortality rate was lower in patients who underwent the hybrid TIPS (0% vs 33%). CONCLUSION: TIPS procedure in angio-CT performed by only one interventional radiologist is quicker and reduces radiation exposure for the interventionalist compared to mere fluoroscopy guidance. The results further indicate increased safety using angio-CT. CLINICAL RELEVANCE STATEMENT: This study aimed to evaluate the feasibility of using angio-CT in TIPS procedures during non-standard working hours. Results indicated that the use of angio-CT significantly reduced fluoroscopy time, interventional time, and radiation exposure, while also leading to improved patient outcomes. KEY POINTS: • Image guiding such as ultrasound is recommended for transjugular intrahepatic portosystemic shunt creation but might be not available for emergency cases outside of regular working hours. • Transjugular intrahepatic portosystemic shunt creation using an angio-CT with image fusion is feasible for only one physician under emergency settings and results in lower radiation exposure and faster procedures. • Transjugular intrahepatic portosystemic shunt creation using an angio-CT with image fusion seems to be safer than using mere fluoroscopy guidance.


Assuntos
Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Angiografia , Ultrassonografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Estudos Retrospectivos
5.
Acta Radiol ; 64(1): 119-124, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34866428

RESUMO

BACKGROUND: Catheter-directed thrombolysis (CDT) is an effective and safe endovascular method used in critical limb ischemia and many other thromboembolic events. Ultrasound-assisted catheter-directed thrombolysis (US-CDT) is an emerging technique considered to accelerate thrombolysis and therefore is supposed to improve outcome. PURPOSE: To evaluate the efficacy of US-CDT in comparison to standard CDT in vitro. MATERIAL AND METHODS: A total of 69 sets of human venous blood were evaluated, each comprising a tube just treated with CDT, a tube treated with US-CDT, and a control tube. All tubes were kept under physiological conditions. Except for the controls, in all tubes 5 mg of tissue-type plasminogen activator was administered over the predetermined treatment interval. Thrombus mass was weighted at the end of the lysis intervals at 6 h or 24 h, respectively. RESULTS: CDT led to a mean thrombus reduction of 32% and ultrasound-assisted lysis led to a mean thrombus reduction of 41% (P < 0.001 for both). Thrombus reduction was significantly higher after US-CDT compared to CDT (P = 0.001). The better efficacy of US-CDT was mostly already apparent at early phases during thrombolysis and did further mildly increase over time (r = 0.24; P = 0.047). CONCLUSION: In vitro US-CDT is significantly superior to standard CDT; this effect is apparent at an early timepoint of lysis and slightly further increases over time.


Assuntos
Fibrinolíticos , Terapia Trombolítica , Humanos , Fibrinolíticos/uso terapêutico , Terapia Trombolítica/métodos , Resultado do Tratamento , Ultrassonografia , Catéteres , Estudos Retrospectivos
6.
Radiologe ; 62(3): 205-209, 2022 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-35029722

RESUMO

The S3 guideline on hepatocellular carcinoma has been expanded to include malignant biliary carcinoma (synonym cholangiocarcinoma [CCA]). Magnetic resonance imaging (MRI) with additional magnetic resonance cholangiopancreatography (MRCP) is the imaging modality of choice to evaluate local findings. Use of gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-based contrast agent increases its diagnostic value. Histologic confirmation is always required when diagnosing intrahepatic CCA (iCCA) because using imaging alone there is a risk of confusion with HCC subtypes.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Carcinoma Hepatocelular/diagnóstico por imagem , Colangiocarcinoma/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
7.
J Biomed Sci ; 28(1): 42, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34098949

RESUMO

BACKGROUND: The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. METHODS: Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm3. Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. RESULTS: X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. CONCLUSIONS: X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Microscopia de Contraste de Fase/métodos , Osteoartrite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Cartilagem Articular/patologia , Feminino , Humanos , Masculino , Osteoartrite/etiologia , Osteoartrite/patologia
8.
Radiologe ; 61(1): 80-86, 2021 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-32816049

RESUMO

BACKGROUND: Transcatheter arterial chemoembolization (TACE) and biliary interventions are common procedures. OBJECTIVES: In this retrospective study, the radiation exposure of patients undergoing hepatic intervention will be analyzed and compared depending on the type and objective of the intervention. MATERIALS AND METHODS: This is an analysis of 7003 data sets of performed TACEs and biliary interventions from the DeGIR registry for the years 2016, 2017, and 2018. The dose area product (DAP), fluoroscopy time (FT), type of intervention, and anatomically defined target were recorded. RESULTS: Data with documented radiation doses were available for 4985 TACEs and for 2018 biliary interventions. For biliary interventions the median DAP was 2594 (interquartile range [IQR] = 1174-5858) cGycm2. For TACE, the median DAP was 11,632 [IQR = 5530-22,800] cGycm2 and significantly higher compared to biliary interventions (p < 0.0001). Biliary interventions with the highest DAP take place at the common hepatic duct; procedures with the longest FT were registered at the hepatic duct bifurcation. CONCLUSIONS: The individual radiation exposure during liver interventions is less dependent of the complexity of the procedure or the fluoroscopy time, but rather on the type of intervention and the anatomic target. The presented data can help to approximately estimate the radiation exposure in advance when planning an intervention.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Exposição à Radiação , Fluoroscopia , Humanos , Doses de Radiação , Sistema de Registros , Estudos Retrospectivos
9.
AJR Am J Roentgenol ; 210(6): 1317-1322, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29629804

RESUMO

OBJECTIVE: The aim of this study was to quantitatively assess hyaline cartilage and subchondral bone conditions in a fully preserved cadaveric human knee joint using high-resolution x-ray propagation-based phase-contrast imaging (PBI) CT and to compare the performance of the new technique with conventional CT and MRI. MATERIALS AND METHODS: A cadaveric human knee was examined using an x-ray beam of 60 keV, a detector with a 90-mm2 FOV, and a pixel size of 46 × 46 µm2. PBI CT images were reconstructed with both the filtered back projection algorithm and the equally sloped tomography method. Conventional 3-T MRI and CT were also performed. Measurements of cartilage thickness, cartilage lesions, International Cartilage Repair Society scoring, and detection of subchondral bone changes were evaluated. Visual inspection of the specimen akin to arthroscopy was conducted and served as a standard of reference for lesion detection. RESULTS: Loss of cartilage height was visible on PBI CT and MRI. Quantification of cartilage thickness showed a strong correlation between the two modalities. Cartilage lesions appeared darker than the adjacent cartilage on PBI CT. PBI CT showed similar agreement to MRI for depicting cartilage substance defects or lesions compared with the visual inspection. The assessment of subchondral bone cysts showed moderate to strong agreement between PBI CT and CT. CONCLUSION: In contrast to the standard clinical methods of MRI and CT, PBI CT is able to simultaneously depict cartilage and bony changes at high resolution. Though still an experimental technique, PBI CT is a promising high-resolution imaging method to evaluate comprehensive changes of osteoarthritic disease in a clinical setting.


Assuntos
Doenças das Cartilagens/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Algoritmos , Cadáver , Doenças das Cartilagens/patologia , Cartilagem Articular/patologia , Humanos , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos
10.
Radiology ; 283(2): 478-485, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27905865

RESUMO

Purpose To prospectively evaluate the perfusion patterns at quantitative dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging of transient bone marrow edema syndrome (TBMES) and avascular osteonecrosis. Materials and Methods Institutional review board approval and written informed consent were obtained. Thirty-two patients (21 men, 11 women; mean age, 48 years; 26 hips, 10 knees) underwent conventional MR imaging and a dynamic contrast-enhanced three-dimensional spoiled gradient-echo sequence at 3 T. Parameter maps for mean transit time (MTT) and plasma flow (PF) were evaluated qualitatively and quantitatively. Differences in perfusion patterns were analyzed by using the Fisher exact test. Regions of interest were drawn in areas of high PF and long MTT on each parametric map. Mean, median, standard deviation, minimum, and maximum values were determined. TBMES and osteonecrosis were compared statistically by using the Mann-Whitney U and Wilcoxon signed-rank tests, with a P value of less than .05 considered indicative of a significant difference. Results Nineteen joints with TBMES and 17 joints with osteonecrosis were evaluated. TBMES joints showed a subchondral elongated area of high PF and low MTT that was surrounded by an area of long MTT and low PF. Osteonecrosis joints showed a subchondral area with low or no detectable PF and MTT adjacent to the joint surface, which was surrounded by a rim of high PF and intermediate MTT. Patterns for TBMES and osteonecrosis did not overlap. A significant difference (P < .001) in PF in the immediate subchondral area was found between TBMES and osteonecrosis; in joints with osteonecrosis, this was comparable to background noise, and therefore, could not be quantified. In the circumscribed rim of high PF and intermediate MTT, which was only found in joints with osteonecrosis, mean ± standard deviation PF was 18.9 mL/100 mL per minute ± 11.0 and mean MTT was 213.3 seconds ± 56.8. No significant difference between TBMES and osteonecrosis was found for MTT (P = .09) and PF (P = .75) in the surrounding area. Conclusion Parameter maps derived at dynamic contrast-enhanced MR imaging with high temporal resolution can allow differentiation of osteonecrosis from TBMES in hip and knee joints. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Doenças da Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Osteonecrose/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Síndrome
11.
NMR Biomed ; 30(3)2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26114411

RESUMO

Diffusion-weighted MRI (DWI) of the vertebral bone marrow is a clinically important tool for the characterization of bone-marrow pathologies and, in particular, for the differentiation of benign (osteoporotic) and malignant vertebral compression fractures. DWI of the vertebral bone marrow is, however, complicated by some unique MR and tissue properties of vertebral bone marrow. Due to both the spongy microstructure of the trabecular bone and the proximity of the lungs, soft tissue, or large vessels, substantial magnetic susceptibility variations occur, which severely reduce the magnetic field homogeneity as well as the transverse relaxation time T*2 , and thus complicate MRI in particular with echoplanar imaging (EPI) techniques. Therefore, alternative diffusion-weighting pulse sequence types such as single-shot fast-spin-echo sequences or segmented EPI techniques became important alternatives for quantitative DWI of the vertebral bone marrow. This review first describes pulse sequence types that are particularly important for DWI of the vertebral bone marrow. Then, data from 24 studies that made diffusion measurements of normal vertebral bone marrow are reviewed; summarizing all results, the apparent diffusion coefficient (ADC) of normal vertebral bone marrow is typically found to be between 0.2 and 0.6 × 10-3 mm2 /s. Finally, DWI of vertebral compression fractures is discussed. Numerous studies demonstrate significantly greater ADCs in osteoporotic fractures (typically between 1.2 and 2.0 × 10-3 mm2 /s) than in malignant fractures or lesions (typically 0.7-1.3 × 10-3 mm2 /s). Alternatively, several studies used the (qualitative) image contrast of diffusion-weighted acquisitions for differentiation of lesion etiology: a very good lesion differentiation can be achieved, particularly with diffusion-weighted steady-state free precession sequences, which depict malignant lesions as hyperintense relative to normal-appearing vertebral bone marrow, in contrast to hypointense or isointense osteoporotic lesions. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Doenças da Medula Óssea/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Doenças da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Animais , Medula Óssea/patologia , Medicina Baseada em Evidências , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coluna Vertebral/patologia
12.
Int J Hyperthermia ; 32(2): 151-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26652664

RESUMO

PURPOSE: This study was designed to assess technical success and complications in patients with high-risk soft tissue sarcomas undergoing CT fluoroscopy-guided closed-tip catheter placement before treatment with combined chemotherapy and regional hyperthermia. MATERIALS AND METHODS: This retrospective study comprised all patients referred for insertion of closed-tip catheters for the introduction of thermometry probes before regional hyperthermia treatment at a single university centre from 2010 to 2015. Catheter placements were performed under local anaesthesia and intermittent CT fluoroscopy guidance. Technical success, complication rate, duration of catheter insertion and dose-length product (DLP) were analysed. Technical success was defined as intratumoural catheter placement suitable for subsequent thermometry. RESULTS: A total of 35 procedures were performed on 35 patients (22 men, 13 women). In 34 out of 35 interventions catheters were inserted successfully; in one patient catheter placement was not feasible. No intra-interventional complications occurred. In six patients post-interventional complications were observed - two major (one abscess formation and one severe catheter dislocation) and four minor complications. Technical failure was observed in 11.4% of patients, especially catheter kinking. A total of 55 catheters were placed, with a mean number of 1.7 ± 0.7 per patient. Mean total DLP was 723.2 ± 355.9 mGy*cm. CONCLUSION: CT fluoroscopy-guided closed-tip catheter placement into high-risk soft tissue sarcomas was characterised by high technical success and relatively low complication rate. While major complications were rarely observed, catheter-kinking preventing successful thermometry represented the most frequent technical failure.


Assuntos
Cateterismo/métodos , Sarcoma , Neoplasias de Tecidos Moles , Adulto , Idoso , Cateterismo/efeitos adversos , Feminino , Fluoroscopia , Humanos , Hipertermia Induzida , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sarcoma/diagnóstico por imagem , Sarcoma/terapia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/terapia , Termometria , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
Opt Express ; 23(10): 13294-308, 2015 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-26074580

RESUMO

The phase retrieval problem can be reduced to the second order partial differential equation. In order to retrieve the absolute values of the X-ray phase and to minimize the reconstruction artifacts we defined the mixed inhomogeneous boundary condition using available a priori information about the sample. Finite element technique was used to solve the boundary value problem. The approach is validated on numerical and experimental phantoms. In order to demonstrate a possible application of the method, we have processed an entire tomographic set of differential phase images and estimated the magnitude of the refractive index decrement for some tissues inside complex biomedical samples.

14.
J Comput Assist Tomogr ; 39(5): 643-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26248148

RESUMO

OBJECTIVE: To test the hypothesis that apparent diffusion coefficient (ADC) in vertebral bone marrow of benign and malignant fractures is related to the volume of the interstitial space, determined with dynamic contrast-enhanced (DCE) magnetic resonance imaging. METHODS: Patients with acute benign (n = 24) and malignant (n = 19) vertebral body fractures were examined at 1.5 T. A diffusion-weighted single-shot turbo-spin-echo sequence (b = 100 to 600 s/mm) and DCE turbo-FLASH sequence were evaluated. Regions of interest were manually selected for each fracture. Apparent diffusion coefficient was determined with a monoexponential decay model. The DCE magnetic resonance imaging concentration-time curves were analyzed using a 2-compartment tracer-kinetic model. RESULTS: Apparent diffusion coefficient showed a significant positive correlation with interstitial volume in the whole study population (Pearson r = 0.66, P < 0.001), as well as in the malignant (Pearson r = 0.64, P = 0.004) and benign (Pearson r = 0.52, P = 0.01) subgroup. A significant correlation between ADC and the permeability-surface area product could be observed when analyzing the whole study population (Spearman rs = 0.40, P = 0.008), but not when separately examining the subgroups. Plasma flow showed a significant correlation with ADC in benign fractures (Pearson r = 0.23, P = 0.03). Plasma volume did not show significant correlations with ADC. CONCLUSIONS: The results support the hypothesis that the ADC of a lesion is inversely correlated to its cellularity. This explains previous observations that ADC is reduced in more malignant lesions.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fraturas da Coluna Vertebral/patologia , Neoplasias da Coluna Vertebral/patologia , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/etiologia , Neoplasias da Coluna Vertebral/complicações , Coluna Vertebral/patologia , Adulto Jovem
16.
AJR Am J Roentgenol ; 203(3): 582-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25148160

RESUMO

OBJECTIVE: The purpose of our study was to determine the optimum combination of b values for calculating the apparent diffusion coefficient (ADC) using a diffusion-weighted (DW) single-shot turbo spin-echo (TSE) sequence in the differentiation between acute benign and malignant vertebral body fractures. SUBJECTS AND METHODS: Twenty-six patients with osteoporotic (mean age, 69 years; range, 31.5-86.2 years) and 20 patients with malignant vertebral fractures (mean age, 63.4 years; range, 24.7-86.4 years) were studied. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW single-shot TSE sequence at different b values (100, 250, 400, and 600 s/mm(2)) was applied. On the DW images for each evaluated fracture, an ROI was manually adapted to the area of hyperintense signal intensity on STIR-hypointense signal on T1-weighted images. For each ROI, nine different combinations of two, three, and four b values were used to calculate the ADC using a least-squares algorithm. The Student t test and Mann-Whitney U test were used to determine significant differences between benign and malignant fractures. An ROC analysis and the Youden index were used to determine cutoff values for assessment of the highest sensitivity and specificity for the different ADC values. The positive (PPV) and negative predictive values (NPV) were also determined. RESULTS: All calculated ADCs (except the combination of b = 400 s/mm(2) and b = 600 s/mm(2)) showed statistically significant differences between benign and malignant vertebral body fractures, with benign fractures having higher ADCs than malignant ones. The use of higher b values resulted in lower ADCs than those calculated with low b values. The highest AUC (0.85) showed the ADCs calculated with b = 100 and 400 s/mm(2), and the second highest AUC (0.829) showed the ADCs calculated with b = 100, 250, and 400 s/mm(2). The Youden index with equal weight given to sensitivity and specificity suggests use of an ADC calculated with b = 100, 250, and 400 s/mm(2) (cutoff ADC, < 1.7 × 10(-3) mm(2)/s) to best diagnose malignancy (sensitivity, 85%; specificity, 84.6%; PPV, 81.0%; NPV, 88.0%). CONCLUSION: ADCs calculated with a combination of low to intermediate b values (b = 100, 250, and 400 s/mm(2)) provide the best diagnostic performance of a DW single-shot TSE sequence to differentiate acute benign and malignant vertebral body fractures.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fraturas por Osteoporose/patologia , Fraturas da Coluna Vertebral/patologia , Neoplasias da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/patologia , Adulto , Idoso , Algoritmos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/etiologia , Adulto Jovem
17.
AJR Am J Roentgenol ; 200(6): W635-43, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23701095

RESUMO

OBJECTIVE: The objective of our study was to evaluate quantitative dynamic contrast-enhanced MRI (DCE-MRI) based on tracer kinetic modeling of perfusion in the differentiation of benign from malignant vertebral fractures. SUBJECTS AND METHODS: Patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years) and patients with 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years) underwent dynamic contrast-enhanced MRI. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. Dynamic contrast-enhanced image sets were acquired with a 2D saturation-recovery spoiled gradient-echo sequence. Regions of interest in parameter maps of mean transit time (MTT) and plasma flow in the fractured vertebral bodies were analyzed with a two-compartment tracer kinetic model. Plasma flow, plasma volume (PV), extraction flow, and interstitial volume were calculated. The forward volume transfer constant (K(trans)) and the extracellular volume (ECV) were derived. A two-tailed Fisher exact test, Mann-Whitney U test, and receiver operating characteristic analysis were performed. RESULTS: Forty-four vertebral fractures in 44 patients could be evaluated. In spots of increased plasma flow, interstitial volume (p = 0.0003), ECV (p = 0.002), and extraction flow (p = 0.03) for osteoporotic and malignant vertebral fractures were significantly different. The mean interstitial volume was 28.62 mL/100 mL for osteoporotic fractures and 11.73 mL/100 mL for malignant fractures, and the area under the curve (AUC) was 0.819 for a cutoff of 11.72 mL/100 mL or less indicating malignancy (sensitivity, 63.2%; specificity, 96.0%). The mean ECV was 52.68 mL/100 mL for osteoporotic fractures and 36.71 mL/100 mL for malignant fractures, and the AUC was 0.802 for a cutoff of 35.83 mL/100 mL or less indicating malignancy (sensitivity, 63.2%; specificity, 92.0%). The mean extraction flow was 15.19 mL/100 mL/min for osteoporotic fractures and 23.67 mL/100 mL/min for malignant fractures, and the AUC was 0.693 for a cutoff of 6.52 mL/100 mL/min or less indicating malignancy (sensitivity, 57.9%; specificity, 92.0%). K(trans), plasma flow, and PV in the spots of increased plasma flow and all quantitative perfusion parameters in the regions of increased MTT did not show any significant differences between benign and malignant fractures. CONCLUSION: In spots of high plasma flow, which can be determined with a deconvolution analysis, the quantitative perfusion parameters of interstitial volume, ECV, and extraction flow are significantly different between acute osteoporotic and malignant vertebral fractures and can aid in the distinction between the two entities.


Assuntos
Imageamento por Ressonância Magnética/métodos , Fraturas por Osteoporose/diagnóstico , Fraturas da Coluna Vertebral/diagnóstico , Neoplasias da Coluna Vertebral/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/patologia , Curva ROC , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/patologia , Neoplasias da Coluna Vertebral/patologia , Estatísticas não Paramétricas
18.
CVIR Endovasc ; 6(1): 6, 2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36795179

RESUMO

BACKGROUND: Besides other factors, complication rate of transarterial interventions depends on the size of the vascular access. Therefore, the vascular access is mostly chosen as small as possible while still allowing all planned parts of the intervention. This retrospective analysis is to evaluate the safety and feasibility of sheathless arterial interventions for a broad spectrum of interventions in daily practice. METHODS: All sheathless interventions using a 4 F main catheter between May 2018 and September 2021 were included in the evaluation. Additionally, intervention parameters such as type of catheter, use of microcatheter and required change of main catheters were assessed. Information about the use about sheathless approach and catheters were obtained from the material registration system. All catheters were braided. RESULTS: 503 sheathless interventions with 4 F catheters from the groin were documented. The spectrum comprised bleeding embolization, diagnostic angiographies, arterial DOTA-TATE-therapy, uterine fibroid embolization, transarterial chemotherapy, transarterial radioembolization and others. In 31 cases (6 %) a change of the main catheter was required. In 381 cases (76 %) a microcatheter was utilized. No clinically relevant adverse events were observed (grade 2 or higher [CIRSE AE-classification]). None of the cases later required conversion to a sheath-based intervention. CONCLUSIONS: Sheathless interventions with a 4 F braided catheter from the groin are safe and feasible. It allows for a broad spectrum of interventions in daily practice.

19.
AJR Am J Roentgenol ; 199(5): 1083-92, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23096183

RESUMO

OBJECTIVE: The objective of our study was to compare the diagnostic value of qualitative diffusion-weighted imaging (DWI), quantitative DWI, and chemical-shift imaging in a single prospective cohort of patients with acute osteoporotic and malignant vertebral fractures. SUBJECTS AND METHODS: The study group was composed of patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years; age range, 31 years 6 months to 86 years 2 months) and 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years; age range, 24 years 8 months to 86 years 4 months). T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW reverse fast imaging with steady-state free precession (PSIF) sequence at different delta values was evaluated qualitatively. A DW echo-planar imaging (EPI) sequence and a DW single-shot turbo spin-echo (TSE) sequence at different b values were evaluated qualitatively and quantitatively using the apparent diffusion coefficient. Opposed-phase sequences were used to assess signal intensity qualitatively. The signal loss between in- and opposed-phase images was determined quantitatively. Two-tailed Fisher exact test, Mann-Whitney test, and receiver operating characteristic analysis were performed. Sensitivities, specificities, and accuracies were determined. RESULTS: Qualitative DW-PSIF imaging (delta = 3 ms) showed the best performance for distinguishing between benign and malignant fractures (sensitivity, 100%; specificity, 88.5%; accuracy, 93.5%). Qualitative DW-EPI (b = 50 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.50]) and DW single-shot TSE imaging (b = 100 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.18]; b = 400 s/mm(2) [p = 0.18]; b = 600 s/mm(2) [p = 0.39]) did not indicate significant differences between benign and malignant fractures. DW-EPI using a b value of 500 s/mm(2) (p = 0.01) indicated significant differences between benign and malignant vertebral fractures. Quantitative DW-EPI (p = 0.09) and qualitative opposed-phase imaging (p = 0.06) did not exhibit significant differences, quantitative DW single-shot TSE imaging (p = 0.002) and quantitative chemical-shift imaging (p = 0.01) showed significant differences between benign and malignant fractures. CONCLUSION: The DW-PSIF sequence (delta = 3 ms) had the highest accuracy in differentiating benign from malignant vertebral fractures. Quantitative chemical-shift imaging and quantitative DW single-shot TSE imaging had a lower accuracy than DW-PSIF imaging because of a large overlap. Qualitative assessment of opposed-phase, DW-EPI, and DW single-shot TSE sequences and quantitative assessment of the DW-EPI sequence were not suitable for distinguishing between benign and malignant vertebral fractures.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Osteoporose/complicações , Fraturas da Coluna Vertebral/diagnóstico , Fraturas da Coluna Vertebral/etiologia , Neoplasias da Coluna Vertebral/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diagnóstico Diferencial , Imagem Ecoplanar , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído , Fraturas da Coluna Vertebral/patologia , Neoplasias da Coluna Vertebral/secundário , Estatísticas não Paramétricas
20.
PLoS One ; 16(10): e0259127, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34699565

RESUMO

INTRODUCTION: Port implantations at the forearm are associated with an increased risk of relevant vein thrombosis. Therefore, with this study we sought to identify the responsible risk factors to improve technical quality of the method. METHODS: This is a retrospective analysis of 313 patients with port implantation at the forearm in 2019. Then, exploratory statistics were conducted comprising Cox-Regression and Kaplan-Meier-Analyses. RESULTS: Mean age was 60 ± 14 years. 232 (74%) of the patients were female. No early infection was observed. 29 late infections and 57 cases of thrombosis occurred. In only 9% of the patients with thrombosis hospital admission was necessary for treatment. Median interval to the diagnosis of thrombosis was 23 days; inter-quartile-range: 16-75. Mean interval to elective port explantation was 227 ± 128 days. There was no effect of occurrence of thrombosis of the interventionalist, the assistance nor of several technical aspects. However, there was a significantly lower risk of thrombosis for primary implanted port system compared to replacement ports, Hazard-ratio: 0.34 [Confidence interval: 0.172, 0.674], p = 0.002. Age was a significant risk factor for late infections, Hazard-ratio: 3.35 [Confidence interval:1.84, 6.07], p < 0.0001. CONCLUSION: The main risk factor for adverse outcome after radiographically guided port implantation at the forearm is the type of the implanted port system. The reason for that might not be the material itself but the experience of a team with a certain port system. Age is a risk factor for late complications.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Antebraço/irrigação sanguínea , Trombose Venosa/etiologia , Idoso , Cateterismo Venoso Central/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA