Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 19(16)2019 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-31405181

RESUMO

Sensitive and selective personal exposure monitors are needed to assess ozone (O3) concentrations in the workplace atmosphere in real time for the analysis and prevention of health risks. Here, a cumulative gas sensor using visible spectroscopy for real-time O3 determination is described. The sensing chip is a mesoporous silica thin film deposited on transparent glass and impregnated with methylene blue (MB). The sensor is reproducible, stable for at least 50 days, sensitive to 10 ppb O3 (one-tenth of the occupational exposure limit value in France, Swiss, Canada, U.K., Japan, and the USA) with a measurement range tested up to 500 ppb, and insensitive to NO2 and to large variation in relative humidity. A model and its derivative as a function of time are proposed to convert in real time the sensor response to concentrations, and an excellent correlation was obtained between those data and reference O3 concentrations. This sensor is based on a relatively cheap sensing material and a robust detection system, and its analytical performance makes it suitable for monitoring real-time O3 concentrations in workplaces to promote a safer environment for workers.

2.
J Occup Environ Hyg ; 14(7): 551-561, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28426293

RESUMO

Polymers processed to produce plastic articles are subjected to temperatures between 150°C and 450°C or more during overheated processing and breakdowns. Heat-based processing of this nature can lead to emission of volatile organic compounds (VOCs) into the thermoplastic processing shop. In this study, laboratory experiments, qualitative and quantitative emissions measurement in thermoplastic factories were carried out. The first step was to identify the compounds released depending on the thermoplastic nature, the temperature and the type of process. Then a thermal degradation protocol that can extrapolate the laboratory results to industry scenarios was developed. The influence of three parameters on released thermal breakdown products was studied: the sample preparation methods-manual cutting, ambient, or cold grinding-the heating rate during thermal degradation-5, 10 20, and 50°C/min-and the decomposition method-thermogravimetric analysis and pyrolysis. Laboratory results were compared to atmospheric measurements taken at 13 companies to validate the protocol and thereby ensure its representativeness of industrial thermal processing. This protocol was applied to most commonly used thermoplastics to determine their thermal breakdown products and their thermal behaviour. Emissions data collected by personal exposure monitoring and sampling at the process emission area show airborne concentrations of detected compounds to be in the range of 0-3 mg/m3 under normal operating conditions. Laser cutting or purging operations generate higher pollution levels in particular formaldehyde which was found in some cases at a concentration above the workplace exposure limit.


Assuntos
Poluentes Ocupacionais do Ar/análise , Temperatura Alta , Plásticos/química , Compostos Orgânicos Voláteis/análise , Formaldeído/análise , Humanos , Exposição Ocupacional/análise
4.
Talanta ; 81(1-2): 543-8, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20188960

RESUMO

This paper describes a system for the detection of nitroaromatic explosives consisting of a portable detector based on a specific fluorescent material. The developed sensor was able to perform an ultra trace detection of explosives, such as trinitrotoluene (TNT) or its derivate 2,4-dinitrotoluene (DNT), in ambient air or on objects tainted with explosives. In the presence of nitroaromatic vapors, the fluorescence of the material was found to decrease due to the adsorption of nitroaromatic molecules on its specific adsorption sites. The sensor exhibited a large sensitivity to TNT or DNT at their vapor pressures (respectively 6 and 148 ppbv) and the detection threshold was evaluated on a laboratory test setup and was found to be 0.75 ppbv for TNT. Moreover, the detector demonstrated no loss of performance in the presence of humidity or interfering compounds. All the tests led to the conclusion that the sensor fulfills the main requirements for the identification of suspect luggage, forensic analyses or battlefields clearing.


Assuntos
Ar/análise , Substâncias Explosivas/análise , Espectrometria de Fluorescência/métodos , Transporte de Elétrons , Substâncias Explosivas/química , Iminas/química , Laboratórios , Fenômenos Ópticos , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA