Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 23(1): 70, 2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36797684

RESUMO

BACKGROUND: The Argus II Retinal Prosthesis System (Second Sight Medical Products, Sylmar, California) is an epiretinal prosthesis that serves to provide useful vision to people who are affected by retinal degenerative diseases such as retinitis pigmentosa (RP). The purpose of this study was to analyze postoperative movement of the electrode array. METHODS: Five patients diagnosed with profound retinal dystrophy who have undergone implantation of retinal prosthesis at Stony Brook University Hospital. Fundoscopy was performed at postoperative month 1 (M1), month 3 (M3), month 6 (M6), month 12 (M12), and month 24 (M24) visits. Fundoscopy was extracted and analyzed via NIH ImageJ. Data analysis was completed using IBM SPSS. Various lengths and angles were measured each postoperative month using ImageJ. RESULTS: There was no significant change in distance between the optic disc and the surgical handle (length AB) over the two-year span (F = 0.196, p = 0.705). There was a significant change in distance of length AB over time between patients between M3 and M6 (p = 0.025). A repeated measures ANOVA revealed that there was statistically significant change of the optic disc-tack-surgical handle angle (𝛾) (M1 to M24) (F = 3.527, p = 0.030). There was no significant change in angle 𝜟 (the angle to the horizontal of the image), angle 𝜶 (tack-optic disc-surgical handle), and angle 𝜷 (optic-disc-surgical handle-tack). CONCLUSION: Our results demonstrate that there may be postoperative movement of the retinal prosthesis over time, as a statistically significant downward rotation is reported over the 2 years span. It is important, moving forward, to further study this movement and to take into consideration such movement when designing retinal implants. It is important to note that this study is limited by the small sample size, and therefore, the conclusions drawn are limited.


Assuntos
Distrofias Retinianas , Retinose Pigmentar , Próteses Visuais , Humanos , Retinose Pigmentar/cirurgia , Retina/cirurgia , Implantação de Prótese/métodos
2.
BMC Ophthalmol ; 20(1): 366, 2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32943044

RESUMO

BACKGROUND: Post-implantation visual outcomes in patients with the Argus II Retinal Prosthesis is dependent on a multitude of factors including the positioning of the electrode array on the retina. The purpose of this study is to determine whether the average electrode array-retina gap distance correlates with objective visual function outcomes and sensitivity detection thresholds in patients implanted with the Argus II Retinal Prosthesis. METHODS: Five patients with implantation of the Argus II Retinal Prosthesis were enrolled in this single-institution retrospective study. Patient demographics were collected from medical records. Visual function data (Square Localization [SL] and Direction of Motion [DOM]) and Optical Coherence Tomography (Cirrus HD-OCT) images were extracted retrospectively from the Argus II Retinal Prosthesis Post-Approval study. Visual function tests were performed with the device OFF and ON at each study visit. Electrode array-retina gap distances were measured at each of the array's 60 electrodes using the Cirrus HD-OCT software in both the nasotemporal and superoinferior planes. Data was obtained at baseline, and post-operative month 1, month 3, month 6, and year 1. Sensitivity detection thresholds were obtained at the initial programming visit and each reprogramming session. RESULTS: Three patients performed significantly better in SL visual function testing with the device ON. Patients that worsened in visual function testing with the device ON in both SL and DOM testing had a statistically significant decrease in performance. The electrode array-retina gap distance was found to effect performance in SL testing in a patient-dependent manner. No effect was found between the electrode-array gap distance and DOM testing or sensitivity detection threshold. CONCLUSION: Our results demonstrate that the electrode array-retina gap distance may affect visual function outcomes in SL testing in certain patients with the Argus II Retinal Prosthesis, and the direction and magnitude of this effect is likely patient-dependent. Furthermore, complete apposition between the electrode array and retina may not always be necessary to achieve optimal visual outcomes.


Assuntos
Retinose Pigmentar , Próteses Visuais , Eletrodos Implantados , Humanos , Implantação de Prótese , Retina/diagnóstico por imagem , Retina/cirurgia , Retinose Pigmentar/cirurgia , Estudos Retrospectivos
3.
ACG Case Rep J ; 9(5): e00773, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35558640

RESUMO

We describe a case of an inverted Meckel's diverticulum presenting as an intraluminal subepithelial lesion on intraoperative enteroscopy. A 53-year-old woman presented with chronic iron deficiency anemia unresponsive to escalating iron supplementation. After equivocal upper and lower endoscopy and negative cross-sectional imaging, capsule endoscopy suggested a submucosal mass lesion in the proximal ileum. Antegrade double-balloon enteroscopy was unsuccessful in reaching the lesion. A large pedunculated, submucosal-appearing lesion was finally identified on intraoperative enteroscopy. The mass was surgically resected, and final pathology confirmed an inverted Meckel's diverticulum.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA