Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Emerg Med ; 78: 112-119, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38244244

RESUMO

OBJECTIVES: In the Emergency Department (ED), ultrasound-guided nerve blocks (UGNBs) have become a cornerstone of multimodal pain regimens. We investigated current national practices of UGNBs across academic medical center EDs, and how these trends have changed over time. METHODS: We conducted a cross-sectional electronic survey of academic EDs with ultrasound fellowships across the United States. Twenty-item questionnaires exploring UGNB practice patterns, training, and complications were distributed between November 2021-June 2022. Data was manually curated, and descriptive statistics were performed. The survey results were then compared to results from Amini et al. 2016 UGNB survey to identify trends. RESULTS: The response rate was 80.5% (87 of 108 programs). One hundred percent of responding programs perform UGNB at their institutions, with 29% (95% confidence interval (CI), 20%-39%) performing at least 5 blocks monthly. Forearm UGNB are most commonly performed (96% of programs (95% CI, 93%-100%)). Pain control for fractures is the most common indication (84%; 95% CI, 76%-91%). Eighty-five percent (95% CI, 77%-92%) of programs report at least 80% of UGNB performed are effective. Eighty-five percent (95% CI, 66%-85%) of programs have had no reported complications from UGNB performed by emergency providers at their institution. The remaining 15% (95% CI, 8%-23%) report an average of 1 complication annually. CONCLUSIONS: All programs participating in our study report performing UGNB in their ED, which is a 16% increase over the last 5 years. UGNB's are currently performed safely and effectively in the ED, however practice improvements can still be made. Creating multi-disciplinary committees at local and national levels can standardize guidelines and practice policies to optimize patient safety and outcomes.


Assuntos
Medicina de Emergência , Bloqueio Nervoso , Humanos , Estados Unidos , Estudos Transversais , Bloqueio Nervoso/métodos , Ultrassonografia , Serviço Hospitalar de Emergência , Dor , Ultrassonografia de Intervenção/métodos
2.
J Med Internet Res ; 26: e51397, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963923

RESUMO

BACKGROUND: Machine learning (ML) models can yield faster and more accurate medical diagnoses; however, developing ML models is limited by a lack of high-quality labeled training data. Crowdsourced labeling is a potential solution but can be constrained by concerns about label quality. OBJECTIVE: This study aims to examine whether a gamified crowdsourcing platform with continuous performance assessment, user feedback, and performance-based incentives could produce expert-quality labels on medical imaging data. METHODS: In this diagnostic comparison study, 2384 lung ultrasound clips were retrospectively collected from 203 emergency department patients. A total of 6 lung ultrasound experts classified 393 of these clips as having no B-lines, one or more discrete B-lines, or confluent B-lines to create 2 sets of reference standard data sets (195 training clips and 198 test clips). Sets were respectively used to (1) train users on a gamified crowdsourcing platform and (2) compare the concordance of the resulting crowd labels to the concordance of individual experts to reference standards. Crowd opinions were sourced from DiagnosUs (Centaur Labs) iOS app users over 8 days, filtered based on past performance, aggregated using majority rule, and analyzed for label concordance compared with a hold-out test set of expert-labeled clips. The primary outcome was comparing the labeling concordance of collated crowd opinions to trained experts in classifying B-lines on lung ultrasound clips. RESULTS: Our clinical data set included patients with a mean age of 60.0 (SD 19.0) years; 105 (51.7%) patients were female and 114 (56.1%) patients were White. Over the 195 training clips, the expert-consensus label distribution was 114 (58%) no B-lines, 56 (29%) discrete B-lines, and 25 (13%) confluent B-lines. Over the 198 test clips, expert-consensus label distribution was 138 (70%) no B-lines, 36 (18%) discrete B-lines, and 24 (12%) confluent B-lines. In total, 99,238 opinions were collected from 426 unique users. On a test set of 198 clips, the mean labeling concordance of individual experts relative to the reference standard was 85.0% (SE 2.0), compared with 87.9% crowdsourced label concordance (P=.15). When individual experts' opinions were compared with reference standard labels created by majority vote excluding their own opinion, crowd concordance was higher than the mean concordance of individual experts to reference standards (87.4% vs 80.8%, SE 1.6 for expert concordance; P<.001). Clips with discrete B-lines had the most disagreement from both the crowd consensus and individual experts with the expert consensus. Using randomly sampled subsets of crowd opinions, 7 quality-filtered opinions were sufficient to achieve near the maximum crowd concordance. CONCLUSIONS: Crowdsourced labels for B-line classification on lung ultrasound clips via a gamified approach achieved expert-level accuracy. This suggests a strategic role for gamified crowdsourcing in efficiently generating labeled image data sets for training ML systems.


Assuntos
Crowdsourcing , Pulmão , Ultrassonografia , Crowdsourcing/métodos , Humanos , Ultrassonografia/métodos , Ultrassonografia/normas , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Feminino , Masculino , Aprendizado de Máquina , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Am J Emerg Med ; 74: 41-48, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37769445

RESUMO

OBJECTIVES: Non-contrast computed tomography (NCCT) is the gold standard for nephrolithiasis evaluation in the emergency department (ED). However, Choosing Wisely guidelines recommend against ordering NCCT for patients with suspected nephrolithiasis who are <50 years old with a history of kidney stones. Our primary objective was to estimate the national annual cost savings from using a point-of-care ultrasound (POCUS)-first approach for patients with suspected nephrolithiasis meeting Choosing Wisely criteria. Our secondary objectives were to estimate reductions in ED length of stay (LOS) and preventable radiation exposure. METHODS: We created a Monte Carlo simulation using available estimates for the frequency of ED visits for nephrolithiasis and eligibility for a POCUS-first approach. The study population included all ED patients diagnosed with nephrolithiasis. Based on 1000 trials of our simulation, we estimated national cost savings in averted advanced imaging from this strategy. We applied the same model to estimate the reduction in ED LOS and preventable radiation exposure. RESULTS: Using this model, we estimate a POCUS-first approach for evaluating nephrolithiasis meeting Choosing Wisely guidelines to save a mean (±SD) of $16.5 million (±$2.1 million) by avoiding 159,000 (±18,000) NCCT scans annually. This resulted in a national cumulative decrease of 166,000 (±165,000) annual bed-hours in ED LOS. Additionally, this resulted in a national cumulative reduction in radiation exposure of 1.9 million person-mSv, which could potentially prevent 232 (±81) excess cancer cases and 118 (±43) excess cancer deaths annually. CONCLUSION: If adopted widely, a POCUS-first approach for suspected nephrolithiasis in patients meeting Choosing Wisely criteria could yield significant national cost savings and a reduction in ED LOS and preventable radiation exposure. Further research is needed to explore the barriers to widespread adoption of this clinical workflow as well as the benefits of a POCUS-first approach in other patient populations.


Assuntos
Cálculos Renais , Neoplasias , Humanos , Pessoa de Meia-Idade , Tempo de Internação , Redução de Custos , Método de Monte Carlo , Serviço Hospitalar de Emergência , Ultrassonografia/métodos
4.
J Emerg Med ; 60(4): 512-516, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33339647

RESUMO

BACKGROUND: Adequate analgesia is difficult to achieve in patients with an abscess requiring incision and drainage (I&D). There has been a recent increase in regional anesthesia use in the emergency department (ED) to aid in acute musculoskeletal pain relief. Specifically, transgluteal sciatic nerve (TGSN) block has been used as an adjunct treatment for certain chronic lumbar and lower extremity pain syndromes in the ED. CASE REPORT: A 21-year-old woman presented to the ED with a painful gluteal abscess. The pain was so severe that the patient barely tolerated light palpation to the abscess area. Using dynamic ultrasound guidance, a TGSN block was performed with significant pain reduction. Ultrasonographic confirmation of abscess was obtained followed by definitive I&D. She was discharged from the ED and her incision site was healing well at the time of follow-up. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Abscess I&D is a common procedure in the ED. Procedural analgesia for I&D can be difficult to obtain. We describe the TGSN block as an additional analgesic option to be used for procedural analgesia. The use of regional anesthesia has the potential to decrease unwanted and at times dangerous side effects of opiate use and resource utilization of procedural sedation while optimizing patient comfort.


Assuntos
Analgesia , Anestesia por Condução , Bloqueio Nervoso , Adulto , Feminino , Humanos , Dor , Nervo Isquiático/diagnóstico por imagem , Ultrassonografia de Intervenção , Adulto Jovem
5.
J Emerg Med ; 61(5): 574-580, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34916056

RESUMO

BACKGROUND: Acute pain is one of the most common complaints encountered in the emergency department (ED). Single-injection peripheral nerve blocks are a safe and effective pain management tool when performed in the ED. Dexamethasone has been explored as an adjuvant to prolong duration of analgesia from peripheral nerve blocks in peri- and postoperative settings; however, data surrounding the use of dexamethasone for ED-performed nerve blocks are lacking. CASE SERIES: In this case series we discuss our experience with adjunctive perineural dexamethasone in ED-performed regional anesthesia. Why Should an Emergency Physician be Aware of This?: Nerve blocks performed with adjuvant perineural dexamethasone may be a safe additive to provide analgesia beyond the expected half-life of local anesthetic alone. Prospective studies exploring the role of adjuvant perineural dexamethasone in ED-performed nerve blocks are needed. © 2021 Elsevier Inc.


Assuntos
Anestesia por Condução , Dexametasona , Anestésicos Locais/uso terapêutico , Dexametasona/uso terapêutico , Serviço Hospitalar de Emergência , Humanos , Dor Pós-Operatória/tratamento farmacológico , Nervos Periféricos , Estudos Prospectivos
6.
Am J Emerg Med ; 38(10): 2245.e3-2245.e5, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32513452

RESUMO

The novel coronavirus SARS-CoV-2 (COVID-19) pandemic has created diagnostic uncertainty with regards to distinguishing this infection from pulmonary embolism (PE). Although there appears to be an increased incidence of thromboembolic disease in patients with COVID-19 infection, recommendations regarding anticoagulation are lacking. We present the case of a 61-year-old woman with clinically significant venous and arterial thromboemboli in the setting of COVID-19 infection requiring tissue plasminogen activator (tPA).


Assuntos
COVID-19/complicações , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Tromboembolia/diagnóstico , Dor Abdominal/etiologia , COVID-19/diagnóstico , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Pessoa de Meia-Idade , SARS-CoV-2 , Tromboembolia/etiologia
7.
Am J Emerg Med ; 38(7): 1542.e1-1542.e3, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32273141

RESUMO

The outbreak of a novel coronavirus disease (COVID-19) has been of concern to health care workers (HCW's) in the emergency department (ED) due to potential exposure and transmission. This case report describes a man who was referred to the ED for abdominal and testicular pain who was subsequently found to test positive for COVID-19. Due to the lack of respiratory symptoms, proper protective equipment (PPE) was not donned, and it led to several patients and health care workers being exposed. Given recent new descriptions of patients who present atypically, full PPE for all patients may be considered as community spread increases.


Assuntos
Dor Abdominal/etiologia , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/transmissão , Pessoal de Saúde , Pneumonia Viral/diagnóstico , Pneumonia Viral/transmissão , Doenças Testiculares/etiologia , Adulto , Betacoronavirus , COVID-19 , Infecção Hospitalar/virologia , Serviço Hospitalar de Emergência , Humanos , Controle de Infecções , Masculino , Pandemias , Equipamento de Proteção Individual , SARS-CoV-2
8.
Am J Emerg Med ; 38(9): 1792-1795, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32738473

RESUMO

Sciatic radicular back pain is a painful condition resulting in approximately 2% of emergency department (ED) visits a year. Typically, the ED treatment has been limited to various analgesic regimens with limited success sometimes resulting in hospital admissions for pain control. Regional anesthesia has become increasing popular for lower-limb analgesia, but has not universally permeated the ED setting. The transgluteal sciatic nerve block (TGSNB) is a procedure that can provide effective analgesia for lower extremity pain. Herein, we present the first technical description and clinical response to ultrasound-guided TGSNB performed by emergency physicians for acute pain control of sciatic back pain through a series of cases.


Assuntos
Analgesia/métodos , Dor nas Costas/tratamento farmacológico , Bloqueio Nervoso/métodos , Manejo da Dor/métodos , Radiculopatia/tratamento farmacológico , Nervo Isquiático , Ultrassonografia de Intervenção , Adulto , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor
9.
J Emerg Med ; 59(3): 409-412, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32534859

RESUMO

BACKGROUND: Herpes zoster (HZV) is a painful vesicular rash that occurs after reactivation in immunosuppressed patients. Analgesia in this patient population has been notoriously difficult. The serratus anterior and erector spinae plane block have both been described as effective thoracic analgesic techniques, but data are limited on their use in HZV. CASE REPORT: A middle-aged man with a history of hypertension and hyperlipidemia presented to the emergency department (ED) with chest and back pain associated with cutaneous rash. Traditional pain regimens were not effective; therefore, a serratus anterior plane block was performed using 25 mL of 0.25% of bupivacaine. The patient's pain decreased from 10 to 2 in 20 min and the patient was discharged without further analgesia. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: As opiate use decreases in prevalence and utility in the ED, alternatives to analgesia are sought. We describe the technique of regional anesthesia using a serratus anterior plane block as another modality that physicians can use to address HZV-related pain.


Assuntos
Herpes Zoster , Bloqueio Nervoso , Anestésicos Locais/uso terapêutico , Serviço Hospitalar de Emergência , Herpes Zoster/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia de Intervenção
10.
J Emerg Med ; 59(4): 515-520, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32713618

RESUMO

BACKGROUND: Lung point-of-care ultrasound (POCUS) is a critical tool for evaluating patients with dyspnea in the emergency department (ED), including patients with suspected coronavirus disease (COVID)-19. However, given the threat of nosocomial disease spread, the use of ultrasound is no longer risk free. OBJECTIVE: Here, we review the lung POCUS findings in patients with COVID-19. In doing so we present a scanning protocol for lung POCUS in COVID-19 that maximizes clinical utility and provider safety. DISCUSSION: In COVID-19 lung, POCUS findings are predominantly located in the posterior and lateral lung zones bilaterally. A six-zone scanning protocol that prioritizes obtaining images in these locations optimizes provider positioning, and minimizes time spent scanning, which can reduce risk to health care workers performing POCUS. CONCLUSIONS: Lung POCUS can offer valuable clinical data when evaluating patients with COVID-19. Scanning protocols such as that presented here, which target clinical utility and decreased nosocomial disease spread, must be prioritized.


Assuntos
COVID-19/diagnóstico por imagem , Protocolos Clínicos , Serviço Hospitalar de Emergência , Controle de Infecções/normas , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia/normas , Humanos , Posicionamento do Paciente , SARS-CoV-2 , Gestão da Segurança
12.
Acad Emerg Med ; 30(3): 172-179, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36354309

RESUMO

BACKGROUND: Point-of-care ultrasound (US) has been suggested as the primary imaging in evaluating patients with suspected diverticulitis. Discrimination between simple and complicated diverticulitis may help to expedite emergent surgical consults and determine the risk of complications. This study aimed to: (1) determine the accuracy of an US protocol (TICS) for diagnosing diverticulitis in the emergency department (ED) setting and (2) assess the ability of TICS to distinguish between simple and complicated diverticulitis. METHODS: Patients with clinically suspected diverticulitis who underwent a diagnostic computed tomography (CT) scan were identified prospectively in the ED. Emergency US faculty and fellows blinded to the CT results performed and interpreted US scans. The presence of simple or complicated diverticulitis was recorded after each US evaluation. The diagnostic ability of the US was compared to CT as the criterion standard. Modified Hinchey classification was used to distinguish between simple and complicated diverticulitis. RESULTS: A total of 149 patients (55% female, mean ± SD age 58 ± 16 years) were enrolled and included in the final analyses. Diverticulitis was the final diagnosis in 75 of 149 patients (50.3%), of whom 53 had simple diverticulitis and 22 had perforated diverticulitis (29.4%). TICS protocol's test characteristics for simple diverticulitis include a sensitivity of 95% (95% confidence interval [CI] 87%-99%), specificity of 76% (95% CI 65%-86%), positive predictive value of 80% (95% CI 71%-88%), and negative predictive value of 93% (95% CI 84%-98%). TICS protocol correctly identified 12 of 22 patients with complicated diverticulitis (sensitivity 55% [95% CI 32%-76%]) and specificity was 96% (95% CI 91%-99%). Eight of 10 missed diagnoses of complicated diverticulitis were identified as simple diverticulitis, and two were recorded as negative. CONCLUSIONS: In ED patients with suspected diverticulitis, US demonstrated high accuracy in ruling out or diagnosing diverticulitis, but its reliability in differentiating complicated from simple diverticulitis is unsatisfactory.


Assuntos
Diverticulite , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Diverticulite/complicações , Diverticulite/diagnóstico por imagem , Valor Preditivo dos Testes , Ultrassonografia , Sensibilidade e Especificidade
13.
AEM Educ Train ; 7(5): e10912, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37817836

RESUMO

Background: Managing acute pain is a common challenge in the emergency department (ED). Though widely used in perioperative settings, ED-based ultrasound-guided nerve blocks (UGNBs) have been slow to gain traction. Here, we develop a low-cost, low-fidelity, simulation-based training curriculum in UGNBs for emergency physicians to improve procedural competence and confidence. Methods: In this pre-/postintervention study, ED physicians were enrolled to participate in a 2-h, in-person simulation training session composed of a didactic session followed by rotation through stations using handmade pork-based UGNB models. Learner confidence with performing and supervising UGNBs as well as knowledge and procedural-based competence were assessed pre- and posttraining via electronic survey quizzes. One-way repeated-measures ANOVAs and pairwise comparisons were conducted. The numbers of nerve blocks performed clinically in the department pre- and postintervention were compared. Results: In total, 36 participants enrolled in training sessions, eight participants completed surveys at all three data collection time points. Of enrolled participants, 56% were trainees, 39% were faculty, 56% were female, and 53% self-identified as White. Knowledge and competency scores increased immediately postintervention (mean ± SD t0 score 66.9 ± 8.9 vs. t1 score 90.4 ± 11.7; p < 0.001), and decreased 3 months postintervention but remained elevated above baseline (t2 scores 77.2 ± 11.5, compared to t0; p = 0.03). Self-reported confidence in performing UGNBs increased posttraining (t0 5.0 ± 2.3 compared to t1 score 7.1 ± 1.5; p = 0.002) but decreased to baseline levels 3 months postintervention (t2 = 6.0 ± 1.9, compared to t0; p = 0.30). Conclusions: A low-cost, low-fidelity simulation curriculum can improve ED provider procedural-based competence and confidence in performing UGNBs in the short term, with a trend toward sustained improvement in knowledge and confidence. Curriculum adjustments to achieve sustained improvement in confidence performing and supervising UGNBs long term are key to increased ED-based UGNB use.

14.
Eur J Heart Fail ; 25(7): 1166-1169, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37218619

RESUMO

AIM: Acute decompensated heart failure (ADHF) is the leading cause of cardiovascular hospitalizations in the United States. Detecting B-lines through lung ultrasound (LUS) can enhance clinicians' prognostic and diagnostic capabilities. Artificial intelligence/machine learning (AI/ML)-based automated guidance systems may allow novice users to apply LUS to clinical care. We investigated whether an AI/ML automated LUS congestion score correlates with expert's interpretations of B-line quantification from an external patient dataset. METHODS AND RESULTS: This was a secondary analysis from the BLUSHED-AHF study which investigated the effect of LUS-guided therapy on patients with ADHF. In BLUSHED-AHF, LUS was performed and B-lines were quantified by ultrasound operators. Two experts then separately quantified the number of B-lines per ultrasound video clip recorded. Here, an AI/ML-based lung congestion score (LCS) was calculated for all LUS clips from BLUSHED-AHF. Spearman correlation was computed between LCS and counts from each of the original three raters. A total of 3858 LUS clips were analysed on 130 patients. The LCS demonstrated good agreement with the two experts' B-line quantification score (r = 0.894, 0.882). Both experts' B-line quantification scores had significantly better agreement with the LCS than they did with the ultrasound operator's score (p < 0.005, p < 0.001). CONCLUSION: Artificial intelligence/machine learning-based LCS correlated with expert-level B-line quantification. Future studies are needed to determine whether automated tools may assist novice users in LUS interpretation.


Assuntos
Insuficiência Cardíaca , Edema Pulmonar , Humanos , Inteligência Artificial , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/complicações , Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/etiologia , Ultrassonografia/métodos
15.
IEEE J Biomed Health Inform ; 27(9): 4352-4361, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37276107

RESUMO

Lung ultrasound (LUS) is an important imaging modality used by emergency physicians to assess pulmonary congestion at the patient bedside. B-line artifacts in LUS videos are key findings associated with pulmonary congestion. Not only can the interpretation of LUS be challenging for novice operators, but visual quantification of B-lines remains subject to observer variability. In this work, we investigate the strengths and weaknesses of multiple deep learning approaches for automated B-line detection and localization in LUS videos. We curate and publish, BEDLUS, a new ultrasound dataset comprising 1,419 videos from 113 patients with a total of 15,755 expert-annotated B-lines. Based on this dataset, we present a benchmark of established deep learning methods applied to the task of B-line detection. To pave the way for interpretable quantification of B-lines, we propose a novel "single-point" approach to B-line localization using only the point of origin. Our results show that (a) the area under the receiver operating characteristic curve ranges from 0.864 to 0.955 for the benchmarked detection methods, (b) within this range, the best performance is achieved by models that leverage multiple successive frames as input, and (c) the proposed single-point approach for B-line localization reaches an F 1-score of 0.65, performing on par with the inter-observer agreement. The dataset and developed methods can facilitate further biomedical research on automated interpretation of lung ultrasound with the potential to expand the clinical utility.


Assuntos
Aprendizado Profundo , Edema Pulmonar , Humanos , Pulmão/diagnóstico por imagem , Ultrassonografia/métodos , Edema Pulmonar/diagnóstico , Tórax
16.
Clin Pract Cases Emerg Med ; 6(4): 276-279, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36427038

RESUMO

INTRODUCTION: Pain scales are often used in peripheral nerve block studies but are problematic due to their subjective nature. Ultrasound-measured diaphragmatic excursion is an easily learned technique that could provide a much-needed objective measure of pain control over time with serial measurements. CASE SERIES: We describe three cases where diaphragmatic excursion was used as an objective measure of decreased pain and improved respiratory function after serratus anterior plane block in emergency department patients with anterior or lateral rib fractures. CONCLUSION: Diaphragmatic excursion may be an ideal alternative to pain scores to evaluate serratus anterior plane block efficacy. More data will be needed to determine whether this technique can be applied to other ultrasound-guided nerve blocks.

17.
Sci Rep ; 12(1): 20461, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-36443355

RESUMO

Patient-performed point-of-care ultrasound (POCUS) may be feasible for use in home-based healthcare. We investigated whether novice users can obtain lung ultrasound (LUS) images via self-scanning with similar interpretability and quality as experts. Adult participants with no prior medical or POCUS training, who were capable of viewing PowerPoint slides in their home and who could hold a probe to their chest were recruited. After training, volunteers self-performed 8-zone LUS and saved images using a hand-held POCUS device in their own home. Each 8-zone LUS scan was repeated by POCUS experts. Clips were independently viewed and scored by POCUS experts blinded to performing sonographers. Quality and interpretability scores of novice- and expert-obtained LUS images were compared. Thirty volunteers with average age of 42.8 years (Standard Deviation (SD) 15.8), and average body mass index of 23.7 (SD 3.1) were recruited. Quality of novice and expert scans did not differ (median score 2.6, interquartile range (IQR) 2.3-2.9 vs. 2.8, IQR 2.3-3.0, respectively p = 0.09). Individual zone quality also did not differ (P > 0.05). Interpretability of LUS was similar between expert and novice scanners (median 7 zones interpretable, IQR 6-8, for both groups, p = 0.42). Interpretability of novice-obtained scans did not differ from expert scans (median 7 out of 8 zones, IQR 6-8, p = 0.42). Novice-users can self-obtain interpretable, expert-quality LUS clips with minimal training. Patient-performed LUS may be feasible for outpatient home monitoring.


Assuntos
Diagnóstico por Imagem , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Humanos , Ultrassonografia , Testes Imediatos , Tórax
18.
Ultrasound Med Biol ; 48(8): 1509-1517, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35527112

RESUMO

Ultrasonographic B-lines are artifacts present in alveolar-interstitial syndromes. We prospectively investigated optimal depth, gain, focal position and transducer type for B-line visualization and image quality. B-Lines were assessed at a single rib interspace with curvilinear and linear transducers. Video clips were acquired by changing parameters: depth (6, 12, 18 and 24 cm for curvilinear transducer, 4 and 8 cm for linear transducer), gain (10%, 50% and 90%) and focal position (at the pleural line or half the scanning depth). Clips were scored for B-lines and image quality. Five hundred sixteen clips were obtained and analyzed. The curvilinear transducer improved B-line visualization (63% vs. 37%, p < 0.0001), with higher image quality (3.52 ± 0.71 vs. 3.31 ± 0.86, p = 0.0047) compared with the linear transducer. B-Lines were better visualized at higher gains (curvilinear: gain of 50% vs. 10%, odds ratio = 7.04, 95% confidence interval: 4.03-12.3; gain of 90% vs. 10%, odds ratio = 9.48, 95% confidence interval: 5.28-17.0) and with the focal point at the pleural line (odds ratio = 1.64, 95% confidence interval: 1.02-2.63). Image quality was highest at 50% gain (p = 0.02) but decreased at 90% gain (p < 0.0001) and with the focal point at the pleural line (p < 0.0001). Image quality was highest at depths of 12-18 cm. B-Lines are best visualized using a curvilinear transducer with at least 50% gain and focal position at the pleural line. Gain less than 90% and image depth between 12 and 18 cm improve image quality.


Assuntos
Pulmão , Transdutores , Pulmão/diagnóstico por imagem , Tórax , Ultrassonografia
19.
POCUS J ; 7(2): 253-261, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36896375

RESUMO

Acute pain is one of the most frequent, and yet one of the most challenging, complaints physicians encounter in the emergency department (ED). Currently, opioids are one of several pain medications given for acute pain, but given the long-term side effects and potential for abuse, alternative pain regimens are sought. Ultrasound-guided nerve blocks (UGNB) can provide quick and sufficient pain control and therefore can be considered a component of a physician's multimodal pain plan in the ED. As UGNB are more widely implemented at the point of care, guidelines are needed to assist emergency providers to acquire the skill necessary to incorporate them into their acute pain management.

20.
JMIR Form Res ; 6(3): e28353, 2022 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-35315781

RESUMO

BACKGROUND: Shift work is associated with sleep disorders, which impair alertness and increase risk of chronic physical and mental health disease. In health care workers, shift work and its associated sleep loss decrease provider wellness and can compromise patient care. Pharmacological sleep aids or substances such as alcohol are often used to improve sleep with variable effects on health and well-being. OBJECTIVE: We tested whether use of noise-masking earbuds can improve reported sleep quality, sleepiness, and stress level in health care shift workers, and increase alertness and reaction time post night shift. METHODS: Emergency medicine resident physicians were recruited for a prospective, single-subject design study. Entrance surveys on current sleep habits were completed. For 14 days, participants completed daily surveys reporting sleep aid use and self-rated perceived sleepiness, tension level, and last nights' sleep quality using an 8-point Likert scale. After overnight shifts, 3-minute psychomotor vigilance tests (PVT) measuring reaction time were completed. At the end of 14 days, participants were provided noise-masking earbuds, which they used in addition to their baseline sleep regimens as they were needed for sleep for the remainder of the study period. Daily sleep surveys, post-overnight shift PVT, and earbud use data were collected for an additional 14 days. A linear mixed effects regression model was used to assess changes in the pre- and postintervention outcomes with participants serving as their own controls. RESULTS: In total, 36 residents were recruited, of whom 26 participants who completed daily sleep surveys and used earbuds at least once during the study period were included in the final analysis. The median number of days of earbud use was 5 (IQR 2-9) days of the available 14 days. On days when residents reported earbud use, previous nights' sleep quality increased by 0.5 points (P<.001, 95% CI 0.23-0.80), daily sleepiness decreased by 0.6 points (P<.001, 95% CI -0.90 to -0.34), and total daily tension decreased by 0.6 points (P<.001, 95% CI -0.81 to -0.32). These effects were more pronounced in participants who reported worse-than-average preintervention sleep scores. CONCLUSIONS: Nonpharmacological noise-masking interventions such as earbuds may improve daily sleepiness, tension, and perceived sleep quality in health care shift workers. Larger-scale studies are needed to determine this interventions' effect on other populations of shift workers' post-night shift alertness, users' long-term physical and mental health, and patient outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA