Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 33(21): 1623-1634, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31216077

RESUMO

RATIONALE: The concentrations of aldehydes and volatile fatty acids have to be controlled because of their potential harmfulness in indoor air or relationship with the organoleptic properties of agri-food products. Although several specific analytical methods are currently used, the simultaneous analysis of these compounds in a complex matrix remains a challenge. The combination of positive and negative ionization selected ion flow tube mass spectrometry (SIFT-MS) allows the accurate, sensitive and high-frequency analysis of complex gas mixtures of these compounds. METHODS: The ion-molecule reactions of negative precursor ions (OH- , O•- , O2 •- , NO2 - and NO3 - ) with five aldehydes and four carboxylic acids were investigated in order to provide product ions and rate constants for the quantification of these compounds by negative ion SIFT-MS. The results were compared with those obtained by conventional analysis methods and/or with already implemented SIFT-MS positive ionization methods. The modelling of hydroxide ion (OH- )/molecule reaction paths by ab-initio calculation allowed a better understanding of these gas-phase reactions. RESULTS: Deprotonation systematically occurs by reaction between negative ions and aldehydes or acids, leading to the formation of [M - H]- primary ions. Ab-initio calculations demonstrated the α-CH deprotonation of aldehydes and the acidic proton abstraction for fatty acids. For aldehydes, the presence of water in the flow tube leads to the formation of hydrated ions, [M - H]- .H2 O. With the NO2 - precursor ion, a second reaction channel results in ion-molecule association with the formation of M.NO2 - ions. CONCLUSIONS: Except for formaldehyde, all the studied compounds can be quantified by negative ion SIFT-MS with significant rate constants. In addition to positive ion SIFT-MS with H3 O+ , O2 + and NO+ precursor ions, negative ionization with O•- , O2 •- , OH- , NO2 - and NO3 - extends the range of analysis of aldehydes and carboxylic acids in air without a preparation or separation step. This methodology was illustrated by the simultaneous quantification in single-scan experiments of seven aldehydes and six carboxylic acids released by building materials.

2.
Anal Bioanal Chem ; 409(12): 3199-3210, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28271224

RESUMO

The gas-phase concentration at the material surface (y 0 ) is pointed out in the literature as a key parameter to describe semivolatile organic compound (SVOC) emissions from materials. This is an important input data in predictive models of SVOC behavior indoors and risk exposure assessment. However, most of the existing measurement methods consist of determining emission rates and not y 0 and none allow on-site sampling. Hence, a new passive sampler was developed. It consists of a glass cell that is simply placed on the material surface until reaching equilibrium between material and air; y 0 is then determined by solid-phase microextraction (SPME) sampling and GC-MS analysis. The limits of detection are at the µg/m3 level and relative standard deviations (RSD) below 10%. A variation of 11% between two sets of experiments involving different cell volumes confirmed the y 0 measurement. In addition, due to the ability of SVOCs to be sorbed on surfaces, the cell wall/air partition was assessed by determining the inner cell surface concentration of SVOCs, which is the concentration of SVOCs adsorbed on the glass, and the cell surface/air partition coefficient (K glass ). The recovery yields of the SVOCs sorbed on the cell walls are strongly compound-dependent and comprise between 2 and 93%. The K glass coefficients are found to be lower than the stainless steel/air partition coefficient (K ss ), showing that glass is suitable for the SVOC sampling. This innovative tool opens up promising perspectives in terms of identification of SVOC sources and quantification of their emissions indoors, and would significantly contribute to human exposure assessment. Graphical Abstract Passive sampling for the determination of SVOCs concentration at the material/air interface.

3.
Environ Monit Assess ; 188(10): 576, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27650437

RESUMO

The purpose of this paper was to highlight potential exposure in indoor air to phosphorus flame retardants (PFRs) due to their use in upholstered furniture. For that, an analytical method of PFRs by headspace coupled to solid-phase micro-extraction (HS-SPME) was developed on cushioning foams in order to determine the PFRs' volatile fraction in the material. Tests on model foams proved the feasibility of the method. The average repeatability (RSD) is 6.3 % and the limits of detection range from 0.33 to 1.29 µg g(-1) of foam, depending on the PFRs. Results showed that some PFRs can actually be emitted in air, leading to a potential risk of exposure by inhalation. The volatile fraction can be high (up to 98 % of the total PFRs amount) and depends on the physicochemical properties of flame retardants, on the textural characteristics of the materials and on the temperature. The methodology developed for cushioning foams could be further applied to other types of materials and can be used to rate them according to their potential releases of phosphorus flame retardants.


Assuntos
Poluentes Atmosféricos/análise , Retardadores de Chama/análise , Decoração de Interiores e Mobiliário , Compostos Organofosforados/análise , Monitoramento Ambiental , Sistema Respiratório , Microextração em Fase Sólida , Volatilização
4.
J Am Soc Mass Spectrom ; 33(5): 865-874, 2022 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-35416666

RESUMO

Organophosphate esters are an emerging environmental concern since they spread persistently across all environmental compartments (air, soil, water, etc.). Measurements of semivolatile organic compounds are important but not without challenges due to their physicochemical properties. Selected ion flow tube-mass spectrometry (SIFT-MS) can be relevant for their analysis in air because it is a direct analytical method without separation that requires little preparation and no external calibration. SIFT-MS is based on the chemical reactivity of analytes with reactant ions. For volatile and semivolatile organic compound analysis in the gas phase, knowledge of ion-molecule reactions and kinetic parameters is essential for the utilization of this technology. In the present work, we focused on organophosphate esters, semivolatile compounds that are now ubiquitous in the environment. The ion-molecule reactions of eight precursor ions that are available in SIFT-MS (H3O+, NO+, O2•+, OH-, O•-, O2•-, NO2-, and NO3-) with six organophosphate esters were investigated. The modeling of ion-molecule reaction pathways by calculations supported and complemented the experimental work. Organophosphate esters reacted with six of the eight precursor ions with characteristic reaction mechanisms, such as protonation with hydronium precursor ions and association with NO+ ions, while nucleophilic substitution occurred with OH-, O•-, and O2•-. No reaction was observed with NO2- and NO3- ions. This work shows that the direct analysis of semivolatile organic compounds is feasible using SIFT-MS with both positive and negative ionization modes.


Assuntos
Ar , Dióxido de Nitrogênio , Ar/análise , Ésteres , Íons/química , Espectrometria de Massas/métodos , Dióxido de Nitrogênio/análise , Organofosfatos
5.
Food Chem ; 369: 130801, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34450514

RESUMO

Volatile organic compounds (VOCs) emitted by food products are decisive for the perception of aroma and taste. The analysis of gaseous matrices is traditionally done by detection and quantification of few dozens of characteristic markers. Emerging direct injection mass spectrometry technologies offer rapid analysis based on a soft ionisation of VOCs without previous separation. The recent increase of selectivity offered by the use of several precursor ions coupled with untargeted analysis increases the potential power of these instruments. However, the analysis of complex gaseous matrix results in a large number of ion conflicts, making the quantification of markers difficult, and in a large volume of data. In this work, we present the exploitation of untargeted SIFT-MS volatile fingerprints of ewe PDO cheeses in a real farm model, using mixOmics methods allowing us to illustrate the typicality, the manufacturing processes reproducibility and the impact of the animals' diet on the final product.


Assuntos
Queijo , Compostos Orgânicos Voláteis , Animais , Queijo/análise , Feminino , Espectrometria de Massas , Odorantes , Reprodutibilidade dos Testes , Ovinos , Compostos Orgânicos Voláteis/análise
6.
Anal Chim Acta ; 1186: 339100, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34756255

RESUMO

Actual methods for on-site measurement of gaseous concentrations of Semi-Volatile Organic Compounds (SVOCs) at the material surface (y0) are not yet sufficiently developed mainly due to sampling difficulties. These concentrations are the key data to improve knowledge about indoor sources and human exposure to SVOCs. To the end, a specific emission cell coupled to solid-phase microextraction (SPME) was developed. The main challenge with this method is calibration because of very low volatility of SVOCs and static sampling mode. In this study, a generating system of organophosphate flame retardants (OFRs) using polyurethane foam as source combined with an active sampling method with Tenax tubes was proposed as a novel calibration device for SPME-based method. The generating system delivered stable OFR concentrations after 190 h of operation with a variation not exceeding ±5%. It allowed to obtain robust calibrations for tris-(2-chloropropyl)-phosphate (TCPP) and tri-butyl-phosphate (TBP) measured with the emission cell coupled to SPME-based method, define the optimal sampling requirements and achieve reproducible and accurate measurements of y0 at µg.m-3 level. TCPP and TBP gas-phase concentrations at the polyurethane foam surface (y0) were followed up over more 228 days under controlled temperature conditions. A high stability of these concentrations was observed showing that polyurethane foam acts as a stable and continuous source of organophosphate flame retardants indoors. This novel method should be useful for assessing the dynamic of emissions from indoor sources and potential exposure to SVOCs in indoor environments.


Assuntos
Poluição do Ar em Ambientes Fechados , Retardadores de Chama , Compostos Orgânicos Voláteis , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Retardadores de Chama/análise , Gases , Humanos , Organofosfatos/análise , Microextração em Fase Sólida , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA