RESUMO
PURPOSE: To propose a new reconstruction method for multidimensional MR fingerprinting (mdMRF) to address shading artifacts caused by physiological motion-induced measurement errors without navigating or gating. METHODS: The proposed method comprises two procedures: self-calibration and subspace reconstruction. The first procedure (self-calibration) applies temporally local matrix completion to reconstruct low-resolution images from a subset of under-sampled data extracted from the k-space center. The second procedure (subspace reconstruction) utilizes temporally global subspace reconstruction with pre-estimated temporal subspace from low-resolution images to reconstruct aliasing-free, high-resolution, and time-resolved images. After reconstruction, a customized outlier detection algorithm was employed to automatically detect and remove images corrupted by measurement errors. Feasibility, robustness, and scan efficiency were evaluated through in vivo human brain imaging experiments. RESULTS: The proposed method successfully reconstructed aliasing-free, high-resolution, and time-resolved images, where the measurement errors were accurately represented. The corrupted images were automatically and robustly detected and removed. Artifact-free T1, T2, and ADC maps were generated simultaneously. The proposed reconstruction method demonstrated robustness across different scanners, parameter settings, and subjects. A high scan efficiency of less than 20 s per slice has been achieved. CONCLUSION: The proposed reconstruction method can effectively alleviate shading artifacts caused by physiological motion-induced measurement errors. It enables simultaneous and artifact-free quantification of T1, T2, and ADC using mdMRF scans without prospective gating, with robustness and high scan efficiency.
Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Algoritmos , Imagens de Fantasmas , ArtefatosRESUMO
PURPOSE: Quantitative MRI techniques such as MR fingerprinting (MRF) promise more objective and comparable measurements of tissue properties at the point-of-care than weighted imaging. However, few direct cross-modal comparisons of MRF's repeatability and reproducibility versus weighted acquisitions have been performed. This work proposes a novel fully automated pipeline for quantitatively comparing cross-modal imaging performance in vivo via atlas-based sampling. METHODS: We acquire whole-brain 3D-MRF, turbo spin echo, and MPRAGE sequences three times each on two scanners across 10 subjects, for a total of 60 multimodal datasets. The proposed automated registration and analysis pipeline uses linear and nonlinear registration to align all qualitative and quantitative DICOM stacks to Montreal Neurological Institute (MNI) 152 space, then samples each dataset's native space through transformation inversion to compare performance within atlas regions across subjects, scanners, and repetitions. RESULTS: Voxel values within MRF-derived maps were found to be more repeatable (σT1 = 1.90, σT2 = 3.20) across sessions than vendor-reconstructed MPRAGE (σT1w = 6.04) or turbo spin echo (σT2w = 5.66) images. Additionally, MRF was found to be more reproducible across scanners (σT1 = 2.21, σT2 = 3.89) than either qualitative modality (σT1w = 7.84, σT2w = 7.76). Notably, differences between repeatability and reproducibility of in vivo MRF were insignificant, unlike the weighted images. CONCLUSION: MRF data from many sessions and scanners can potentially be treated as a single dataset for harmonized analysis or longitudinal comparisons without the additional regularization steps needed for qualitative modalities.
Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodosRESUMO
Quantitative magnetic resonance (MR) has been used to study cyto- and myelo-architecture of the human brain non-invasively. However, analyzing brain cortex using high-resolution quantitative MR acquisition can be challenging to perform using 3T clinical scanners. MR fingerprinting (MRF) is a highly efficient and clinically feasible quantitative MR technique that simultaneously provides T1 and T2 relaxation maps. Using 3D MRF from 40 healthy subjects (mean age = 25.6 ± 4.3 years) scanned on 3T magnetic resonance imaging, we generated whole-brain gyral-based normative MR relaxation atlases and investigated cortical-region-based T1 and T2 variations. Gender and age dependency of T1 and T2 variations were additionally analyzed. The coefficient of variation of T1 and T2 for each cortical-region was 3.5% and 7.3%, respectively, supporting low variability of MRF measurements across subjects. Significant differences in T1 and T2 were identified among 34 brain regions (P < 0.001), lower in the precentral, postcentral, paracentral lobule, transverse temporal, lateral occipital, and cingulate areas, which contain sensorimotor, auditory, visual, and limbic functions. Significant correlations were identified between age and T1 and T2 values. This study established whole-brain MRF T1 and T2 atlases of healthy subjects using a clinical 3T scanner, which can provide a quantitative and region-specific baseline for future brain studies and pathology detection.
Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Adulto Jovem , Adulto , Lactente , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Voluntários Saudáveis , Processamento de Imagem Assistida por Computador/métodosRESUMO
OBJECTIVE: This work presents an automated quality control (QC) system within quantitative MRI (qMRI) workflows. By leveraging the ISMRM/NIST quantitative MRI system phantom, we establish an open-source pipeline for rapid, repeatable, and accurate validation and stability tracking of sequence quantification performance across diverse clinical settings. MATERIALS AND METHODS: A microservice-based QC system for automated vial segmentation from quantitative maps was developed and tested across various MRF acquisition and protocol designs, with reports generated and returned to the scanner in real time. RESULTS: The system demonstrated consistent and repeatable value segmentation and reporting, successfully extracted all 252 T1 and T2 vial samples tested. Values extracted from the same sequence were found to be repeatable with 0.09% ± 1.23% and - 0.26% ± 2.68% intersession error, respectively. DISCUSSION: By providing real-time quantification performance assessment, this easily deployable automated QC approach streamlines sequence validation and long-term performance monitoring, vital for the broader acceptance of qMRI as a standard component of clinical protocols.
RESUMO
OBJECTIVE: This study aims to quantify the repeatability of a 3D Magnetic Resonance Fingerprinting (MRF) research protocol in the context of a scanner software upgrade. All of MRI assumes consistent hardware performance and raw data pre-processing on the acquisition side. Software upgrades can affect hardware specifications and reconstruction chain parameters. Understanding how vendor-provided software upgrades vary MRF-derived T1 and T2 values is crucial for its application in different settings. MATERIALS AND METHODS: Eight healthy volunteers were imaged with an in-house developed 3D MRF pulse sequence using a 3T scanner before and after a software upgrade (VA31A to VA50A, MAGNETOM Vida, Siemens Healthineers). Online MRF reconstruction using Singular Value Decomposition (SVD) timeseries compression and B1+ correction was performed. The study involved test-retest repeatability assessment and a comparison of pre- and post-upgrade data based on automatically extracted T1 and T2 values from MNI-152 Harvard-Oxford Subcortical Structural Atlas regions. RESULTS: Significant mismatches were found directly after the upgrade. However, after an information exchange with the vendor, the 3D-MRF sequence showed consistent repeatability in both intra-version test-retest scenarios and cross-version comparisons: - 1.16 ± 3.18% variability in T1 and - 0.54 ± 4.84% in T2 for intra-version tests, and - 0.83 ± 3.68% (T1) and - 0.05 ± 5.81% (T2) variability for cross-version comparisons. DISCUSSION: The study shows the reliable performance of 3D MRF protocols across software upgrades is possible, but it also highlights the importance of detailed evaluation and vendor collaboration in ensuring consistency. These findings support the application of MRF in longitudinal studies and emphasize the need for systematic assessments following hardware or software modifications.
RESUMO
Standard quantitative abdominal MRI techniques are time consuming, require breath-holds, and are susceptible to patient motion artifacts. Magnetic resonance fingerprinting (MRF) is naturally multi-parametric and quantifies multiple tissue properties, including T1 and T2. This work includes T2* and off-resonance mapping into a free-breathing MRF framework utilizing a pilot tone navigator. The new acquisition and reconstruction are compared to current clinical standards. Prospective. Ten volunteers. 3 T scanner, Quadratic-RF MRF, Balanced SSFP, Inversion recovery spin-echo, LiverLab. MRI ROIs were evaluated in the liver, spleen, pancreas, kidney (cortex and medulla), and paravertebral muscle by two abdominal imaging investigators for ten healthy adult volunteers for clinical standard, breath-Hold (BH) qRF-MRF, and free-breathing qRF-MRF with pilot-tone (PT) acquisitions. Bland-Altman analysis as well as Student's T tests were used to evaluate and compare the respective ROI analyses. Quantitative values between breath-Hold (BH) and free-breathing qRF-MRF with pilot-tone (PT) results show good agreement with clinical standard T1 and T2 quantitative mapping, and Dixon q-VIBE (acquired using the Siemens LiverLAB). In this work, we show free-breathing abdominal MRF (T1, T2) with T2* results that are quantitatively comparable to current breath-hold MRF and clinical techniques.
RESUMO
Magnetic resonance fingerprinting (MRF) is a method to extract quantitative tissue properties such as [Formula: see text] and [Formula: see text] relaxation rates from arbitrary pulse sequences using conventional MRI hardware. MRF pulse sequences have thousands of tunable parameters, which can be chosen to maximize precision and minimize scan time. Here, we perform de novo automated design of MRF pulse sequences by applying physics-inspired optimization heuristics. Our experimental data suggest that systematic errors dominate over random errors in MRF scans under clinically relevant conditions of high undersampling. Thus, in contrast to prior optimization efforts, which focused on statistical error models, we use a cost function based on explicit first-principles simulation of systematic errors arising from Fourier undersampling and phase variation. The resulting pulse sequences display features qualitatively different from previously used MRF pulse sequences and achieve fourfold shorter scan time than prior human-designed sequences of equivalent precision in [Formula: see text] and [Formula: see text] Furthermore, the optimization algorithm has discovered the existence of MRF pulse sequences with intrinsic robustness against shading artifacts due to phase variation.
Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Automação , Encéfalo/diagnóstico por imagem , Simulação por Computador , Epilepsia/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Imagens de FantasmasRESUMO
PURPOSE: To develop a 3D MR fingerprinting (MRF) method in combination with fat navigators to improve its motion robustness for neuroimaging. METHODS: A rapid fat navigator was developed using the stack-of-spirals acquisition and non-Cartesian spiral GRAPPA. The fat navigator module was implemented in the 3D MRF sequence with high scan efficiency. The developed method was first validated in phantoms and five healthy subjects with intentional head motion. The method was further applied to infants with neonatal opioid withdrawal symptoms. The 3D MRF scans with fat navigators acquired with and without acceleration along the partition-encoding direction were both examined in the study. RESULTS: Both phantom and in vivo results demonstrated that the added fat navigator modules did not influence the quantification accuracy in MRF. In combination with non-Cartesian spiral GRAPPA, a rapid fat navigator sampling with whole-brain coverage was achieved in Ë0.5 s at 3T, reducing its sensitivity to potential motion. Based on the motion waveforms extracted from fat navigators, the motion robustness of the 3D MRF was largely improved. With the proposed method, the motion-corrupted MRF datasets yielded T1 and T2 maps with significantly reduced artifacts and high correlations with measurements from the reference motion-free MRF scans. CONCLUSION: We developed a 3D MRF method coupled with rapid fat navigators to improve its motion robustness for quantitative neuroimaging. Our results demonstrate that (1) accurate tissue quantification was preserved with the fat navigator modules and (2) the motion robustness for quantitative tissue mapping was largely improved with the developed method.
Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Recém-Nascido , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Movimento (Física) , Imagens de FantasmasRESUMO
OBJECTIVES: To test the feasibility of using 3D MRF maps with radiomics analysis and machine learning in the characterization of adult brain intra-axial neoplasms. METHODS: 3D MRF acquisition was performed on 78 patients with newly diagnosed brain tumors including 33 glioblastomas (grade IV), 6 grade III gliomas, 12 grade II gliomas, and 27 patients with brain metastases. Regions of enhancing tumor, non-enhancing tumor, and peritumoral edema were segmented and radiomics analysis with gray-level co-occurrence matrices and gray-level run-length matrices was performed. Statistical analysis was performed to identify features capable of differentiating tumors based on type, grade, and isocitrate dehydrogenase (IDH1) status. Receiver operating curve analysis was performed and the area under the curve (AUC) was calculated for tumor classification and grading. For gliomas, Kaplan-Meier analysis for overall survival was performed using MRF T1 features from enhancing tumor region. RESULTS: Multiple MRF T1 and T2 features from enhancing tumor region were capable of differentiating glioblastomas from brain metastases. Although no differences were identified between grade 2 and grade 3 gliomas, differentiation between grade 2 and grade 4 gliomas as well as between grade 3 and grade 4 gliomas was achieved. MRF radiomics features were also able to differentiate IDH1 mutant from the wild-type gliomas. Radiomics T1 features for enhancing tumor region in gliomas correlated to overall survival (p < 0.05). CONCLUSION: Radiomics analysis of 3D MRF maps allows differentiating glioblastomas from metastases and is capable of differentiating glioblastomas from metastases and characterizing gliomas based on grade, IDH1 status, and survival. KEY POINTS: ⢠3D MRF data analysis using radiomics offers novel tissue characterization of brain tumors. ⢠3D MRF with radiomics offers glioma characterization based on grade, IDH1 status, and overall patient survival.
Assuntos
Neoplasias Encefálicas , Glioblastoma , Glioma , Adulto , Humanos , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Neoplasias Encefálicas/patologia , Glioma/patologia , Espectroscopia de Ressonância Magnética , Isocitrato Desidrogenase/genética , Mutação , Gradação de TumoresRESUMO
PURPOSE: To perform B1+$$ {B}_1^{+} $$ -selective excitation using the Bloch-Siegert shift for spatial localization. THEORY AND METHODS: A B1+$$ {B}_1^{+} $$ -selective excitation is produced by an radiofrequency (RF) pulse consisting of two summed component pulses: an off-resonant pulse that induces a B1+$$ {B}_1^{+} $$ -dependent Bloch-Siegert frequency shift and a frequency-selective excitation pulse. The passband of the pulse can be tailored by adjusting the frequency content of the frequency-selective pulse, as in conventional B0$$ {B}_0 $$ gradient-localized excitation. Fine magnetization profile control is achieved by using the Shinnar-Le Roux algorithm to design the frequency-selective excitation pulse. Simulations analyzed the pulses' robustness to off-resonance, their suitability for multi-echo spin echo pulse sequences, and how their performance compares to that of rotating-frame selective excitation pulses. The pulses were evaluated experimentally on a 47.5 mT MRI scanner using an RF gradient transmit coil. Multiphoton resonances produced by the pulses were characterized and their distribution across B1+$$ {B}_1^{+} $$ predicted. RESULTS: With correction for varying B1+$$ {B}_1^{+} $$ across the desired profile, the proposed pulses produced selective excitation with the specified profile characteristics. The pulses were robust against off-resonance and RF amplifier distortion, and suitable for multi-echo pulse sequences. Experimental profiles closely matched simulated patterns. CONCLUSION: The Bloch-Siegert shift can be used to perform B0$$ {B}_0 $$ -gradient-free selective excitation, enabling the excitation of slices or slabs in RF gradient-encoded MRI.
Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Algoritmos , Amplificadores Eletrônicos , Imagens de FantasmasRESUMO
PURPOSE: Although both relaxation and diffusion imaging are sensitive to tissue microstructure, studies have reported limited sensitivity and robustness of using relaxation or conventional diffusion alone to characterize tissue microstructure. Recently, it has been shown that tensor-valued diffusion encoding and joint relaxation-diffusion quantification enable more reliable quantification of compartment-specific microstructural properties. However, scan times to acquire such data can be prohibitive. Here, we aim to simultaneously quantify relaxation and diffusion using MR fingerprinting (MRF) and b-tensor encoding in a clinically feasible time. METHODS: We developed multidimensional MRF scans (mdMRF) with linear and spherical b-tensor encoding (LTE and STE) to simultaneously quantify T1, T2, and ADC maps from a single scan. The image quality, accuracy, and scan efficiency were compared between the mdMRF using LTE and STE. Moreover, we investigated the robustness of different sequence designs to signal errors and their impact on the maps. RESULTS: T1 and T2 maps derived from the mdMRF scans have consistently high image quality, while ADC maps are sensitive to different sequence designs. Notably, the fast imaging steady state precession (FISP)-based mdMRF scan with peripheral pulse gating provides the best ADC maps that are free of image distortion and shading artifacts. CONCLUSION: We demonstrated the feasibility of quantifying T1, T2, and ADC maps simultaneously from a single mdMRF scan in around 24 s/slice. The map quality and quantitative values are consistent with the reference scans.
Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Difusão , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , CintilografiaRESUMO
PURPOSE: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues. METHODS: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same-day test-retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland-Altman analysis. RESULTS: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2 . Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test-retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2 > 0.840). CONCLUSION: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.
Assuntos
Imageamento por Ressonância Magnética , Próstata , Brasil , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: Magnetic resonance fingerprinting (MRF) is a novel, quantitative, and noninvasive technique to measure brain tissue properties. We aim to use MRF for characterizing normal-appearing thalamic and basal ganglia nuclei in the epileptic brain. METHODS: A three-dimensional (3D) MRF protocol (1 mm3 isotropic resolution) was acquired from 48 patients with unilateral medically intractable focal epilepsy and 39 healthy controls (HCs). Whole-brain T1 and T2 maps (containing T1 and T2 relaxation times) were reconstructed for each subject. Ten subcortical nuclei in the thalamus and basal ganglia were segmented as regions of interest (ROIs), within which the mean T1 and T2 values, as well as their coefficient of variation (CV) were compared between the patients and HCs at the group level. Subgroup and correlation analyses were performed to examine the relationship between significant MRF measures and various clinical characteristics. Using significantly abnormal MRF measures from the group-level analyses, support vector machine (SVM) and logistic regression machine learning models were built and tested with 5-fold and 10-fold cross-validations, to separate patients from HCs, and to separate patients with left-sided and right-sided epilepsy, at the individual level. RESULTS: MRF revealed increased T1 mean value in the ipsilateral thalamus and nucleus accumbens; increased T1 CV in the bilateral thalamus, bilateral pallidum, and ipsilateral caudate; and increased T2 CV in the ipsilateral thalamus in patients compared to HCs (p < .05, false discovery rate [FDR] corrected). The SVM classifier produced 78.2% average accuracy to separate individual patients from HCs, with an area under the curve (AUC) of 0.83. The logistic regression classifier produced 67.4% average accuracy to separate patients with left-sided and right-sided epilepsy, with an AUC of 0.72. SIGNIFICANCE: MRF revealed bilateral tissue-property changes in the normal-appearing thalamus and basal ganglia, with ipsilateral predominance and thalamic preference, suggesting subcortical involvement/impairment in patients with medically intractable focal epilepsy. The individual-level performance of the MRF-based machine-learning models suggests potential opportunities for predicting lateralization.
Assuntos
Epilepsia Resistente a Medicamentos , Epilepsias Parciais , Epilepsia , Gânglios da Base/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsias Parciais/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Tálamo/diagnóstico por imagemRESUMO
Background MR fingerprinting (MRF) provides rapid and simultaneous quantification of multiple tissue parameters in a single scan. Purpose To evaluate a rapid kidney MRF technique at 3.0 T in phantoms, healthy volunteers, and patients. Materials and Methods A 15-second kidney MRF acquisition was designed with 12 acquisition segments, a range of low flip angles (5°-12°), multiple magnetization preparation schema (T1, T2, and fat suppression), and an undersampled spiral trajectory. This technique was first validated in vitro using standardized T1 and T2 phantoms. Kidney T1 and T2 maps were then obtained for 10 healthy adult volunteers (mean age ± standard deviation, 35 years ± 13; six men) and three pediatric patients with autosomal recessive polycystic kidney disease (ARPKD) (mean age, 10 years ± 3; two boys) between August 2019 and October 2020 to evaluate the method in vivo. Results Results in nine phantoms showed good agreement with spin-echo-based T1 and T2 values (R2 > 0.99). In vivo MRF kidney T1 and T2 assessments in healthy adult volunteers (cortex: T1, 1362 msec ± 5; T2, 64 msec ± 5; medulla: T1, 1827 msec ± 94; T2, 69 msec ± 3) were consistent with values in the literature but with improved precision in comparison with prior MRF implementations. In vivo MRF-based kidney T1 and T2 values with and without B1 correction were in good agreement (R2 > 0.96, P < .001), demonstrating limited sensitivity to B1 field inhomogeneities. Additional MRF reconstructions using the first nine segments of the MRF profiles (11-second acquisition time) were in good agreement with the reconstructions using 12 segments (15-second acquisition time) (R2 > 0.87, P < .001). Repeat kidney MRF scans for the three patients with ARPKD on successive days also demonstrated good reproducibility (T1 and T2: <3% difference). Conclusion A kidney MR fingerprinting method provided in vivo kidney T1 and T2 maps at 3.0 T in a single breath hold with improved precision and no need for B1 correction. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Laustsen in this issue.
Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Rim Policístico Autossômico Recessivo/diagnóstico por imagem , Adulto , Suspensão da Respiração , Criança , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de FantasmasRESUMO
PURPOSE: This work aims to develop an approach for simultaneous water-fat separation and myocardial T1 and T2 quantification based on the cardiac MR fingerprinting (cMRF) framework with rosette trajectories at 3T and 1.5T. METHODS: Two 15-heartbeat cMRF sequences with different rosette trajectories designed for water-fat separation at 3T and 1.5T were implemented. Water T1 and T2 maps, water image, and fat image were generated with B0 inhomogeneity correction using a B0 map derived from the cMRF data themselves. The proposed water-fat separation rosette cMRF approach was validated in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and water/oil phantoms. It was also applied for myocardial tissue mapping of healthy subjects at both 3T and 1.5T. RESULTS: Water T1 and T2 values measured using rosette cMRF in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom agreed well with the reference values. In the water/oil phantom, oil was well suppressed in the water images and vice versa. Rosette cMRF yielded comparable T1 but 2~3 ms higher T2 values in the myocardium of healthy subjects than the original spiral cMRF method. Epicardial fat deposition was also clearly shown in the fat images. CONCLUSION: Rosette cMRF provides fat images along with myocardial T1 and T2 maps with significant fat suppression. This technique may improve visualization of the anatomical structure of the heart by separating water and fat and could provide value in diagnosing cardiac diseases associated with fibrofatty infiltration or epicardial fat accumulation. It also paves the way toward comprehensive myocardial tissue characterization in a single scan.
Assuntos
Coração , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Água , Coração/diagnóstico por imagem , Humanos , Miocárdio , Imagens de Fantasmas , Reprodutibilidade dos TestesRESUMO
PURPOSE: To implement 3D magnetic resonance fingerprinting (MRF) with quadratic RF phase (qRF-MRF) for simultaneous quantification of T1 , T2 , ΔB0 , and T2∗ . METHODS: 3D MRF data with effective undersampling factor of 3 in the slice direction were acquired with quadratic RF phase patterns for T1 , T2 , and T2∗ sensitivity. Quadratic RF phase encodes the off-resonance by modulating the on-resonance frequency linearly in time. Transition to 3D brings practical limitations for reconstruction and dictionary matching because of increased data and dictionary sizes. Randomized singular value decomposition (rSVD)-based compression in time and reduction in dictionary size with a quadratic interpolation method are combined to be able to process prohibitively large data sets in feasible reconstruction and matching times. RESULTS: Accuracy of 3D qRF-MRF maps in various resolutions and orientations are compared to 3D fast imaging with steady-state precession (FISP) for T1 and T2 contrast and to 2D qRF-MRF for T2∗ contrast and ΔB0 . The precision of 3D qRF-MRF was 1.5-2 times higher than routine clinical scans. 3D qRF-MRF ΔB0 maps were further processed to highlight the susceptibility contrast. CONCLUSION: Natively co-registered 3D whole brain T1 , T2 , T2∗ , ΔB0 , and QSM maps can be acquired in as short as 5 min with 3D qRF-MRF.
Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Espectroscopia de Ressonância Magnética , Imagens de FantasmasRESUMO
Magnetic resonance fingerprinting (MRF) is an evolving quantitative MRI framework consisting of unique data acquisition, processing, visualization, and interpretation steps. MRF is capable of simultaneously producing multiple high-resolution property maps including T1, T2, M0, ADC, and T2* measurements. While a relatively new technology, MRF has undergone rapid development for a variety of clinical applications from brain tumor characterization and epilepsy imaging to characterization of prostate cancer, cardiac imaging, among others. This paper will provide a brief overview of current state of MRF technology including highlights of technical and clinical advances. We will conclude with a brief discussion of the challenges that need to be overcome to establish MRF as a quantitative imaging biomarker.
Assuntos
Neoplasias Encefálicas , Epilepsia , Encéfalo , Técnicas de Imagem Cardíaca , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Imagens de FantasmasRESUMO
PURPOSE: This is a radiomics study investigating the ability of texture analysis of MRF maps to improve differentiation between intra-axial adult brain tumors and to predict survival in the glioblastoma cohort. METHODS: Magnetic resonance fingerprinting (MRF) acquisition was performed on 31 patients across 3 groups: 17 glioblastomas, 6 low-grade gliomas, and 8 metastases. Using regions of interest for the solid tumor and peritumoral white matter on T1 and T2 maps, second-order texture features were calculated from gray-level co-occurrence matrices and gray-level run length matrices. Selected features were compared across the three tumor groups using Wilcoxon rank-sum test. Receiver operating characteristic curve analysis was performed for each feature. Kaplan-Meier method was used for survival analysis with log rank tests. RESULTS: Low-grade gliomas and glioblastomas had significantly higher run percentage, run entropy, and information measure of correlation 1 on T1 than metastases (p < 0.017). The best separation of all three tumor types was seen utilizing inverse difference normalized and homogeneity values for peritumoral white matter in both T1 and T2 maps (p < 0.017). In solid tumor T2 maps, lower values in entropy and higher values of maximum probability and high-gray run emphasis were associated with longer survival in glioblastoma patients (p < 0.05). Several texture features were associated with longer survival in glioblastoma patients on peritumoral white matter T1 maps (p < 0.05). CONCLUSION: Texture analysis of MRF-derived maps can improve our ability to differentiate common adult brain tumors by characterizing tumor heterogeneity, and may have a role in predicting outcomes in patients with glioblastoma.
Assuntos
Neoplasias Encefálicas , Glioblastoma , Glioma , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Glioblastoma/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância MagnéticaRESUMO
BACKGROUND: Quantitative T1 and T2 mapping in the abdomen provides valuable information in tissue characterization but is technically challenging due to respiratory motions. The proposed technique integrates magnetic resonance fingerprinting (MRF) and pilot tone (PT) navigator with retrospective gating to provide simultaneous quantification of multiple tissue properties in a single acquisition without breath-holding or patient set-up. PURPOSE: To develop a free-breathing abdominal MRF technique for quantitative mapping in the abdomen. STUDY TYPE: Prospective. POPULATION: Twelve healthy volunteers. FIELD STRENGTH/SEQUENCE: A 3 T, two-dimensional (2D) and three-dimensional (3D) spiral MRF sequence with fast imaging with steady-state free precession (FISP) readout. ASSESSMENT: The PT navigator was compared to standard respiratory belt performance. The T1 and T2 values acquired using 2D and 3D MRF with and without PT were obtained in a phantom and compared to reference values. Digital phantom simulation was performed to evaluate PT MRF reconstruction with varying breathing patterns. In the in vivo studies, T1 and T2 values derived from PT 2D MRF were compared to 2D breath-hold MRF. T1 and T2 values derived from PT 3D MRF were compared to published values. STATISTICAL TESTS: Principal component analysis (PCA), linear regression, relative error, Pearson correlation, paired Student's t-test, Bland-Altman Analysis. RESULTS: The phantom study showed PT MRF T1 values had a mean difference of 0.2% ± 0.1%, and T2 values had a mean difference of 0.1% ± 0.4% when compared to no-PT MRF values. The digital phantom experiment suggested the T1 and T2 maps at both end-exhalation and end-inhalation states resemble the corresponding ground-truth maps. DATA CONCLUSION: The phantom study showed good agreement between MRF T1 and T2 values and with reference values. In vivo studies demonstrated that 2D and 3D quantitative imaging in the abdomen could be achieved with integration of PT navigation with MRF reconstruction using retrospective gating of respiratory motion. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
Assuntos
Suspensão da Respiração , Imageamento por Ressonância Magnética , Abdome/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Estudos Prospectivos , Estudos RetrospectivosRESUMO
This study introduces a technique called cine magnetic resonance fingerprinting (cine-MRF) for simultaneous T1 , T2 and ejection fraction (EF) quantification. Data acquired with a free-running MRF sequence are retrospectively sorted into different cardiac phases using an external electrocardiogram (ECG) signal. A low-rank reconstruction with a finite difference sparsity constraint along the cardiac motion dimension yields images resolved by cardiac phase. To improve SNR and precision in the parameter maps, these images are nonrigidly registered to the same phase and matched to a dictionary to generate T1 and T2 maps. Cine images for computing left ventricular volumes and EF are also derived from the same data. Cine-MRF was tested in simulations using a numerical relaxation phantom. Phantom and in vivo scans of 19 subjects were performed at 3 T during a 10.9 seconds breath-hold with an in-plane resolution of 1.6 x 1.6 mm2 and 24 cardiac phases. Left ventricular EF values obtained with cine-MRF agreed with the conventional cine images (mean bias -1.0%). Average myocardial T1 times in diastole/systole were 1398/1391 ms with cine-MRF, 1394/1378 ms with ECG-triggered cardiac MRF (cMRF) and 1234/1212 ms with MOLLI; and T2 values were 30.7/30.3 ms with cine-MRF, 32.6/32.9 ms with ECG-triggered cMRF and 37.6/41.0 ms with T2 -prepared FLASH. Cine-MRF and ECG-triggered cMRF relaxation times were in good agreement. Cine-MRF T1 values were significantly longer than MOLLI, and cine-MRF T2 values were significantly shorter than T2 -prepared FLASH. In summary, cine-MRF can potentially streamline cardiac MRI exams by combining left ventricle functional assessment and T1 -T2 mapping into one time-efficient acquisition.