Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Circulation ; 107(14): 1840-3, 2003 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-12682003

RESUMO

BACKGROUND: In patients with acute myocardial infarction or unstable angina undergoing coronary angioplasty, abciximab reduces major adverse cardiac events (MACE). Clinical trials have studied intravenous administration only. Intracoronary bolus application of abciximab causes very high local drug concentrations and may be more effective. We studied whether intracoronary bolus administration of abciximab is associated with a reduced MACE rate compared with the standard intravenous bolus application. METHODS AND RESULTS: We stratified 403 consecutive patients with acute myocardial infarction or unstable angina undergoing coronary angioplasty according to the type of application of abciximab. A 20-mg bolus of abciximab was given intravenously in 109 patients and intracoronarily in 294 patients. There were no differences between the groups with regard to diabetes mellitus, cardiogenic shock, successful intervention, or preprocedural and postprocedural TIMI flow. At 30 days, the incidence of MACE (death, myocardial infarction, urgent revascularization) was significantly lower in the patients with intracoronary compared with intravenous administration of abciximab (10.2% versus 20.2%; P<0.008), which was independent from stenting in multivariate analysis. The effect was most pronounced in patients with preprocedural TIMI 0/1 flow (MACE: intracoronary 11.8% versus intravenous 27.5%, P<0.002; n=273). CONCLUSIONS: In patients with acute myocardial infarction or unstable angina undergoing emergency coronary angioplasty, intracoronary bolus application of abciximab is associated with a reduction of MACE compared with the standard intravenous bolus application of abciximab. Prospective, randomized trials are warranted to further assess intracoronary application of abciximab.


Assuntos
Angina Instável/terapia , Angioplastia Coronária com Balão/efeitos adversos , Anticorpos Monoclonais/administração & dosagem , Fragmentos Fab das Imunoglobulinas/administração & dosagem , Infarto do Miocárdio/terapia , Abciximab , Angina Instável/tratamento farmacológico , Angina Instável/mortalidade , Anticorpos Monoclonais/uso terapêutico , Terapia Combinada , Angiografia Coronária , Doença das Coronárias/epidemiologia , Doença das Coronárias/etiologia , Doença das Coronárias/prevenção & controle , Feminino , Coração , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Incidência , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/mortalidade , Estudos Retrospectivos , Prevenção Secundária
2.
Circulation ; 107(24): 3022-7, 2003 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-12796137

RESUMO

BACKGROUND: Restenosis requiring reintervention is the main limitation of coronary angioplasty. Intracoronary irradiation reduces neointimal proliferation. We studied the efficacy of a self-centering liquid rhenium-188-filled balloon catheter for coronary beta-brachytherapy. METHODS AND RESULTS: After successful coronary angioplasty with or without stenting, 225 patients (71% de novo lesions) were randomly assigned to receive 22.5 Gy intravascular beta-irradiation in 0.5-mm tissue depth (n=113) or to receive no additional intervention (n=112). Clinical and procedural data did not differ between the groups except a higher rate of stenting in the control group (63%) compared with the rhenium-188 group (45%, P<0.02). After 6 months of follow-up, late loss was significantly lower in the irradiated group compared with the control group, both of the target lesion (0.11+/-0.54 versus 0.69+/-0.81 mm, P<0.0001) and of the total segment (0.22+/-0.67 versus 0.70+/-0.82 mm, P<0.0001). This was also evident in the subgroup of patients with de novo lesions and independent from stenting. Binary restenosis rates were significantly lower at the target lesion (6.3% versus 27.5%, P<0.0001) and of the total segment (12.6% versus 28.6%, P<0.007) after rhenium-188 brachytherapy compared with the control group. Target vessel revascularization rate was significantly lower in the rhenium-188 (6.3%) compared with the control group (19.8%, P=0.006). CONCLUSIONS: Intracoronary beta-brachytherapy with a rhenium-188 liquid-filled balloon is safe and efficiently reduces restenosis and revascularization rates after coronary angioplasty.


Assuntos
Partículas beta/uso terapêutico , Braquiterapia/métodos , Cateterismo , Doença da Artéria Coronariana/radioterapia , Rênio , Angioplastia Coronária com Balão/instrumentação , Braquiterapia/efeitos adversos , Braquiterapia/instrumentação , Cateterismo/instrumentação , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Reestenose Coronária/radioterapia , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Radioisótopos , Resultado do Tratamento , Grau de Desobstrução Vascular
3.
J Cardiovasc Magn Reson ; 8(6): 781-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17060099

RESUMO

The present study examined the association of myocardial perfusion reserve index (MPRI) in cardiovascular magnetic resonance (CMR) with coronary microvascular dysfunction (CMD) and serum levels of markers of inflammation or endothelial activation. Twelve patients with typical angina pectoris without coronary artery disease were enrolled in this study, and CMR perfusion was analyzed using a steady-state-free-precession sequence with 3 short axis slices per heartbeat during first pass of 0.025 mmol Gadolinium-DTPA/kg body weight. The upslope of myocardial signal intensity curves was used to calculate MPRI. CMD was assessed by intracoronary Doppler flow measurement and biplane angiography. Both MPRI and CMD were assessed during endothelium-independent stimulation with intravenous adenosine and during endothelium-dependent stimulation with intracoronary infusion of acetylcholine. Serum values of soluble CD40 ligand (sCD40L), interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), soluble intercellular adhesion molecule-1 (sICAM-1), and C-reactive protein (CRP) were measured. Impaired MPRI correlated significantly with a decrease in coronary blood flow reserve after both endothelium-dependent (p = 0.033) and endothelium-independent (p = 0.022) stimulation. Serum levels above the median of all normal ranged biomarkers sCD40L, TNF-alpha, IL-6, sICAM-1 and CRP were associated with an impaired MPRI for stimulation with adenosine as well as acetylcholine. In multivariable analyses, sCD40L (p < 0.001) and TNF-alpha (p = 0.011) were significantly associated with a decrease in MPRI on adenosine, as were TNF-alpha (p = 0.016) and sICAM-1 (p = 0.022) for a decrease in MPRI on acetylcholine. MPRI on adenosine significantly correlated with MPRI on acetylcholine (p < 0.001). Therefore, the present study demonstrates safety and feasibility of an intracoronary infusion of acetylcholine during CMR perfusion analysis, thus allowing direct assessment of endothelial dependent vasomotor function at the myocardial level by CMR. Furthermore, we show that an impaired myocardial perfusion reserved in CMR is associated with established biomarkers of early atherosclerosis and significantly correlated with CMD. CMR combined with adenosine could be proposed as a non-invasive tool to evaluate CMD.


Assuntos
Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/patologia , Circulação Coronária , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Acetilcolina , Adenosina , Angina Pectoris/patologia , Velocidade do Fluxo Sanguíneo , Proteína C-Reativa/análise , Ligante de CD40/sangue , Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Ecocardiografia , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Molécula 1 de Adesão Intercelular/sangue , Interleucina-6/sangue , Masculino , Microcirculação , Pessoa de Meia-Idade , Análise Multivariada , Fator de Necrose Tumoral alfa/sangue , Vasodilatadores
4.
J Am Coll Cardiol ; 48(2): 322-9, 2006 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-16843183

RESUMO

OBJECTIVES: We studied the value of cardiac magnetic resonance imaging (CMRI) before and after closure of patent foramen ovale (PFO) in patients with cryptogenic ischemic events. BACKGROUND: Cardiac magnetic resonance imaging is a powerful noninvasive tool for detailed assessment of cardiac anatomy and function. The relevance of CMRI compared with transesophageal echocardiography (TEE) in patients undergoing transcatheter PFO closure has not been evaluated so far. METHODS: Contrast-enhanced CMRI and TEE were performed in 75 patients before and after PFO closure. Twelve months after PFO closure, both imaging techniques were repeated in 61 patients with contrast application. To determine provokable atrial right-to-left shunting in CMRI, we applied a contrast-enhanced perfusion imaging technique. Detection of atrial septal aneurysm (ASA) was achieved by means of a high-resolution cine imaging technique. RESULTS: Before PFO closure, ASA was seen with CMRI in 28 of 75 cases (37.3%), compared with 47 of 75 (62.7%) cases using TEE. There were a total of 211 CMRI studies with a corresponding TEE performed in 75 patients. No shunt was present in 107 of 211 studies with both techniques. Contrast-enhanced right-to-left shunting was detected by CMRI in 48 of 72 (66.6%) cases with moderate or severe shunts seen with TEE, but only in 6 of 32 (18.8%) studies with mild shunts with TEE. Anomalous venous returns were excluded in all patients. In two patients, coronary anomalies were seen. CONCLUSIONS: The present CMRI technique is inferior to TEE in detection of contrast-enhanced right-to-left shunting and identification of ASA.


Assuntos
Ecocardiografia Transesofagiana , Comunicação Interatrial/terapia , Imageamento por Ressonância Magnética , Adulto , Isquemia Encefálica/etiologia , Meios de Contraste , Circulação Coronária , Feminino , Gadolínio DTPA , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/complicações , Comunicação Interatrial/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Manobra de Valsalva , Função Ventricular Esquerda , Função Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA