Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610390

RESUMO

One of the effective methods of non-destructive testing of structures is active vibration diagnostics. This approach consists of the local dynamic impact of the actuator on the structure and the registration of the vibration response. Testing of massive reinforced concrete structures is carried out with the use of actuators, which are able to create sufficiently high-impact loads. The actuators, which are based on piezoelectric elements, cannot provide a sufficient level of force and the areas where it is possible to register the vibrations excited by such actuators are quite small. In this paper, we propose a variant of a piezoactuator with attached mass, which ensures an increase in the level of dynamic impact on the structure. The effectiveness of this version is verified by numerical modeling of the dynamic interaction of the actuator with a concrete slab. The simulation was carried out within the framework of the theory of elasticity and coupled electroelasticity. An algorithm for selecting the value of the attached mass is described. It is shown that when vibrations are excited in a massive concrete slab, an actuator with an attached mass of 1.3 kg provides a 10,000-fold increase in the force compared to an actuator without attached mass. In the pulse mode, a 100-fold increase in force is achieved.

2.
Polymers (Basel) ; 16(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38201743

RESUMO

Polymer materials are widely used in medicine due to their mechanical properties and biological inertness. When ion-plasma treatment is used on a polymer material, a carbonization process occurs in the surface nanolayer of the polymer sample. As a result, a surface carbonized nanolayer is formed, which has mechanical properties different from those of the substrate. This layer has good biocompatibility. The formation of a carbonized nanolayer on the surface of polymer implants makes it possible to reduce the body's reaction to a foreign body. Typically, to study the properties of a carbonized layer, flat polymer samples are used, which are treated with an ion flow perpendicular to the surface. But medical endoprostheses often have a curved surface, so ion-plasma treatment can occur at different angles to the surface. This paper presents the results of a study of the morphological and mechanical properties of a carbonized layer formed on a polyurethane surface. The dependence of these properties on the directional angle of the ion flow and its fluence has been established. To study the surface morphology and elastic properties, methods of atomic force microscopy and methods of elasticity theory were used. The strength properties of the carbonized layer were studied using a stretching device combined with a digital optical microscope.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA