Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 23(9): 1350-1358, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33880542

RESUMO

Strong recent clinical evidence links the presence of prominent oscillations of ventricular repolarization in the low-frequency range (0.04-0.15 Hz) to the incidence of ventricular arrhythmia and sudden death in post-MI patients and patients with ischaemic and non-ischaemic cardiomyopathy. It has been proposed that these oscillations reflect oscillations of ventricular action potential duration at the sympathetic nerve frequency. Here we review emerging evidence to support that contention and provide insight into possible underlying mechanisms for this association.


Assuntos
Arritmias Cardíacas , Infarto do Miocárdio , Potenciais de Ação , Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Ventrículos do Coração , Humanos
2.
Pacing Clin Electrophysiol ; 39(6): 531-41, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27001004

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular epicardial (BV-CS) or endocardial left ventricular (LV) stimulation (BV-EN) improves LV hemodynamics. The effect of CRT on right ventricular function is less clear, particularly for BV-EN. Our objective was to compare the simultaneous acute hemodynamic response (AHR) of the right and left ventricles (RV and LV) with BV-CS and BV-EN in order to determine the optimal mode of CRT delivery. METHODS: Nine patients with previously implanted CRT devices successfully underwent a temporary pacing study. Pressure wires measured the simultaneous AHR in both ventricles during different pacing protocols. Conventional epicardial CRT was delivered in LV-only (LV-CS) and BV-CS configurations and compared with BV-EN pacing in multiple locations using a roving decapolar catheter. RESULTS: Best BV-EN (optimal AHR of all LV endocardial pacing sites) produced a significantly greater RV AHR compared with LV-CS and BV-CS pacing (P < 0.05). RV AHR had a significantly increased standard deviation compared to LV AHR (P < 0.05) with a weak correlation between RV and LV AHR (Spearman rs = -0.06). Compromised biventricular optimization, whereby RV AHR was increased at the expense of a smaller decrease in LV AHR, was achieved in 56% of cases, all with BV-EN pacing. CONCLUSIONS: BV-EN pacing produces significant increases in both LV and RV AHR, above that achievable with conventional epicardial pacing. RV AHR cannot be used as a surrogate for optimizing LV AHR; however, compromised biventricular optimization is possible. The beneficial effect of endocardial LV pacing on RV function may have important clinical benefits beyond conventional CRT.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Hemodinâmica , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Endocárdio , Feminino , Humanos , Masculino
3.
Am J Physiol Heart Circ Physiol ; 309(12): H2108-17, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26475587

RESUMO

Ventricular action potential duration (APD) is an important component of many physiological functions including arrhythmogenesis. APD oscillations have recently been reported in humans at the respiratory frequency. This study investigates the contribution of the autonomic nervous system to these oscillations. In 10 patients undergoing treatment for supraventricular arrhythmias, activation recovery intervals (ARI; a conventional surrogate for APD) were measured from multiple left and right ventricular (RV) endocardial sites, together with femoral artery pressure. Respiration was voluntarily regulated and heart rate clamped by RV pacing. Sympathetic and parasympathetic blockade was achieved using intravenous metoprolol and atropine, respectively. Metroprolol reduced the rate of pressure development (maximal change in pressure over time): 1,271 (± 646) vs. 930 (± 433) mmHg/s; P < 0.01. Systolic blood pressure (SBP) showed a trend to decrease after metoprolol, 133 (± 21) vs. 128 (± 25) mmHg; P = 0.06, and atropine infusion, 122 (± 26) mmHg; P < 0.05. ARI and SBP exhibited significant cyclical variations (P < 0.05) with respiration in all subjects with peak-to-peak amplitudes ranging between 0.7 and 17.0 mmHg and 1 and 16 ms, respectively. Infusion of metoprolol reduced the mean peak-to-peak amplitude [ARI, 6.2 (± 1.4) vs. 4.4 (± 1.0) ms, P = 0.008; SBP, 8.4 (± 1.6) vs. 6.2 (± 2.0) mmHg, P = 0.002]. The addition of atropine had no significant effect. ARI, SBP, and respiration showed significant coupling (P < 0.05) at the breathing frequency in all subjects. Directed coherence from respiration to ARI was high and reduced after metoprolol infusion [0.70 (± 0.17) vs. 0.50 (± 0.23); P < 0.05]. These results suggest a role of respiration in modulating the electrophysiology of ventricular myocardium in humans, which is partly, but not totally, mediated by ß-adrenergic mechanisms.


Assuntos
Potenciais de Ação/efeitos dos fármacos , Bloqueio Nervoso Autônomo , Ventrículos do Coração/efeitos dos fármacos , Mecânica Respiratória , Antagonistas Adrenérgicos beta/farmacologia , Idoso , Antiarrítmicos/farmacologia , Atropina/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Eletrocardiografia/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Metoprolol/farmacologia , Pessoa de Meia-Idade , Antagonistas Muscarínicos/farmacologia , Parassimpatolíticos/farmacologia , Taquicardia Supraventricular/fisiopatologia , Função Ventricular Esquerda/efeitos dos fármacos , Função Ventricular Direita/efeitos dos fármacos
4.
Europace ; 17(8): 1241-50, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25687748

RESUMO

AIMS: To prospectively compare cardiac magnetic resonance late gadolinium enhancement (LGE) findings created by standard vs. robotically assisted catheter ablation lesions and correlate these with clinical outcomes. METHODS AND RESULTS: Forty paroxysmal atrial fibrillation patients (mean age 54 ± 13.8 years) undergoing first left atrial ablation were randomized to either robotic-assisted navigation (Hansen Sensei(®) X) or standard navigation. Pre-procedural, acute (24 h post-procedure) and late (beyond 3 months) scans were performed with LGE and T2W imaging sequences and percentage circumferential enhancement around the pulmonary vein (PV) antra were quantified. Baseline pre-procedural enhancements were similar in both groups. On acute imaging, mean % encirclements by LGE and T2W signal were 72% and 80% in the robotic group vs. 60% (P = 0.002) and 76%(P = 0.45) for standard ablation. On late imaging, the T2W signal resolved to baseline in both groups. Late gadolinium enhancement remained the predominant signal with 56% encirclement in the robotic group vs. 45% in the standard group (P = 0.04). At 6 months follow-up, arrhythmia-free patients had an almost similar mean LGE encirclement (robotic 64%, standard 60%, P = 0.45) but in recurrences, LGE was higher in the robotic group (43% vs. 30%, P = 0.001). At mean 3 years follow-up, 1.3 procedures were performed in the robotic group compared with 1.9 (P < 0.001) in the standard to achieve a success rate of 80% vs. 75%. CONCLUSION: Robotically assisted ablation results in greater LGE around the PV antrum. Effective lesions created through improved catheter stability and contact force during initial treatment may have a role in reducing subsequent re-do procedures.


Assuntos
Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Imagem Cinética por Ressonância Magnética/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Meios de Contraste , Feminino , Gadolínio , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Resultado do Tratamento
5.
Europace ; 15(6): 865-70, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23180646

RESUMO

AIMS: The number of patients requiring an extraction of cardiac implantable electronic devices (CIEDs) is rising. Lead extraction of chronically implanted leads is a highly specialized procedure and the Heart Rhythm Society published a consensus document outlining best practice. We sought to ascertain the current practice and perception of lead extraction in the UK. METHODS AND RESULTS: A prospective e-mail survey consisting of 21 questions was sent to members of Heart Rhythm UK. Key areas for exploration included case volume, settings for extraction procedures, levels of surgical support, preferred techniques, and the perceptions of difficulty, risk, morbidity, and mortality associated with lead extraction. Thirty responses were received giving a response rate of 9.3%. Eighty-three per cent of responders performed extractions regularly and of these 92% were electrophysiologists. Median number of cases performed per year was 13 (interquartile range 6-26). Fifty-six per cent performed <20 procedures per year. Eighty per cent of procedures were performed in the electrophysiology (EP) laboratory and of these 50% had no identifiable surgeon or operating theatre on standby. Mechanical dissection sheaths were the most widely used method of extraction after failure of manual traction (63%). The risk of minor complications was perceived to be 4% or less by the majority of respondents across the device range. The same measure for major complications and death was 2 and 1%, respectively. CONCLUSION: Increased operator caseload and closer links between EP extractors and surgeons should be seen as achievable goals.


Assuntos
Atitude do Pessoal de Saúde , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/mortalidade , Eletrodos Implantados/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Padrões de Prática Médica/estatística & dados numéricos , Coleta de Dados , Humanos , Incidência , Médicos/estatística & dados numéricos , Análise de Sobrevida , Taxa de Sobrevida , Reino Unido/epidemiologia , Carga de Trabalho/estatística & dados numéricos
6.
Europace ; 14(1): 99-106, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21752827

RESUMO

AIMS: Early inward motion and thickening/thinning of the ventricular septum associated with left bundle branch block is known as the septal flash (SF). Correction of SF corresponds to response to cardiac resynchronization therapy (CRT). We hypothesized that SF was associated with a specific left ventricular (LV) activation pattern predicting a favourable response to CRT. We sought to characterize the spatio-temporal relationship between electrical and mechanical events by directly comparing non-contact mapping (NCM), acute haemodynamics, and echocardiography. METHODS AND RESULTS: Thirteen patients (63 ± 10 years, 10 men) with severe heart failure (ejection fraction 22.8 ± 5.8%) awaiting CRT underwent echocardiography and NCM pre-implant. Presence and extent of SF defined visually and with M-mode was fused with NCM bull's eye plots of endocardial activation patterns. LV-dP/dt(max) was measured during different pacing modes. Five patients had a large SF, four small SF, and four no SF. Large SF patients had areas of conduction block in non-infarcted regions, whereas those with small or no SF did not. Patients with large SF had greater acute response to LV and biventricular (BIV) pacing vs. those with small/no SF (% increase dP/dt 28 ± 14 vs. 11 ± 19% for LV pacing and 42 ± 28 vs. 22 ± 21% for BIV pacing) (P < 0.05). This translated into a more favourable chronic response to CRT. The lines of conduction block disappeared with LV/BIV pacing while remaining with right ventricle pacing. CONCLUSION: A strong association exists between electrical activation and mechanical deformation of the septum. Correction of both mechanical synchrony and the functional conduction block by CRT may explain the favourable response in patients with SF.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/terapia , Septos Cardíacos/fisiopatologia , Idoso , Bloqueio de Ramo/diagnóstico por imagem , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Septos Cardíacos/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Resultado do Tratamento , Ultrassonografia
7.
Indian Pacing Electrophysiol J ; 12(3): 82-92, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22665957

RESUMO

INTRODUCTION: We describe the use of a ablating system to compartmentalise and regionally isolate the atria in paroxysmal and persistent atrial fibrillation (AF). METHODS: 40 patients were studied, 25 paroxysmal AF and 14 persistent AF. One patient enrolled was later found to be in left atrial flutter and was excluded. The Cardima Revelation® TX catheter system with Intellitemp® Radiofrequency (RF) energy control device and a Medtronic Atakar® RF generator were used to place wide area circumferential ablations to achieve conduction block into the left and right sided pulmonary veins. Roof lines and mitral isthmus lines were also performed. In patients with persistent AF and in repeat procedures, right atrial compartmentalisation was performed with an anterior superior vena cava (SVC) to inferior vena cava (IVC) line and a septal SVC to IVC line. RESULTS: At 6 months, 18 of the 39 patients were asymptomatic, 10 had improved symptoms and 22 were in sinus rhythm. In the paroxysmal group, 11 were asymptomatic, 7 had improved symptoms and 16 (64%) were in sinus rhythm. In the persistent group, 7 were asymptomatic, 3 had improved symptoms and 6 (43%) were in sinus rhythm. The total group AF burden was 37.8 ± 5.4 hrs pre-procedure and 23.1 ± 5.1 hrs at 6 months post procedure. Mean temperature, impedance and power recorded at each pole demonstrated effective power delivery at all poles. No catheter charring was observed, complication rates were comparable to standard AF ablation technique. CONCLUSION: Linear ablation in the left and right atria to mimic Cox's Maze is feasible and safe using this ablating system.

8.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36346176

RESUMO

OBJECTIVES: Atrial fibrillation (AF) is common and can cause significant morbidity and detriment to quality of life. Success rates for conventional catheter ablation are suboptimal in persistent AF (PsAF), especially when longstanding. Convergent hybrid ablation combines endoscopic surgical epicardial and endocardial catheter ablation. It offers promise in treating PsAF. We aimed to evaluate outcomes at our centre following convergent ablation. METHODS: We conducted an observational study of patients undergoing ablation from 2012 to 2019 at a London cardiac centre. Sixty-seven patients underwent convergent ablation entailing epicardial ablation, mostly via sub-xiphoid access, followed by endocardial left atrial catheter ablation. Baseline and follow-up data were obtained retrospectively from clinical records. Primary outcome was freedom from AF on/off anti-arrhythmic drugs after 12-month follow-up. Secondary outcomes included freedom from AF over the entire follow-up, freedom from anti-arrhythmic drugs, freedom from atrial arrhythmias, symptom status, repeat ablation and complications. RESULTS: At baseline, 80.6% had PsAF >1 year (80.6%), 49.3% had body mass index >30 kg/m2 at baseline and 19.4% had left ventricular ejection fraction of 40% or less. The median follow-up was 2.3 (1.4-3.7) years. Freedom from AF recurrence was 81.3% at 1 year and 61.5% over overall follow-up. Eleven patients (16.4%) required redo AF ablation. Prolonged AF duration was associated with increased recurrence at 12 months and duration >5 years with a shorter time to recurrence on Kaplan-Meier analysis, but this and other factors did not significantly impact the AF recurrence during the overall follow-up period. CONCLUSIONS: Convergent ablation had good 1-year and overall success rates for treating PsAF. Our results in a diverse, real-world population support the potential of convergent ablation in patients with challenging to treat PsAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Antiarrítmicos/uso terapêutico , Estudos Retrospectivos , Volume Sistólico , Qualidade de Vida , Resultado do Tratamento , Função Ventricular Esquerda , Recidiva Local de Neoplasia/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
9.
Indian Pacing Electrophysiol J ; 11(1): 5-14, 2011 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-21468273

RESUMO

BACKGROUND: Dual chamber pacing improves functional status and reduces left ventricular outflow tract gradients in some, but not all patients with hypertrophic cardiomyopathy (HCM) by altering ventricular depolarisation. We investigated the use of biventricular (BIV) pacing in symptomatic patients with HCM. METHOD: 8 patients aged 58±7yrs with symptomatic HCM underwent BIV pacing. 5 patients had LVOT gradients >30mmHg. Ventricular electrodes were placed in the right ventricle (RV) and a branch of the coronary sinus. An atrial electrode was inserted to achieve BIV pacing with a short AV delay. The short-term effects of different pacing modalities were assessed using 2-D and Doppler echocardiography. Symptoms and exercise tolerance were assessed after a month of each pacing mode. Long-term follow up data was available for 5 years. RESULTS: Baseline EF was 67±14% and mean QRS duration was 132±26msecs. BIV pacing reduced QRS duration compared to RV pacing (129±46 vs. 205±54msecs, p<0.005). Five of the seven patients had baseline LVOT gradients (mean 67±25mmHg) that decreased to 41±15mm Hg with RV pacing (p<0.01) and 25±15mmHg with BIV pacing (p<0.005). Improvements in exercise time with active pacing occurred in six out of eight patients (75%), three (37.5%) had optimal exercise times with RV pacing and three with BIV pacing. Of the three patients with short term improvements with BIV pacing, one died 4 years post implant, one deteriorated with LV dilatation and one had the system explanted for infection. CONCLUSION: BIV pacing showed short-term beneficial effects in some patients over and above RV pacing alone.

10.
Arrhythm Electrophysiol Rev ; 10(3): 198-204, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34777825

RESUMO

Recent advances have been made in AF treatment, including the role of early rhythm control and landmark clinical trials using ablation therapy. However, some treatment gaps remain, including the creation of durable lesions outside the pulmonary veins and effective treatment of longstanding persistent AF. A novel epicardial-endocardial ablation approach - the hybrid convergent procedure - was developed to combine surgical and catheter ablation techniques into a collaborative, multidisciplinary approach to managing AF. In this review, the authors discuss recently published data on hybrid convergent ablation, including results of the CONVERGE clinical trial, in the context of current challenges to treatment of persistent and long-standing persistent AF. The review also aims to provide perspective on outstanding questions and future directions in this area.

11.
Front Physiol ; 12: 707189, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34646149

RESUMO

Electrical activation during atrial fibrillation (AF) appears chaotic and disorganised, which impedes characterisation of the underlying substrate and treatment planning. While globally chaotic, there may be local preferential activation pathways that represent potential ablation targets. This study aimed to identify preferential activation pathways during AF and predict the acute ablation response when these are targeted by pulmonary vein isolation (PVI). In patients with persistent AF (n = 14), simultaneous biatrial contact mapping with basket catheters was performed pre-ablation and following each ablation strategy (PVI, roof, and mitral lines). Unipolar wavefront activation directions were averaged over 10 s to identify preferential activation pathways. Clinical cases were classified as responders or non-responders to PVI during the procedure. Clinical data were augmented with a virtual cohort of 100 models. In AF pre-ablation, pathways originated from the pulmonary vein (PV) antra in PVI responders (7/7) but not in PVI non-responders (6/6). We proposed a novel index that measured activation waves from the PV antra into the atrial body. This index was significantly higher in PVI responders than non-responders (clinical: 16.3 vs. 3.7%, p = 0.04; simulated: 21.1 vs. 14.1%, p = 0.02). Overall, this novel technique and proof of concept study demonstrated that preferential activation pathways exist during AF. Targeting patient-specific activation pathways that flowed from the PV antra to the left atrial body using PVI resulted in AF termination during the procedure. These PV activation flow pathways may correspond to the presence of drivers in the PV regions.

12.
Heart Rhythm ; 18(2): 303-312, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33045430

RESUMO

The absence of strategies to consistently and effectively address nonparoxysmal atrial fibrillation by nonpharmacological interventions has represented a long-standing treatment gap. A combined epicardial/endocardial ablation strategy, the hybrid Convergent procedure, was developed in response to this clinical need. A subxiphoid incision is used to access the pericardial space facilitating an epicardial ablation directed at isolation of the posterior wall of the left atrium. This is followed by an endocardial ablation to complete isolation of the pulmonary veins and for additional ablation as needed. Experience gained with the hybrid Convergent procedure during the last decade has led to the development and adoption of strategies to optimize the technique and mitigate risks. Additionally, a surgical and electrophysiology "team" approach including comprehensive training is believed critical to successfully develop the hybrid Convergent program. A recently completed randomized clinical trial indicated that this ablation strategy is superior to an endocardial-only approach for patients with persistent atrial fibrillation. In this review, we propose and describe best practice guidelines for hybrid Convergent ablation on the basis of a combination of published data, author consensus, and expert opinion. A summary of clinical outcomes, emerging evidence, and future perspectives is also given.


Assuntos
Fibrilação Atrial/cirurgia , Endocárdio/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Pericárdio/cirurgia , Guias de Prática Clínica como Assunto , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Humanos , Recidiva
13.
Cardiol Young ; 20(2): 226-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20307333

RESUMO

We report on a 37-year-old woman presenting with atrial arrhythmias after catheter closure of a secundum atrial septal defect with an Amplatzer septal occluder device. Electrophysiological studies suggested that the arrhythmia originated from the left atrium, from an area near the device. Transseptal puncture was successfully performed under transoesophageal guidance and the arrhythmia was successfully ablated. This case showed that transseptal puncture can be safely performed in the presence of an Amplatzer septal occluder device under transoesophageal echocardiography guidance and we speculate that the device may have created the substrate for the arrhythmia.


Assuntos
Ablação por Cateter/métodos , Comunicação Interatrial/complicações , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Taquicardia/cirurgia , Adulto , Flutter Atrial/terapia , Cardioversão Elétrica , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos
14.
Int J Cardiol ; 312: 64-70, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32169346

RESUMO

BACKGROUND: Cardiac implanted electronic devices (CIEDs) can detect short durations of previously unrecognised atrial fibrillation (AF). The prognostic significance of device-detected subclinical AF, in the context of contemporary heart failure (HF) therapy, is unclear. METHODS: Amongst patients enrolled in the Remote Monitoring in HF with implanted devices (REM-HF) trial, three categories were defined based on total AF duration in the first year of follow-up: no AF, subclinical AF (≥6 min to ≤24 h), and AF >24 h. All-cause mortality, stroke, and cardiovascular hospitalisation were assessed. RESULTS: 1561 patients (94.6%) had rhythm data: 71 (4.6%) had subclinical AF (median of 4 episodes, total duration 3.1 h) and 279 (17.9%) had AF >24 h. During 2.8 ± 0.8 years' follow-up, 39 (2.5%) patients had a stroke. Stroke rate was highest amongst patients with subclinical AF (2.0 per 100-person years) versus no AF or AF >24 h (0.8 and 1.0 per 100-person years, respectively). In the overall cohort, AF >24 h was not an independent predictor of stroke. However, amongst patients with no history of AF (n = 932), new-onset subclinical AF conferred a three-fold higher stroke risk (adjusted HR 3.35, 95%CI 1.15-9.77, p = 0.027). AF >24 h was associated with more frequent emergency cardiovascular hospitalisation (adjusted HR 1.46, 95%CI 1.19-1.79, p < 0.0005). Neither AF classification was associated with mortality. CONCLUSIONS: In patients with HF and a CIED, subclinical AF was infrequent but, as a new finding, was associated with an increased risk of stroke. Anticoagulation remains an important consideration in this population, particularly when the clinical profile indicates a high stroke risk.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Acidente Vascular Cerebral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Humanos , Prevalência , Prognóstico , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Volume Sistólico
15.
Eur J Heart Fail ; 22(3): 543-553, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31908129

RESUMO

AIMS: Studies of remote monitoring (RM) in heart failure (HF) speculate that patients with atrial fibrillation (AF) derive the greatest benefit. We compared the impact of RM vs. usual care on clinical outcomes for patients with and without AF enrolled in the Remote Management of Heart Failure Using Implanted Electronic Devices (REM-HF) trial. METHODS AND RESULTS: Rhythm status was available for 1561 patients (94.6%). Three categories were defined based on total AF duration during the first year of follow-up: (i) no AF (n = 1211, 77.6%), (ii) paroxysmal AF (≥6 min to ≤7 days; n = 92, 5.9%), and (iii) persistent/permanent AF (>7 days; n = 258, 16.5%). Clinical activity, mortality, and hospitalisation rates were compared between treatment strategies for each group. RM resulted in a greater volume of clinical activity in patients with any AF, vs. no AF, with the highest per-patient intervention required for patients with persistent/permanent AF. During 2.8 ± 0.8 years of follow-up, RM was not associated with a reduction in all-cause or cardiovascular mortality for patients with AF. However, in patients with persistent/permanent AF, RM conferred an increased risk of recurrent cardiovascular [hazard ratio (HR) 1.40, 95% confidence interval (CI) 1.06-1.85, P = 0.018] and HF-related (HR 2.05, 95% CI 1.14-3.69, P = 0.016) hospitalisations. CONCLUSION: In patients with HF and a cardiac implanted electronic device, RM generated greater clinical activity for patients with AF, with no associated reduction in mortality, and conversely, greater risk of cardiovascular hospitalisation amongst patients with persistent/permanent AF. RM strategies may vary in their capability to guide HF management; modified approaches may be needed to improve outcomes for HF patients with AF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Modelos de Riscos Proporcionais
16.
Front Physiol ; 10: 1582, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32038279

RESUMO

BACKGROUND: Recent clinical, experimental and modeling studies link oscillations of ventricular repolarization in the low frequency (LF) (approx. 0.1 Hz) to arrhythmogenesis. Sympathetic provocation has been shown to enhance both LF oscillations of action potential duration (APD) and beat-to-beat variability (BVR) in humans. We hypothesized that beta-adrenergic blockade would reduce LF oscillations of APD and BVR of APD in humans and that the two processes might be linked. METHODS AND RESULTS: Twelve patients with normal ventricles were studied during routine electrophysiological procedures. Activation-recovery intervals (ARI) as a conventional surrogate for APD were recorded from 10 left and 10 right ventricular endocardial sites before and after acute beta-adrenergic adrenergic blockade. Cycle length was maintained constant with right ventricular pacing. Oscillatory behavior of ARI was quantified by spectral analysis and BVR as the short-term variability. Beta-adrenergic blockade reduced LF ARI oscillations (8.6 ± 4.5 ms2 vs. 5.5 ± 3.5 ms2, p = 0.027). A significant correlation was present between the initial control values and reduction seen following beta-adrenergic blockade in LF ARI (r s = 0.62, p = 0.037) such that when initial values are high the effect is greater. A similar relationship was also seen in the beat-to beat variability of ARI (r s = 0.74, p = 0.008). There was a significant correlation between the beta-adrenergic blockade induced reduction in LF power of ARI and the witnessed reduction of beat-to-beat variability of ARI (r s = 0.74, p = 0.01). These clinical results accord with recent computational modeling studies which provide mechanistic insight into the interactions of LF oscillations and beat-to-beat variability of APD at the cellular level. CONCLUSION: Beta-adrenergic blockade reduces LF oscillatory behavior of APD (ARI) in humans in vivo. Our results support the importance of LF oscillations in modulating the response of BVR to beta-adrenergic blockers, suggesting that LF oscillations may play role in modulating beta-adrenergic mechanisms underlying BVR.

17.
Heart Rhythm ; 16(5): 702-709, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30528448

RESUMO

BACKGROUND: Enhanced beat-to-beat variability of repolarization is strongly linked to arrhythmogenesis and is largely due to variation in ventricular action potential duration (APD). Previous studies in humans have relied on QT interval measurements; however, a direct relationship between beat-to-beat variability of APD and arrhythmogenesis in humans has yet to be demonstrated. OBJECTIVE: This study aimed to explore the beat-to-beat repolarization dynamics in patients with heart failure at the level of ventricular APD. METHODS: Forty-three patients with heart failure and implanted cardiac resynchronization therapy - defibrillator devices were studied. Activation-recovery intervals as a surrogate for APD were recorded from the left ventricular epicardial lead while pacing from the right ventricular lead to maintain a constant cycle length. RESULTS: During a mean follow-up of 23.6±13.6 months, 11 patients sustained ventricular fibrillation/ventricular tachycardia (VT/VF) and received appropriate implantable cardioverter-defibrillator therapies (antitachycardia pacing or shock therapy). Activation-recovery interval variability (ARIV) was significantly greater in patients with subsequent VT/VF than in those without VT/VF (3.55±1.3 ms vs 2.77±1.09 ms; P=.047). Receiver operating characteristic curve analysis (area under the curve 0.71; P=.046) suggested high- and low-risk ARIV groups for VT/VF. Kaplan-Meier survival analysis demonstrated that the time until first appropriate therapy for VT/VF was significantly shorter in the high-risk ARIV group (P=.028). ARIV was a predictor for VT/VF in the multivariate Cox model (hazard ratio 1.623; 95% confidence interval 1.1-2.393; P=.015). CONCLUSION: Increased left ventricular ARIV is associated with an increased risk of VT/VF in patients with heart failure.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular , Análise de Variância , Desfibriladores Implantáveis , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia
18.
Front Physiol ; 9: 147, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29670531

RESUMO

Background: The temporal pattern of ventricular repolarization is of critical importance in arrhythmogenesis. Enhanced beat-to-beat variability (BBV) of ventricular action potential duration (APD) is pro-arrhythmic and is increased during sympathetic provocation. Since sympathetic nerve activity characteristically exhibits burst patterning in the low frequency range, we hypothesized that physiologically enhanced sympathetic activity may not only increase BBV of left ventricular APD but also impose a low frequency oscillation which further increases repolarization instability in humans. Methods and Results: Heart failure patients with cardiac resynchronization therapy defibrillator devices (n = 11) had activation recovery intervals (ARI, surrogate for APD) recorded from left ventricular epicardial electrodes alongside simultaneous non-invasive blood pressure and respiratory recordings. Fixed cycle length was achieved by right ventricular pacing. Recordings took place during resting conditions and following an autonomic stimulus (Valsalva). The variability of ARI and the normalized variability of ARI showed significant increases post Valsalva when compared to control (p = 0.019 and p = 0.032, respectively). The oscillatory behavior was quantified by spectral analysis. Significant increases in low frequency (LF) power (p = 0.002) and normalized LF power (p = 0.019) of ARI were seen following Valsalva. The Valsalva did not induce changes in conduction variability nor the LF oscillatory behavior of conduction. However, increases in the LF power of ARI were accompanied by increases in the LF power of systolic blood pressure (SBP) and the rate of systolic pressure increase (dP/dtmax). Positive correlations were found between LF-SBP and LF-dP/dtmax (rs = 0.933, p < 0.001), LF-ARI and LF-SBP (rs = 0.681, p = 0.001) and between LF-ARI and LF-dP/dtmax (rs = 0.623, p = 0.004). There was a strong positive correlation between the variability of ARI and LF power of ARI (rs = 0.679, p < 0.001). Conclusions: In heart failure patients, physiological sympathetic provocation induced low frequency oscillation (~0.1 Hz) of left ventricular APD with a strong positive correlation between the LF power of APD and the BBV of APD. These findings may be of importance in mechanisms underlying stability/instability of repolarization and arrhythmogenesis in humans.

19.
Front Physiol ; 8: 328, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28611676

RESUMO

Background: Exaggerated beat-to-beat variability of ventricular action potential duration (APD) is linked to arrhythmogenesis. Sympathetic stimulation has been shown to increase QT interval variability, but its effect on ventricular APD in humans has not been determined. Methods and Results: Eleven heart failure patients with implanted bi-ventricular pacing devices had activation-recovery intervals (ARI, surrogate for APD) recorded from LV epicardial electrodes under constant RV pacing. Sympathetic activity was increased using a standard autonomic challenge (Valsalva) and baroreceptor indices were applied to determine changes in sympathetic stimulation. Two Valsalvas were performed for each study and were repeated, both off and on bisoprolol. In addition sympathetic nerve activity (SNA) was measured from skin electrodes on the thorax using a novel validated method. Autonomic modulation significantly increased mean short-term variability in ARI; off bisoprolol mean STV increased from 3.73 ± 1.3 to 5.27 ± 1.04 ms (p = 0.01), on bisoprolol mean STV of ARI increased from 4.15 ± 1.14 to 4.62 ± 1 ms (p = 0.14). Adrenergic indices of the Valsalva demonstrated significantly reduced beta-adrenergic function when on bisoprolol (Δ pressure recovery time, p = 0.04; Δ systolic overshoot in Phase IV, p = 0.05). Corresponding increases in SNA from rest both off (1.4 uV, p < 0.01) and on (0.7 uV, p < 0.01) bisoprolol were also seen. Conclusions: Beat-to-beat variability of ventricular APD increases during brief periods of increased sympathetic activity in patients with heart failure. Bisoprolol reduces, but does not eliminate, these effects. This may be important in the genesis of ventricular arrhythmias in heart failure patients.

20.
Circulation ; 107(2): 285-9, 2003 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-12538429

RESUMO

BACKGROUND: Enhanced sympathetic activity facilitates complex ventricular arrhythmias and fibrillation. The restitution properties of action potential duration (APD) are important determinants of electrical stability in the myocardium. Steepening of the slope of APD restitution has been shown to promote wave break and ventricular fibrillation. The effect of adrenergic stimulation on APD restitution in humans is unknown. METHODS AND RESULTS: Monophasic action potentials were recorded from the right ventricular septum in 18 patients. Standard APD restitution curves were constructed at 3 basic drive cycle lengths (CLs) of 600, 500, and 400 ms under resting conditions and during infusion of isoprenaline (15 patients) or adrenaline (3 patients). The maximum slope of the restitution curves was measured by piecewise linear regression segments of sequential 40-ms ranges of diastolic intervals in steps of 10 ms. Under control conditions, the maximum slope was steeper at longer basic CLs; eg, mean values for the maximum slope were 1.053+/-0.092 at CL 600 ms and 0.711+/-0.049 at CL 400 ms (+/-SEM). Isoprenaline increased the steepness of the maximum slope of APD restitution, eg, from a maximum slope of 0.923+/-0.058 to a maximum slope of 1.202+/-0.121 at CL 500 ms. The effect of isoprenaline was greater at the shorter basic CLs. A similar overall effect was observed with adrenaline. CONCLUSIONS: The adrenergic agonists isoprenaline and adrenaline increased the steepness of the slope of the APD restitution curve in humans over a wide range of diastolic intervals. These results may relate to the known effects of adrenergic stimulation in facilitating ventricular fibrillation.


Assuntos
Potenciais de Ação/fisiologia , Agonistas alfa-Adrenérgicos/farmacologia , Agonistas Adrenérgicos beta/farmacologia , Técnicas Eletrofisiológicas Cardíacas , Função Ventricular , Potenciais de Ação/efeitos dos fármacos , Adulto , Idoso , Diástole/fisiologia , Epinefrina/farmacologia , Feminino , Ventrículos do Coração/efeitos dos fármacos , Humanos , Isoproterenol/farmacologia , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA