Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 158
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Exp Eye Res ; 241: 109854, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38453037

RESUMO

Mucosal chemokines have antimicrobial properties and play an important role in mucosal immunity. However, little is known about their expression on the ocular surface. This study aimed to analyze the expression of the mucosal chemokines CCL28, CXCL14 and CXCL17 in corneal and conjunctival epithelial cells under in vitro dry eye (DE) conditions, and in conjunctival samples from healthy subjects and DE patients. Human corneal epithelial cells (HCE) and immortalized human conjunctival epithelial cells (IM-HConEpiC) were incubated under hyperosmolar (400-500 mOsM) or inflammatory (TNF-α 25 ng/mL) conditions for 6 h and 24 h to measure CCL28, CXCL14, and CXCL17 gene expression by RT-PCR and their secretion by immunobead-based analysis (CCL28, CXCL14) and ELISA (CXCL17). Additionally, twenty-seven DE patients and 13 healthy subjects were included in this study. DE-related questionnaires (OSDI, mSIDEQ and NRS) evaluated symptomatology. Ocular surface integrity was assessed using vital staining. Tactile sensitivity was measured with Cochet-Bonnet esthesiometer, and mechanic and thermal (heat and cold) sensitivity using Belmonte's non-contact esthesiometer. Subbasal nerve plexus and dendritic cell density were analyzed by in vivo confocal microscopy. Conjunctival cells from participants were collected by impression cytology to measure mucosal chemokines gene expression by RT-PCR. Our results showed that HCE and IM-HConEpiC cells increased CCL28, CXCL14, and CXCL17 secretion under hyperosmolar conditions. The gene expression of CCL28 was significantly upregulated in conjunctival samples from DE patients. CCL28 expression correlated positively with symptomatology, corneal staining, heat sensitivity threshold, and dendritic cell density. CXCL14 expression correlated positively with age, ocular pain, conjunctival staining, tactile sensitivity, and image reflectivity. CXCL17 expression correlated positively with corneal staining. These results suggest that corneal and conjunctival epithelial cells could be a source of CCL28, CXCL14, and CXCL17 on the ocular surface and that CCL28 might be involved in DE pathogenesis.


Assuntos
Dieldrin/análogos & derivados , Síndromes do Olho Seco , Humanos , Síndromes do Olho Seco/patologia , Quimiocinas/genética , Córnea/patologia , Túnica Conjuntiva/patologia , Quimiocinas CC , Quimiocinas CXC
2.
Eur J Clin Microbiol Infect Dis ; 43(5): 999-1002, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376633

RESUMO

This case report details the management of a 79-year-old male with recurrent methicillin-resistant Staphylococcus capitis bacteremia and endocarditis. The patient's clinical journey encompassed multiple hospital admissions, with challenges in managing endocarditis, pacemaker replacements, and potential cutaneous sources of infection. The treatment regimen included intravenous antibiotic therapy during hospitalization and suppressive antibiotic treatment upon discharge, alongside a decolonization strategy for his scalp lesions.


Assuntos
Antibacterianos , Bacteriemia , Endocardite Bacteriana , Staphylococcus capitis , Humanos , Masculino , Idoso , Bacteriemia/tratamento farmacológico , Bacteriemia/microbiologia , Antibacterianos/uso terapêutico , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/diagnóstico , Staphylococcus capitis/efeitos dos fármacos , Staphylococcus capitis/isolamento & purificação , Staphylococcus capitis/genética , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/diagnóstico , Recidiva
3.
Ophthalmic Physiol Opt ; 44(1): 124-130, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37974449

RESUMO

PURPOSE: To assess the reliability and agreement of non-invasive break-up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques. METHODS: In this prospective cross-sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire-8, underwent NIBUT assessment with the CL in situ. The CA-800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively. The within-subject repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between the devices was compared using the Bland-Altman method. RESULTS: A total of 141 CL wearers (51 male and 90 female) with a mean age of 33.6 (SD = 12.2) years were included. The repeatability and ICC values obtained with the CA-800 device when measuring NIBUT were 5.4 s and 58.6% across the whole sample, 4.2 s and 48.8% for the asymptomatic group and 7.1 s and 68.4% for the symptomatic group. When using the subjective method (EasyTear®), the respective repeatability and ICC values were 7.3 s and 32.7% for the whole sample, 6.5 s and 30.4% for the asymptomatic group and 8.6 s and 35.9% for the symptomatic group. The CA-800 device provided significantly (p < 0.001) shorter NIBUT values compared with EasyTear® for the whole sample (3.3 [2.9] vs. 8.1 [3.4] s), the asymptomatic (3.3 [3.0] vs. 7.7 [3.6] s) and the symptomatic (3.8 [2.9] vs. 8.6 [3.0] s) groups. CONCLUSION: Objective (CA-800) NIBUT assessment provides more reliable measurements than the conventional subjective technique using the EasyTear® device. However, CL practitioners should also be aware that the objective method indicates shorter NIBUT values. Symptomatic CL wearers may also need a higher number of NIBUT measurements to obtain reliable estimations.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Humanos , Masculino , Feminino , Adulto , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Transversais , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Lágrimas
4.
Eye Contact Lens ; 50(9): 410-415, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39024060

RESUMO

OBJECTIVES: To evaluate the reliability and agreement of tear meniscus height (TMH) measurements performed with a corneal analyzer and optical coherence tomography (OCT) technology in contact lens (CL) wearers and its correlation with contact lens discomfort symptoms. METHODS: Asymptomatic and symptomatic CL wearers classified through the Contact Lens Dry Eye Questionnaire-8 were evaluated with the Corneal Analyzer (Topcon CA-800) and OCT technology (Topcon 3D OCT-2000). The repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between devices was calculated using the Bland-Altman method. The relationship between TMH measurements and the Contact Lens Dry Eye Questionnaire-8 and Contact Lens Discomfort Index scores was assessed through the Spearman correlation coefficient. RESULTS: Seventy-nine asymptomatic and 42 symptomatic CL wearers aged 34.24±12.50 years were enrolled. The repeatability values obtained for the CA-800 were 0.07 mm in all cases, and the ICC was 0.93 for the whole sample. The CA-800 provided significantly ( P <0.01) higher TMH values than the OCT for the whole sample (0.22±0.08 vs. 0.17±0.06 mm). A weak indirect correlation (ρ=-0.22) between the OCT TMH measurement and Contact Lens Discomfort Index scores was found ( P ≤0.04). CONCLUSION: The CA-800 provides reliable TMH measurements during CL wear; however, they might not be interchangeable with OCT ones. Tear meniscus height measurements might be useful as a complementary sign to detect CL discomfort, but it cannot be used alone as a diagnostic tool.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Lágrimas , Tomografia de Coerência Óptica , Humanos , Lágrimas/química , Tomografia de Coerência Óptica/métodos , Adulto , Masculino , Feminino , Reprodutibilidade dos Testes , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Pessoa de Meia-Idade , Lentes de Contato Hidrofílicas/efeitos adversos , Adulto Jovem , Inquéritos e Questionários
5.
Int Nurs Rev ; 71(3): 432-439, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38661539

RESUMO

AIMS: To describe the development process of a device from the conception of the idea to the first contact with the commercial environment, and to demonstrate its practical application through an interdisciplinary collaboration between nursing and engineering for the design of a protective device for peripheral venous catheters. BACKGROUND: Nurses are key agents for identifying unresolved needs or problems related to nursing care. To address these needs, creative ideation processes are often triggered among nurses to seek technological answers to these challenges. RESULTS: The ten steps to develop a device are presented: (1) detecting an unsatisfied clinical need; (2) searching for preexisting marketed products; (3) searching for patents; (4) maintaining confidentiality throughout the process; (5) obtaining institutional support; (6) forming a multidisciplinary team; (7) developing the idea; (8) applying for a patent; (9) building the prototype; (10) marketing the device. This methodology was applied to design a protective device for peripheral venous catheters in hospitalized patients. CONCLUSIONS: Nurses can play a key role in the promotion of healthcare innovation in their field to improve procedures, thanks to their direct contact with patients, and by providing their insight on devices that can enhance patient care. The successful interdisciplinary collaboration between nurses and engineers can provide a response to relevant clinical problems such as the manipulation or removal of peripheral venous catheters. IMPLICATIONS FOR NURSING AND/OR HEALTH POLICY: A hospital policy is required to encourage the participation of nurses in innovative actions. Furthermore, it is important to support nurse leaders who can play a pivotal role in incorporating creativity into work environments and empowering other nurses to innovatively address clinical issues. NO PATIENT OR PUBLIC CONTRIBUTION: This article describes the process for developing a health device.


Assuntos
Desenho de Equipamento , Humanos , Invenções , Comunicação Interdisciplinar , Cateterismo Periférico/enfermagem
6.
Small ; 18(27): e2201861, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35676237

RESUMO

Health monitoring is experiencing a radical shift from clinic-based to point-of-care and wearable technologies, and a variety of nanomaterials and transducers have been employed for this purpose. 2D materials (2DMs) hold enormous potential for novel electronics, yet they struggle to meet the requirements of wearable technologies. Here, aiming to foster the development of 2DM-based wearable technologies, reduced graphene oxide (rGO)-based liquid-gated transistors (LGTs) for cation sensing in artificial sweat endowed with distinguished performance and great potential for scalable manufacturing is reported. Laser micromachining is employed to produce flexible transistor test patterns employing rGO as the electronic transducer. Analyte selectivity is achieved by functionalizing the transistor channel with ion-selective membranes (ISMs) via a simple casting method. Real-time monitoring of K+ and Na+ in artificial sweat is carried out employing a gate voltage pulsed stimulus to take advantage of the fast responsivity of rGO. The sensors show excellent selectivity toward the target analyte, low working voltages (<0.5 V), fast (5-15 s), linear response at a wide range of concentrations (10 µm to 100 mm), and sensitivities of 1 µA/decade. The reported strategy is an important step forward toward the development of wearable sensors based on 2DMs for future health monitoring technologies.


Assuntos
Grafite , Dispositivos Eletrônicos Vestíveis , Plásticos , Suor , Transistores Eletrônicos
7.
Exp Eye Res ; 219: 109057, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35358536

RESUMO

The purpose of this study was to analyze inflammation- and pain-related molecules in tears of patients suffering from chronic ocular pain associated with dry eye (DE) and/or a previous corneal refractive surgery (RS). Based on history, symptomatology, and clinical signs, the subjects (n = 180, 51.0 ± 14.7 years, 118 females, 62 males) in this cross-sectional study were assigned to one of five groups: DE and chronic ocular pain after RS (P/DE-RS, n = 52); asymptomatic subjects, i.e., without DE and chronic ocular pain, after RS (A-RS, n = 30); DE and chronic ocular pain without previous RS (P/DE-nonRS, n = 31); DE, no pain, and no previous RS (DE-nonRS, n = 35); and asymptomatic subjects with no previous RS (controls, n = 32). The tear concentrations of 20 cytokines and substance P (SP) were analyzed by immunobead-based assay and enzyme-linked immunosorbent assay, respectively. We found that tear levels of interleukin (IL)-10 and SP were increased in the RS groups. There were significant differences in IL-8/CXCL8 among the five groups. Nerve growth factor (NGF) tear levels were significantly higher in P/DE-RS than in DE-nonRS and controls. IL-9 had the highest percentage of detection in the P/DE-RS and P/DE-nonRS groups, while macrophage inflammatory protein (MIP)-1α, IL-2, and interferon (IFN)-γ were higher in the P/DE-RS, A-RS, and P/DE-nonRS groups. IL-17A was detected only in the A-RS group. Moderate correlations were observed in the A-RS, P/DE-nonRS, DE-nonRS and controls groups. A positive correlation was obtained between growth related oncogene concentration and tear break-up time (rho = 0.550; p = 0.012), while negative correlation was found between monocyte chemoattractant protein-3/CCL7 and conjunctival staining (rho = -0.560; p = 0.001), both in the A-RS group. IL-10 correlated positively with ocular pain intensity (rho = 0.513; p = 0.003) in the P/DE-nonRS group. Regulated on Activation Normal T Cell Expressed and Secreted/CCL5 correlated negatively with conjunctival staining (rho = -0.545; p = 0.001) in the DE-nonRS group. SP correlated negatively with corneal staining (rho = -0.559; p = 0.001) in the controls. In conclusion, chronic ocular pain was associated with higher IL-9 tear levels. IL-10, SP, MIP-1α/CCL3, IL-2, and IFN-γ were associated with previous RS. Higher levels of IL-8/CXCL8, MIP-1α/CCL3, IL-2, and IFN-γ were associated with DE-related inflammation, while NGF levels were related to chronic ocular pain and DE in RS patients. These findings suggest that improved knowledge of tear cytokines and neuromodulators will lead to a more nuanced understanding of how these molecules can serve as biomarkers of chronic ocular pain, leading to better therapeutic and disease management decisions.


Assuntos
Síndromes do Olho Seco , Doença Enxerto-Hospedeiro , Quimiocina CCL3/metabolismo , Túnica Conjuntiva/metabolismo , Estudos Transversais , Citocinas/metabolismo , Síndromes do Olho Seco/metabolismo , Feminino , Doença Enxerto-Hospedeiro/metabolismo , Humanos , Inflamação/metabolismo , Interleucina-10/metabolismo , Interleucina-2 , Interleucina-8/metabolismo , Interleucina-9/metabolismo , Masculino , Fator de Crescimento Neural , Dor/metabolismo , Lágrimas/metabolismo
8.
Molecules ; 27(23)2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36500334

RESUMO

Microtubule targeting agents (MTA) are anti-cancer molecules that bind tubulin and interfere with the microtubule functions, eventually leading to cell death. In the present study, we used an in vitro microtubule polymerization assay to screen several venom families for the presence of anti-microtubule activity. We isolated myotoxin-3, a peptide of the crotamine family, and three isoforms from the venom of the Northern Pacific rattlesnake Crotalus oreganus oreganus, which was able to increase tubulin polymerization. Myotoxin-3 turned out to be a cell-penetrating peptide that slightly diminished the viability of U87 glioblastoma and MCF7 breast carcinoma cells. Myotoxin 3 also induced remodeling of the U87 microtubule network and decreased MCF-7 microtubule dynamic instability. These effects are likely due to direct interaction with tubulin. Indeed, we showed that myotoxin-3 binds to tubulin heterodimer with a Kd of 5.3 µM and stoichiometry of two molecules of peptide per tubulin dimer. Our results demonstrate that exogenous peptides are good candidates for developing new MTA and highlight the richness of venoms as a source of pharmacologically active molecules.


Assuntos
Venenos de Crotalídeos , Neurotoxinas , Animais , Humanos , Neurotoxinas/metabolismo , Tubulina (Proteína)/metabolismo , Crotalus/metabolismo , Venenos de Crotalídeos/farmacologia , Venenos de Crotalídeos/metabolismo , Peptídeos/farmacologia , Peptídeos/metabolismo
9.
Eye Contact Lens ; 47(1): 8-14, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32097186

RESUMO

OBJECTIVES: Determining the changes in symptomatology suffered by dry eye disease (DED) patients after an intervention is difficult because there is only one validated questionnaire specifically designed to measure these changes and it is somewhat complex. This work uses a simplified questionnaire to evaluate the changes in DED-related symptoms. METHODS: A new questionnaire based on a global rating of change scale was designed. The Change in Dry Eye Symptoms Questionnaire (CDES-Q) consists of 2 questions: CDES-Q1 asks for the change in symptoms ("better," "same," or "worse") relative to a determined previous time and CDES-Q2 quantifies this change (range: 0 to +100). To evaluate the CDES-Q, a prospective observational study was performed. At baseline (V1; day-0), DED-related symptoms were evaluated using the ocular surface disease index (OSDI). In the post-treatment visit (V2; day-90), OSDI, Symptoms Assessment Questionnaire in Dry Eye (SANDE) II, and CDES-Q were used. Also, clinical evaluations were performed in each visit. RESULTS: Thirty-six patients were included. At V2, OSDI, SANDE II, and CDES-Q showed a significant reduction in symptoms (-7.17±12.73, P=0.0021; -11.29±20.95, P=0.0035; -25.28±42.28, P=0.0011, respectively). Patients who answered "better" in CDES-Q1 showed a significantly lower SANDE II than those who answered "same" or "worse," while SANDE II did not discriminate between these groups. CONCLUSIONS: CDES-Q can be a useful tool for the evaluation of changes in DED-related symptoms. It is simple and better discriminates patients without changes from those who suffered a worsening than SANDE II.


Assuntos
Síndromes do Olho Seco , Síndromes do Olho Seco/diagnóstico , Humanos , Estudos Prospectivos , Inquéritos e Questionários
10.
Eye Contact Lens ; 47(5): 256-264, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32649388

RESUMO

PURPOSE: To assess the consecutive implementation of habitual contact lens discomfort (CLD) management strategies: lid hygiene, daily disposable CL (DDCL) fitting, and artificial tear (AT) supplementation. METHODS: Contact lens (CL) wearers with CLD symptoms (CLDEQ-8 ≥12 points) were included in the study. Subjects with Meibomian gland dysfunction (MGD) were instructed to perform lid hygiene. All participants were fitted with a DDCL (delefilcon A) and evaluated 1 month later. After, half of them were randomly assigned to use AT (Povidone-2%) at least three times/day, and all participants were evaluated 1 month later. Tests performed were: lower tear meniscus area (LTMA), bulbar, limbal, and tarsal hyperemia, noninvasive tear break-up time (NITBUT), and corneal and conjunctival staining. Weighted combined clinical scores (CS) were created to analyze signs. Changes in symptoms (CLDEQ-8) and CS were analyzed using linear mixed models. RESULTS: Forty-two subjects (mean age: 23.2±4.9 years) completed the study. Two CS were created, CS 1 was composed of bulbar, limbal, and tarsal hyperemia and corneal staining, and CS 2 by NITBUT, LTMA, and conjunctival staining. CLDEQ-8 was reduced after lid hygiene (mean: -2.73±2.13; P=0.012) and DDCL use (mean: -10.1±3.54; P<0.01), but not after AT use (P=0.62). CS 1 did not change after any intervention. CS-2 was higher (P=0.04) in DGM subjects after lid hygiene, it decreased (P=0.04) after DDCL use. CONCLUSIONS: Lid hygiene is effective for reducing CLD symptoms in MGD patients. Refitting subjects with delefilcon A is an effective intervention for CLD to reduce symptoms and achieve a healthier ocular surface. Simultaneous administration of AT did not further improve CLD.


Assuntos
Lentes de Contato Hidrofílicas , Disfunção da Glândula Tarsal , Adulto , Túnica Conjuntiva , Córnea , Humanos , Lágrimas , Adulto Jovem
11.
Molecules ; 26(2)2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33445725

RESUMO

Nature has become one of the main sources of exploration for researchers that search for new potential molecules to be used in therapy. Polyphenols are emerging as a class of compounds that have attracted the attention of pharmaceutical and biomedical scientists. Thanks to their structural peculiarities, polyphenolic compounds are characterized as good scavengers of free radical species. This, among other medicinal effects, permits them to interfere with different molecular pathways that are involved in the inflammatory process. Unfortunately, many compounds of this class possess low solubility in aqueous solvents and low stability. Ocular pathologies are spread worldwide. It is estimated that every individual at least once in their lifetime experiences some kind of eye disorder. Oxidative stress or inflammatory processes are the basic etiological mechanisms of many ocular pathologies. A variety of polyphenolic compounds have been proved to be efficient in suppressing some of the indicators of these pathologies in in vitro and in vivo models. Further application of polyphenolic compounds in ocular therapy lacks an adequate formulation approach. Therefore, more emphasis should be put in advanced delivery strategies that will overcome the limits of the delivery site as well as the ones related to the polyphenols in use. This review analyzes different drug delivery strategies that are employed for the formulation of polyphenolic compounds when used to treat ocular pathologies related to oxidative stress and inflammation.


Assuntos
Sistemas de Liberação de Medicamentos , Olho/efeitos dos fármacos , Polifenóis/farmacologia , Animais , Humanos , Inflamação/patologia , Estresse Oxidativo/efeitos dos fármacos
12.
Exp Eye Res ; 193: 107976, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32081669

RESUMO

Neuropathic dry eye is one of the most frequently seen complications after corneal refractive surgery, however, its incidence decreases in a significant manner along the first six months postoperative, reaching between 10 and 45% incidence. However, little is known on the inflammatory status of the ocular surface during this recovery process. We aim to analyze the clinical and tear molecule concentration changes along six months after advanced surface ablation for myopia correction, in a prospective study including 18 eyes of 18 subjects who bilaterally underwent advanced surface ablation corneal refractive surgery. Clinical variables (uncorrected distance visual acuity, symptoms, conjunctival hyperemia, tear osmolarity, tear stability, corneal fluorescein staining, conjunctival lissamine staining, Schirmer test, and corneal esthesiometry) and a panel of 23 pro and anti-inflammatory cytokines/chemokines concentration in tears preoperatively and at 1, 3 and 6 months postoperatively were evaluated. We found that uncorrected distance visual acuity improved significantly from baseline at 1-month visit, symptoms improved and tear osmolarity decreased significantly from baseline at 3-month visit and there was a decrease in mechanical corneal threshold between 1-month and 3- and 6-month visits. Regarding tear molecules, IL-4, IL-5, IL-6, IL-13, IL-17A, and IFN-γ tear levels were significantly increased at all the three visits, compared to preoperative levels at V0; IL-2 and VEGF were also significantly increased at 1-month and 6-month visits, but not at 3-month visit, whereas IL-9 IL-10 and IL-12 were only significantly increased at 6-month visit. Although we found that there is a recovery in clinical variables at 6 months postoperatively (i.e. neuropathic dry eye was not developed in the sample), ocular surface homeostasis is not completely restored, as it can be seen by the changes in concentration of some pro and anti-inflammatory molecules measured in tears.


Assuntos
Citocinas/metabolismo , Síndromes do Olho Seco/metabolismo , Terapia a Laser/efeitos adversos , Procedimentos Cirúrgicos Refrativos/efeitos adversos , Lágrimas/metabolismo , Adulto , Biomarcadores/metabolismo , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Concentração Osmolar , Estudos Prospectivos , Fatores de Tempo , Acuidade Visual
13.
Phys Chem Chem Phys ; 22(33): 18261-18264, 2020 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-32785352

RESUMO

A detailed analysis of the ECL interaction between luminol and tris(2,2'-bipyridyl)dichlororuthenium(ii) (Ru(bpy)32+) is required before using them in ECL systems for multianalyte detection purposes. Spectro-electrochemiluminescence demonstrates that not only must the emission properties be considered, but also their additional optical characteristics are involved in the explanation of the interaction mechanism between these luminophores.

14.
Sensors (Basel) ; 20(13)2020 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-32630681

RESUMO

Metal phthalocyanines are well-known sensing phases with applications in different scientific fields due to their interesting properties. Detailed characterization by Raman spectroscopy was performed in order to study the shifting of the vibrational bands related to the coordination sphere of each metal phthalocyanine. In this work, a study involving the use of screen-printed electrodes (SPEs) with various metal phthalocyanines to electrochemically detect and quantify chlorine (Cl2) gas is presented. The Cl2 gas was generated in-situ via oxidation of the chloride present in form of aqueous salt solutions. The developed method offers not only the possibility to quantify chlorine, but also to discriminate among several chlorinated species due to the changes observed in the voltammetric profiles associated with the interaction between the specie assayed and the phthalocyanine metallic center. Optimization of detecting parameters was also performed to apply this procedure for the quantification of chlorine generated from commercial chlorine tablets. The development of this proof of concept shows interesting possibilities and easy-to-use applications with novel on metal phthalocyanines based SPE sensors.

15.
Phys Chem Chem Phys ; 21(12): 6314-6318, 2019 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-30849168

RESUMO

NIR spectroelectrochemistry has scarcely been used for deconvolving aqueous mixtures due to the water restriction in this spectral range. However, this work offers an interesting approach for the study of mixtures of molecules with similar electrochemical and spectroscopic behaviour by overcoming the limitations of this hybrid technique. As a proof of concept, the resolution of mixtures of two dyes with similar chemical structures demonstrates the usefulness of NIR spectroelectrochemistry.

16.
Ophthalmic Physiol Opt ; 39(5): 328-336, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31463969

RESUMO

PURPOSE: To investigate the effect of soft contact lens (CL) wear on the morphology of the epithelial-lamina propria junction as well as the possible association with symptoms of discomfort. METHODS: Ninety-two subjects were recruited, including 60 soft CL wearers, 16 previous wearers, and 16 non-wearers. Additionally, subjects were classified as symptomatic or asymptomatic using the Contact Lens Dry Eye Questionnaire 8 for the CL wearers (a score ≥ 12 was considered symptomatic) and the Dry Eye Questionnaire 5 for the previous wearers and non-wearers (a score ≥ 5 was considered symptomatic). In vivo confocal microscopy of the tarsal conjunctiva was performed on a single occasion. Papillae density, shortest diameter, longest diameter, area, circularity, lumen/wall brightness ratio, irregularity, reflectivity, inhomogeneous appearance of wall and inhomogeneous appearance of rete ridges were evaluated. Effects of CL wear, symptoms and their interaction were analysed using two-way analysis of variance. Correlations were investigated using Spearman's coefficient. Data are presented as mean (standard deviation) or median [interquartile range]. RESULTS: Contact lens wearers, compared to previous wearers and non-wearers, showed higher circularity [0.65 (0.08) vs 0.59 (0.10) vs 0.57 (0.11), p = 0.003]. Subjects with symptoms, compared to asymptomatic participants, showed higher circularity [0.64 (0.08) vs 0.61 (0.10), p < 0.001] and lower irregularity (1.0 [0.7-2.0] vs 1.3 [1.0-2.3], p = 0.009). For previous wearers, those with symptoms showed greater density (135.4 [107.3-183.3] vs 87.5 [85.4-116.7], p = 0.013) and circularity [0.64 (0.07) vs 0.54 (0.10), p = 0.016]. For non-wearers, those with symptoms showed higher circularity [0.65 (0.08) vs 0.50 (0.08), p < 0.001]. DEQ-5 correlated with circularity (ρ = 0.55, p = 0.001). CONCLUSIONS: Soft CL wear modifies papillae of the epithelial-lamina propria junction into a more rounded shape; however, CL cessation appears to resolve this alteration. Additionally, a more rounded papillae shape is associated with ocular symptoms in subjects not actively wearing CLs.


Assuntos
Túnica Conjuntiva/patologia , Lentes de Contato Hidrofílicas/efeitos adversos , Síndromes do Olho Seco/diagnóstico , Adulto , Análise de Variância , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Microscopia Confocal , Adulto Jovem
17.
Anal Chem ; 90(12): 7442-7449, 2018 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-29775045

RESUMO

Spectroelectrochemical techniques are becoming increasingly versatile tools to solve a diverse range of analytical problems. Herein, the use of in situ real-time luminescence spectroelectrochemistry to quantify chloride ions is demonstrated. Utilizing the bleaching effect of chlorine-based electrogenerated products after chloride oxidation, it is shown that the fluorescence of the rhodamine 6G dye decreases proportionally to the initial chloride concentration in solution. A strong decrease of fluorescence is observed in acidic media compared to a lower decrease in alkaline media, which suggests that Cl2, favorably generated at low pH, could be the main species responsible for the fluorescence loss. This fact is corroborated with chronoamperometric measurements where the complete loss of fluorescence for the bulk solution is achieved. A fast mass transfer is needed to explain this behavior, in agreement with the generation of gaseous species such as Cl2. Chloride detection was performed in artificial sweat samples in less than 30 s with great accuracy. This electrochemical/optical combined approach allows us to quantify species that are difficult to measure by electrochemistry due to the inadequate resolution of their redox processes or being without significant optical properties.

18.
Luminescence ; 33(3): 552-558, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29356382

RESUMO

In this work, a turn-off photoluminescent sensing proof-of-concept based on blue luminescent graphene quantum dots (GQDs) as the fluorescent probe was developed. For that purpose, GQDs optical response was related with the catalytic enzymatic activity of alkaline phosphatase (ALP), in the presence of hydroquinone diphosphate (HQDP). The hydrolysis of HQDP by ALP generated hydroquinone (HQ). The oxidation of HQ, enzymatically produced, to p-benzoquinone (BQ) resulted in the quenching of GQDs fluorescence (FL). Therefore, the developed luminescent sensing mechanism allowed the FL quenching with ALP activity to be related and thus quantified the concentration of ALP down to 0.5 nM of enzyme. This innovative design principle appears as a promising tool for the development of enzymatic sensors based on ALP labeling with fluorescent detection or even for direct ALP luminescent quantification in an easy, fast and sensitive manner.


Assuntos
Fosfatase Alcalina/análise , Hidroquinonas/química , Medições Luminescentes/métodos , Organofosfatos/química , Pontos Quânticos/química , Fosfatase Alcalina/química , Fosfatase Alcalina/metabolismo , Fluorescência , Corantes Fluorescentes/química , Grafite , Hidrólise , Limite de Detecção , Reprodutibilidade dos Testes
19.
Eye Contact Lens ; 44 Suppl 2: S227-S232, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29461299

RESUMO

OBJECTIVES: To determine the reliability of wet and modified dry blotting techniques used in the gravimetric method to assess contact lens (CL) water content (WC), the accuracy of both techniques in comparison with the nominal WC, and also their agreement. METHODS: We evaluated hydrated and dry CL mass values and WC using the gravimetric method in 440 daily disposable CLs. Samples assessed corresponded to Dailies Total 1, Dailies AquaComfort Plus, 1-Day Acuvue TruEye, and Biotrue ONEday. Back vertex power ranged from +3.00 diopters (D) to -6.00 D. Within-subject coefficient of variation (CVw) and intraclass correlation coefficients were calculated. Bland-Altman analysis was also performed. RESULTS: The modified dry blotting technique yielded significantly (P≤0.0001) higher hydrated CL mass values. The wet blotting technique provided significantly (P≤0.04) better consistency than the modified dry one. Values of CVw for wet and modified dry blotting techniques ranged from 1.2% to 2.1% and from 3.7% to 5.4%, respectively. As for dry CL mass values, CVw values were not significantly different (P≥0.05) between wet (range: 1.1%-1.9%) and dry (range: 1.0%-5.1%) blotting techniques, except for Dailies AquaComfort Plus (P=0.03). Bland-Altman analysis showed poor agreement between the techniques. The wet blotting technique yielded WC values close (around 1%) to nominal ones, in contrast to modified dry blotting technique (≥2.5%). CONCLUSIONS: The wet blotting technique is not only more reliable than the modified dry one when obtaining hydrated CL mass but also provides more accurate nominal WC measurements. Agreement between the techniques was poor.


Assuntos
Lentes de Contato Hidrofílicas , Teste de Materiais/métodos , Água/análise , Equipamentos Descartáveis , Humanos , Reprodutibilidade dos Testes
20.
Ophthalmic Physiol Opt ; 37(1): 60-70, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28030882

RESUMO

PURPOSE: To assess the influence of different indoor environments simulated in an environmental chamber on soft contact lens (CL) wearers. METHODS: Fifty-four CL wearers were grouped based on their symptoms while wearing their CLs. Subjects were fitted with two different CL types, conventional hydrogel (Omafilcon A) and silicone hydrogel (comfilcon A), and exposed to two controlled indoor environmental conditions, standard [50% relative humidity (RH), 23°C, 930 mb of atmospheric pressure] and adverse (in-flight air cabin environment: 5% RH, localised air flow, 23°C, 750 mb atmospheric pressure), for 90 min in an environmental chamber, making a total of four visits. Symptoms, tear osmolarity, pre-lens tear breakup time (PLBUT), phenol red thread test, visual acuity, bulbar and limbal hyperaemia, corneal and limbal staining, and CL dehydration were assessed using repeated measures analysis of variance. A linear mixed model was used to analyse the effect of environment, CL type, discomfort-based grouping, and time on blink rate. RESULTS: Environment was found to significantly (p ≤ 0.018) affect limbal and bulbar hyperaemia, PLBUT, tear osmolarity, and CL dehydration. Likewise, CL type significantly (p ≤ 0.04) affected nasal and total corneal staining, limbal conjunctival staining, CL dehydration, comfort, and blurred vision. The environment, CL type, and time had significant effects (p ≤ 0.0001) on the blink rate. CONCLUSIONS: Ocular surface integrity and blink rate in CL wearers depend on the environment CL users are exposed to, as well as on the soft CL type that they are wearing. Tight control of environmental conditions can contribute to a better understanding of CL-related discomfort.


Assuntos
Piscadela/fisiologia , Túnica Conjuntiva/diagnóstico por imagem , Lentes de Contato Hidrofílicas , Córnea/diagnóstico por imagem , Exposição Ambiental , Satisfação do Paciente , Acuidade Visual , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Inquéritos e Questionários , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA