Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 627(8005): 783-788, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38538937

RESUMO

Controlling the intensity of emitted light and charge current is the basis of transferring and processing information1. By contrast, robust information storage and magnetic random-access memories are implemented using the spin of the carrier and the associated magnetization in ferromagnets2. The missing link between the respective disciplines of photonics, electronics and spintronics is to modulate the circular polarization of the emitted light, rather than its intensity, by electrically controlled magnetization. Here we demonstrate that this missing link is established at room temperature and zero applied magnetic field in light-emitting diodes2-7, through the transfer of angular momentum between photons, electrons and ferromagnets. With spin-orbit torque8-11, a charge current generates also a spin current to electrically switch the magnetization. This switching determines the spin orientation of injected carriers into semiconductors, in which the transfer of angular momentum from the electron spin to photon controls the circular polarization of the emitted light2. The spin-photon conversion with the nonvolatile control of magnetization opens paths to seamlessly integrate information transfer, processing and storage. Our results provide substantial advances towards electrically controlled ultrafast modulation of circular polarization and spin injection with magnetization dynamics for the next-generation information and communication technology12, including space-light data transfer. The same operating principle in scaled-down structures or using two-dimensional materials will enable transformative opportunities for quantum information processing with spin-controlled single-photon sources, as well as for implementing spin-dependent time-resolved spectroscopies.

3.
Nano Lett ; 24(9): 2743-2750, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38393986

RESUMO

For energy-efficient magnetic memories, switching of perpendicular magnetization by spin-orbit torque (SOT) appears to be a promising solution. This SOT switching requires the assistance of an in-plane magnetic field to break the symmetry. Here, we demonstrate the field-free SOT switching of a perpendicularly magnetized thulium iron garnet (Tm3Fe5O12, TmIG). The polarity of the switching loops, clockwise or counterclockwise, is determined by the direction of the initial current pulses, in contrast with field-assisted switching where the polarity is controlled by the direction of the magnetic field. From Brillouin light scattering, we determined the Dzyaloshinskii-Moriya interaction (DMI) induced by the Pt-TmIG interface. We will discuss the possible origins of field-free switching and the roles of the interfacial DMI and cubic magnetic anisotropy of TmIG. This discussion is substantiated by magnetotransport, Kerr microscopy, and micromagnetic simulations. Our observation of field-free electrical switching of a magnetic insulator is an important milestone for low-power spintronic devices.

4.
Opt Lett ; 49(11): 3010-3013, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824315

RESUMO

We report the enhancement of spin injection efficiency in an external-cavity VCSEL based on a non-resonant pumping coupled with a polarized optical resonant illumination. This double pumping scheme allows both the injection of spin polarized electrons in the conduction band and the selection of the spin orientation for the electron/hole recombination laser process. Experimentally, a flip of the polarization state of the laser is achieved with an ellipticity of +31° (spin down) and -33° (spin up), so an increase of about 50% of the ellipticity is achieved in comparison to an optical non-resonant pumping alone.

5.
Nano Lett ; 23(15): 6785-6791, 2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37524333

RESUMO

The hallmark of spintronics has been the ability of spin-orbit interactions to convert a charge current into a spin current and vice versa, mainly in the bulk of heavy metal thin films. Here, we demonstrate how a light metal interface profoundly affects both the nature of spin-orbit torques and its efficiency in terms of damping-like (HDL) and field-like (HFL) effective fields in ultrathin Co films. We measure unexpectedly HFL/HDL ratios much larger than 1 by inserting a nanometer-thin Al metallic layer in Pt|Co|Al|Pt as compared to a similar stacking, including Cu as a reference. From our modeling, these results evidence the existence of large Rashba interaction at the Co|Al interface generating a giant HFL, which is not expected from a metallic interface. The occurrence of such enhanced torques from an interfacial origin is further validated by demonstrating current-induced magnetization reversal showing a significant decrease of the critical current for switching.

6.
Endocr Pract ; 29(7): 553-559, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37080298

RESUMO

OBJECTIVE: Autoantibodies against the thyrotropin receptor (TSH-R-Ab) are key mediators for the pathogenesis of Graves' disease (GD). TSH-R-Ab degradation was evaluated using several immunoassays within an exploratory, controlled trial in patients with GD receiving a monoclonal antibody (mAb) targeting the neonatal crystallizable fragment receptor (FcRn). METHODS: Serial measurements of TSH-R-Ab serum levels were performed using 3 different binding and cell-based assays in patients with GD either on medication or on placebo. RESULTS: In contrast to the placebo group, in which no changes were observed, a 12-week mAb therapy led to an early and significant decrease (>60%) in the serum TSH-R-Ab levels in patients with thyroidal and extrathyroidal GD, as unanimously shown in all 3 assays. These marked changes were noted already at week 7 post baseline (P <.0001 for the binding immunoassay and for the luciferase (readout) bioassay). The 3 TSH-R-Ab binding and bioassays were highly correlated in the samples of both study groups (binding immunoassay vs luciferase bioassay, r =.91, P <.001, binding vs cyclic adenosine monophosphate (cAMP) bioassay, r = 0.86, P <.001, and luciferase vs cAMP bioassay, r = 0.71, P =.006). The serological results correlated with the course of the extrathyroidal clinical parameters of GD, that is, clinical activity score and proptosis. CONCLUSION: Targeting the FcRn markedly reduces the disease-specific TSH-R-Ab in patients with GD. The novel and rapid TSH-R-Ab bioassay improves diagnosis and management of patients with GD.


Assuntos
Doença de Graves , Estimulador Tireóideo de Ação Prolongada , Humanos , Recém-Nascido , Anticorpos Monoclonais/uso terapêutico , Autoanticorpos , Doença de Graves/tratamento farmacológico , Doença de Graves/diagnóstico , Imunoglobulinas Estimuladoras da Glândula Tireoide , Estimulador Tireóideo de Ação Prolongada/uso terapêutico , Receptores da Tireotropina , Tireotropina
7.
Nano Lett ; 19(1): 90-99, 2019 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-30472859

RESUMO

Due to the difficulty of growing high-quality semiconductors on ferromagnetic metals, the study of spin diffusion transport in Si was limited to lateral geometry devices. In this work, by using an ultrahigh-vacuum wafer-bonding technique, we have successfully fabricated metal-semiconductor-metal CoFeB/MgO/Si/Pt vertical structures. We hereby demonstrate pure spin-current injection and transport in the perpendicular current flow geometry over a distance larger than 2 µm in n-type Si at room temperature. In those experiments, a pure propagating spin current is generated via ferromagnetic resonance spin pumping and converted into a measurable voltage by using the inverse spin Hall effect occurring in the top Pt layer. A systematic study varying both Si and MgO thicknesses reveals the important role played by the localized states at the MgO-Si interface for the spin-current generation. Proximity effects involving indirect exchange interactions between the ferromagnet and the MgO-Si interface states appears to be a prerequisite to establishing the necessary out-of-equilibrium spin population in Si under the spin-pumping action.

8.
Nano Lett ; 18(4): 2381-2386, 2018 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-29517243

RESUMO

The emission of circularly polarized light from a single quantum dot relies on the injection of carriers with well-defined spin polarization. Here we demonstrate single dot electroluminescence (EL) with a circular polarization degree up to 35% at zero applied magnetic field. The injection of spin-polarized electrons is achieved by combining ultrathin CoFeB electrodes on top of a spin-LED device with p-type InGaAs quantum dots in the active region. We measure an Overhauser shift of several microelectronvolts at zero magnetic field for the positively charged exciton (trion X+) EL emission, which changes sign as we reverse the injected electron spin orientation. This is a signature of dynamic polarization of the nuclear spins in the quantum dot induced by the hyperfine interaction with the electrically injected electron spin. This study paves the way for electrical control of nuclear spin polarization in a single quantum dot without any external magnetic field.

9.
Opt Express ; 26(6): 6739-6757, 2018 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-29609363

RESUMO

A new vectorial model (VSPIN) based on the Jones formalism is proposed to describe the polarization dynamics of spin injected V(e)CSELs. This general modelling framework accounts for spin injection effects as a gain circular dichroism in the active medium and provides guidelines for developing functional spin-controlled lasers. We investigate the detrimental role of phase anisotropy on polarization switching and show that it can be overcome by preparing the laser cavity to achieve efficient polarization switching under low effective spin injection. The VSPIN model predictions have been confirmed experimentally and explain the polarization behavior of spin-VCSELs reported in the literature.

10.
Opt Lett ; 42(3): 651-654, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28146550

RESUMO

We report on the compensation of the linear anisotropy of phase in a vertical-external-cavity surface-emitting laser from 21 to 0.5 mrad with an intracavity PLZT electro-optical ceramic. It allows dynamic and accurate control of the laser linear anisotropy, as well as dynamic control of the laser polarization eigenstates. At the birefringence compensation point, we observe an elliptical polarization state with 41° of ellipticity, rotated from its initial position of 32°. The experimental observations are in close agreement with the theoretical predictions. Finally, we are able to demonstrate control of the polarization state with spin injection.

11.
Opt Express ; 23(8): 9573-88, 2015 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-25968994

RESUMO

In this paper we report birefringence measurements of an optically pumped (100)-oriented InGaAs/GaAsP multiple quantum well (MQWs) Vertical External Cavity Surface Emitting Laser (VECSEL) in oscillating conditions. The proposed technique relies on the measurement in the microwave domain of the beatnote between the oscillating mode and the amplified spontaneous emission of the cross-polarized non-lasing field lying in the following longitudinal mode. This technique is shown to offer extremely high sensitivity and accuracy enabling to track the amount of residual birefringence according to the laser operation conditions. The experience fits within the broader framework of polarization selection in spin-injected lasers.

12.
Adv Mater ; 36(14): e2304243, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38160244

RESUMO

2D materials, such as transition metal dichalcogenides, are ideal platforms for spin-to-charge conversion (SCC) as they possess strong spin-orbit coupling (SOC), reduced dimensionality and crystal symmetries as well as tuneable band structure, compared to metallic structures. Moreover, SCC can be tuned with the number of layers, electric field, or strain. Here, SCC in epitaxially grown 2D PtSe2 by THz spintronic emission is studied since its 1T crystal symmetry and strong SOC favor SCC. High quality of as-grown PtSe2 layers is demonstrated, followed by in situ ferromagnet deposition by sputtering that leaves the PtSe2 unaffected, resulting in well-defined clean interfaces as evidenced with extensive characterization. Through this atomic growth control and using THz spintronic emission, the unique thickness-dependent electronic structure of PtSe2 allows the control of SCC. Indeed, the transition from the inverse Rashba-Edelstein effect (IREE) in 1-3 monolayers (ML) to the inverse spin Hall effect (ISHE) in multilayers (>3 ML) of PtSe2 enabling the extraction of the perpendicular spin diffusion length and relative strength of IREE and ISHE is demonstrated. This band structure flexibility makes PtSe2 an ideal candidate to explore the underlying mechanisms and engineering of the SCC as well as for the development of tuneable THz spintronic emitters.

13.
Front Med (Lausanne) ; 10: 1296486, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38298513

RESUMO

Introduction: Lyme borreliosis (LB) is the most common vector disease in temperate countries of the northern hemisphere. It is caused by Borrelia burgdorferi sensu lato complex. Methods: To study the case presentation of LB in France, we contacted about 700 physicians every year between 2003 and 2011. An anonymous questionnaire was established allowing the collection of 3,509 cases. The information collected was imported or directly entered into databases and allowed identifying variables that were validated in a multiple correspondence analysis (MCA). Results: Sixty percent of the cases were confirmed, 10% were probable, 13.5% doubtful, 10.2% asymptomatic seropositive and 6.3% were negative. The clinical manifestations reported were cutaneous (63%), neurological (26%), articular (7%), ocular (1.9%) and cardiac (1.3%). Almost all patients were treated. When focusing more particularly on confirmed cases, our studies confirm that children have a distinct clinical presentation from adults. There is a gender effect on clinical presentation, with females presenting more often with erythema migrans or acrodermatitis chronica atrophicans than males, while males present more often with neurological signs or arthritis than females. Discussion: This is the first time that a comprehensive study of suspected Lyme borreliosis cases has been conducted over several years in France. Although we were not able to follow the clinical course of patients after treatment, these results suggest the interest of refining the questionnaire and of following up a cohort of patients over a sufficiently long period to obtain more information on their fate according to different parameters.

14.
Eur J Endocrinol ; 188(4): K24-K28, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-36995895

RESUMO

Women of subfertile couples with thyroid autoimmunity (TAI) have an increased risk of miscarriage when pregnant after an assisted reproductive technology (ART) treatment. This might amongst others be due to the presence of thyrotropin receptor antibodies (TSH-R-Ab) that can impede the development of the corpus luteum. TSH-R-Ab can be present in women with TAI and/or be induced by the ovarian stimulation procedure (OS) that is performed to initiate the ART. In this prospective pilot study, we determined the presence of both binding and functional TSH-R-Ab (stimulating or blocking) with five different assays before and after OS in ten women (eleven cycles) with TAI of subfertile couples and in one woman without TAI. Mean (SD) age was 38.8 (±3.2) years, median (range) cumulative OS dose 1413 (613-2925) IU/L. Median baseline serum levels of thyrotropin, free thyroxine, and thyro-peroxidase antibodies were 2.33 (2.23-2.61) mIU/L, 16.8 (14.4-18.5) pmol/L and 152 (86-326) kIU/L, respectively. Oestradiol levels increased during OS from 40 (26-56) ng/L to 963 (383-5095) ng/L; P < .01. TSH-R-Ab measurements in all subject samples were below the cut-off of the corresponding immunoassay and four bioassays before or after OS.


Assuntos
Estimulador Tireóideo de Ação Prolongada , Glândula Tireoide , Gravidez , Feminino , Humanos , Glândula Tireoide/fisiologia , Autoimunidade , Estudos Prospectivos , Projetos Piloto , Tireotropina , Indução da Ovulação , Autoanticorpos , Tiroxina
15.
ACS Appl Mater Interfaces ; 15(32): 38592-38602, 2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37550946

RESUMO

Disordered topological insulator (TI) films have gained intense interest by benefiting from both the TI's exotic transport properties and the advantage of mass production by sputtering. Here, we report on the clear evidence of spin-charge conversion (SCC) in amorphous Gd-alloyed BixSe1-x (BSG)/CoFeB bilayers fabricated by sputtering, which could be related to the amorphous TI surface states. Two methods have been employed to study SCC in BSG (tBSG = 6-16 nm)/CoFeB(5 nm) bilayers with different BSG thicknesses. First, spin pumping is used to generate a spin current in CoFeB and detect SCC by the inverse Edelstein effect (IEE). The maximum SCC efficiency (SCE) is measured to be as large as 0.035 nm (IEE length λIEE) in a 6 nm thick BSG sample, which shows a strong decay when tBSG increases due to the increase of BSG surface roughness. The second method is THz time-domain spectroscopy, which reveals a small tBSG dependence of SCE, validating the occurrence of a pure interface state-related SCC. Furthermore, our angle-resolved photoemission spectroscopy data show dispersive two-dimensional surface states that cross the bulk gap until the Fermi level, strengthening the possibility of SCC due to the amorphous TI states. Our studies provide a new experimental direction toward the search for topological systems in amorphous solids.

16.
Eur J Nucl Med Mol Imaging ; 39(1): 188-97, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22089660

RESUMO

PURPOSE: Multi-centre trials are an important part of proving the efficacy of procedures, drugs and interventions. Imaging components in such trials are becoming increasingly common; however, without sufficient control measures the usefulness of these data can be compromised. This paper describes a framework for performing high-quality multi-centre trials with single photon emission computed tomography (SPECT), using a pan-European initiative to acquire a normal control dopamine transporter brain scan database as an example. METHODS: A framework to produce high-quality and consistent SPECT imaging data was based on three key areas: quality assurance, the imaging protocol and system characterisation. Quality assurance was important to ensure that the quality of the equipment and local techniques was good and consistently high; system characterisation helped understand and where possible match the performance of the systems involved, whereas the imaging protocol was designed to allow a degree of flexibility to best match the characteristics of each imaging device. RESULTS: A total of 24 cameras on 15 sites from 8 different manufacturers were evaluated for inclusion in our multi-centre initiative. All results matched the required level of specification and each had their performance characterised. Differences in performance were found between different system types and cameras of the same type. Imaging protocols for each site were modified to match their individual characteristics to produce comparable high-quality SPECT images. CONCLUSION: A framework has been designed to produce high-quality data for multi-centre SPECT studies. This framework has been successfully applied to a pan-European initiative to acquire a healthy control dopamine transporter image database.


Assuntos
Ensaios Clínicos como Assunto/normas , Bases de Dados Factuais , Estudos Multicêntricos como Assunto/normas , Medicina Nuclear , Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Europa (Continente) , Humanos , Controle de Qualidade , Padrões de Referência
17.
Artigo em Inglês | MEDLINE | ID: mdl-22262287

RESUMO

PURPOSE: To assess lymph node invasion through the use of sentinel lymph node biopsy (SLNB) in conjunctival and eyelid tumor patients and ascertain the impact of this technique in therapeutic management recommended by the multidisciplinary consensus committee. METHODS: A single center prospective nonrandomized clinical study was conducted between January 2008 and January 2010. Seventeen patients were included: 4 (2 conjunctiva and 2 eyelid) melanomas, 4 eyelid Merkel cell tumors, 8 (2 conjunctiva, 2 eyelid, 2 eyelid and conjunctiva, 2 cornea and conjunctiva) squamous cell tumors, and 1 eyelid meibomian carcinoma. Preoperative lymphoscintigraphy was done the day before surgery to label lymph node(s). The surgical biopsy was then performed along with an extemporaneous pathological examination followed by secondary complete lymph node dissection only in instances of positive histology. RESULTS: In all cases, one or more sentinel lymph nodes were identified (3-13). Two biopsies (1 Merkel cell carcinoma and 1 squamous cell carcinoma) revealed neoplastic invasion and led to complete cervical node dissection. Adjunct regional treatment was indicated for 1 melanoma, for 4 Merkel cell tumors, and for 2 squamous cell carcinomas. One false negative result was noted in the group of squamous cell carcinomas after 6 months, and it was treated. No relapse or death was observed for the other 16 patients. The mean overall follow-up was 18.2 months. CONCLUSION: As in previous studies, we found that SLNB for eyelid and conjunctival tumors is safe and effective in identifying microscopically positive SLNs. This procedure may also revive interest in the study of cervicofacial lymphatic drainage. Our current investigation is to be expanded and extended to other medical teams.


Assuntos
Carcinoma/patologia , Carcinoma/secundário , Neoplasias da Túnica Conjuntiva/patologia , Neoplasias Palpebrais/patologia , Linfonodos/patologia , Melanoma/secundário , Biópsia de Linfonodo Sentinela , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Estudos Prospectivos
18.
Eur J Nucl Med Mol Imaging ; 38(8): 1529-40, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21468761

RESUMO

PURPOSE: A joint initiative of the European Association of Nuclear Medicine (EANM) Neuroimaging Committee and EANM Research Ltd. aimed to generate a European database of [(123)I]FP-CIT single photon emission computed tomography (SPECT) scans of healthy controls. This study describes the characterization and harmonization of the imaging equipment of the institutions involved. METHODS: (123)I SPECT images of a striatal phantom filled with striatal to background ratios between 10:1 and 1:1 were acquired on all the gamma cameras with absolute ratios measured from aliquots. The images were reconstructed by a core lab using ordered subset expectation maximization (OSEM) without corrections (NC), with attenuation correction only (AC) and additional scatter and septal penetration correction (ACSC) using the triple energy window method. A quantitative parameter, the simulated specific binding ratio (sSBR), was measured using the "Southampton" methodology that accounts for the partial volume effect and compared against the actual values obtained from the aliquots. Camera-specific recovery coefficients were derived from linear regression and the error of the measurements was evaluated using the coefficient of variation (COV). RESULTS: The relationship between measured and actual sSBRs was linear across all systems. Variability was observed between different manufacturers and, to a lesser extent, between cameras of the same type. The NC and AC measurements were found to underestimate systematically the actual sSBRs, while the ACSC measurements resulted in recovery coefficients close to 100% for all cameras (AC range 69-89%, ACSC range 87-116%). The COV improved from 46% (NC) to 32% (AC) and to 14% (ACSC) (p < 0.001). CONCLUSION: A satisfactory linear response was observed across all cameras. Quantitative measurements depend upon the characteristics of the SPECT systems and their calibration is a necessary prerequisite for data pooling. Together with accounting for partial volume, the correction for scatter and septal penetration is essential for accurate quantification.


Assuntos
Bases de Dados Factuais , Câmaras gama/normas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tropanos , Calibragem , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Europa (Continente) , Humanos , Padrões de Referência
19.
ACS Appl Mater Interfaces ; 13(27): 32579-32589, 2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34196522

RESUMO

A perpendicularly magnetized spin injector with a high Curie temperature is a prerequisite for developing spin optoelectronic devices on two-dimensional (2D) materials working at room temperature (RT) with zero applied magnetic field. Here, we report the growth of Ta/CoFeB/MgO structures with large perpendicular magnetic anisotropy (PMA) on full-coverage monolayer (ML) molybdenum disulfide (MoS2). A large perpendicular interface anisotropy energy of 0.975 mJ/m2 has been obtained at the CoFeB/MgO interface, comparable to that observed in magnetic tunnel junction systems. It is found that the insertion of MgO between the ferromagnetic (FM) metal and the 2D material can effectively prevent the diffusion of the FM atoms into the 2D material. Moreover, the MoS2 ML favors a MgO(001) texture and plays a critical role in establishing the large PMA. First-principles calculations on a similar Fe/MgO/MoS2 structure reveal that the MgO thickness can modify the MoS2 band structure, from a direct band gap with 3ML-MgO to an indirect band gap with 7 ML-MgO. The proximity effect induced by Fe results in splitting of 10 meV in the valence band at the Γ point for the 3ML-MgO structure, while it is negligible for the 7 ML-MgO structure. These results pave the way to develop RT spin optoelectronic devices based on 2D transition-metal dichalcogenide materials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA