Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Nanosci Nanotechnol ; 16(3): 3039-44, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27455756

RESUMO

ITO glass is a substrate often utilized to construct various IT devices and sensors, favored for its excellent characteristics such as rapid electron transfer kinetics, non-toxicity, chemical stability, and high electron transmission. In this paper, film with ZnO-modified nanostructures on ITO glass was fabricated by both electrochemical deposition and hydrothermal deposition, respectively. The ZnO film as-deposited was then modified by surface modification reagent (FOTMS) to obtain a hydrophobic surface. SEM, XRD, and ZYGO were used to characterize their properties. The contact angles were then measured to characterize and compare the wettability of non-modified ITO glass and ITO glass modified by zinc oxide films.


Assuntos
Técnicas Eletroquímicas/métodos , Vidro , Molhabilidade , Óxido de Zinco/química , Cristalografia por Raios X , Microscopia Eletrônica de Varredura , Análise Espectral Raman
2.
Micromachines (Basel) ; 14(8)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37630078

RESUMO

Aiming at the problems of low machining accuracy and more serious tool wear in the traditional diamond grinding machining (DGM) microstructure of hard and brittle materials, this paper proposes high-speed rotary ultrasonic machining (HRUM) technology and develops a HRUM machine tool. The hardware part of the machine tool mainly includes the spindle module, micro-motion system module, ultrasonic machining tank module, and data acquisition (DAQ) system module. The LabView-based controlled machining control system, including motion selection, initialization, coarse tool setting, constant force tool setting, control machining, and coordinate display module, is developed. Comparative experimental research of the HRUM and DGM of small holes in Al2O3 ceramics is carried out in the developed HRUM machine tool. The results demonstrate that HRUM effectively reduces axial cutting forces, reduces binder adhesion, and suppresses slippage while improving tool-cutting ability and extending tool life compared to DGM under the same machining parameters. This technology has essential research significance for the high-precision and efficient machining of microstructures in hard and brittle materials.

3.
Micromachines (Basel) ; 14(8)2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37630114

RESUMO

The extensive water pollution caused by production activities is a key issue that needs to be addressed in the aquaculture industry. The dynamic monitoring of water quality is essential for understanding water quality and the growth of fish fry. Here, a low-cost, low-noise, real-time monitoring and automatic feedback biomimetic robotic fish was proposed for the dynamic monitoring of multiple water quality parameters in aquaculture. The biomimetic robotic fish achieved a faster swimming speed and more stable posture control at a swing angular velocity of 16 rad/s by using simulation analysis. A fast swimming speed (0.4 m/s) was achieved through the control of double-jointed pectoral and caudal fins, exhibiting various types of movements, such as straight swimming, obstacle avoidance, turning, diving, and surfacing. As a demonstration of application, bionic robotic fish were placed in a lake for on-site water sampling and parameter detection. The relative average deviations in water quality parameters, such as water temperature, acidity and alkalinity, and turbidity, were 1.25%, 0.07%, and 0.94%, respectively, meeting the accuracy requirements for water quality parameter detection. In the future, bionic robotic fish are beneficial for monitoring water quality, fish populations, and behaviors, improving the efficiency and productivity of aquaculture, and also providing interesting tools and technologies for science education and ocean exploration.

4.
Micromachines (Basel) ; 11(2)2020 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-32098210

RESUMO

Integrated microfluidic systems afford extensive benefits for chemical and biological fields, yet traditional, monolithic methods of microfabrication restrict the design and assembly of truly complex systems. Here, a simple, reconfigurable and high fluid pressure modular microfluidic system is presented. The screw interconnects reversibly assemble each individual microfluidic module together. Screw connector provided leak-free fluidic communication, which could withstand fluid resistances up to 500 kPa between two interconnected microfluidic modules. A sample library of standardized components and connectors manufactured using 3D printing was developed. The capability for modular microfluidic system was demonstrated by generating sodium alginate gel microspheres. This 3D printed modular microfluidic system makes it possible to meet the needs of the end-user, and can be applied to bioassays, material synthesis, and other applications.

5.
Micromachines (Basel) ; 11(3)2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32155922

RESUMO

Water pollution seriously affects human health. Accurate and rapid detection and timely treatment of toxic substances in water are urgently needed. A stacked multilayer electrostatic printing technique was developed for making nanofiber-based microfluidic chips for water-quality testing. Nanofiber membrane matrix structures for microfluidic devices were fabricated by electrospinning. A hydrophobic barrier was then printed through electrostatic wax printing. This process was repeatedly performed to create three-dimensional nanofiber-based microfluidic analysis devices (3D-µNMADs). Flexible printing enabled one-step fabrication without the need for additional alignment or adhesive bonding. Practical applications of 3D-µNMADs include a colorimetric platform to quantitatively detect iron ion concentrations in water. There is also great potential for personalized point-of-care testing. Overall, the devices offer simple fabrication processes, flexible prototyping, potential for mass production, and multi-material integration.

6.
RSC Adv ; 10(44): 26188-26196, 2020 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-35519730

RESUMO

Bionic electronic skin with human sensory capabilities has attracted extensive research interest, which has been applied in the fields of medical health diagnosis, wearable electronics, human-computer interaction, and bionic prosthetics. Electronic skin tactile pressure sensing required high sensitivity, good resolution and fast response for sensing different pressure stimuli. In particular, there were still great challenges in the detection of wide pressure and the preparation of sensitive unit microstructures. Here, the direct-write printing of Weissenberg principle to fabricate GNPs/MWCNT filled conductive composite flexible pressure sensors on PDMS substrates was proposed. The effects of platform moving speed, microneedle rotation speed and the number of direct-write times on the line width of the pressure sensitive structure were investigated based on orthogonal experiments, and the optimal direct-write printing parameters were obtained. The performance of the S-shaped polyline pressure sensor was tested, in which the sensitivity could reached 0.164 kPa-1, and the response/recovery time was 100 ms and 100 ms respectively. The capture cases of objects of different quality and objects with flat/curved surfaces were successively demonstrated to exhibit its excellent sensitivity, stability and fast response performance. This work may paved the road for future integration of high-performance electronic skin in smart robotics and prosthetic solutions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA