Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
2.
J Synchrotron Radiat ; 28(Pt 5): 1649-1661, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34475312

RESUMO

Here we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.


Assuntos
Cristalografia por Raios X/métodos , Substâncias Macromoleculares/química , Robótica/métodos , Desenho de Equipamento , Espalhamento a Baixo Ângulo , Software , Síncrotrons , Raios X
3.
Electrophoresis ; 42(6): 708-718, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33284492

RESUMO

Human immunodeficiency virus-acquired immunodeficiency syndrome continues to be a major global public health issue, having claimed almost 33 million lives to date. Due to the high cost of antiretroviral treatment, access to these drugs remains difficult for vulnerable populations, such as migrants and people living in prisons, who often do not have health insurance. These factors lead to poorer health outcomes and higher transmission rates. The personal importation scheme for unapproved generics from foreign countries is one option to access affordable human immunodeficiency virus treatment. However, the risk of importing falsified medicine remains high, and the quality control of unapproved drugs is lacking. In this context, three CE methods for the analysis of nine antiviral drugs found in commercial pharmaceutical formulations were evaluated. The selected compounds were emtricitabine, tenofovir disoproxil, tenofovir alafenamide, rilpivirine, efavirenz, raltegravir, dolutegravir, abacavir, and lamivudine. The developed methods were successfully applied to determine the active pharmaceutical ingredients of commercial formulations and unapproved generics. The quality control of unapproved generics by CE is an attractive approach due to its good standard of quality, low cost, ecofriendliness, and ease of implementation.


Assuntos
Eletroforese Capilar , Infecções por HIV , HIV-1 , Antirretrovirais/uso terapêutico , Infecções por HIV/tratamento farmacológico , Humanos , Preparações Farmacêuticas , Suíça
4.
Electrophoresis ; 39(20): 2512-2520, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29427392

RESUMO

Two capillary electrophoresis (CE) methods were developed for the analysis of 16 antineoplastic drugs contained in injectable pharmaceutical formulations. A capillary zone electrophoresis (CZE) method coupled to UV was developed with a background electrolyte (BGE) made of a 100 mM phosphate buffer at pH 2.5 containing 50% v/v of acetonitrile and dynamic coating of capillaries with Ceofix®. This method allowed the analysis of doxorubicin, epirubicin, idarubicin, daunorubicin, irinotecan, topotecan, vincristine, vindesine, vinblastine, and vinorelbine in less than 8 min. A micellar electrokinetic chromatography (MEKC) method coupled to UV was also developed for the determination of methotrexate, pemetrexed, etoposide, etoposide phosphate, fludarabine phosphate, and 5-fluorouracil. A run time of 16 min was obtained with a BGE made of 50 mM borate buffer at pH 9.2 with 80 mM of sodium dodecyl sulfate (SDS) and 20% v/v of acetonitrile. For both methods, the applied voltage was 30 kV and the sample injection was performed in the hydrodynamic mode. All analyses were carried out in fused silica capillaries with an internal diameter of 50 µm and a total length of 64.5 cm. Both methods were validated and trueness values between 99.4 and 101.3% were obtained with repeatability and intermediate precision values of 0.5-1.8% for all drugs. These methods were found appropriate for controlling injectable pharmaceutical formulations containing antineoplastic drugs and successfully applied in quality control.


Assuntos
Antineoplásicos/análise , Eletroforese Capilar/métodos , Espectrofotometria Ultravioleta/métodos , Modelos Lineares , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Analyst ; 142(13): 2273-2321, 2017 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-28560370

RESUMO

The number of patients suffering from cancer is constantly increasing and, consequently, the number of different chemotherapy treatments administered is increasing. Given the high reactivity and toxicity of antineoplastic drugs, analytical methods are required in all pharmaceutical fields, from drug development to their elimination in wastewater; including formulation quality control, environment and human exposure and therapeutic drug monitoring. The aim of this paper is to provide an overview of the analytical methods available for the determination of antineoplastic drugs in different matrices such as pharmaceutical formulations, biological and environmental samples. The applicability and performance of the reported methods will be critically discussed, with focus on the most commonly used antineoplastic drugs. Only conventional compounds and small molecules for targeted therapy will be considered in the present review.


Assuntos
Antineoplásicos/farmacologia , Neoplasias/tratamento farmacológico , Humanos , Controle de Qualidade
6.
J Oncol Pharm Pract ; : 1078155217732629, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28975863

RESUMO

Purpose Ganciclovir is increasingly provided by hospital pharmacy production unit in a ready-to-use form, in order to improve the safety of healthcare workers and the efficiency of the organisation. The objective of this study was to develop a stability-indicating method to assay ganciclovir and determine the stability of ganciclovir in syringes (5 mg/mL) and infusion bags (0.25 and 5 mg/mL) at two different temperatures. Method Ganciclovir solutions (0.25 mg/mL and 5 mg/mL) in 0.9% sodium chloride were prepared in 50 mL polypropylene syringes or 100 mL polypropylene infusion bags and stored at 2-8℃ and 23-27℃. The chemical stability was measured using a stability-indicating Ultra High Performance Liquid Chromatography coupled to mass spectrometry method. Physical stability was assessed by visual inspection. Results No significant loss of ganciclovir under any of the tested conditions was observed in this study. All solutions remained clear through the study period. Conclusion All tested formulations remained stable for at least 185 days independently of container type, temperature or concentration studied.

7.
J Synchrotron Radiat ; 22(6): 1540-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524320

RESUMO

MASSIF-1 (ID30A-1) is an ESRF undulator beamline operating at a fixed wavelength of 0.969 Å (12.8 keV) that is dedicated to the completely automatic characterization of and data collection from crystals of biological macromolecules. The first of the ESRF Upgrade MASSIF beamlines to be commissioned, it has been open since September 2014, providing a unique automated data collection service to academic and industrial users. Here, the beamline characteristics and details of the new service are outlined.


Assuntos
Cristalização/instrumentação , Cristalografia por Raios X/instrumentação , Armazenamento e Recuperação da Informação/métodos , Complexos Multiproteicos/química , Complexos Multiproteicos/ultraestrutura , Síncrotrons/instrumentação , Algoritmos , Biopolímeros/química , Desenho de Equipamento , Análise de Falha de Equipamento , Robótica/instrumentação
8.
Eur J Hosp Pharm ; 28(2): 94-99, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33608437

RESUMO

PURPOSE: Optimise a wipe sampling procedure to evaluate the surface contamination for 23 antineoplastic drugs used in the hospital pharmacy. METHODS: The influence of various parameters (ie, sampling device, sampling solution, desorption modes) was evaluated using a validated liquid chromatography-mass spectrometry (LC-MS/MS) method able to quantify 23 antineoplastic drugs widely used in the hospital pharmacy: 5-fluorouracil, busulfan, cyclophosphamide, cytarabine, dacarbazine, daunorubicin, docetaxel, doxorubicin, epirubicin, etoposide, etoposide phosphate, fludarabine phosphate, ganciclovir, gemcitabine, idarubicin, ifosfamide, irinotecan, methotrexate, paclitaxel, pemetrexed, raltitrexed, topotecan and vincristine. Best conditions were tested with real samples from a hospital pharmacy chemotherapy compounding unit. RESULTS: Polyester swabs (TX714 and TX716) gave satisfactory results for the desorption step for all compounds with mean recoveries of 90% and 95%, respectively. For the wiping step, higher recoveries were obtained using TX716 and isopropanol 75% as wiping solution. As anticipated, most intense contaminations were found close to the chemotherapy production site, on surfaces the most frequently in contact with operators' hands. CONCLUSION: Wipe sampling method was successfully developed and applied to real samples to determine surface contamination with 23 antineoplastic agents in trace amounts.


Assuntos
Antineoplásicos , Serviço de Farmácia Hospitalar , Antineoplásicos/análise , Cromatografia Líquida , Ifosfamida/análise , Espectrometria de Massas em Tandem/métodos
9.
JCO Glob Oncol ; 7: 1480-1489, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34648387

RESUMO

PURPOSE: Chemotherapies are considered high-risk drugs for patient and staff safety. Considering the rising burden of cancer and the increasing use of chemotherapy drugs in low- and middle-income countries (LMICs), promoting continuous improvements in the safety and quality of practices in these settings is essential. This paper describes the development and proof of concept of a toolkit to audit chemotherapy handling practices in the health care facilities of LMICs. METHODS: A steering committee defined the audit method and the toolkit content. Several checklists were developed to facilitate the audit and data collection. Items included in checklists were derived from key reference works on safe handling. Different tools were validated using Delphi surveys and expert reviews. Audits of pilot sites were performed to test the toolkit's applicability and relevance. RESULTS: The toolkit contains a 134-item global assessment tool for the different processes at each step of the medication pathway and three step-specific observation checklists to assess different health workers' practices during the prescription, preparation, and administration of chemotherapies. The toolkit also proposes using a surface-wipe sampling method to measure any cytotoxic contamination of the immediate environment. The toolkit was tested in three teaching hospitals in Africa. CONCLUSION: The toolkit developed was successfully implemented in a variety of LMIC settings, providing a comprehensive evaluation of the quality and safety of the chemotherapy drug handling practices in participating health care facilities. This toolkit can help facilities in LMICs to implement a new approach to continuously improving the quality and safety of their practices and ultimately ensure patient and staff safety.


Assuntos
Antineoplásicos , Preparações Farmacêuticas , África , Países em Desenvolvimento , Pessoal de Saúde , Humanos
10.
PLoS One ; 15(6): e0235131, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32569333

RESUMO

BACKGROUND: Residual contamination by intravenous conventional antineoplastic drugs (ICAD) is still a daily issue in hospital facilities. This study aimed to compare the efficiency (EffQ) of 4 different solutions to remove 23 widely used ICADs from surfaces. METHOD AND FINDINGS: A solution containing 23 ICADs (4 alkylating agents, 8 antimetabolites, 2 topo-I inhibitors, 6 topo-II inhibitors and 3 spindle poisons) was spread over 100 cm2 stainless steel. After drying, decontamination was carried out using 10×10 cm wipes moistened with 300 µL of one of the following solutions: 70% isopropanol (S1); ethanol-hydrogen peroxide 91.6-50.0 mg/g (S2); 10-2 M sodium dodecyl sulphate/isopropanol 80/20 (S3) or 0.5% sodium hypochlorite (S4). Six tests were performed for each decontamination solution. Two modalities were tested: a single wipe motion from top to bottom or vigorous wiping (n = 6 for each modality). Residual contamination was measured with a validated liquid chromatography with tandem mass spectrometry detection method. Solution efficiency (in %) was computed as follows: EffQ = 1-(quantity after decontamination/quantity before decontamination), as median (min-max) for the 23 ICADs. The overall decontamination efficiency (EffQ) of the 4 solutions was compared by a Kruskall-Wallis test. Decontamination modalities were compared for each solution and per ICAD with a Mann-Whitney test (p<0.05). EffQ were significantly different from one solution to the next for single wipe motion decontamination: 79.9% (69.3-100), 86.5% (13.0-100), 85.4% (56.5-100) and 100% (52.9-100) for S1, S2, S3 and S4 (p<0.0001), respectively. Differences were also significant for vigorous decontamination: EffQ of 84.3% (66.0-100), 92.3% (68.7-100), 99.6% (84.8-100) and 100% (82.9-100) for S1, S2, S3 and S4, respectively (p<0.0001). Generally, vigorous decontamination increased EffQ for all tested solutions and more significantly for the surfactant. CONCLUSION: Decontamination efficiency depended on the solution used but also on the application modality. An SDS admixture seems to be a good alternative to sodium hypochlorite, notably after vigorous chemical decontamination with no hazard either to materials or workers.


Assuntos
Antineoplásicos/isolamento & purificação , Descontaminação , Contaminação de Medicamentos , Soluções , Aço Inoxidável , Propriedades de Superfície
11.
J Pharm Biomed Anal ; 172: 139-148, 2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31035095

RESUMO

The validation and uncertainty assessment of the analytical method developed for the simultaneous determination of 25 anticancer drugs commonly handled in hospital pharmacy was reported. Selected compounds were 5-fluorouracil, cytarabine, fludarabine phosphate, ganciclovir, gemcitabine, dacarbazine, methotrexate, pemetrexed, busulfan, raltitrexed, etoposide phosphate, topotecan, ifosfamide, cyclophosphamide, irinotecan, doxorubicin, epirubicin, daunorubicin, idarubicin, vincristine, vinblastine, vinorelbine, docetaxel and paclitaxel. Accuracy and uncertainty profiles were obtained for all compounds. Quantitative performances were satisfactory in term of specificity, sensitivity, precision and accuracy. Repeatability (1.9-25.4%) and intermediate precision (2.7-29%) were determined for all target compounds. Lower limits of quantification between 1 and 25 ng/mL were obtained. Uncertainty associated to measurement of routine samples was evaluated. The multi-targeted method was specific and reliable and was successfully applied to wipe samples from hospital pharmacy chemotherapy compounding unit and to the determination of outside contamination of vials from pharmaceutical manufacturers.


Assuntos
Antineoplásicos/análise , Poluentes Ambientais/análise , Substâncias Perigosas/análise , Cromatografia Líquida de Alta Pressão , Descontaminação , Composição de Medicamentos/normas , Serviço de Farmácia Hospitalar/normas , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem , Incerteza
12.
J Pharm Biomed Anal ; 164: 395-401, 2019 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-30439666

RESUMO

This study reports the use of retention modeling software for the successful method development of 24 injectable antineoplastic agents. Firstly, a generic screening of several stationary and mobile phases (using various organic modifiers and pH) was achieved. Then, an optimization procedure of mobile phase temperature, gradient profile and mobile phase binary composition was conducted through only 28 real experiments using retention modeling software for data treatment. Finally, the optimized separation was achieved with a mobile phase consisting in 10 mM acetic acid at pH 5.1 (A) and acetonitrile (B). A Waters CORTECS® T3 column (100 × 2.1 mm, 1.6 µm) operated at 25 °C with a gradient time of 17.5 min (0-51%B) at a flow rate of 0.4 mL/min was used. The prediction offered by the retention model was found to be highly reliable, with an average error lower than 1%. A robustness testing step was also assessed from a virtual experimental design. Success rate and regression coefficient were evaluated without the need to perform any real experiment. The developed LC-MS method was successfully applied to the analysis of pharmaceutical formulations and wiping samples from working environment.


Assuntos
Antineoplásicos/análise , Segurança Química/métodos , Modelos Químicos , Serviço de Farmácia Hospitalar/métodos , Gestão da Segurança/métodos , Antineoplásicos/toxicidade , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Simulação por Computador , Composição de Medicamentos , Software , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos , Temperatura
13.
Am J Health Syst Pharm ; 74(22): 1887-1894, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-29118046

RESUMO

PURPOSE: The stability of busulfan solution in 0.9% sodium chloride and stored in polypropylene syringes or infusion bags was evaluated. METHODS: Busulfan solutions (0.54 mg/mL) were prepared and transferred to 50-mL polypropylene syringes and 100- and 500-mL polypropylene infusion bags and stored at 2-8 and 23-27 °C. Chemical stability was measured using a stability-indicating, ultrahigh performance liquid chromatography coupled to mass spectrometry method. The stability of busulfan was assessed by measuring the percentage of the initial concentration remaining at the end of each time point of analysis. The initial busulfan concentration was defined as 100%. Stability was defined as retention of at least 90% of the initial busulfan concentration. A visual inspection of the samples for particulate matter, clarity, and color without instrumentation of magnification was conducted at each time point of analysis. RESULTS: The visual inspection demonstrated no influence of the storage container when busulfan infusions diluted in 0.9% sodium chloride injection were stored at 23-27 °C. No color change or precipitate was observed at this temperature; however, a rapid decrease of the busulfan content in all containers stored at room temperature was observed. Busulfan in syringes was chemically stable for 12 hours, while busulfan in infusion bags (100 and 500 mL) was stable only for 3 hours at 23-27 °C. CONCLUSION: Busulfan 0.54-mg/mL solution in 0.9% sodium chloride injection was physically and chemically stable for 30 hours when stored in 50-mL polypropylene syringes at 2-8 °C and protected from light.


Assuntos
Antineoplásicos Alquilantes/química , Bussulfano/química , Soluções Farmacêuticas/química , Antineoplásicos Alquilantes/análise , Bussulfano/análise , Embalagem de Medicamentos , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Seringas
14.
Acta Crystallogr D Struct Biol ; 72(Pt 8): 966-75, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27487827

RESUMO

Automation of the mounting of cryocooled samples is now a feature of the majority of beamlines dedicated to macromolecular crystallography (MX). Robotic sample changers have been developed over many years, with the latest designs increasing capacity, reliability and speed. Here, the development of a new sample changer deployed at the ESRF beamline MASSIF-1 (ID30A-1), based on an industrial six-axis robot, is described. The device, named RoboDiff, includes a high-capacity dewar, acts as both a sample changer and a high-accuracy goniometer, and has been designed for completely unattended sample mounting and diffraction data collection. This aim has been achieved using a high level of diagnostics at all steps of the process from mounting and characterization to data collection. The RoboDiff has been in service on the fully automated endstation MASSIF-1 at the ESRF since September 2014 and, at the time of writing, has processed more than 20 000 samples completely automatically.


Assuntos
Cristalografia por Raios X/instrumentação , Proteínas/química , Animais , Bacillus/química , Proteínas de Bactérias/química , Bovinos , Cristalografia por Raios X/economia , Cristalografia por Raios X/métodos , Desenho de Equipamento , Robótica , Software , Termolisina/química , Tripsina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA