Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073051

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Assuntos
Hospitalização , Alta do Paciente , Humanos , Remoção de Dispositivo , Estudos de Viabilidade , Estudos Retrospectivos , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 35(7): 1422-1428, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38751010

RESUMO

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.


Assuntos
Amiloidose , Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Ablação por Cateter/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fatores de Risco , Fatores de Tempo , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/diagnóstico por imagem , Hemorragia/induzido quimicamente , Administração Oral , Estudos Retrospectivos , Medição de Risco , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Esquema de Medicação , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico
3.
J Cardiovasc Electrophysiol ; 34(8): 1690-1697, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37417961

RESUMO

INTRODUCTION: Transseptal puncture (TSP) to allow for large delivery sheath left atrial (LA) access remains a challenging aspect of LA appendage closure (LAAC) in patients with prior history of TSP, thick or lipomatous septum, atrial septal aneurysms, or other complex cardiac anatomies. This study investigates the use of the VersaCross large access (VLA) system (Baylis Medical/Boston Scientific) to improve procedural efficiency of LAAC compared to the standard needle workflow. METHODS AND RESULTS: Fifty LAAC procedures using WATCHMAN FLX between November 2021 and September 2022 were retrospectively analyzed comparing the VLA workflow (n = 25) to the standard needle workflow (n = 25). Study primary endpoint was time to procedural efficiency, and secondary endpoints included TSP time, acute LAAC success, fluoroscopy use, device recaptures, and periprocedural complications. Acute LAAC was successfully completed in all cases with no intraprocedural complications. TSP time was faster, but not significant, using the VLA workflow compared to the standard RF needle workflow (2.6 ± 1.1 min vs. 3.0 ± 1.8 min, p = 0.38). Time to WATCHMAN sheath in LA from TSP was 27% faster (1.5 ± 0.8 min vs. 2.1 ± 0.9 min; p = 0.03), and time to WATCHMAN release from TSP was 19% faster (10.5. ± 2.5 min vs. 13.0 ± 3.7 min; p = 0.01) with the VLA workflow. Overall procedure time was 15% faster (30.4 ± 5.1 min vs. 36.0 ± 6.6 min; p = 0.003) using VLA. Fluoroscopy time was 25% lower (4.0 ± 2.2 min vs. 5.5 ± 2.3 min; p = 0.003) and fluoroscopy dose was 60% lower (97.0 ± 91.7 mGy vs. 241.8 ± 240.6 mGy; p = 0.01) and more consistent [F-test, p ˂ 0.0001] using the VLA workflow compared to the needle workflow. CONCLUSION: The VLA system streamlines LAAC procedures, improving LAAC efficiency and reducing fluoroscopy use by allowing for de novo dilation of the septum for large-bore delivery sheaths, and reducing device exchanges and delivery sheath manipulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Cateterismo Cardíaco , Átrios do Coração , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 34(12): 2527-2534, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37746923

RESUMO

INTRODUCTION: Earlier studies have shown a clear association between severity of human immunodeficiency virus (HIV) infection and incident atrial fibrillation (AF). We present the long-term outcome of catheter ablation (CA) and electrophysiological characteristics in HIV+ AF patients. METHODS: This study evaluated 1438 consecutive AF patients [31 (2.15%) with HIV and 1407 (97.8%) without HIV diagnosis] undergoing their first CA at our center. A total of 31 HIV patients and 31 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model. During first procedure, all received isolation of pulmonary vein (PV) + posterior wall and superior vena cava. Non-PV triggers, defined as ectopic triggers originating from sites other than PVs, were identified at the redo ablation with high-dose isoproterenol challenge. RESULTS: Clinical characteristics were not different between the groups. When compared to the control, by the end of 5 years after the first procedure, recurrence was significantly greater in HIV group [100% vs. 54%, p < .001]. Among patients that underwent redo ablation non-PV triggers were higher in HIV group [93.5% vs. 54%, p < .001], and most frequently originated from the coronary sinus [67.7% vs. 45.2%, p < .001] and left atrial appendage [41.9% vs. 25.8%, p < .001]. After focal ablation of non-PV trigger, no difference in arrhythmia recurrence between two groups [80.6% vs. 87.1%, p = .753] at 1-year follow up was found. CONCLUSION: Our findings suggest that non-PV triggers are highly prevalent in HIV+ AF patients resulting in higher rate of the mid- and long-term arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Infecções por HIV , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Infecções por HIV/complicações , Infecções por HIV/diagnóstico , Veia Cava Superior , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
5.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378783

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Prevalência , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos
6.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36942834

RESUMO

AIMS: This study aimed to examine the clinical benefits of targeted ablation of all Premature ventricular complex (PVC) morphologies vs. predominant PVC only. METHODS AND RESULTS: A total of 171 consecutive patients with reduced left ventricular ejection fraction (LVEF) and ≥2 PVC morphology with high burden (>10%/day) undergoing their first ablation procedure were included in the analysis. At the initial procedure, prevalent PVC alone was ablated in the majority. However, at the redo, all PVC morphologies were targeted for ablation. : At the first procedure, 152 (89%) patients received ablation of the dominant PVC only. In the remaining 19 (11%) patients, all PVC morphologies were ablated. At two years, high PVC burden was detected in 89 (52%) patients. Repeat procedure was performed in 78 of 89, where all PVC morphologies were ablated. At 5 years after the repeat procedure, 71 (91%) had PVC burden of <5% [3.8 ± 1.1% vs. 15.4 ± 4.3% in successful vs. failed subjects (P < 0.001)]. In patients with low PVC burden after the initial procedure, LVEF improved from 37.5% to 41.6% [mean difference (MD): 3.39 ± 2.9%, P < 0.001], whereas a reduction in LVEF from 39.8% to 34.5% (MD: 6.45 ± 4.7%, P < 0.001) was recorded in patients with high PVC burden. One year after the repeat procedure, LVEF improved from 36.2% to 41.7% (MD: 5.5 ± 4.3%, P < 0.001) in patients with successful ablation. CONCLUSION: In this observational series, ablation of all PVC morphologies was associated with significantly lower PVC burden and improvement of LVEF at long-term follow-up, compared with ablation of the dominant morphology only.


Assuntos
Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/complicações
7.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37889200

RESUMO

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Prognóstico , Resultado do Tratamento , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversos
8.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225176

RESUMO

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Transversais , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos
9.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
10.
J Cardiovasc Electrophysiol ; 32(8): 2337-2339, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34176172

RESUMO

Herein, we present a case of laser-assisted extraction of a retained lead remnant following incomplete removal of an implantable cardiac defibrillator system implanted via a left femoral approach.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Eletrodos Implantados , Humanos , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/cirurgia , Lasers , Marca-Passo Artificial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA