Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Hum Reprod ; 39(5): 1078-1088, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38503490

RESUMO

STUDY QUESTION: Is resumption of ovulation after a 6-month lifestyle intervention in women with PCOS and obesity associated with differential changes in endocrine and metabolic parameters (weight, insulin resistance, anti-Müllerian hormone (AMH), and androgens) compared to women with PCOS who remained anovulatory? SUMMARY ANSWER: Resumption of ovulation after a 6-month lifestyle intervention in women with PCOS and obesity is associated with changes in serum 11ß-hydroxyandrostenedione (11OHA4) concentrations. WHAT IS KNOWN ALREADY: Lifestyle interventions have been shown to reduce clinical and biochemical hyperandrogenism in women with PCOS. Weight loss of 5-10% may reverse anovulatory status, thereby increasing natural conception rates. However, the mechanisms underlying why some women with PCOS remain anovulatory and others resume ovulation after weight loss are unclear. Reproductive characteristics at baseline and a greater degree of change in endocrine and metabolic features with lifestyle intervention may be crucial for ovulatory response. STUDY DESIGN, SIZE, DURATION: We used data and samples originating from an earlier randomized controlled trial (RCT), which examined the efficacy of a 6-month lifestyle intervention prior to infertility treatment compared to prompt infertility treatment on live birth rate in women with obesity. A total of 577 women with obesity (BMI > 29 kg/m2) were randomized between 2009 and 2012. Anovulatory women with PCOS who were allocated to the intervention arm of the original RCT (n = 95) were included in the current analysis. PARTICIPANTS/MATERIALS, SETTING, METHODS: We defined women as having resumed ovulation (RO+) based on the following criteria: spontaneous pregnancy; or assignment to expectant management; or IUI in natural cycles as the treatment strategy after lifestyle intervention. Steroid hormones were measured using liquid chromatography tandem mass spectrometry. Generalized estimating equations with adjustment for baseline measures and interaction between group and time was used to examine differences in changes of endocrine and metabolic parameters between RO+ (n = 34) and persistently anovulatory women (RO-, n = 61) at 3 and 6 months after intervention. MAIN RESULTS AND THE ROLE OF CHANCE: At baseline, the mean ± SD age was 27.5 ± 3.6 years in the RO+ group and 27.9 ± 4.1 years in the RO- group (P = 0.65), and the mean ± SD weights were 101.2 ± 9.5 kg and 105.0 ± 14.6 kg, respectively (P = 0.13). Baseline AMH concentrations showed significant differences between RO+ and RO- women (median and interquartile range [IQR] 4.7 [3.2; 8.3] versus 7.2 [5.3; 10.8] ng/ml, respectively). Baseline androgen concentrations did not differ between the two groups. During and after lifestyle intervention, both groups showed weight loss; changes in 11OHA4 were significantly different between the RO+ and RO groups (P-value for interaction = 0.03). There was a similar trend for SHBG (interaction P-value = 0.07), and DHEA-S (interaction P-value = 0.06), with the most pronounced differences observed in the first 3 months. Other parameters, such as AMH and FAI, decreased over time but with no difference between the groups. LIMITATIONS, REASONS FOR CAUTION: No high-resolution transvaginal ultrasonography was used to confirm ovulatory status at the end of the lifestyle program. The small sample size may limit the robustness of the results. WIDER IMPLICATIONS OF THE FINDINGS: Reduction of androgen concentrations during and after lifestyle intervention is associated with recovery of ovulatory cycles. If our results are confirmed in other studies, androgen concentrations could be monitored during lifestyle intervention to provide individualized recommendations on the timing of resumption of ovulation in anovulatory women with PCOS and obesity. STUDY FUNDING/COMPETING INTEREST(S): The study was supported by a grant from ZonMw, the Dutch Organization for Health Research and Development (50-50110-96-518). The Department of Obstetrics and Gynecology of the UMCG received an unrestricted educational grant from Ferring Pharmaceuticals BV, The Netherlands. A.H. reports consultancy for the development and implementation of a lifestyle App MyFertiCoach developed by Ferring Pharmaceutical Company. All other authors have no conflicts to declare. TRIAL REGISTRATION NUMBER: The LIFEstyle RCT was registered at the Dutch trial registry (NTR 1530).


Assuntos
Anovulação , Obesidade , Ovulação , Síndrome do Ovário Policístico , Humanos , Feminino , Obesidade/complicações , Obesidade/terapia , Adulto , Síndrome do Ovário Policístico/complicações , Síndrome do Ovário Policístico/terapia , Androstenodiona/sangue , Resistência à Insulina , Gravidez , Hormônio Antimülleriano/sangue , Redução de Peso
2.
J Robot Surg ; 18(1): 54, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38280064

RESUMO

Robot-assisted surgery is increasingly used in surgery for cancer. Reduced overview and loss of anatomical orientation are challenges that might be solved with image-guided surgical navigation using electromagnetic tracking (EMT). However, the robot's presence may distort the electromagnetic field, affecting EMT accuracy. The aim of this study was to evaluate the robot's influence on EMT accuracy. For this purpose, two different electromagnetic field generators were used inside a clinical surgical environment: a table top field generator (TTFG) and a planar field generator (PFG). The position and orientation of sensors within the electromagnetic field were measured using an accurate in-house developed 3D board. Baseline accuracy was measured without the robot, followed by stepwise introduction of potential distortion sources (robot and robotic instruments). The absolute accuracy was determined within the entire 3D board and in the clinical working volume. For the baseline setup, median errors in the entire tracking volume within the 3D board were 0.9 mm and 0.3° (TTFG), and 1.1 mm and 0.4° (PFG). Adding the robot and instruments did not affect the TTFG's position accuracy (p = 0.60), while the PFG's accuracies decreased to 1.5 mm and 0.7° (p < 0.001). For both field generators, when adding robot and instruments, accuracies inside the clinical working volume were higher compared to the entire tracking 3D board volume, 0.7 mm and 0.3° (TTFG), and 1.1 mm and 0.7° (PFG). Introduction of a surgical robot and robotic instruments shows limited distortion of the EMT field, allowing sufficient accuracy for surgical navigation in robotic procedures.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Fenômenos Eletromagnéticos , Cirurgia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA