Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Transplant ; 20(4): 967-976, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31710417

RESUMO

Ex vivo lung perfusion (EVLP) with pharmacological reconditioning may increase donor lung utilization for transplantation (LTx). 3-Aminobenzamide (3-AB), an inhibitor of poly(ADP-ribose) polymerase (PARP), reduces ex vivo lung injury in rat lungs damaged by warm ischemia (WI). Here we determined the effects of 3-AB reconditioning on graft outcome after LTx. Three groups of donor lungs were studied: Control (Ctrl): 1 hour WI + 3 hours cold ischemia (CI) + LTx; EVLP: 1 hour WI + 3 hours EVLP + LTx; EVLP + 3-AB: 1 hour WI + 3 hours EVLP + 3-AB (1 mg. mL-1 ) + LTx. Two hours after LTx, we determined lung graft compliance, edema, histology, neutrophil counts in bronchoalveolar lavage (BAL), mRNA levels of adhesion molecules within the graft, as well as concentrations of interleukin-6 and 10 (IL-6, IL-10) in BAL and plasma. 3-AB reconditioning during EVLP improved compliance and reduced lung edema, neutrophil infiltration, and the expression of adhesion molecules within the transplanted lungs. 3-AB also attenuated the IL-6/IL-10 ratio in BAL and plasma, supporting an improved balance between pro- and anti-inflammatory mediators. Thus, 3-AB reconditioning during EVLP of rat lung grafts damaged by WI markedly reduces inflammation, edema, and physiological deterioration after LTx, supporting the use of PARP inhibitors for the rehabilitation of damaged lungs during EVLP.


Assuntos
Circulação Extracorpórea , Transplante de Pulmão , Animais , Benzamidas , Pulmão , Transplante de Pulmão/efeitos adversos , Perfusão , Ratos
2.
Lasers Surg Med ; 49(8): 773-780, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28544068

RESUMO

BACKGROUND: Low-dose photodynamic therapy PDT (photoinduction) can modulate tumor vessels and enhance the uptake of liposomal cisplatin (Lipoplatin®) in pleural malignancies. However, the photo-induction conditions must be tightly controlled as overtreatment shuts down tumor vessels and enhances normal tissue drug uptake. MATERIAL AND METHODS: In a pleural sarcoma and adenocarcinoma rat model (n = 12/group), we applied photoinduction (0.0625 mg/kg Visudyne®, 10 J/cm2 ) followed by intravenous Lipoplatin® (5 mg/kg) administration. Tumor and normal tissue IFP were assessed before and up to 1 hour following photoinduction. Lipoplatin® uptake was determined 60 minutes following photoinduction. We then treated the pleura of tumor-free minipigs with high dose photodynamic therapy (PDT) (0.0625 mg/kg Visudyne®, 30 J/cm2 , n = 5) followed by Lipoplatin (5 mg/kg) administration. RESULTS: In rodents, photoinduction resulted in a significant decrease of IFP (P < 0.05) in both tumor types but not in the surrounding normal lung, equally exposed to light. Also, photoinduction resulted in a significant increase of Lipoplatin® uptake in both tumor types (P < 0.05) but not in normal lung. Tumor IFP variation and Lipoplatin® uptake fitted an inverted parabola. In minipigs, high dose photodynamic treatment resulted in pleural IFP increase of some animals which predicted higher Lipoplatin® uptake levels. CONCLUSION: Normal and tumor vasculatures react differently to PDT. Continuous IFP monitoring in normal and tumor tissues is a promising biomarker of vessel photoinduction. Moderate drop in tumor with no change in normal tissue IFP are predictive of specific Lipoplatin® uptake by cancer following PDT. Lasers Surg. Med. 49:773-780, 2017. © 2017 Wiley Periodicals, Inc.


Assuntos
Adenocarcinoma/tratamento farmacológico , Antineoplásicos/farmacocinética , Cisplatino/farmacocinética , Líquido Extracelular/fisiologia , Fotoquimioterapia/métodos , Neoplasias Pleurais/tratamento farmacológico , Sarcoma/tratamento farmacológico , Adenocarcinoma/metabolismo , Animais , Antineoplásicos/uso terapêutico , Biomarcadores , Linhagem Celular Tumoral , Cisplatino/uso terapêutico , Injeções Intravenosas , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Neoplasias Pleurais/metabolismo , Porfirinas/uso terapêutico , Pressão , Ratos , Ratos Endogâmicos F344 , Sarcoma/metabolismo , Suínos , Verteporfina
3.
Thorac Cardiovasc Surg ; 65(2): 126-129, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27050813

RESUMO

Acute spinal cord ischemia during thoracoabdominal aorta replacement is a dreadful complication. Existing tools (motor evoked potential [MEP] and somatosensory evoked potential [SSEP]) do not allow differentiating between central and peripheral paraplegia. Therefore, the surgeon often performs unnecessary reimplantation of intercostal arteries: this is time consuming, and significantly increases bleeding complications. We present a simple technique combining MEP and peripheral compound muscle action potential induced by posterior tibialis nerve stimulation, enabling the surgeon to quickly discriminate between central and peripheral neurologic injury. The surgeon has one more tool to drive in real time the optimal surgical strategy. This strategy guides the decision as to which side branches ought to be reimplanted, thus minimizing the risk of paraplegia.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Potencial Evocado Motor , Monitorização Neurofisiológica Intraoperatória/métodos , Paraplegia/prevenção & controle , Isquemia do Cordão Espinal/prevenção & controle , Traumatismos do Sistema Nervoso/prevenção & controle , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Estimulação Elétrica , Humanos , Monitoração Neuromuscular , Paraplegia/diagnóstico , Paraplegia/etiologia , Paraplegia/fisiopatologia , Valor Preditivo dos Testes , Reimplante , Fatores de Risco , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/fisiopatologia , Artérias Torácicas/cirurgia , Nervo Tibial , Traumatismos do Sistema Nervoso/diagnóstico , Traumatismos do Sistema Nervoso/etiologia , Traumatismos do Sistema Nervoso/fisiopatologia , Resultado do Tratamento , Fluxo de Trabalho
4.
J Card Surg ; 32(3): 222-228, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28198093

RESUMO

We report the use of a total extracorporeal heart for uncontrolled bleeding following a proximal left anterior descending artery perforation, using two centrifugal ventricular assist devices after heart explantation. The literature describing similar techniques and patient outcomes for this "bailout" technique are reviewed.


Assuntos
Vasos Coronários/lesões , Coração Auxiliar , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/terapia , Hemorragia Pós-Operatória/terapia , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Pericárdio , Hemorragia Pós-Operatória/etiologia , Resultado do Tratamento
5.
World J Surg Oncol ; 14: 25, 2016 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-26837543

RESUMO

Extracorporeal assistances are exponentially used for patients, with acute severe but reversible heart or lung failure, to provide more prolonged support to bridge patients to heart and/or lung transplantation. However, experience of use of extracorporeal assistance for pulmonary resection is limited outside lung transplantation. Airways management with standard mechanical ventilation system may be challenging particularly in case of anatomical reasons (single lung), presence of respiratory failure (ARDS), or complex tracheo-bronchial resection and reconstruction. Based on the growing experience during lung transplantation, more and more surgeons are now using such devices to achieve good oxygenation and hemodynamic support during such challenging cases. We review the different extracorporeal device and attempt to clarify the current practice and indications of extracorporeal support during pulmonary resection.


Assuntos
Oxigenação por Membrana Extracorpórea , Pneumopatias/cirurgia , Transplante de Pulmão , Humanos , Prognóstico
6.
Lasers Surg Med ; 47(10): 807-16, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26415084

RESUMO

BACKGROUND: Low-dose, Visudyne®-mediated photodynamic therapy (photo-induction) was shown to selectively enhance tumor vessel transport causing increased uptake of systemically administered chemotherapy in various tumor types grown on rodent lungs. The present experiments explore the efficacy of photo-induced vessel modulation combined to intravenous (IV) liposomal cisplatin (Lipoplatin®) on rodent lung tumors and the feasibility/toxicity of this approach in porcine chest cavities. MATERIAL AND METHODS: Three groups of Fischer rats underwent orthotopic sarcoma (n = 14), mesothelioma (n = 14), or adenocarcinoma (n = 12) implantation on the left lung. Half of the animals of each group had photo-induction (0.0625 mg/kg Visudyne®, 10 J/cm(2) ) followed by IV administration of Lipoplatin® (5 mg/kg) and the other half received Lipoplatin® without photo-induction. Then, two groups of minipigs underwent intrapleural thoracoscopic (VATS) photo-induction (0.0625 mg/kg Visudyne®; 30 J/cm(2) hilum; 10 J/cm(2) apex/diaphragm) with in situ light dosimetry in combination with IV Lipoplatin® administration (5 mg/kg). Protocol I (n = 6) received Lipoplatin® immediately after light delivery and Protocol II (n = 9) 90 minutes before light delivery. Three additional animals received Lipoplatin® and VATS pleural biopsies but no photo-induction (controls). Lipoplatin® concentrations were analyzed in blood and tissues before and at regular intervals after photo-induction using inductively coupled plasma mass spectrometry. RESULTS: Photo-induction selectively increased Lipoplatin® uptake in all orthotopic tumors. It significantly increased the ratio of tumor to lung Lipoplatin® concentration in sarcoma (P = 0.0008) and adenocarcinoma (P = 0.01) but not in mesothelioma, compared to IV drug application alone. In minipigs, intrapleural photo-induction combined to systemic Lipoplatin® was well tolerated with no toxicity at 7 days for both treatment protocols. The pleural Lipoplatin® concentrations were not significantly different at 10 and 30 J/cm(2) locations but they were significantly higher in protocol I compared to II (2.37 ± 0.7 vs. 1.37 ± 0.7 ng/mg, P < 0.001). CONCLUSION: Visudyne®-mediated photo-induction selectively enhances the uptake of IV administered Lipoplatin® in rodent lung tumors. Intrapleural VATS photo-induction with identical treatment conditions combined to IV Lipoplatin chemotherapy is feasible and well tolerated in a porcine model. Lasers Surg. Med. 47:807-816, 2015. © 2015 Wiley Periodicals, Inc.


Assuntos
Antineoplásicos/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Cisplatino/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Porfirinas/uso terapêutico , Adenocarcinoma/tratamento farmacológico , Animais , Antineoplásicos/farmacocinética , Linhagem Celular Tumoral , Cisplatino/farmacocinética , Esquema de Medicação , Estudos de Viabilidade , Masculino , Mesotelioma/tratamento farmacológico , Transplante de Neoplasias , Fármacos Fotossensibilizantes/farmacocinética , Porfirinas/farmacocinética , Ratos , Ratos Endogâmicos F344 , Sarcoma/tratamento farmacológico , Suínos , Resultado do Tratamento , Verteporfina
7.
Eur J Anaesthesiol ; 31(2): 68-75, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23867776

RESUMO

BACKGROUND: Rotational thromboelastometry (ROTEM) is a whole blood point-of-test used to assess the patient's coagulation status. Three of the available ROTEM tests are EXTEM, INTEM and HEPTEM. In the latter, heparinase added to the INTEM reagent inactivates heparin to reveal residual heparin effect. Performing ROTEM analysis during cardiopulmonary bypass (CPB) might allow the anaesthesiologist to anticipate the need for blood products. OBJECTIVE: The goal of this study was to validate ROTEM analysis in the presence of very high heparin concentrations during CPB. DESIGN: Prospective, observational trial. SETTING: Single University Hospital. PARTICIPANTS: Twenty patients undergoing coronary artery bypass grafting. MAIN OUTCOME MEASURE: ROTEM analysis was performed before heparin administration (T0), 10 min after heparin (T1), at the end of CPB (T2) and 10 min after protamine (T3). The following tests were performed: EXTEM, INTEM, and HEPTEM. Heparin concentrations were measured at T1 and at the end of bypass (T2). RESULTS: At T1, EXTEM differed from baseline for coagulation time: +26.7 s (18.4 to 34.9, P < 0.0001), α: -3° (1.0 to 5.4, P = 0.006) and A10: -4.4 mm (2.3 to 6.5, P = 0.0004). INTEM at T0 was different from HEPTEM at T1 for coagulation time: + 47 s (34.3 to 59.6, P > 0.0001), A10: -2.3 mm (0.5 to 4.0, P = 0.01) and α -2° (1.0 to 3.0; P = 0.0007). At T2, all parameters in EXTEM and HEPTEM related to fibrin-platelet interaction deteriorated significantly compared to T1. At T3, EXTEM and INTEM were comparable to EXTEM and HEPTEM at T2. CONCLUSION: HEPTEM and EXTEM measurements are valid in the presence of very high heparin concentrations and can be performed before protamine administration in patients undergoing cardiac surgery with CPB. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01455454.


Assuntos
Anestesiologia/métodos , Ponte Cardiopulmonar/métodos , Heparina/uso terapêutico , Protaminas/uso terapêutico , Tromboelastografia/métodos , Idoso , Algoritmos , Animais , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Inibidores do Fator Xa , Feminino , Hemostasia , Antagonistas de Heparina/farmacologia , Heparina Liase/química , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Rotação , Suínos , Resultado do Tratamento , Tempo de Coagulação do Sangue Total
8.
Eur J Anaesthesiol ; 31(9): 499-504, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25010745

RESUMO

BACKGROUND: Multiple electrode aggregometry (MEA) is a point-of-care test evaluating platelet function and the efficacy of platelet inhibitors. In MEA, electrical impedance of whole blood is measured after addition of a platelet activator. Reduced impedance implies platelet dysfunction or the presence of platelet inhibitors. MEA plays an increasingly important role in the management of perioperative platelet dysfunction. In vitro, midazolam, propofol, lidocaine and magnesium have known antiplatelet effects and these may interfere with MEA interpretation. OBJECTIVE: To evaluate the extent to which MEA is modified in the presence of these drugs. DESIGN: An in-vitro study using blood collected from healthy volunteers. SETTING: Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland, 2010 to 2011. PATIENTS: Twenty healthy volunteers. INTERVENTION: Measurement of baseline MEA was using four activators: arachidonic acid, ADP, TRAP-6 and collagen. The study drugs were then added in three increasing, clinically relevant concentrations. MAIN OUTCOME MEASURE: MEA was compared with baseline for each study drug. RESULTS: Midazolam, propofol and lidocaine showed no effect on MEA at any concentration. Magnesium at 2.5 mmol l had a significant effect on the ADP and TRAP tests (31 ±â€Š13 and 96 ±â€Š39 AU, versus 73 ±â€Š21 and 133 ±â€Š28 AU at baseline, respectively), and a less pronounced effect at 1 mmol l on the ADP test (39 ±â€Š0 AU). CONCLUSION: Midazolam, propofol and lidocaine do not interfere with MEA measurement. In patients treated with high to normal doses of magnesium, MEA results for ADP and TRAP-tests should be interpreted with caution. TRIAL REGISTRATION: Clinicaltrials.gov (no. NCT01454427).


Assuntos
Difosfato de Adenosina/metabolismo , Anestésicos/farmacologia , Agregação Plaquetária/efeitos dos fármacos , Adulto , Anestésicos/administração & dosagem , Procedimentos Cirúrgicos Cardíacos/métodos , Relação Dose-Resposta a Droga , Impedância Elétrica , Eletrodos , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade
9.
J Thorac Dis ; 10(10): 5879-5888, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30505496

RESUMO

BACKGROUND: Enhanced recovery after surgery (ERAS) programs have been reported to decrease complications and shorten hospital stays after lung resections, but their implementation requires time and financial investment with dedicated staff. The aim of this study was to evaluate the clinical and economic outcomes of video-assisted thoracoscopic surgery (VATS) anatomical pulmonary resections before and after implementation of an ERAS program. METHODS: The first 50 consecutive patients undergoing VATS lobectomy or segmentectomy for malignancy after implementation of an ERAS program were compared with 50 consecutive patients treated before its introduction. The ERAS protocol included preoperative counseling, reduced preoperative fasting with concomitant carbohydrate loading, avoidance of premedication, standardized surgery, anesthesia and postoperative analgesia, early removal of chest tube, nutrition and mobilization. Length of stay, readmissions and cardio-pulmonary complications within 30 days were compared. Total costs were collected for each patient and a cost-minimization analysis integrating ERAS-specific costs was performed. RESULTS: Both groups were similar in terms of demographics and surgical characteristics. The ERAS group had significantly shorter postoperative length of stay (median: 4 vs. 7 days, P<0.0001), decreased pulmonary complications (16% vs. 38%; P=0.01) and decreased overall post-operative complications (24% vs. 48%, P=0.03). One patient in each group was readmitted and there was no 30-day mortality. ERAS-specific costs were calculated at €729 per patient including the clinical nurse and database costs. Average total hospitalization costs were significantly lower in ERAS group (€15,945 vs. €20,360, P<0.0001), mainly due to lower costs during the post-operative period (€7,449 vs. €11,454, P<0.0001) in comparison with the intra-operative period (€8,496 vs. €8,906, P=0.303). Cost-minimization analysis showed a mean saving in the ERAS group of €3,686 per patient. CONCLUSIONS: An ERAS program for VATS anatomical lung resection is cost-effective and is associated with a lower complication rate and a shorter postoperative hospitalization.

10.
Interact Cardiovasc Thorac Surg ; 26(6): 977-984, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29373667

RESUMO

OBJECTIVES: Volatile anaesthetics can provide significant protection against reperfusion injury in various experimental settings. The aim of this study was to assess the potential of sevoflurane treatment, the most commonly used volatile anaesthetic in modern anaesthesia, in rat lungs donated after circulatory death and reconditioned in an ex vivo lung perfusion (EVLP) system. METHODS: Fifteen rats were sacrificed and divided into 3 groups. In the control and sevoflurane groups, the heart-lung blocks were exposed to 1 h of warm ischaemia and 2 h of cold ischaemia and were mounted on an EVLP circuit for 3 h, in the absence or in the presence of 2% sevoflurane. In the baseline group, heart-lung blocks were harvested immediately after euthanasia. Physiological data, lung nitro-oxidative stress, lactate dehydrogenase (LDH), expression of cytokines, oedema and histopathological findings were assessed during or post-EVLP. RESULTS: The sevoflurane group showed significantly reduced LDH (8.82 ± 3.58 arbitrary unit vs 3.80 ± 3.02 arbitrary unit, P = 0.03), protein carbonyl (1.17 ± 0.44 nmol⋅mg-1 vs 0.55 ± 0.11 nmol⋅mg-1, P = 0.006), 3-nitrotyrosine (197.44 ± 18.47 pg⋅mg-1 vs 151.05 ± 23.54 pg⋅mg-1, P = 0.004), cytokine-induced neutrophil chemoattractant factor 1 (1.17 ± 0.32 ng⋅mg-1 vs 0.66 ± 0.28 ng⋅mg-1, P = 0.03) and tumour necrosis factor alpha (1.50 ± 0.59 vs 0.59 ± 0.38 ng⋅mg-1, P = 0.02) when compared with the control group. In addition, sevoflurane lungs gained significantly less weight (0.72 ± 0.09 g vs 0.72 ± 0.09 g, P = 0.044), had less perivascular oedema (0.58 ± 0.09 vs 0.47 ± 0.07, P = 0.036), and improved static pulmonary compliance (+0.215 ml⋅cmH2O-1, P = 0.003) and peak airways pressure (-1.33 cmH2O, P = 0.04) but similar oxygenation capacity (+1.61 mmHg, P = 0.77) and pulmonary vascular resistances (+0.078 mmHg⋅min⋅ml-1, P = 0.15) when compared with the control group. CONCLUSIONS: These findings suggest that the potential of sevoflurane in protecting the lungs donated after cardiac death and reconditioned using EVLP could improve the outcome of these lungs following subsequent transplantation.


Assuntos
Transplante de Pulmão/efeitos adversos , Pulmão/fisiopatologia , Traumatismo por Reperfusão/terapia , Sevoflurano/administração & dosagem , Doadores de Tecidos , Anestésicos Inalatórios/administração & dosagem , Animais , Modelos Animais de Doenças , Circulação Extracorpórea , Masculino , Perfusão/métodos , Ratos
11.
ASAIO J ; 63(6): 752-758, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28557861

RESUMO

New generation devices for long-term mechanical circulatory support are centrifugal pumps having fully magnetically levitated rotors to reduce blood trauma. Recently, the novel HeartMate 3 was cleared for clinical application in Switzerland. In two Swiss University Hospitals part of the "Lausanne-Geneva Transplantation Network," 10 consecutive patients in end-stage heart failure received the HeartMate 3 (Thoratec Corporation, Pleasanton, CA). Device implantation criteria were persistent low output syndrome despite optimal medical treatment. The primary end-point of the study was survival or transplantation to 90 days on the device. Five patients (50%) were in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) class 1 and 2 (two were under venoarterial extracorporeal membrane oxygenation [VA-ECMO]), and five were in class 3 and 4. The indication was bridge-to-transplant in seven patients, and destination therapy in three. Two patients (20%) received concomitant aortic valve surgery. Four patients (40%) required temporary right ventricle support (tRVAD) for a mean of 8 ± 1.5 days. Bleeding requiring surgical revision occurred in five (50%) patients, two during the tRVAD support. At the 90 day end-point, survival was 90%, one (10%) died due to respiratory failure. Three (30%) experienced critical illness polyneuropathy. Two had body temperature over 38.5°C for more than 7 days after implant, without infections. Two (20%) had late driveline infection. The pump allowed rapid improvement of patients' clinical conditions even in severely compromised patients. Postoperative bleeding occurred in the setting of anticoagulation. No hemolysis or pump thrombosis occurred. Fever occurred frequently but was not associated with mortality. Hemodynamic support was consistent over time without significant adverse events.


Assuntos
Coração Auxiliar/efeitos adversos , Adulto , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros
12.
PLoS One ; 12(3): e0173916, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28323904

RESUMO

Damaged lung grafts obtained after circulatory death (DCD lungs) and warm ischemia may be at high risk of reperfusion injury after transplantation. Such lungs could be pharmacologically reconditioned using ex-vivo lung perfusion (EVLP). Since acute inflammation related to the activation of nuclear factor kappaB (NF-κB) is instrumental in lung reperfusion injury, we hypothesized that DCD lungs might be treated during EVLP by pyrrolidine dithiocarbamate (PDTC), an inhibitor of NF-κB. Rat lungs exposed to 1h warm ischemia and 2 h cold ischemia were subjected to EVLP during 4h, in absence (CTRL group, N = 6) or in presence of PDTC (2.5g/L, PDTC group, N = 6). Static pulmonary compliance (SPC), peak airway pressure (PAWP), pulmonary vascular resistance (PVR), and oxygenation capacity were determined during EVLP. After EVLP, we measured the weight gain of the heart-lung block (edema), and the concentration of LDH (cell damage), proteins (permeability edema) and of the cytokines IL-6, TNF-α and CINC-1 in bronchoalveolar lavage (BAL), and we evaluated NF-κB activation by the degree of phosphorylation and degradation of its inhibitor IκBα in lung tissue. In CTRL, we found significant NF-κB activation, lung edema, and a massive release of LDH, proteins and cytokines. SPC significantly decreased, PAWP and PVR increased, while oxygenation tended to decrease. Treatment with PDTC during EVLP inhibited NF-κB activation, did not influence LDH release, but markedly reduced lung edema and protein concentration in BAL, suppressed TNFα and IL-6 release, and abrogated the changes in SPC, PAWP and PVR, with unchanged oxygenation. In conclusion, suppression of innate immune activation during EVLP using the NF-κB inhibitor PDTC promotes significant improvement of damaged rat DCD lungs. Future studies will determine if such rehabilitated lungs are suitable for in vivo transplantation.


Assuntos
Lesão Pulmonar/reabilitação , Transplante de Pulmão/métodos , Pirrolidinas/administração & dosagem , Traumatismo por Reperfusão/reabilitação , Tiocarbamatos/administração & dosagem , Animais , Antioxidantes/administração & dosagem , Líquido da Lavagem Broncoalveolar/imunologia , Citocinas/metabolismo , Modelos Animais de Doenças , Imunidade Inata/efeitos dos fármacos , Técnicas In Vitro , Pulmão/imunologia , Pulmão/fisiopatologia , Lesão Pulmonar/imunologia , Lesão Pulmonar/fisiopatologia , Transplante de Pulmão/efeitos adversos , Masculino , NF-kappa B/antagonistas & inibidores , Perfusão , Ratos , Ratos Sprague-Dawley , Traumatismo por Reperfusão/imunologia , Traumatismo por Reperfusão/fisiopatologia , Doadores de Tecidos , Obtenção de Tecidos e Órgãos , Imunologia de Transplantes , Isquemia Quente/efeitos adversos
13.
Transplantation ; 100(7): 1465-73, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27331361

RESUMO

BACKGROUND: Donor lungs obtained after prolonged warm ischemia (WI) may be unsuitable for transplantation due to the risk of reperfusion injury, but could be reconditioned using ex-vivo lung perfusion (EVLP). Key processes of reperfusion injury include the formation of reactive oxygen species (ROS)/nitrogen species (RNS) and the activation of poly(adenosine diphosphate-ribose) polymerase (PARP). We explored whether rat lungs obtained after WI could be reconditioned during EVLP using the ROS/RNS scavenger Mn(III)-tetrakis (4-benzoic acid) porphyrin chloride (MnTBAP) or the PARP inhibitor 3-aminobenzamide (3-AB). METHODS: Rat lungs obtained after 3 hours cold ischemia (CI group, control), or 1 hour WI plus 2 hours CI (WI group) were placed in an EVLP circuit for normothermic perfusion for 3 hours. Lungs retrieved after WI were treated or not with 3-AB (1 mg/mL) or MnTBAP (0.3 mg/mL), added to the perfusate. Measurements included physiological variables (lung compliance, vascular resistance, oxygenation capacity), lung weight gain, levels of proteins, lactate dehydrogenase, protein carbonyl (marker of ROS), 3-nitrotyrosine (marker of RNS), poly(adenosine diphosphate-ribose) (PAR, marker of PARP activation) and IL-6, in the bronchoalveolar lavage or the lung tissue, and histology. RESULTS: In comparison to the CI group, the lungs from the WI group displayed higher protein carbonyls, 3-nitrotyrosine, PAR, lactate dehydrogenase and proteins in bronchoalveolar lavage, lung weight gain, perivascular edema, as well as reduced static compliance, but similar oxygenation. All these alterations were markedly attenuated by 3-AB and MnTBAP. CONCLUSIONS: After EVLP, lungs obtained after WI exhibit oxidative stress, PARP activation, and tissue injury, which are suppressed by pharmacological inhibitors of ROS/RNS and PARP.


Assuntos
Pulmão/patologia , Pulmão/cirurgia , Perfusão/métodos , Ácido Peroxinitroso/antagonistas & inibidores , Inibidores de Poli(ADP-Ribose) Polimerases/química , Condicionamento Pré-Transplante/métodos , Animais , Benzamidas/química , Isquemia Fria , Circulação Extracorpórea , Interleucina-6/metabolismo , Pulmão/efeitos dos fármacos , Masculino , Metaloporfirinas/química , Ácido Peroxinitroso/química , Poli(ADP-Ribose) Polimerases/química , Ratos , Ratos Sprague-Dawley , Espécies Reativas de Nitrogênio/metabolismo , Espécies Reativas de Oxigênio/metabolismo
14.
Innovations (Phila) ; 10(1): 68-70, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25621876

RESUMO

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.


Assuntos
Estenose da Valva Aórtica/cirurgia , Comunicação Interventricular/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Dispositivo para Oclusão Septal , Idoso de 80 Anos ou mais , Feminino , Humanos , Resultado do Tratamento
15.
Ann Thorac Surg ; 97(4): e111-3, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24694451

RESUMO

Immunoglobulin G4 (IgG4)-related fibroinflammatory systemic disease accounts for 7% of all noninfectious aneurysms of the thoracic aorta. A patient was admitted with a symptomatic ascending aortic aneurysm and thickened aortic wall (outer/inner diameter 55/45 mm), which was replaced. Probes revealed IgG4-related aortitis associated with a primary tuberculosis infection. Corticosteroid and antituberculosis therapies were used, and the patient's clinical evolution was favorable. The optimal treatment strategy of IgG4-related aortitis, a new entity, remains vague. Inner aortic diameter alone does not justify aortic replacement, but wall thickening may mimic intramural hematoma. In this particular case of IgG4-related aortitis, immunosuppressive treatment alone, as an alternative to a surgical procedure, may be debatable.


Assuntos
Aorta/cirurgia , Aortite/imunologia , Aortite/cirurgia , Imunoglobulina G , Feminino , Humanos , Pessoa de Meia-Idade
16.
Eur J Cardiothorac Surg ; 44(2): 370-4; discussion 374, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23386714

RESUMO

OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/terapia , Animais , Ponte Cardiopulmonar/métodos , Modelos Animais de Doenças , Ecocardiografia/métodos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Contração Miocárdica/fisiologia , Período Pós-Operatório , Desenho de Prótese , Suínos
17.
Eur J Cardiothorac Surg ; 43(5): 978-85, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22885336

RESUMO

OBJECTIVES: Transcatheter aortic valve replacement (TAVR) provides good results in selected high-risk patients. However, it is unclear whether this procedure carries advantages in extreme-risk profile patients with logistic EuroSCORE above 35%. METHODS: From January 2009 to July 2011, of a total number of 92 transcatheter aortic valve procedures performed, 40 'extreme-risk' patients underwent transapical TAVR (TA-TAVR) (EuroSCORE above 35%). Variables were analysed as risk factors for hospital and mid-term mortality, and a 2-year follow-up (FU) was obtained. RESULTS: The mean age was: 81 ± 10 years. Twelve patients (30%) had chronic pulmonary disease, 32 (80%) severe peripheral vascular disease, 14 (35%) previous cardiac surgery, 19 (48%) chronic renal failure (2 in dialysis), 7 (17%) previous stroke (1 with disabilities), 3 (7%) a porcelain aorta and 12 (30%) were urgent cases. Mean left ventricle ejection fraction (LVEF) was 49 ± 13%, and mean logistic EuroSCORE was 48 ± 11%. Forty stent-valves were successfully implanted with six Grade-1 and one Grade-2 paravalvular leakages (success rate: 100%). Hospital mortality was 20% (8 patients). Causes of death following the valve academic research consortium (VARC) definitions were: life-threatening haemorrhage (1), myocardial infarction (1), sudden death (1), multiorgan failure (2), stroke (1) and severe respiratory dysfunction (2). Major complications (VARC definitions) were: myocardial infarction for left coronary ostium occlusion (1), life-threatening bleeding (2), stroke (2) and acute kidney injury with dialysis (2). Predictors for hospital mortality were: conversion to sternotomy, life-threatening haemorrhage, postoperative dialysis and long intensive care unit (ICU) stay. Variables associated with hospital mortality were: conversion to sternotomy (P = 0.03), life-threatening bleeding (P = 0.02), acute kidney injury with dialysis (P = 0.03) and prolonged ICU stay (P = 0.02). Mean FU time was 24 months: actuarial survival estimates for all-cause mortality at 6 months, 1 year, 18 months and 2 years were 68, 57, 54 and 54%, respectively. Patients still alive at FU were in good clinical condition, New York Heart Association (NYHA) class 1-2 and were never rehospitalized for cardiac decompensation. CONCLUSIONS: TA-TAVR in extreme-risk patients carries a moderate risk of hospital mortality. Severe comorbidities and presence of residual paravalvular leakages affect the mid-term survival, whereas surviving patients have an acceptable quality of life without rehospitalizations for cardiac decompensation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Ann Thorac Surg ; 96(1): 247-52, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23684158

RESUMO

BACKGROUND: Sleeve lobectomy is a valid alternative to pneumonectomy for the treatment of centrally located operable non-small cell lung cancer (NSCLC), but concern has been evoked regarding a potentially increased risk of bronchial anastomosis complications after induction therapy. This study examined the impact of induction therapy on airway healing after sleeve lobectomy for NSCLC. METHODS: Bronchial anastomosis complications were recorded with respect to the induction regimen applied (neoadjuvant chemotherapy vs chemoradiotherapy) in a consecutive series of patients with sleeve lobectomy for NSCLC. RESULTS: Ninety-nine patients underwent sleeve resection, 28 of them after induction therapy. Twelve patients received chemotherapy alone, and 16 patients had radiochemotherapy. There were no significant differences in postoperative 90-day mortality (3.6% vs 2.8%) and morbidity (54% vs 49%) for patients with and without induction therapy. Bronchial anastomosis complications occurred in 3 patients (10.8%) with neoadjuvant therapy and in 2 (2.8%) without (p = 0.3). In the induction therapy group, two bronchial stenoses occurred after radiochemotherapy and one bronchopleural fistula after chemotherapy alone. In patients without induction therapy, one bronchial stenosis and one bronchopleural fistula were observed. All bronchial stenoses were successfully treated by dilatation, and both bronchopleural fistulas occurring after right lower lobectomy were successfully treated by reoperation and completion sleeve bilobectomy with preservation of the upper lobe. CONCLUSIONS: Sleeve lobectomy for NSCLC can be safely performed after induction chemotherapy and radiochemotherapy with mortality and incidence of airway complications similar to that observed in nonpretreated patients. The treatment of airway complications does not differ for patients with and without induction therapy.


Assuntos
Obstrução das Vias Respiratórias/terapia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Quimioterapia de Indução/métodos , Neoplasias Pulmonares/cirurgia , Pneumonectomia/efeitos adversos , Complicações Pós-Operatórias/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Obstrução das Vias Respiratórias/epidemiologia , Obstrução das Vias Respiratórias/etiologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Quimiorradioterapia Adjuvante/métodos , Feminino , Seguimentos , Humanos , Incidência , Neoplasias Pulmonares/diagnóstico , Masculino , Pessoa de Meia-Idade , Pneumonectomia/métodos , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Suíça/epidemiologia , Resultado do Tratamento
19.
Interact Cardiovasc Thorac Surg ; 14(3): 367-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22159241

RESUMO

Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien™ XT stent-valve implantation through the fibrotic thin akinetic apical wall.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Aneurisma Coronário/diagnóstico , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Doença Crônica , Aneurisma Coronário/complicações , Angiografia Coronária , Vasos Coronários , Diagnóstico Diferencial , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Tomografia Computadorizada por Raios X
20.
Thromb Res ; 128(5): 477-82, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21492909

RESUMO

INTRODUCTION: Although the pig is a standard model for the evaluation of various diseases in humans, including coagulopathy, it is not clear whether results in animals can be extrapolated to man. MATERIALS AND METHODS: In 75 anesthetized pigs, we assessed reagent-supported thrombelastometry (ExTEM®), platelet-blocked thrombelastometry (FibTEM®), and aprotinin thrombelastometry (ApTEM®). Results were compared to values from 13 anesthetized humans. RESULTS (MEDIAN, 95% CI): ExTEM®: While clot strength was comparable in pigs (66 mm, 65-67 mm) and in humans (64 mm, 60-68 mm; NS), clotting time in animals was longer (pigs 64 s, 62-66 s; humans 55 s, 49-71 s; P<0.05) and clot formation time shorter (pigs 52 s, 49-54 s; humans 83 s, 67-98 s, P<0.001). The clot lysis index at 30 minutes was lower in animals (96.9%, 95.1-97.3%) than in humans (99.5%, 98.6-99.9%; P<0.001). ApTEM® showed no hyperfibrinolysis in animals. Modification of the anesthesia protocol in animals resulted in significant ExTEM® changes. FibTEM®: Complete platelet inhibition yielded significantly higher platelet contribution to clot strength in pigs (79%, 76-81%) than in humans (73%, 71-77%; P<0.05), whereas fibrinogen contribution to clot strength was higher in humans (27%, 24-29%) than in animals (21%, 19-24%; P<0.05). CONCLUSIONS: Maximum clot firmness is comparable in human and porcine blood. However, clot lysis, platelet and fibrinogen contribution to clot strength, as well as initiation and propagation of clotting, are considerably different between pigs and humans. In addition, anesthesic drugs seem to influence thrombelastometry in animals. Accordingly, coagulation abnormalities in pigs subjected to diseases may not necessarily represent the coagulation profile in sick patients.


Assuntos
Coagulação Sanguínea , Tromboelastografia/métodos , Anestésicos/farmacologia , Animais , Testes de Coagulação Sanguínea/métodos , Plaquetas , Fibrinogênio , Fibrinólise , Humanos , Indicadores e Reagentes , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA