Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Ophthalmic Plast Reconstr Surg ; 32(4): 257-60, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25906332

RESUMO

PURPOSE: The aim of this study was to look at the surgical outcomes of posterior approach Mullers muscle conjunctival resection surgery for contact lens-related ptosis. METHODS: This was a retrospective, comparative interventional case series. All patients and controls underwent phenylephrine 10% testing and had a positive response prior to surgical intervention. RESULTS: Thirty-one eyelids with ptosis were identified in 20 contact lens wearing patients, which were matched with 27 eyelids in 15 controls. The contact lens wearing patients wore contact lenses for a mean of 20.6 ± 12.1 years. More than half (60%) wore soft contact lenses, as opposed to rigid gas-permeable contact lenses. Preoperative margin-to-reflex distance-1 was lower in patients who wore rigid contact lenses (0.8 ± 0.7 mm) as compared with patients with soft contact lenses (1.7 ± 1.1 mm) (p = 0.01). Surgical success, as defined by margin-to-reflex distance-1 ≥3 mm or symmetry of upper eyelid height (within 1 mm), was achieved in 93.5% in the contact lens group and 92.6% of controls. Postoperative margin-to-reflex distance-1 was significantly higher in the contact lens wearers (3.9 ± 1.3 mm) compared with the controls (3.2 ± 1.1 mm; p = 0.01). There was a significant correlation between the amount of tissue resected intraoperatively and the improvement in margin-to-reflex distance-1 (Pearsons correlation coefficient, r =0.36; p = 0.006). There were no surgical complications of any patients in the study. CONCLUSION: Mullers muscle conjunctival resection surgery is an effective surgical correction for contact lens-associated ptosis. Patients can achieve excellent results with minimal risk of residual ptosis or asymmetry.


Assuntos
Blefaroplastia/métodos , Blefaroptose/cirurgia , Túnica Conjuntiva/cirurgia , Lentes de Contato/efeitos adversos , Pálpebras/cirurgia , Músculos Oculomotores/cirurgia , Adulto , Blefaroptose/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
2.
J Glaucoma ; 32(6): 533-539, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36897654

RESUMO

PRCIS: Remote contrast sensitivity (CS) testing through a free downloadable home test correlates with glaucomatous macular damage measured by 10-2 visual field (VF) testing. PURPOSE: To assess the feasibility and validity of home CS monitoring as a measure of glaucomatous damage using a free downloadable smartphone application. METHODS: Twenty-six participants were asked to remotely use the Berkeley Contrast Squares (BCS) application, a free downloadable tool that records the user's CS for varying degrees of visual acuity. An instructional video detailing how to download and use the application was sent to the participants. Subjects were asked to send logarithmic CS results with a minimum 8-week test-retest window, and test-retest reliability was measured. Results were validated against office-based CS testing that was collected within the previous 6 months. Validity analysis was also carried out to determine whether CS as measured by BCS is a good predictor of 10-2 and 24-2 VF mean deviation (MD). RESULTS: There was a high BCS test-retest reliability with an intraclass correlation coefficient score of 0.91 and a significant correlation between repeat test results and baseline test scores (Pearson, 0.86, P < 0.0001). There was significant agreement between unilateral CS scores as measured by BCS and office-based CS testing ( b = 0.94, P < 0.0001, 95% CI: 0.61 to 1.27). Unilateral CS as measured by BCS was significantly associated with 10-2 VF MD ( r2 = 0.27, P = 0.006, 95% CI: 3.7 to 20.6), but not with 24-2 VF MD ( P = 0.151). CONCLUSION: This study suggests that a free, rapid home CS test correlates with glaucomatous macular damage as measured by 10-2 VF.


Assuntos
Glaucoma , Campos Visuais , Humanos , Sensibilidades de Contraste , Reprodutibilidade dos Testes , Pressão Intraocular , Glaucoma/diagnóstico , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA