Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Rev Esp Cir Ortop Traumatol ; 67(3): T216-T225, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36863523

RESUMO

INTRODUCTION AND OBJECTIVES: Distal femoral fractures represent a problem due to their high number of complications. The aim was to compare the results, complications and stability achieved with retrograde intramedullary nailing and the angular stable plate in the treatment of distal femoral diaphyseal fractures. MATERIAL AND METHOD: A clinical and experimental biomechanical study was carried out using finite elements. The results of the simulations allowed us to obtain the main results related to the stability of osteosynthesis. For clinical follow-up data, frequencies were used for qualitative variables, and Fisher's exact test and χ2 test were used to evaluate the significance of the different factors, with the condition of P<.05. RESULTS: In the biomechanical study, the retrograde intramedullar nails demonstrated superiority, obtaining lower values in terms of global displacement, maximum tension, torsion resistance, and bending resistance. In the clinical study, the rate of consolidation of the plates was lower than nails (77% vs. 96%, P=.02). The factor that most influenced the healing of fractures treated with plate were the central cortical thickness (P=.019). The factor that most influenced the healing of nail-treated fractures was the difference between the diameter of the medullary canal and the nail. CONCLUSIONS: Our biomechanical study shows that both osteosynthesis provide sufficient stability, but biomechanically behaves differently. Nails provide greater overall stability being preferable the use of long nails adjusted to the diameter of the canal. Plates form less rigid osteosynthesis, with little resistance to bending.

2.
Rev Esp Cir Ortop Traumatol ; 67(3): 216-225, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36649756

RESUMO

INTRODUCTION AND OBJECTIVES: Distal femoral fractures represent a problem due to their high number of complications. The aim was to compare the results, complications and stability achieved with retrograde intramedullary nailing and the angular stable plate in the treatment of distal femoral diaphyseal fractures. MATERIAL AND METHOD: A clinical and experimental biomechanical study was carried out using finite elements. The results of the simulations allowed us to obtain the main results related to the stability of osteosynthesis. For clinical follow-up data, frequencies were used for qualitative variables, and Fisher's exact test and χ2 test were used to evaluate the significance of the different factors, with the condition of P<.05. RESULTS: In the biomechanical study, the retrograde intramedullar nails demonstrated superiority, obtaining lower values in terms of global displacement, maximum tension, torsion resistance, and bending resistance. In the clinical study, the rate of consolidation of the plates was lower than nails (77% vs. 96%, P=.02). The factor that most influenced the healing of fractures treated with plate were the central cortical thickness (P=.019). The factor that most influenced the healing of nail-treated fractures was the difference between the diameter of the medullary canal and the nail. CONCLUSIONS: Our biomechanical study shows that both osteosynthesis provide sufficient stability, but biomechanically behaves differently. Nails provide greater overall stability being preferable the use of long nails adjusted to the diameter of the canal. Plates form less rigid osteosynthesis, with little resistance to bending.

3.
Injury ; 54(2): 395-404, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36528423

RESUMO

Distal femoral fractures are fractures associated with high rates of morbidity and mortality, affecting to three different groups of individuals: younger people suffering high-energy trauma, elderly people with fragile bones and people with periprosthetic fractures around previous total knee arthroplasty. They have been classically treated with conventional plates and intramedullary nails and more recently with locked plates that have increased their indications to more types of fractures. The main objective of the present work is the biomechanical study, by means of finite element simulation, of the stability achieved in the osteosynthesis of femoral fractures in zones 4 and 5 of Wiss, by using locked plates with different plate lengths and different screw configurations, and analysing the effect of screw proximity to the fracture site. A three dimensional (3D) finite element model of the femur from 55-year-old male donor was developed, and then a stability analysis was performed for the fixation provided by Osteosynthesis System LOQTEC® Lateral Distal Femur Plate in two different fracture zones corresponding to the zones 4 and 5 according to the Wiss fracture classification. The study was focused on the immediately post-operative stage, without any biological healing process. The obtained results show that more stable osteosyntheses were obtained by using shorter plates. In the cases of longer plates, it results more convenient disposing screws in a way that the upper ones are closer to fracture site. The obtained results can support surgeons to understand the biomechanics of fracture stability, and then to guide them towards the more appropriate osteosynthesis depending on the fracture type and location.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Consolidação da Fratura
4.
Injury ; 52 Suppl 4: S76-S86, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33642084

RESUMO

Fractures of the distal femur affect three different groups of individuals: younger people suffering high-energy trauma, elderly people with fragile bones and people with periprosthetic fractures around previous total knee arthroplasty. Main indications of intramedullary nailing are for supracondylar fractures type A or type C of the AO classification. The main objective of the present work is to analyze, by means of FE simulation, the influence of retrograde nail length, considering different blocking configurations and fracture gaps, on the biomechanical behavior of supracondylar fractures of A type. A three dimensional (3D) finite element model of the femur from 55-year-old male donor was developed, and then a stability analysis was performed for the fixation provided by the retrograde nail at a distal fracture with different fracture gaps: 0.5 mm, 3 mm y 20 mm, respectively. Besides, for each gap, three nail lengths were studied with a general extent (320 mm, 280 mm and 240 mm), considering two transversal screws (M/L) at the distal part and different screw combinations above the fracture. The study was focused on the immediately post-operative stage, without any biological healing process. In view of the obtained results, it has been demonstrated new possibilities of blocking configuration in addition to the usual ones, which allows establishing recommendations for nail design and clinical practice, avoiding excessive stress concentrations both in screws, with the problem of rupture and loss of blocking, and in the contact of nail tip with cortical bone, with the problem of a new stress fracture.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas Periprotéticas , Idoso , Fenômenos Biomecânicos , Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/cirurgia
5.
Biomed Mater Eng ; 15(5): 357-65, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16179756

RESUMO

We have designed, manufactured and evaluated a prototype of a new stent based on the superelasticity of the NiTi alloy for colon obstruction, which is the first clinical manifestation of colorectal cancer in up to 29% of cases. The stent is auto-expandable diamond cell type, manufactured from a NiTi tube with 4.5 mm in diameter, in which longitudinal grooves were performed by cutting laser technique. The expansion process to the final shape was made by deformation in the martensite state. The stent reaches a high free expansion rate of 7, with a longitudinal variable radial strength and a bell-shaped profile in the extremes in order to avoid migration. Finite elements models were used for simulating the mechanical behaviour. The prototype was evaluated by implantation in a colon stenosis model of 6 mm in diameter performed in a porcine speciment. The stent gave a good deployment, fixation and capability to open the gap up to 15 mm in diameter.


Assuntos
Materiais Biocompatíveis/química , Doenças do Colo/cirurgia , Obstrução Intestinal/cirurgia , Níquel/química , Stents , Titânio/química , Animais , Materiais Biocompatíveis/análise , Desenho Assistido por Computador , Análise de Falha de Equipamento , Teste de Materiais , Modelos Teóricos , Níquel/análise , Desenho de Prótese , Suínos , Titânio/análise , Resultado do Tratamento
6.
Biomaterials ; 25(1): 9-21, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14580904

RESUMO

We studied the fracture surface evolution of ultra high molecular weight polyethylene (UHMWPE) specimens, manufactured from GUR 1050 compression moulded sheets, after gamma sterilisation in air followed by different aging times after thermal treatment at 120 degrees C. Degradation profiles were obtained by FTIR and DSC measurements after 0, 7, 14, 24 and 36h aging. We observed by SEM the morphology patterns at these aging times, in surface fractographies after uniaxial tensile test of standardised samples. The results pointed out clear differences between short and long aging times. At shorter times, 7h, the behaviour was similar to non-degraded UHMWPE, exhibiting ductile behaviour. At longer times, 24-36h, this thermal protocol provided a highly degraded zone in the subsurface, similar to the white band found after gamma irradiation in air followed by natural aging, although closer to the surface, at 150-200mum. The microstructure of this oxidation zone, similarly found in gamma irradiated samples shelf-aged for 6-7 years, although with different distribution of microvoids, was formed by fibrils, associated with embrittlement of the oxidised UHMWPE. In addition, the evolution of the oxidation index, the enthalpy content, the mechanical parameters, and the depth of the oxidation front deduced from the fractographies versus aging time showed that a changing behaviour in the degradation rate appeared at intermediate aging times.


Assuntos
Ar , Materiais Biocompatíveis/química , Materiais Biocompatíveis/efeitos da radiação , Raios gama , Temperatura Alta , Polietilenos/química , Polietilenos/efeitos da radiação , Esterilização , Relação Dose-Resposta à Radiação , Elasticidade , Teste de Materiais/métodos , Conformação Molecular , Polietilenos/análise , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
7.
J Mech Behav Biomed Mater ; 15: 190-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23037304

RESUMO

Ultrahigh molecular weight polyethylenes (UHMWPE) showing wear resistance, oxidative stability and good mechanical performance go on being a relevant research area in biomaterials for total joint replacements, where fatigue happens to be a recurrent damage mode that needs to be investigated. While crack propagation lifetime has been extensively studied, fatigue initiation data are scarcely offered in the literature, often due to the higher costs implied in the experimental programs. Moreover, their analysis is not always suitable to obtain reliable guidance. Different deterministic and probabilistic methods, generally resting on empirical bases have been previously used to analyze the fatigue initiation data. In this work, the probabilistic Weibull regression model of Castillo et al., based on both physical and statistical conditions, such as weakest link principle and the necessary compatibility between life-time and stress range distributions, is applied for the first time in the assessment of fatigue results of polymers, particularly to highly crosslinked UHMWPEs (HXLPEs). Accordingly, different published experimental data corresponding to HXLPE stabilized by thermal treatments and with α-tocopherol (vitamin E) are re-analyzed. Additional data are incorporated to assess the influence of notched HXLPE on fatigue performance. New conclusions are drawn from this revision.


Assuntos
Modelos Estatísticos , Polietilenos/química , Falha de Prótese , Antioxidantes/química , Análise dos Mínimos Quadrados , Teste de Materiais , Falha de Prótese/efeitos da radiação , Estresse Mecânico , Temperatura , Fatores de Tempo , Tocoferóis/química
8.
Artigo em Inglês | MEDLINE | ID: mdl-17474056

RESUMO

The goal of this work is the mechanical comparison of different types of stents for colorectal obstructions. We consider self-expanding and balloon-expanding stents made of two different materials such as stainless steel and shape memory NiTi alloy. The mechanical parameters are expansion rate, shortening, radial compression resistance, longitudinal and perimetral adaptability, and buckling resistance. This analysis results in a better understanding of global mechanical behavior and also allows better design and device selection for colonic lesions.


Assuntos
Colo/cirurgia , Obstrução Intestinal/cirurgia , Níquel , Aço Inoxidável , Stents , Titânio , Engenharia Biomédica , Humanos , Teste de Materiais , Desenho de Prótese , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA