Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(8): 5339-5348, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38206402

RESUMO

OBJECTIVE(S): To determine the frequency of olfactory cleft (OC) stenosis and obstruction on paranasal sinus CT scans in pre-septorhinoplasty of patients who had septal deviation, septopyramidal deformation or nasal obstruction without other sinonasal conditions. METHODS: This retrospective study included patients referred to our institution between December 2013 and December 2021 for septorhinoplasty due to nasal obstruction without other sinonasal or neurological conditions. All patients underwent preoperative paranasal sinus CT scan and olfactory testing. OC stenosis was quoted as none, partial, or total (less than 1/3 contact between nasal septum and ethmoid turbinates, 1/3-2/3, more than 2/3, respectively), as well as OC obstruction as none, partial, or complete (obstruction of less than 1/3 of OC, 1/3-2/3, more than 2/3, respectively). Radiologic evaluation was validated by near perfect interobserver agreement. RESULTS: A total of 75 patients (32 women, 43 men) with a mean age of 44.2 ± 15.64 (23-74) years were included, of which 36 were normosmic and 39 hyposmic. OC stenosis was partial in 58.7% (n = 44) of the patients, absent in 28% (n = 21), and total in 13.3% (n = 10), without difference between normosmic and hyposmic patients (p = .66). OC obstruction was absent in 52% (n = 39) and partial in 46.7% (n = 35), without difference between normosmic and hyposmic patients (p = .51). Only one normosmic patient had complete OC obstruction. CONCLUSION: OC partial stenosis and partial obstruction were frequent findings in pre-septorhinoplasty patients without respiratory mucosa disease and did not influence their olfactory status. Total stenosis and complete obstruction were rarer and require further investigation. CLINICAL RELEVANCE STATEMENT: Isolated partial olfactory cleft stenosis and obstruction should be considered normal variants, whereas the impact of complete olfactory cleft stenosis and obstruction on patient's olfactory status remains to be determined. KEY POINTS: • The incidence of olfactory cleft stenosis and obstruction in asymptomatic patients remains unknown, even though it is encountered in clinical practice. • Partial and total olfactory cleft stenosis occurred in 58.7% and 13.3% of the patients; partial obstruction occurred in half of the cases, but complete obstruction was extremely rare. • There are frequent findings of partial olfactory cleft obstruction and stenosis, but complete obstruction and total stenosis should be further investigated.


Assuntos
Obstrução Nasal , Rinoplastia , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Estudos Retrospectivos , Adulto , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Constrição Patológica/diagnóstico por imagem , Obstrução Nasal/diagnóstico por imagem , Obstrução Nasal/cirurgia , Obstrução Nasal/etiologia , Rinoplastia/métodos , Septo Nasal/diagnóstico por imagem , Septo Nasal/cirurgia , Septo Nasal/anormalidades , Seios Paranasais/diagnóstico por imagem , Seios Paranasais/cirurgia , Seios Paranasais/patologia , Adulto Jovem
2.
Skeletal Radiol ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775948

RESUMO

OBJECTIVE: To evaluate the prevalence of shoulder adhesive capsulitis (AC) signs on MR studies of patients with various common shoulder conditions. METHODS: MR images of 316 patients were retrospectively evaluated. Patients were divided into three groups: controls (66 patients), clinical AC (63 patients), and study group (187 patients). The final diagnosis of AC was reached clinically. The study group was composed of patients with focal and massive rotator cuff tears, active hydroxyapatite deposition disease, fractures around the shoulder, and post-surgery. The following AC signs were evaluated: inferior glenohumeral ligament (IGHL) thickening; coracohumeral ligament (CHL) thickening; and hyperintensity of the inferior glenohumeral ligament, which was graded in four classes. RESULTS: The IGHL signal intensity was statistically higher in patients with fractures than in controls (P = 0.008). There was no statistically significant difference in IGHL signal between the AC group and patients with massive rotator cuff tears and active hydroxyapatite deposition disease (P > 0.1). IGHL thickness in patients with fractures, massive rotator ruptures, and active hydroxyapatite deposition disease was significantly higher compared to controls (P < 0.02) and significantly lower compared to the AC group (P < 0.0001). Based on these findings, a grading system for fibro-inflammatory capsular changes is proposed. CONCLUSION: MR AC signs are frequent in patients with shoulder conditions other than AC; however, in these patients, capsular changes are less prominent than in patients with clinical AC.

3.
Can Assoc Radiol J ; 75(3): 609-619, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39086146

RESUMO

Purpose: To compare image quality and radiation exposure between super- and ultra-high-resolution helical and super-high-resolution volumetric CT of the temporal bone. Methods: Six cadaveric temporal bone specimens were used to evaluate key temporal bone structures using the following CT reconstruction and acquisition modes: helical and single-volume acquisition modes in super-high resolution (0.25-mm slice thickness, 10242 matrix), and helical mode in ultra-high resolution (0.25-mm slice thickness, 20482 matrix). Two observers performed 5 previously described preoperative measurements, measured noise and signal-to-noise ratios for air, and noise for bone, and rated the visualization of 5 anatomical structures on a 4-point scale, for each reconstruction mode. Radiation dose exposure was recorded for each examination. Results: There was no significant difference between any of the quantitative or qualitative measurements in any of the reconstruction and acquisition modes. There was a slight increase in noise and a decrease in signal-to-noise ratio in the air using the single-volume mode (115 ± 13.1 HU and 8.37 ± 0.91, respectively) compared to the helicoidal super-high-resolution (92.4 ± 11.8 HU and 10.8 ± 1.26, respectively) and helicoidal ultra-high-resolution (91.1 ± 10.7 HU and 10.9 ± 1.39, respectively) modes (P < .002). The volumic CT dose index was 50.9 mGy with helical acquisition and 29.8 mGy with single-volume acquisition mode (P < .0001). Conclusion: The single-volume super-high-resolution acquisition mode allows a reduction in radiation dose exposure without compromising image quality compared to helical scanning, but with a slightly lower signal-to-noise ratio in air with the single-volume mode, while there was no difference in image quality between the helical super- and ultra-high-resolution modes.


Assuntos
Cadáver , Doses de Radiação , Razão Sinal-Ruído , Osso Temporal , Humanos , Osso Temporal/diagnóstico por imagem , Osso Temporal/anatomia & histologia , Tomografia Computadorizada Espiral/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
4.
Radiology ; 308(3): e230193, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37698480

RESUMO

Background Initial imaging work-up using radiography and CT arthrography sometimes can be insufficient to identify a scapholunate (SL) instability (SLI) in patients suspected of having SL ligament tears. Purpose To determine the diagnostic performance of four-dimensional (4D) CT in the identification of SLI and apply the findings to patients suspected of having SLI and with inconclusive findings on radiographs and CT arthrograms. Materials and Methods This prospective single-center study enrolled participants suspected of having SLI (recent trauma, dorsal pain, positive Watson test results, decreased grip strength) between March 2015 and March 2020. Participants with wrist fractures, substantial joint stiffness, or history of wrist surgery were excluded. Each participant underwent radiography, CT arthrography, and 4D CT on the same day. Participants were divided into three groups: those with no SLI, those with SLI, and those with inconclusive results. SL gap and radioscaphoid and lunocapitate angle were measured using semiautomatic quantitative analysis of 4D CT images by two independent readers. Receiver operating characteristic curves were used to evaluate the diagnostic performance of 4D CT. Thresholds were determined with the Youden index and were applied to the inconclusive group. Results Of the 150 included participants (mean age, 41 years ± 14 [SD]; 102 male, 48 female), there were 63 with no SLI, 48 with SLI, and 39 with inconclusive results. The maximum value and range of SL gap measurements on 4D CT scans showed high sensitivity (83% [40 of 48] and 90% [43 of 48], respectively) and high specificity (95% [59 of 62] and 81% [50 of 62], respectively) in the identification of SLI. At least one of these parameters was abnormal on 4D CT scans in 17 of 39 (44%) participants in the inconclusive group, and 10 of 17 (59%) participants had confirmed SLI. In the 22 participants in the inconclusive group with no indication of SLI at 4D CT, follow-up showed no evidence of SLI in 10 (45%) and enabled confirmation of SLI via arthroscopy in three (14%). Conclusion Scapholunate gap measurements on kinematic 4D CT scans enabled correct identification of SLI in 59% of participants with inconclusive results on conventional images. ClinicalTrials.gov registration no. NCT02401568 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Demehri and Ibad in this issue.


Assuntos
Tomografia Computadorizada Quadridimensional , Fraturas Ósseas , Humanos , Feminino , Masculino , Adulto , Estudos Prospectivos , Artroscopia , Ligamentos Articulares
5.
Eur Radiol ; 33(1): 106-115, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35776181

RESUMO

OBJECTIVES: To study the relationship between opportunistic CT bone density measurements and the occurrence of new vertebral fractures after percutaneous vertebral cementoplasty (PVC) of osteoporotic vertebral compression fractures (OVCF). METHODS: A prospective analysis of retrospective data of 275 patients with OVCF treated by PVC between 2014 and 2019 with a clinico-radiological follow-up one year after treatment was conducted. Opportunistic bone density measurements were obtained at the trabecular bone of the L1 or an adjacent vertebra in Hounsfield units performed on the preoperative CT study. These density measurements values ​​were then compared between patients with and without new OCVF and in various population subgroups. RESULTS: There were 275 patients included, with 53 (19%) presenting a new OCVF and 24 (9%) developing a fracture cascade. The median opportunistic density measurements ​​in patients with recurrent OCVF were lower than those without (median 52[40.5]) HU and 77[49] HU)(p < 0.00001). Among the patients with new OVCF the median opportunistic density measurements in patients with fracture cascades were also lower than those without (44 HU and 62 HU, respectively) (p < 0.0096). Patients with density measurements under 61 HU were 3.6 times more likely to present recurrent fractures and those with density under 54 HU were 9.8 times more likely to develop a fracture cascade. The 36 HU threshold yielded a high specificity (90-91%) for the prediction of recurrent fractures and fracture cascade but with low sensitivity (respectively 26% and 37%). CONCLUSION: Low opportunistic vertebral density measurements are associated with a higher risk of OVCF and fracture cascades after PVC. KEY POINTS: • Low opportunistic density measurements are associated with a higher risk of OVCF and fracture cascades after PVC. • Measuring bone density before performing a PVC could help predict the risk of new vertebral fracture after treatment • Patient management could be adapted according to bone density.


Assuntos
Doenças Ósseas Metabólicas , Cementoplastia , Fraturas por Compressão , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Densidade Óssea , Estudos de Casos e Controles , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Vértebras Lombares/lesões , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia
6.
Eur Radiol ; 33(9): 6381-6391, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37014406

RESUMO

OBJECTIVE: To compare the diagnostic performance of standard MRI and standard MRI + ZTE images for the detection of rotator cuff calcific tendinopathy (RCCT) and to describe the artifacts encountered with ZTE images, using computed radiography (CR) as a reference. METHODS: In a retrospective study, patients with suspicion of rotator cuff tendinopathy who underwent standard MRI + ZTE images after radiography were enrolled between June 2021 and June 2022. Images were independently analyzed for calcific deposit presence and ZTE images artifacts, by two radiologists. Diagnostic performance was calculated individually with MRI + CR as the reference standard. RESULTS: A total of 46 RCCT subjects (27 women; mean age, 55.3 years ± 12.4) and 51 control subjects (27 men; mean age, 45.5 ± 12.9) were evaluated. For both readers, there was an increase in the sensitivity for the identification of calcific deposits of MRI + ZTE compared to MRI (77% (95% CI: 64.5-86.8) and 75.4% (95% CI: 62.7-85.5) versus 57.4% (95% IC: 44.1-70) and 47.5% (95% IC: 34.6-60.7), for R1 and R2, respectively). Specificity was quite similar for both readers and both imaging techniques and ranged from 96.6% (95% IC: 93.3-98.5) to 98.7% (95% IC: 96.3-99.7). Hyperintense joint fluid (62.8% of patients), long head of the biceps tendon (in 60.8%), and subacromial bursa (in 27.8%) on ZTE were considered artifactual. CONCLUSION: The addition of ZTE images to a standard MRI protocol improved MRI diagnostic performance of RCCT, but with a suboptimal detection rate and a relatively high frequency of artifactual soft tissue signal hyperintensity. KEY POINTS: • Adding ZTE images to standard shoulder MRI improves the MR-based detection of rotator cuff calcific tendinopathy, but half of the calcification unseen with standard MRI remained unseen with ZTE MRI. On ZTE images, joint fluid and long head biceps tendon were hyperintense in about 60% of the shoulders, as well as the subacromial bursa in about 30%, without calcific deposit on conventional radiographs. • The detection rate of calcific deposits using ZTE images was dependent on the disease phase. In the calcific stage, it reached 100% in this study but remained at a maximum of 80.7% in the resorptive phase.


Assuntos
Manguito Rotador , Tendinopatia , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Manguito Rotador/diagnóstico por imagem , Ombro , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Radiografia , Tendinopatia/diagnóstico por imagem
7.
Eur Radiol ; 33(4): 2340-2349, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36394602

RESUMO

OBJECTIVE: To evaluate the MRI perfusion changes in patients with risk factors for osteonecrosis and normally appearing femoral heads prior to overt femoral head osteonecrosis. METHODS: Fifty-eight patients (105 hips) were prospectively included in this ethics committee-approved study. There were 46 hips with no image anomalies and no risk factors for osteonecrosis of the femoral head (ONFH) risk factors, 38 with ONFH risk factors and no image abnormalities, and 21 with overt ONFH. All patients underwent DCE-MRI. Semi-quantitative (peak enhancement [PE], area under the curve [AUC], time to maximum enhancement [TME]) and quantitative perfusion parameters (volume plasma, KTRANS, and KEP) were calculated. Excessive alcohol consumption, corticosteroid use, and trauma were considered major risk factors for osteonecrosis of the femoral head. RESULTS: Measured at the femoral neck and compared to the healthy hips without OFNH risk factors, PE was significantly lower in the hips of patients with OFNH risk factors. Moreover, the difference was greater in females with risk factors, who presented significantly lower PE values (p = 0.0096). A PE threshold of 1.4% yielded a 92% sensitivity and 54% specificity for the presence of associated ONFH risk factors. The hips with overt OFNH compared to those with normally appearing showed an increase of PE of 45% in the neck (p < 0.014). Various epiphyseal femoral head perfusion parameters (PE, TME, AUC, and Ktrans) presented statistically significant differences in hips with ONFH and those without (p < 0.0001). CONCLUSION: DCE-MRI can identify perfusion marrow changes related to the presence of ONFH risk factors and adjacent to osteonecrosis areas. KEY POINTS: • Bone marrow perfusion changes may occur prior to overt ONFH and extend beyond the osteonecrosis area to the entire femoral head and neck. • Peak enhancement values were significantly reduced in patients with ONFH risk factors, compared to those without. • The presence of ONFH led to a significant increase in marrow perfusion adjacent to the osteonecrosis area.


Assuntos
Necrose da Cabeça do Fêmur , Cabeça do Fêmur , Feminino , Humanos , Masculino , Cabeça do Fêmur/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Perfusão , Imageamento por Ressonância Magnética/métodos
8.
Semin Musculoskelet Radiol ; 27(4): 397-410, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37748463

RESUMO

Bone microarchitecture has several clinical implications over and above estimating bone strength. Computed tomography (CT) analysis mainly uses high-resolution peripheral quantitative CT and micro-CT, research imaging techniques, most often limited to peripheral skeleton assessment. Ultra-high-resolution (UHR) CT and photon-counting detector CT, two commercially available techniques, provide images that can approach the spatial resolution of the trabeculae, bringing bone microarchitecture analysis into clinical practice and improving depiction of bone vascularization, tumor matrix, and cortical and periosteal bone. This review presents bone microarchitecture anatomy, principles of analysis, reference measurements, and an update on the performance and potential clinical applications of these new CT techniques. We also share our clinical experience and technical considerations using an UHR-CT device.


Assuntos
Osso Esponjoso , Tomografia Computadorizada por Raios X , Humanos , Compostos Radiofarmacêuticos
9.
Semin Musculoskelet Radiol ; 27(4): 471-479, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37748471

RESUMO

Focal bone lesions are frequent, and management greatly depends on the characteristics of their images. After briefly discussing the required work-up, we analyze the most relevant imaging signs for assessing potential aggressiveness. We also describe the imaging aspects of the various types of lesion matrices and their clinical implications.


Assuntos
Doenças Ósseas , Doenças das Cartilagens , Humanos
10.
Can Assoc Radiol J ; 74(2): 404-414, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36207066

RESUMO

Objectives: To ascertain the role of CT and conventional radiographs for the initial characterization of focal bone lesions.Methods: Images from 184 patients with confirmed bone tumors included in an ethics committee-approved study were retrospectively evaluated. The reference for benign-malignant distribution was based on histological analysis and long-term follow-up. Radiographs and CT features were analyzed by 2 independent musculoskeletal radiologists blinded to the final diagnosis. Lesion margins, periosteal reaction, cortical lysis, endosteal scalloping, presence of pathologic fracture, and lesion mineralization were evaluated. Results: The benign-malignant distribution in the study population was 68.5-31.5% (126 benign and 58 malignant). In the lesions that could be seen in both radiographs and CT, the performance of these methods for the benign-malignant differentiation was similar (accuracy varying from 72.8% to 76.5%). The interobserver agreement for the overall evaluation of lesion aggressiveness was considerably increased on CT compared to radiographs (Kappa of .63 vs .22). With conventional radiographs, 18 (9.7%) and 20 (10.8%) of the lesions evaluated were not seen respectively by readers 1 and 2. Among these unseen lesions, 50%-61.1% were located in the axial skeleton. Compared to radiographs, the number of lesions with cortical lysis and endosteal scalloping was 26-34% higher with CT. Conclusion: Although radiographs remain the primary imaging tool for lesions in the peripheral skeleton, CT should be performed for axial lesions. CT imaging can assess the extent of perilesional bone lysis more precisely than radiographs with a better evaluation of lesion fracture risk.


Assuntos
Neoplasias Ósseas , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Variações Dependentes do Observador , Tomografia Computadorizada por Raios X/métodos , Neoplasias Ósseas/diagnóstico por imagem , Radiografia
11.
Eur Radiol ; 32(5): 3161-3172, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34989850

RESUMO

OBJECTIVE: To evaluate the image quality and clinical acceptance of a deep learning reconstruction (DLR) algorithm compared to traditional iterative reconstruction (IR) algorithms. METHODS: CT acquisitions were performed with two phantoms and a total of nine dose levels. Images were reconstructed with two types of IR algorithms, DLR and filtered-back projection. Spatial resolution, image texture, mean noise value, and objective and subjective low-contrast detectability were compared. Ten senior radiologists evaluated the clinical acceptance of these algorithms by scoring ten CT exams reconstructed with the DLR and IR algorithms evaluated. RESULTS: Compared to MBIR, DLR yielded a lower noise and a higher low-contrast detectability index at low doses (CTDIvol ≤ 2.2 and ≤ 4.5 mGy, respectively). Spatial resolution and detectability at higher doses were better with MBIR. Compared to HIR, DLR yielded a higher spatial resolution, a lower noise, and a higher detectability index. Despite these differences in algorithm performance, significant differences in subjective low-contrast performance were not found (p ≥ 0.005). DLR texture was finer than that of MBIR and closer to that of HIR. Radiologists preferred DLR images for all criteria assessed (p < 0.0001), whereas MBIR was rated worse than HIR (p < 0.0001) in all criteria evaluated, except for noise (p = 0.044). DLR reconstruction time was 12 times faster than that of MBIR. CONCLUSION: DLR yielded a gain in objective detection and noise at lower dose levels with the best clinical acceptance among the evaluated reconstruction algorithms. KEY POINTS: • DLR yielded improved objective low-contrast detection and noise at lower dose levels. • Despite the differences in objective detectability among the algorithms evaluated, there were no differences in subjective detectability. • DLR presented significantly higher clinical acceptability scores compared to MBIR and HIR.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
12.
Eur Radiol ; 32(11): 7590-7600, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35445824

RESUMO

OBJECTIVES: To compare the diagnostic performance of scapholunate gap (SLG) measurements acquired with dart throwing (DT), radio-ulnar deviation (RUD), and clenching fist (CF) maneuvers on 4D CT for the identification of scapholunate instability. METHODS: In this prospective study, 47 patients with suspected scapholunate interosseous ligament (SLIL) tears were evaluated from March 2015 to March 2020 with semiautomatic quantitative analysis on 4D CT. Five parameters (median, maximal value, range, and coefficient of variation) for SLG, lunocapitate angle (LCA), and radioscaphoid angle (RSA) obtained during DT maneuver were evaluated in patients with and without SLIL tears. CT arthrography was used as the gold standard for the SLIL status. The SLG values obtained were also compared with those obtained during CF and RUD maneuvers. RESULTS: Significant differences in all SLG- and LCA-derived parameters are found between patients with and without SLIL tears with DT (p < 0.003). The best diagnostic performance for the diagnosis of SLIL tears was obtained with median and maximal SLG values (sensitivity and specificity of 86-89% and 95%) and with maximal and range LCA values (sensitivity and specificity of 86% and 74%). No significant differences were observed for RSA values (p > 0.275). The SLG range obtained with DT maneuver was the only dynamic parameter statistically different between patients with partial and complete torn SLIL (p = 0.037). CONCLUSION: 4D CT of the wrist during DT showed a similar performance than RUD and a better performance than CF for the differentiation between patients with and without SLIL tears. KEY POINTS: • Four-dimensional computed tomography can dynamically assess scapholunate instability. • The best results for differentiating between patients with and without SLIL tears were obtained with SLG median and maximal values. • The dart throwing and radio-ulnar deviation maneuvers yielded the best results for the dynamic evaluation of scapholunate instability.


Assuntos
Osso Escafoide , Traumatismos do Punho , Humanos , Tomografia Computadorizada Quadridimensional , Traumatismos do Punho/diagnóstico por imagem , Fenômenos Biomecânicos , Punho , Estudos de Casos e Controles , Estudos Prospectivos , Articulação do Punho/diagnóstico por imagem , Ligamentos Articulares
13.
Surg Radiol Anat ; 44(10): 1367-1374, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36208337

RESUMO

PURPOSE: To study the anatomy of the latero-lateral joint (LLJ) between the upper lateral (ULC) and lower lateral (LLC) crus of the nasal cartilages, usually described as a scroll articulation. METHODOLOGY: Six nasal pyramids were taken in monobloc from fresh cadavers and imaged on micro-MRI with 0.4 mm slice thickness. Images were jointly interpreted by two head and neck radiologists and one surgeon. The junction between the ULC and LLC, the presence of ligaments and of sesamoid or accessory cartilages were assessed. RESULTS: Eight LLJs could be analyzed, with four types of junctions: hook-shaped cephalic border of the LLC turned towards the nasal fossa and linear caudal border of the ULC (n = 3), hook-shaped caudal border of the ULC and linear cephalic border of the LLC lateral crus (n = 1), hook-shaped border of both cartilaginous edges with clinging (n = 1) (scroll articulation) or without clinging (n = 3). No ligament or sesamoid cartilage was found, but posterior accessory cartilages were seen in 75% of the cases. CONCLUSION: The classical scroll articulation of the LLJ has been observed in only 1/8 cases on micro-MRI images. The anatomy of the LLJ could explain the surgical difficulty in raising the tip of the nose in some patients and not in others.


Assuntos
Cartilagens Nasais , Rinoplastia , Humanos , Cartilagens Nasais/diagnóstico por imagem , Cartilagens Nasais/anatomia & histologia , Rinoplastia/métodos , Nariz/diagnóstico por imagem , Nariz/anatomia & histologia , Ligamentos/cirurgia , Imageamento por Ressonância Magnética , Septo Nasal/cirurgia
14.
Eur Radiol ; 31(10): 7637-7652, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33765161

RESUMO

OBJECTIVES: Identify the most pertinent imaging features for solitary bone tumor characterization using a multimodality approach and propose a systematic evaluation system. METHODS: Data from a prospective trial, including 230 participants with histologically confirmed bone tumors, typical "do not touch" lesions, and stable chondral lesions, were retrospectively evaluated. Clinical data, CT, and MR imaging features were analyzed by a musculoskeletal radiologist blinded to the diagnosis using a structured report. The benign-malignant distribution of lesions bearing each image feature evaluated was compared to the benign-malignant distribution in the study sample. Benign and malignant indicators were identified. Two additional readers with different expertise levels independently evaluated the study sample. RESULTS: The sample included 140 men and 90 women (mean age 40.7 ± 18.3 years). The global benign-malignant distribution was 67-33%. Seven imaging features reached the criteria for benign indicators with a mean frequency of benignancy of 94%. Six minor malignant indicators were identified with a mean frequency of malignancy of 60.5%. Finally, three major malignant indicators were identified (Lodwick-Madewell grade III, aggressive periosteal reaction, and suspected metastatic disease) with a mean frequency of malignancy of 82.4%. A bone tumor imaging reporting and data system (BTI-RADS) was proposed. The reproducibility of the BTI-RADS was considered fair (kappa = 0.67) with a mean frequency of malignancy in classes I, II, III, and IV of 0%, 2.2%, 20.1%, and 71%, respectively. CONCLUSION: BTI-RADS is an evidence-based systematic approach to solitary bone tumor characterization with a fair reproducibility, allowing lesion stratification in classes of increasing malignancy frequency. TRIAL REGISTRATION: Clinical trial number NCT02895633 . KEY POINTS: • The most pertinent CT and MRI criteria allowing bone tumor characterization were defined and presented. • Lodwick-Madewell grade III, aggressive periosteal reaction, and suspected metastatic disease should be considered major malignant indicators associated with a frequency of malignancy over 75%. • The proposed evidence-based multimodality reporting system stratifies solitary bone tumors in classes with increasing frequencies of malignancy.


Assuntos
Neoplasias Ósseas , Tomografia Computadorizada por Raios X , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
15.
Eur Radiol ; 30(9): 5200-5208, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32333147

RESUMO

OBJECTIVE: To evaluate the use of two alternative picture archiving and communication systems (PACS) interface devices (a graphics tablet and a handheld controller) in clinical practice and on task-oriented exercises. MATERIAL AND METHODS: Eleven senior radiologists were prospectively evaluated. The participants used the two tested interface devices for 10 working periods each and answered a questionnaire to evaluate the ergonomics of this experience. The prevalence of work-related musculoskeletal discomfort with the standard PACS interface set (mouse-keyboard-recording device) and these two devices was assessed. Exercises evaluating image scrolling and selection, image zooming and panning, image windowing, performing measurements, and reporting were performed with the standard PACS interface set and with the two tested devices. The sitting posture and hand position were evaluated. RESULTS: The general appreciation of the two alternative interface devices was considered to be similar to that of the standard interface set. The ergonomics of the handheld controller was considered to be slightly better than that of the standard interface set. The prevalence of musculoskeletal discomfort was 81%, 45%, and 18% for the standard interface set, graphics tablet, and handheld controller, respectively. With the graphics tablet and the handheld controller in 45% and 60%, respectively, there was a working posture change with respect to the standard interface set. The mean total exercise completion times of both tested devices were 27% higher than that of the standard interface set. CONCLUSION: Despite the increase in completion time of the task-oriented exercises, the tested devices were well accepted and considered to be more comfortable than the standard set. KEY POINTS: • Alternative PACS interface devices can be used as a substitute for the standard mouse-keyboard-recording device set with a potential improvement in work ergonomics and a reduction in work-related musculoskeletal discomfort.


Assuntos
Ergonomia , Postura , Radiologistas , Sistemas de Informação em Radiologia , Adulto , Atitude do Pessoal de Saúde , Periféricos de Computador , Computadores de Mão , Feminino , Humanos , Masculino , Dor Musculoesquelética , Saúde Ocupacional , Fatores de Tempo , Interface Usuário-Computador
16.
Eur Radiol ; 30(10): 5690-5701, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32361774

RESUMO

OBJECTIVES: To establish national reference levels (RLs) in interventional procedures under CT guidance as required by the 2013/59/Euratom European Directive. METHODS: Seventeen categories of interventional procedures in thoracic, abdominopelvic, and osteoarticular specialties (percutaneous infiltration, vertebroplasty, biopsy, drainage, tumor destruction) were analyzed. Total dose length product (DLP), number of helical acquisitions (NH), and total DLP for helical, sequential, or fluoroscopic acquisitions were recorded for 10 to 20 patients per procedure at each center. RLs were calculated as the 3rd quartiles of the distributions and target values for optimization process (TVOs) as the median. RLs and TVOs were compared with previously published studies. RESULTS: Results on 5001 procedures from 49 centers confirmed the great variability in patient dose for the same category of procedures. RLs were proposed for the DLPs and NHs in the seventeen categories. RLs in terms of DLP and NH were 375 mGy.cm and 2 NH for spinal or peri-spinal infiltration, 1630 mGy.cm and 3 NH for vertebroplasty, 845 mGy.cm and 4 NH for biopsy, 1950 mGy.cm and 8 NH for destruction of tumors, and 1090 mGy.cm and 5 NH for drainage. DLP and NH increased with the complexity of procedures. CONCLUSIONS: This study was the first nationwide multicentric survey to propose RLs for interventional procedures under CT guidance. Heterogeneity of practice in centers were found with different levels of patient doses for the same procedure. The proposed RLs will allow imaging departments to benchmark their practice with others and optimize their protocols. KEY POINTS: • National reference levels are proposed for 17 categories of interventional procedures under CT guidance. • Reference levels are useful for benchmarking practices and optimizing protocols. • Reference levels are proposed for dose length product and the number of helical acquisitions.


Assuntos
Doses de Radiação , Radiografia Intervencionista/normas , Valores de Referência , Tomografia Computadorizada por Raios X/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Fluoroscopia/métodos , França , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Coluna Vertebral , Inquéritos e Questionários , Tomografia Computadorizada por Raios X/métodos , Vertebroplastia , Adulto Jovem
18.
Skeletal Radiol ; 49(12): 1889-1901, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32583133

RESUMO

A wide variety of pathologies can affect the hallux sesamoid complex of the foot, including traumatic, micro traumatic, degenerative, inflammatory, vascular, infectious, and neoplastic conditions. Symptoms are quite nonspecific, mainly related to pain in the plantar surface of the first metatarsal head. In this context, imaging is important for the etiologic diagnosis of hallux sesamoid complex pathology with implications in patient management. The hallux sesamoid complex has a complex anatomy, and pathologic processes of this region are poorly known of radiologists. Besides, some entities such as "sesamoiditis" remain poorly defined in the literature. Schematically, conditions affecting sesamoids will be divided into two major groups: intrinsic anomalies (sesamoid bone being the center of the pathologic process) and extrinsic anomalies (diseases secondarily involving sesamoid bones). Thus, in this article, after a review of anatomical key points and pathologies affecting the hallux sesamoid complex, a practical multimodality approach for the diagnosis of hallux sesamoid pathologies will be proposed.


Assuntos
Hallux , Ossos do Metatarso , Ossos Sesamoides , Epífises , Humanos , Dor , Ossos Sesamoides/diagnóstico por imagem
19.
Eur Radiol ; 29(3): 1258-1266, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30194473

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of digital tomosynthesis (DTS) for the diagnosis of hip prosthesis loosening (PL) compared with conventional radiographs and CT with metal artifact reduction (CT-MAR). METHODS: Forty-nine patients with painful hip prosthesis were prospectively included and underwent anteroposterior and lateral radiographs, anteroposterior DTS and CT-MAR of the hip. This study was approved by the local ethics committee, and all patients signed an informed consent form. Images were evaluated independently by two radiologists. Periprosthetic radiolucent lines wider than 2 mm found in two or more Gruen or De Lee and Charnley zones were considered diagnostic of PL. All cases of PL were confirmed surgically. Patients with a stable radiological follow-up for at least 1 year with an alternative cause for the symptoms or with no surgical evidence of PL were considered PL negative. RESULTS: There were 21 cases of PL, 9 unilateral and 12 bilateral. For both the acetabular and femoral sides, DTS had a specificity for PL detection similar to that of conventional radiographs and CT-MAR (98.5-100%, 96.9%-100% and 96.9-95.4% respectively for both readers) and a sensitivity similar to conventional radiographs (39.9-45.4% versus 33.3-51.5% for both readers) but lower than CT-MAR (84.85% for both readers). The interobserver agreement was 0.84 for CT-MAR, 0.53 for DTS and 0.39 for conventional radiographs. CONCLUSION: DTS has a similar diagnostic performance to radiographs for the diagnosis of PL with a better interobserver agreement. The sensitivity however remains lower than that of CT-MAR. KEY POINTS: • Plain radiograph is still the first imaging step when hip prosthesis loosening is suspected. • Interobserver agreement is better with digital tomosynthesis than radiographs. • Sensitivity of CT with state-of-the-art metal artifact reduction is superior to that of digital tomosynthesis.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/métodos , Artefatos , Fêmur/diagnóstico por imagem , Prótese de Quadril , Tomografia Computadorizada Multidetectores/métodos , Radiografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA