Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artif Organs ; 48(7): 753-762, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38404240

RESUMO

BACKGROUND: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out in 21 patients. All patients underwent six dialysis sessions with the same routine dialysis parameters; only the dialyzer and/or the dialysis modality varied: FX80 in HD, FDY 180 in HD, Clearum HS17 in HDF, Elisio 19H in HDF, Vitapes 180 in HDF, and FX80 in post-dilution HDF. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, κFLC, prolactin, α1-microglobulin, α1-acid glycoprotein, λFLC, and albumin were compared intraindividually. Dialysate albumin loss was also measured. RESULTS: Both membranes FDY and FX80 are high-flux dialyzers and are applied here in high-flux HD. The average RR of ß2-microglobulin was slightly lower in the two HD treatments than in the HDF treatments. Comparison of dialysis treatments revealed that the PEPA FDY dialyzer in the HD modality was more effective than the FX80 dialyzer in high-flux HD and was as effective as post-dilution HDF, especially in terms of myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs. The FDY treatments obtained similar albumin RR in blood and slightly higher dialysate albumin loss, although the values were clinically acceptable. CONCLUSIONS: The most recently developed PEPA dialyzers in the HD modality were as effective as all treatments in the HDF modality and were clearly superior to high-flux helixone HD treatment. These results confirm that this dialyzer should be categorized within the medium cut-off (MCO) membrane classification.


Assuntos
Membranas Artificiais , Poliésteres , Diálise Renal , Humanos , Masculino , Diálise Renal/instrumentação , Diálise Renal/métodos , Pessoa de Meia-Idade , Feminino , Idoso , Estudos Prospectivos , Poliésteres/química , Ligas/química , Idoso de 80 Anos ou mais , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos , Adulto , Polímeros/química
2.
Am J Nephrol ; 54(7-8): 291-298, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37311444

RESUMO

INTRODUCTION: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients' salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. METHODS: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients' usual Na diet and again after another week with more restricted Na intake. RESULTS: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. CONCLUSIONS: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.


Assuntos
Cloreto de Sódio na Dieta , Sódio , Humanos , Estudos Prospectivos , Diálise Renal/métodos , Dieta Hipossódica , Pressão Sanguínea , Aumento de Peso
3.
Blood Purif ; 52(1): 68-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35551384

RESUMO

INTRODUCTION: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. RESULTS: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. CONCLUSIONS: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.


Assuntos
Hemodiafiltração , Diálise Renal , Humanos , Estudos Prospectivos , Hemodiafiltração/efeitos adversos , Albuminas , Soluções para Diálise
4.
Blood Purif ; 51(1): 38-46, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33789268

RESUMO

INTRODUCTION: Haemodialysis (HD) allow depuration of uraemic toxins by diffusion, convection, and adsorption. Online haemodiafiltration (HDF) treatments add high convection to enhance removal. There are no prior studies on the relationship between convection and adsorption in HD membranes. The possible benefits conferred by intrinsic adsorption on protein-bound uraemic toxins (PBUTs) removal are unknown. METHODS: Twenty-two patients underwent their second 3-days per week HD sessions with randomly selected haemodialysers (polysulfone, polymethylmethacrylate, cellulose triacetate, and polyamide copolymer) in high-flux HD and HDF. Blood samples were taken at the beginning and at the end of the treatment to assess the reduction ratio (RR) in a wide range of molecular weight uraemic toxins. A mid-range removal score (GRS) was also calculated. An elution protocol was implemented to quantify the amount of adsorbed mass (Mads) for each molecule in every dialyser. RESULTS: All synthetic membranes achieved higher RR for all toxins when used in HDF, specially the polysulfone haemodialyser, resulting in a GRS = 0.66 ± 0.06 (p < 0.001 vs. cellulose triacetate and polyamide membranes). Adsorption was slightly enhanced by convection for all membranes. The polymethylmethacrylate membrane showed expected substantial adsorption of ß2-microglobulin (MadsHDF = 3.5 ± 2.1 mg vs. MadsHD = 2.1 ± 0.9 mg, p = 0.511), whereas total protein adsorption was pronounced in the cellulose triacetate membrane (MadsHDF = 427.2 ± 207.9 mg vs. MadsHD = 274.7 ± 138.3 mg, p = 0.586) without enhanced PBUT removal. DISCUSSION/CONCLUSION: Convection improves removal and slightly increases adsorption. Adsorbed proteins do not lead to enhanced PBUTs depuration and limit membrane efficiency due to fouling. Selection of the correct membrane for convective therapies is mandatory to optimize removal efficiency.


Assuntos
Hemodiafiltração/instrumentação , Membranas Artificiais , Toxinas Urêmicas/isolamento & purificação , Adsorção , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Uremia/terapia , Toxinas Urêmicas/sangue
5.
J Clean Prod ; 380: 135057, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36348962

RESUMO

As the Covid-19 pandemic brought most in-person activities to a halt, radical and visible changes were imposed in all social interactions, including teaching and academic activity in general. This challenging setting tested the education system's capacity to successfully address the Sustainable Development Goals. The success of education for sustainable development (ESD) requires training in the specific skills needed to face the highly emotionally demanding post-pandemic context. In this line, this study focuses on university students' capability to understand and manage emotions, an issue considered to be a key factor in ESD. The aim of this study is to show how students' emotional intelligence influenced their resilience, with repercussions on their engagement and subsequent academic performance. The research model was tested through a questionnaire addressed to 340 students from three different universities during the full lockdown of March-May 2020 as a result of the pandemic. Results show that emotional intelligence was positively related to resilience, which in turn was related to engagement, and consequently, resulted in better academic performance. This finding should spark interest in developing emotional intelligence in education, not only because it produces healthy citizens in the long term, but also because of its short-term positive impacts in the classroom, particularly in such adverse situations as those described here. This study provides a model that links classic variables on educational and positive psychology research with ESD in times of COVID-19.

6.
Artif Organs ; 45(9): E317-E323, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33908062

RESUMO

Toray has created a new generation of dialyzers, the polysulphone (TS) UL series, and polymethylmethacrylate (PMMA) NF-U series, which offer enhanced efficacy over the previous TS-S series and NF-H series. The aim of this study was to evaluate the safety and efficacy of these dialyzer series versus contrasted expanded hemodialysis (HDx) and postdilution hemodiafiltration (HDF). We conducted a prospective study in 12 patients. Each patient underwent six dialysis sessions: FX80 Cordiax in HD, Toraysulfone TS-1.8 UL in HD, Theranova 400 in HDx, polymethylmethacrylate (PMMA) NF-2.1 U in HDF, Toraysulfone TS-2.1 UL in HDF, and FX80 Cordiax in HDF. The removal ratios (RRs) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. The RRs for ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, and α1 -acid glycoprotein were higher with the TS-2.1 UL and FX80 Cordiax dialyzers in HDF than those obtained with HD treatments and NF-2.1 U in HDF. The ß2 -microglobulin, myoglobin, and prolactin RRs were also higher with HDx than those obtained with HD treatments. The myoglobin and prolactin RRs were higher with TS-1.8 UL in HD than those obtained with helixone dialyzers in HD. Dialysate albumin loss was less than 3 g in all situations except in TS-2.1 UL in HDF. The highest global removal score values were obtained with the TS-2.1 UL and helixone dialyzers in HDF. Significant differences were found between all study situations. In conclusion, the new generation dialyzers, Toraysulfone TS Series UL and PMMA NF-U series, show excellent behaviour and tolerance in HD and HDF, representing an upgrade versus their predecessor series. The higher permeability of the TS UL series has been proven with higher efficiency in HD and maximum performance in HDF. The new PMMA NF-U series allows the use of HDF with good efficiency and complete safety.


Assuntos
Hemodiafiltração/instrumentação , Nefropatias/terapia , Membranas Artificiais , Polímeros/química , Polimetil Metacrilato/química , Sulfonas/química , Idoso , Biomarcadores/sangue , Feminino , Humanos , Nefropatias/sangue , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
Artif Organs ; 45(10): 1195-1201, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33978975

RESUMO

The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.


Assuntos
Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Idoso , Idoso de 80 Anos ou mais , alfa-Globulinas/análise , Creatinina/sangue , Feminino , Hemodiafiltração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/sangue , Orosomucoide/análise , Segurança do Paciente , Prolactina/sangue , Estudos Prospectivos , Diálise Renal/métodos , Resultado do Tratamento , Ureia/sangue , Microglobulina beta-2/sangue
8.
Artif Organs ; 44(10): E448-E458, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32279348

RESUMO

The aim of the study was to compare expanded hemodialysis (HDx) with hemodiafiltration (HDF) at different infusion flows to identify the main determinants, namely blood flow (Qb), replacement volume, infusion flow (Qi), ultrafiltration flow (Quf ), filtration fraction (FF), and the point at which the effectiveness of HDF equals or exceeds that of HDx. We conducted a prospective, single-center study in 12 patients. Each patient underwent 12 dialysis sessions: six sessions with Qb 350 and six with Qb 400 mL/min; with each Qb, one session was with HDx and five sessions were with FX80 (one in HD, and four with Qi 50, 75, 90/100 mL/min or autosubstitution in postdilution HDF). The reduction ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually and the global removal score (GRS) was calculated. The mean replacement volume with Qb 350 mL/min was 13.77 ± 0.92 L with Qi 50 mL/min, 20.75 ± 1.17 L with Qi 75, 23.83 ± 1.92 L with Qi 90, and 27.51 ± 2.77 L with autosubstitution. Similar results were obtained with Qb 400 mL/min, and the results were only slightly higher with Qi 100 mL/min or in autosubstitution. The GRS was positively correlated with replacement volume with Qb 350 (R2  = 0.583) and with Qb 400 (R2  = 0.584); with Quf with Qb 350 (R2  = 0.556) and with Qb 400 (R2  = 0.604); and also with FF with Qb 350 (R2  = 0.556) and with Qb 400 mL/min (R2  = 0.603). The minimum convective volume in HDF from which it is possible to overcome the efficacy of HDx was 19.2 L with Qb 350 and 17.6 L with Qb 400 mL/min. The cut-off point of Quf at which HDF exceeded the effectiveness of HDx was 80.6 mL/min with Qb 350 and 74.1 mL/min with Qb 400 mL/min. The cut-off point at which FF in HDF exceeded the effectiveness of the HDx was 23.0% with Qb 350 and 18.6% with Qb 400 mL/min. In conclusion, this study confirms the superiority of postdilution HDF over HDx when replacement volume, convective volume, Quf , or FF exceeds certain values. Increasing the Qb in postdilution HDF manages to increase the convective dose and more easily overcome the HDx.


Assuntos
Hemodiafiltração/estatística & dados numéricos , Falência Renal Crônica/terapia , Diálise Renal/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/urina , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
9.
Blood Purif ; 49(4): 400-408, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31865336

RESUMO

BACKGROUND: The biocompatibility of dialysis membranes is a determining factor in avoiding chronic microinflammation in patients under haemodialysis. Lower biocompatibility has been related to increased inflammatory status, which is known to be associated with cardiovascular events. Classically, cellulose membranes have been considered bioincompatible. A new-generation of asymmetric cellulose triacetate (CTA) membranes allows the performance of high convective transport techniques, but there have been no studies of their biocompatibility. The aim of the present study was to analyze and compare the biocompatibility characteristics of 4 membranes, including CTA, in online hemodiafiltration (OL-HDF) patients. METHODS: We included 15 patients in -OL-HDF. After a 2-week washout period with helixone membrane, each patient was treated with the 4 membranes (polyamide, polynephron, helixone and CTA) for 4 weeks in a randomized order. The other dialysis parameters were kept stable throughout the study. We studied changes in markers of the activation of the complement system, monocytes, platelets, and adhesion molecules with the 4 membranes, as well as inflammatory parameters. RESULTS: Biocompatibility was similar among the membranes. There were no sustained differences in complement activation, measured by C3a and C5a levels, or in platelet activation, determined by levels of P-selectin and platelet-derived microparticles (CD41a+). No differences were observed in activated monocyte levels (CD14+/CD16+) or in plasma levels of interleukin (IL)-1, IL-6, IL-10 or high-sensitivity C-reactive protein, although tumour necrosis factor-α levels decreased when the patients were dialyzed with CTA. No significant differences were found in markers of endothelial damage, assessed by levels of plasminogen activator inhibitor-1 and adhesion molecules (intercellular adhesion molecule-1 and vascular cell adhesion molecule-1). CONCLUSION: The 4 membranes evaluated in this study in stable patients on OL-HDF, including the new-generation CTA, show similar biocompatibility with the methods applied.


Assuntos
Materiais Biocompatíveis/química , Hemodiafiltração/instrumentação , Teste de Materiais , Membranas Artificiais , Adulto , Idoso , Idoso de 80 Anos ou mais , Materiais Biocompatíveis/efeitos adversos , Celulose/efeitos adversos , Celulose/análogos & derivados , Celulose/química , Ativação do Complemento , Feminino , Humanos , Interleucinas/sangue , Masculino , Pessoa de Meia-Idade , Ativação Plaquetária
10.
Br J Nutr ; 121(1): 55-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30360768

RESUMO

The polyphenolic extract (PE) from extra virgin olive oil (EVOO) has been shown to possess important anti-inflammatory and joint protective properties in murine models of rheumatoid arthritis (RA). This study was designed to evaluate the effects of PE on IL-1ß-activated human synovial fibroblasts SW982 cell line. PE from EVOO treatment inhibited IL-1ß-induced matrix metalloproteases (P<0·001), TNF-α and IL-6 production (P<0·001). Similarly, IL-1ß-induced cyclo-oxygenase-2 and microsomal PGE synthase-1 up-regulations were down-regulated by PE (P<0·001). Moreover, IL-1ß-induced mitogen-activated protein kinase (MAPK) phosphorylation and NF-κB activation were ameliorated by PE (P<0·001). These results suggest that PE from EVOO reduces the production of proinflammatory mediators in human synovial fibroblasts; particularly, these protective effects could be related to the inhibition of MAPK and NF-κB signalling pathways. Taken together, PE from EVOO probably could provide an attractive complement in management of diseases associated with over-activation of synovial fibroblasts, such as RA.


Assuntos
Inflamação/tratamento farmacológico , Interleucina-1beta/farmacologia , Azeite de Oliva/química , Polifenóis/farmacologia , Membrana Sinovial/efeitos dos fármacos , Anti-Inflamatórios , Artrite Reumatoide/tratamento farmacológico , Linhagem Celular , Ciclo-Oxigenase 2/genética , Regulação para Baixo/efeitos dos fármacos , Fibroblastos/efeitos dos fármacos , Humanos , Inflamação/prevenção & controle , Interleucina-6/antagonistas & inibidores , Inibidores de Metaloproteinases de Matriz/farmacologia , Metaloproteinases da Matriz , Proteínas Quinases Ativadas por Mitógeno/metabolismo , NF-kappa B/metabolismo , Extratos Vegetais/farmacologia , Polifenóis/análise , Polifenóis/isolamento & purificação , Prostaglandina-E Sintases/genética , Transdução de Sinais/efeitos dos fármacos , Membrana Sinovial/citologia , Sinovite/prevenção & controle , Fator de Necrose Tumoral alfa/antagonistas & inibidores
11.
Artif Organs ; 43(10): 1014-1021, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31038748

RESUMO

Most high-flux dialyzers can be used in both hemodialysis (HD) and online hemodiafiltration (OL-HDF). However, some of these dialyzers have higher permeability and should not be prescribed for OL-HDF to avoid high albumin losses. The aim of this study was to compare the safety and efficacy of a currently used dialyzer in HD and OL-HDF with those of several other high permeability dialyzers which should only be used in HD. A prospective, single-center study was carried out in 21 patients. Each patient underwent 5 dialysis sessions with routine dialysis parameters: 2 sessions with Helixone (HD and postdilution OL-HDF) and 1 session each with steam sterilized polyphenylene, polymethylmethacrylate (PMMA), and medium cut-off (MCO) dialyzers in HD treatment. The removal ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. A proportional part of the dialysate was collected to quantify the loss of various solutes, including albumin. Urea and creatinine RRs with the Helixone-HDF and MCO dialyzers were higher than with the other 3 dialyzers in HD. The ß2 -microglobulin, myoglobin and prolactin RRs with Helixone-HDF treatment were significantly higher than those obtained with all 4 dialyzers in HD treatment. The ß2 -microglobulin value obtained with the MCO dialyzer was also higher than that obtained with the other 3 dialyzers in HD treatment. The myoglobin RR with MCO was higher than those obtained with Helixone and PMMA in HD treatment. The prolactin RR with Helixone-HD was significantly lower than those obtained in the other 4 study sessions. The α1 -microglobulin and α1 - acid glycoprotein RRs with Helixone-HDF were significantly higher than those obtained with Helixone and PMMA in HD treatment. The albumin loss varied from 0.54 g with Helixone-HD to 3.3 g with polyphenylene. The global removal score values ((UreaRR + ß2 -microglobulinRR + myoglobinRR + prolactinRR + α1 -microglobulinRR + α1 -acid glycoproteinRR - albuminRR )/6) were 43.7% with Helixone-HD, 47.7% with PMMA, 54% with polyphenylene, 54.8% with MCO and 59.6% with Helixone-HDF, with significant differences. In conclusion, this study confirms the superiority of OL-HDF over HD with the high-flux dialyzers that allow both treatments. Although new dialyzers with high permeability can only be used in HD, they are in an intermediate position and some are very close to OL-HDF.


Assuntos
Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Idoso , alfa-Globulinas/isolamento & purificação , Soluções para Diálise/uso terapêutico , Feminino , Hemodiafiltração/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/isolamento & purificação , Permeabilidade , Prolactina/isolamento & purificação , Estudos Prospectivos , Diálise Renal/efeitos adversos , Diálise Renal/instrumentação , Albumina Sérica/isolamento & purificação , Ureia/isolamento & purificação , Microglobulina beta-2/isolamento & purificação
12.
Blood Purif ; 48(2): 167-174, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30943486

RESUMO

BACKGROUND: A novel class of membranes, medium cut-off (MCO) membranes, has recently been designed to achieve interesting removal capacities for middle and large middle molecules in hemodialysis (HD) treatments. The few studies published to date have reported contradictory results regarding middle-sized molecules when comparing MCO dialyzers versus dialyzers used in online hemodiafiltration (OL-HDF). METHODS: A prospective, single-center study was carried out in 22 patients. Each patient underwent 9 dialysis sessions with routine dialysis parameters, one with an MCO dialyzer in HD and the other 8 with different dialyzers in OL-HDF. The removal ratio (RR) of urea, creatinine, ß2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, and albumin was intraindividually compared. Albumin loss in dialysate was measured. We propose a global removal score ([ureaRR + ß2-microglobulinRR + myoglobinRR + prolactinRR + α1-microglobulinRR + α1-acid glycoproteinRR]/6 - albuminRR) as a new tool for measuring dialyzer effectiveness. RESULTS: No significant differences in the RRs of small and middle molecular range molecules were observed between the MCO vs. OL-HDF dialyzers (range 60-80%). Lower RRs were found for α1-microglobulin and α1-acid glycoprotein without significant differences. The albumin RR was < 11% and dialysate albumin loss was < 3.5 g in all situations without significant differences. The global removal score was 54.9 ± 4.8% with the MCO dialyzer without significant differences. CONCLUSIONS: Removal of a wide range of molecular weights, calculated with the proposed global removal score, was almost equal with the MCO dialyzer in HD treatment compared with 8 high-flux dialyzers in high-volume OL-HDF without relevant changes in albumin loss. The global removal score could be a new tool to evaluate the effectiveness of dialyzers and/or different treatment modalities.


Assuntos
Hemodiafiltração/instrumentação , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , alfa-Globulinas/análise , alfa-Globulinas/isolamento & purificação , Creatinina/sangue , Creatinina/isolamento & purificação , Feminino , Hemodiafiltração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/sangue , Mioglobina/isolamento & purificação , Estudos Prospectivos , Diálise Renal/métodos , Albumina Sérica/análise , Albumina Sérica/isolamento & purificação , Ureia/sangue , Ureia/isolamento & purificação , Adulto Jovem , Microglobulina beta-2/sangue , Microglobulina beta-2/isolamento & purificação
13.
Blood Purif ; 48(2): 106-114, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30699421

RESUMO

BACKGROUND: Etelcalcetide is a novel second-generation calcimimetic that, because of its intravenous administration, could improve treatment adherence in secondary hyperparathyroidism (SHPT). The aim of this study was to evaluate the effectiveness of etelcalcetide compared with that of cinacalcet in controlling SHPT in patients under hemodialysis. METHODS: A prospective observational study was performed in 29 patients with SHPT under hemodialysis who switched from cinacalcet to etelcalcetide with a follow-up of 6 months. A survey was conducted of adherence to the oral calcimimetic. The primary end-point of the study was to assess whether etelcalcetide was more effective than cinacalcet in controlling SHPT. RESULTS: After the switch of treatment, none of the patients developed clinical intolerance or new adverse effects. Etelcalcetide was more effective than cinacalcet in controlling intact parathyroid hormone (iPTH), with an overall decrease in iPTH levels that was significant from the second month. Average calcium levels remained within the normal range, with a higher percentage of hypocalcemia with etelcalcetide (6.9 vs. 13.8%), which was asymptomatic in all cases. Patients who were nonadherent to cinacalcet (38%) showed a significant reduction in calcium and iPTH during follow-up with etelcalcetide. The adherent group (62%) also showed a trend to lower iPTH levels reaching statistical significance after 5 months of follow-up. The dose conversion factor for the switch from cinacalcet to etelcalcetide was etelcalcetide/session = 0.111*mg cinacalcet/day + 0.96, R2 = 0.57. CONCLUSIONS: Etelcalcetide was more effective than cinacalcet in this patient population, especially in the nonadherent subgroup, leading to better SHPT control without adverse effects.


Assuntos
Hormônios e Agentes Reguladores de Cálcio/uso terapêutico , Cinacalcete/uso terapêutico , Hiperparatireoidismo Secundário/tratamento farmacológico , Peptídeos/uso terapêutico , Administração Intravenosa , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Cálcio/sangue , Hormônios e Agentes Reguladores de Cálcio/administração & dosagem , Cinacalcete/administração & dosagem , Feminino , Humanos , Hiperparatireoidismo Secundário/sangue , Hiperparatireoidismo Secundário/terapia , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Peptídeos/administração & dosagem , Estudos Prospectivos , Diálise Renal , Adulto Jovem
14.
J Ren Nutr ; 28(5): 324-332, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29691162

RESUMO

OBJECTIVES: To evaluate whether body composition monitor (BCM) could be a practical instrument for nephrologists to assess nutritional status in patients on hemodialysis (HD) and whether it is more effective in identifying patients at highest risk of developing protein-energy wasting (PEW) alone or in combination with other tools currently used for that purpose. DESIGN: Observational cross-sectional study in 91 HD patients (60 ± 14 years, 70.3% male, 24 ± 4.1 kg/m2 body mass index) from 2 different locations. METHODS: Nutritional status was evaluated by anthropometric methods (biceps and triceps skinfold thickness, waist circumference, and arm muscular circumference), biochemical nutritional markers, malnutrition-inflammation score (MIS), and BCM. The patients were grouped into those with and without PEW by using classical criteria and then classified as being adequately or inadequately nourished according to a BCM flow chart to detect those requiring preferential nutritional intervention. A multivariate approach was used to calculate the risk of developing PEW. RESULTS: Anthropometric measurements revealed significantly lower body mass index (<23 kg/m2; odds ratios [OR] = 13.3 and P = 0.001) and arm muscular circumference < p10 (OR = 34, P < 0.001) in the PEW group. MIS was above 5 in all the patients classified as having PEW. BCM showed that fat tissue index < p10 was significantly lower in this group (OR = 1.52), and a decision tree using the lean tissue index < p10, fat tissue index < p10, and extracellular water > 15% revealed that 42.9% of the patients would need nutritional monitoring. On multivariate analysis, insufficient nutritional status detected by BCM decision tree was an independent prognostic factor for developing PEW. About 9.89% of the patients were classified as PEW, with MIS > 5, and insufficient nutritional status detected by BCM required preferential nutritional intervention. CONCLUSION: BCM is a practical instrument for nephrologists to assess nutritional status in patients on HD and is useful for the early prevention and detection of PEW, as is able to identify differences in body composition, predict clinically important outcomes, and classify patients requiring preferential nutritional intervention.


Assuntos
Impedância Elétrica , Falência Renal Crônica/complicações , Avaliação Nutricional , Desnutrição Proteico-Calórica/complicações , Desnutrição Proteico-Calórica/diagnóstico , Diálise Renal , Composição Corporal , Estudos Transversais , Feminino , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Estado Nutricional , Desnutrição Proteico-Calórica/prevenção & controle , Análise Espectral
15.
Am J Physiol Renal Physiol ; 312(4): F673-F681, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28077371

RESUMO

Patients with Stage 5 chronic kidney disease who are on hemodialysis (HD) remain in a chronic inflammatory state, characterized by the accumulation of uremic toxins that induce endothelial damage and cardiovascular disease (CVD). Our aim was to examine microvesicles (MVs), monocyte subpopulations, and angiopoietins (Ang) to identify prognostic markers in HD patients with or without diabetes mellitus (DM). A total of 160 prevalent HD patients from 10 centers across Spain were obtained from the Biobank of the Nephrology Renal Network (Madrid, Spain): 80 patients with DM and 80 patients without DM who were matched for clinical and demographic criteria. MVs from plasma and several monocyte subpopulations (CD142+/CD16+, CD14+/CD162+) were analyzed by flow cytometry, and the plasma concentrations of Ang1 and Ang2 were quantified by ELISA. Data on CVD were gathered over the 5.5 yr after these samples were obtained. MV level, monocyte subpopulations (CD14+/CD162+ and CD142+/CD16+), and Ang2-to-Ang1 ratios increased in HD patients with DM compared with non-DM patients. Moreover, MV level above the median (264 MVs/µl) was associated independently with greater mortality. MVs, monocyte subpopulations, and Ang2-to-Ang1 ratio can be used as predictors for CVD. In addition, MV level has a potential predictive value in the prevention of CVD in HD patients. These parameters undergo more extensive changes in patients with DM.


Assuntos
Angiopoietina-1/sangue , Angiopoietina-2/sangue , Micropartículas Derivadas de Células/metabolismo , Nefropatias Diabéticas/sangue , Nefropatias Diabéticas/terapia , Células Endoteliais/metabolismo , Diálise Renal , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/terapia , Idoso , Biomarcadores/sangue , Estudos de Casos e Controles , Micropartículas Derivadas de Células/patologia , Nefropatias Diabéticas/diagnóstico , Nefropatias Diabéticas/mortalidade , Progressão da Doença , Células Endoteliais/patologia , Feminino , Humanos , Mediadores da Inflamação/sangue , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Monócitos/metabolismo , Valor Preditivo dos Testes , Prevalência , Diálise Renal/efeitos adversos , Diálise Renal/mortalidade , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Espanha/epidemiologia , Fatores de Tempo , Resultado do Tratamento
16.
FASEB J ; 30(2): 564-77, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26443817

RESUMO

We have investigated the potential role of molecular chaperones as modulators of the immune response by using α-synuclein (αSyn) as an aggregation-prone model protein. We first performed an in vitro immunoscreening with 21 preselected candidate chaperones and selected 2 from this set as displaying immunological activity with differential profiles, Grp94/Gp96 and FKBP4/52. We then immunized mice with both chaperone/α-synuclein combinations using monomeric or oligomeric α-synuclein (MαSyn or OαSyn, respectively), and we characterized the immune response generated in each case. We found that Grp94 promoted αSyn-specific T-helper (Th)1/Th17 and IgG1 antibody responses (up to a 3-fold increase) with MαSyn and OαSyn, respectively, coupled to a Th2-type general phenotype (generating 2.5-fold higher IgG1/IgG2 levels). In addition, we observed that FKBP4 favored a Th1-skewed phenotype with MαSyn but strongly supported a Th2-type phenotype with OαSyn (with a 3-fold higher IL-10/IFN-γ serum levels). Importantly, results from adoptive transfer of splenocytes from immunized animals in a Parkinson's disease mouse model indicates that these effects are robust, stable in time, and physiologically relevant. Taken together, Grp94 and FKBP4 are able to generate differential immune responses to α-synuclein-based immunizations, depending both on the nature of the chaperone and on the aggregation state of α-synuclein. Our work reveals that several chaperones are potential modulators of the immune response and suggests that different chaperones could be exploited to redirect the amyloid-elicited immunity both for basic studies of the immunological processes associated with neurodegeneration and for immunotherapy of pathologies associated with protein misfolding and aggregation.


Assuntos
Glicoproteínas de Membrana/metabolismo , Chaperonas Moleculares/fisiologia , Proteínas de Ligação a Tacrolimo/metabolismo , alfa-Sinucleína/metabolismo , Imunidade Adaptativa , Animais , Regulação da Expressão Gênica , Proteínas de Choque Térmico HSP70/genética , Proteínas de Choque Térmico HSP70/metabolismo , Humanos , Imunidade Inata , Masculino , Glicoproteínas de Membrana/imunologia , Camundongos , Camundongos Endogâmicos C57BL , Dobramento de Proteína , Proteínas de Ligação a Tacrolimo/genética , Proteínas de Ligação a Tacrolimo/imunologia , alfa-Sinucleína/genética
17.
Cell Mol Life Sci ; 73(20): 3897-916, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27117550

RESUMO

Alphavirus budding is driven by interactions between nucleocapsids assembled in the cytoplasm and envelope proteins present at the plasma membrane. So far, the expression of capsid and envelope proteins in infected cells has been considered an absolute requirement for alphavirus budding and propagation. In the present study, we show that Semliki Forest virus and Sindbis virus lacking the capsid gene can propagate in mammalian and insect cells. This propagation is mediated by the release of infectious microvesicles (iMVs), which are pleomorphic and have a larger size and density than wild-type virus. iMVs, which contain viral RNA inside and viral envelope proteins on their surface, are released at the plasma membrane and infect cells using the endocytic pathway in a similar way to wild-type virus. iMVs are not pathogenic in immunocompetent mice when injected intravenously, but can infect different organs like lungs and heart. Finally, we also show that alphavirus genomes without capsid can mediate the propagation of heterologous genes, making these vectors potentially interesting for gene therapy or vaccination studies. The minimalist infectious system described in this study shows that a self-replicating RNA able to express membrane proteins with binding and fusion properties is able to propagate, providing some insights into virus evolution.


Assuntos
Alphavirus/patogenicidade , Capsídeo/metabolismo , Membrana Celular/virologia , Micropartículas Derivadas de Células/virologia , Alphavirus/genética , Animais , Fusão Celular , Linhagem Celular , Micropartículas Derivadas de Células/metabolismo , Micropartículas Derivadas de Células/ultraestrutura , Feminino , Genoma Viral , Proteínas de Fluorescência Verde/metabolismo , Humanos , Camundongos Endogâmicos C57BL , Testes de Neutralização , RNA Viral/metabolismo , Vírus da Floresta de Semliki/patogenicidade , Transfecção , Proteínas do Envelope Viral/metabolismo , Proteínas Virais/metabolismo
18.
Adv Exp Med Biol ; 978: 255-275, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28523551

RESUMO

Despite being clinically described 150 years ago, the mechanisms underlying amyotrophic lateral sclerosis (ALS) pathogenesis have not yet been fully understood. Studies in both animal models of ALS and human patients reveal a plethora of alterations such as increased glutamate-mediated excitotoxicity, redox stress, increased apoptosis, defective axonal transport, protein-misfolding events, mitochondrial impairment and sustained unregulated immune responses. Regardless of being sporadic or familiar ALS, the final outcome at the cellular level is the death of upper and lower motor neurons, and once diagnosed, ALS is typically lethal within the next 5 years. There are neither clear biomarkers nor therapeutic or disease-modifying treatments for ALS.Accumulating evidence supports the concept that epigenetic-driven modifications, including altered chromatin remodelling events, RNA editing and non-coding RNA molecules, might shed light into the pathogenic mechanisms underlying sporadic/familiar ALS onset and/or severity to facilitate the identification of effective therapies, early diagnosis and potentially early-stage therapeutic interventions to increase the survival outcome of ALS patients.


Assuntos
Esclerose Lateral Amiotrófica/genética , Epigênese Genética/genética , Regulação da Expressão Gênica/genética , Acetilação , Esclerose Lateral Amiotrófica/tratamento farmacológico , Esclerose Lateral Amiotrófica/metabolismo , Esclerose Lateral Amiotrófica/patologia , Animais , Metilação de DNA/genética , Modelos Animais de Doenças , Exposição Ambiental , Interação Gene-Ambiente , Código das Histonas/genética , Inibidores de Histona Desacetilases/uso terapêutico , Histona Desacetilases/fisiologia , Humanos , MicroRNAs/genética , Neurônios Motores/metabolismo , Neurônios Motores/patologia , Mutação , Estresse Oxidativo , Processamento de Proteína Pós-Traducional , Riluzol/uso terapêutico , Superóxido Dismutase-1/deficiência , Superóxido Dismutase-1/genética
19.
J Immunol ; 190(6): 2994-3004, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23401594

RESUMO

Semliki Forest virus vectors expressing IL-12 (SFV-IL-12) were shown to induce potent antitumor responses against s.c. MC38 colon adenocarcinomas in immunocompetent mice. However, when MC38 tumors were implanted in liver, where colon tumors usually metastasize, SFV-IL-12 efficacy was significantly reduced. We reasoned that characterization of immune responses against intrahepatic tumors in responder and nonresponder animals could provide useful information for designing more potent antitumor strategies. Remarkably, SFV-IL-12 induced a high percentage of circulating tumor-specific CD8 T cells in all treated animals. Depletion studies showed that these cells were essential for SFV-IL-12 antitumor activity. However, in comparison with nonresponders, tumor-specific cells from responder mice acquired an effector-like phenotype significantly earlier, were recruited more efficiently to the liver, and, importantly, persisted for a longer period of time. All treated mice had high levels of functional specific CD8 T cells at 8 d posttreatment reflected by both in vivo killing and IFN-γ-production assays, but responder animals showed a more avid and persistent IFN-γ response. Interestingly, differences in immune responses between responders and nonresponders seemed to correlate with the immune status of the animals before treatment and were not due to the treatment itself. Mice that rejected tumors were protected against tumor rechallenge, indicating that sustained memory responses are required for an efficacious therapy. Interestingly, tumor-specific CD8 T cells of responder animals showed upregulation of IL-15Rα expression compared with nonresponders. These results suggest that SFV-IL-12 therapy could benefit from the use of strategies that could either upregulate IL-15Rα expression or activate this receptor.


Assuntos
Interleucina-12/biossíntese , Neoplasias Hepáticas Experimentais/imunologia , Neoplasias Hepáticas Experimentais/prevenção & controle , Vírus da Floresta de Semliki/imunologia , Vírus da Floresta de Semliki/metabolismo , Adenocarcinoma/imunologia , Adenocarcinoma/prevenção & controle , Adenocarcinoma/virologia , Infecções por Alphavirus/imunologia , Infecções por Alphavirus/prevenção & controle , Infecções por Alphavirus/virologia , Animais , Linfócitos T CD8-Positivos/imunologia , Linhagem Celular , Células Cultivadas , Neoplasias Colorretais/imunologia , Neoplasias Colorretais/prevenção & controle , Neoplasias Colorretais/virologia , Cricetinae , Feminino , Vetores Genéticos/administração & dosagem , Vetores Genéticos/imunologia , Vetores Genéticos/metabolismo , Interleucina-12/genética , Neoplasias Hepáticas Experimentais/virologia , Camundongos , Camundongos Endogâmicos C57BL
20.
Blood Purif ; 39(4): 288-96, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25925334

RESUMO

BACKGROUND: In a previous study on a nocturnal, every-other-day online haemodiafiltration scheme, different removal patterns were observed for urea, creatinine, ß2-​microglobulin, myoglobin and prolactin. The aim of this study was to evaluate the influence of dialysis duration and infusion flow (Qi) on the removal of different molecular weight (MW) solutes, and to quantify the effect of the different treatments on the kinetics of the solutes by using a classical two-compartment model. METHODS: This prospective, in-center study was carried out in 10 patients on a nocturnal, every-other-day online post-dilution haemodiafiltration program. Each patient received four dialysis sessions with different conditions, two 4-h sessions (with infusion flows of 50 or 100 ml/min) and two 8-h sessions (with infusion flows of 50 or 100 ml/min). To analyze the solute kinetics, blood samples were obtained hourly during the dialysis treatments and in the first 3 h post-dialysis. RESULTS: Removal patterns differed in the molecules studied, which were quantified by means of the two-compartment mathematical model. The main results show the impact of dialysis duration on the removal of low molecular weight molecules (urea and creatinine), while the impact of Qi is clearly shown for high molecular weight molecules (myoglobin and prolactin). For middle molecular weight solutes, such as ß2-microglobulin, both factors (duration and Qi) enhance the removal efficiency of the dialyzer. CONCLUSIONS: Our study evaluates experimentally and mathematically how treatment time and infusion flow affect the filtration of solutes of different MW during post-dilution haemodiafiltration. The results provided by the present study should help physicians to select and individualise the most appropriate schedules to deliver an optimum diffusive and convective dialysis dose for each patient.


Assuntos
Hemodiafiltração/métodos , Modelos Teóricos , Adulto , Idoso , Algoritmos , Feminino , Hemodiafiltração/normas , Soluções para Hemodiálise , Humanos , Masculino , Pessoa de Meia-Idade , Peso Molecular , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA