Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Electrophoresis ; 40(18-19): 2256-2262, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30793781

RESUMO

1-propanol is a primary alcohol extensively used in the pharmaceutical, chemical, and food industries. It has been also found as a contaminant in the atmosphere and is considered a model compound to mimic the behavior and fate of aliphatic alcohols exposed to environmental conditions. In order to understand that role of relevant variables, this paper presents results obtained with a simple experimental set-up to investigate the reactivity of 1-propanol under mild oxidizing conditions. Coupling this system with CE-C4 D allowed the quantification of the carboxylic acids formed. For the described experiments, aqueous solutions of 1-propanol were placed inside a photoreactor and oxidized upon the addition of TiO2 and/or H2 O2 . According to the described results, the addition of H2 O2 (0.1% w/w) was the most significant variable, roughly tripled the amount of carboxylic acids generated and led to the conversion of up to 70% of the initially available 1-propanol (1 mmol/L). More importantly, the reaction yielded the formation (within 10 min) of propionate (50 µmol/L), acetate (400 µmol/L), formate (50 µmol/L), and malonate (200 µmol/L). The latter is critically important because it represents the first example of the photochemical oxidation of both terminal carbons of the C3 -chain of 1-propanol under mild conditions, and opens new avenues for the production of this important chemical building block.


Assuntos
1-Propanol , Peróxido de Hidrogênio , Fotólise , 1-Propanol/análise , 1-Propanol/química , 1-Propanol/efeitos da radiação , Condutividade Elétrica , Eletroforese Capilar , Malonatos/análise , Malonatos/química , Oxirredução , Fotólise/efeitos dos fármacos , Fotólise/efeitos da radiação , Raios Ultravioleta
2.
Chem Res Toxicol ; 31(5): 332-339, 2018 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-29707942

RESUMO

Air pollution is a major environmental risk for human health. Acetaldehyde is present in tobacco smoke and vehicle exhaust. In this study, we show that [13C2]-acetaldehyde induces DNA modification with the formation of isotopically labeled 1, N2-propano-2'-deoxyguanosine adducts in the brain and lungs of rats exposed to concentrations of acetaldehyde found in the atmosphere of megacities. The adduct, with the addition of two molecules of isotopically labeled acetaldehyde [13C4]-1, N2-propano-dGuo, was detected in the lung and brain tissues of exposed rats by micro-HPLC/MS/MS. Structural confirmation of the products was unequivocally performed by nano-LC/ESI+-HRMS3 analyses. DNA modifications induced by acetaldehyde have been regarded as a key factor in the mechanism of mutagenesis and may be involved in the cancer risks associated with air pollution.


Assuntos
Acetaldeído/toxicidade , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Adutos de DNA/biossíntese , Pulmão/efeitos dos fármacos , Pulmão/metabolismo , Acetaldeído/administração & dosagem , Acetaldeído/química , Animais , Isótopos de Carbono , Adutos de DNA/química , Adutos de DNA/isolamento & purificação , Masculino , Estrutura Molecular , Ratos , Ratos Wistar
3.
Anal Chem ; 89(2): 1362-1368, 2017 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-27992170

RESUMO

Concurrently with ethanol, many other compounds can be formed during the fermentation of grains and fruits. Among those, methanol is particularly important (because of its toxicity) and is typically formed at concentrations much lower than ethanol, presenting a particular challenge that demands the implementation of separation techniques. Aiming to provide an alternative to traditional chromatographic approaches, a hybrid electrophoresis device with electrochemical preprocessing and contactless conductivity detection (hybrid EC-CE-C4D) is herein described. The device was applied to perform the electro-oxidation of primary alcohols, followed by the separation and detection of the respective carboxylates. According to the presented results, the optimum conditions were obtained when the sample was diluted with 2 mmol L-1 HNO3 and then electro-oxidized by applying a potential of 1.4 V for 60 s. The oxidation products were then electrokinetically injected by applying a potential of 3 kV for 4 s and separated using a potential of 3 kV and a background running electrolyte (BGE) consisting of 10 mmol L-1 N-cyclohexyl-2-aminoethanesulfonic acid (CHES) and 5 mmol L-1 sodium hydroxide (NaOH). n-Propanol was used as an internal standard and the three carboxylate peaks were resolved with baseline separation within <3 min, defining linear calibration curves in the range of 0.10-5.0 mmol L-1. Limits of detection (LODs) of 20, 40, and 50 µmol L-1 were obtained for ethanol, n-propanol, and methanol, respectively. To demonstrate the applicability of the proposed strategy, a laboratory-made sample (moonshine) was used. Aliquots collected along the beginning of the fractional distillation presented a decreasing methanol ratio (from 4% to <0.5%) and a growing ethanol ratio (from 80% to 100%) in the collected volume.

4.
Electrophoresis ; 38(21): 2725-2732, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28485016

RESUMO

An EC-CE-C4 D flow system was applied to the investigation of electrocatalytic processes by monitoring carboxylic acids formed during the electro-oxidation at various potentials of primary alcohols (mixture of 1 mmol/L of ethanol, n-propanol, n-butanol and n-pentanol) in acidic, neutral and alkaline media. The electro-oxidation was carried out on gold and platinum disk electrodes (3 mm of diameter) in a thin-layer electrochemical flow cell. Products were sampled 50 µm apart from the electrode directly into the capillary. All the generated carboxylates were determined in near real time (less than 2 min) by CE-C4 D in counter-flow mode, with Tris/HCl buffer solution (pH 8.6) as BGE. Long sequences of 5-min experiments were run automatically, exploring the applied potential, electrolysis time and solution composition. Electro-oxidation at 1.5 V (versus Ag/AgCl quasi-reference) during 50 s in acidic medium was found appropriate for both Pt and Au electrodes when the determination of alcohols after derivatization is intended. A noteworthy selectivity effect was observed on the Au electrode. The signal corresponding to pentanoate is similar on both electrodes while the signal of ethanoate (acetate) is four times larger on gold than on platinum. The carboxylate signals were lower in alkaline medium (below the determination limit on Pt) than in acidic and neutral media. On gold, the formation of carboxylates was anticipated (0.85 V in alkaline medium versus 1.40 V in neutral medium). The automatic online monitoring of electrochemical processes by EC-CE-C4 D holds great potential to investigate ionic/ionizable intermediates/products of new electrocatalysts and/or alternative fuels.


Assuntos
Álcoois/química , Eletroforese Capilar/métodos , Ouro/química , Platina/química , Catálise , Condutividade Elétrica , Técnicas Eletroquímicas/instrumentação , Eletrodos , Eletrólise , Concentração de Íons de Hidrogênio , Limite de Detecção , Oxirredução
5.
Electrophoresis ; 37(12): 1691-5, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27028724

RESUMO

Glass is one of the most convenient materials for the development of microfluidic devices. However, most fabrication protocols require long processing times and expensive facilities. As a convenient alternative, polymeric materials have been extensively used due their lower cost and versatility. Although CO2 laser ablation has been used for fast prototyping on polymeric materials, it cannot be applied to glass devices because the local heating causes thermal stress and results in extensive cracking. A few papers have shown the ablation of channels or thin holes (used as reservoirs) on glass but the process is still far away from yielding functional glass microfluidic devices. To address these shortcomings, this communication describes a simple method to engrave glass-based capillary electrophoresis devices using standard (1 mm-thick) microscope glass slides. The process uses a sacrificial layer of wax as heat sink and enables the development of both channels (with semicircular shape) and pass-through reservoirs. Although microscope images showed some small cracks around the channels (that became irrelevant after sealing the engraved glass layer to PDMS) the proposed strategy is a leap forward in the application of the technology to glass. In order to demonstrate the capabilities of the approach, the separation of dopamine, catechol and uric acid was accomplished in less than 100 s.


Assuntos
Eletroforese Capilar/instrumentação , Dispositivos Lab-On-A-Chip , Dióxido de Carbono , Catecóis/isolamento & purificação , Dopamina/isolamento & purificação , Gravuras e Gravação , Vidro , Lasers de Gás , Ácido Úrico/isolamento & purificação , Ceras
6.
Curr Heart Fail Rep ; 13(4): 166-71, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27287200

RESUMO

Heart failure (HF) is a clinical condition that presents high morbidity and mortality and is one of the main reasons for hospital admissions all over the world. Although biochemical processes that occur in the body during heart failure are known, this syndrome is still associated to poor prognosis. Exhaled breath analysis has emerged as a promising noninvasive tool in different clinical conditions and, recently, it has been also tested in patients with HF. This review presents the main breath HF biomarkers, which reflect metabolic changes that occur in this complex syndrome. It also discusses the diagnostic and prognostic value of exhaled breath compounds for HF and makes a short description of the main technologies involved in this analysis. Some perspectives on the area are presented as well.


Assuntos
Testes Respiratórios , Expiração , Insuficiência Cardíaca/metabolismo , Biomarcadores/metabolismo , Humanos , Prognóstico
7.
Langmuir ; 31(14): 4351-60, 2015 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-25812035

RESUMO

The structure of polytetraruthenated nickel porphyrin was unveiled for the first time by electrochemistry, Raman spectroelectrochemistry, and a hydroxyl radical trapping assay. The electrocatalytic active material, precipitated on the electrode surface after successive cycling of [NiTPyP{Ru(bipy)2Cl}4](4+) species in strong aqueous alkaline solution (pH 13), was found to be a peroxo-bridged coordination polymer. The electropolymerization process involves hydroxyl radicals (as confirmed by the characteristic set of DMPO/(•)OH adduct EPR peaks) as reaction intermediates, electrocatalytically generated in the 0.80-1.10 V range, that induce the formation of Ni-O-O-Ni coordination polymers, as evidenced by Raman spectroelectrochemistry and molecular modeling studies. The film growth is halted above 1.10 V due to the formation of oxygen gas bubbles.

8.
Electrophoresis ; 35(6): 864-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24254441

RESUMO

The simultaneous determination of cationic, anionic, and neutral analytes in a real sample was demonstrated by coupling electrochemical (EC) derivatization with counter-EOF CE-C(4) D. An EC flow cell was used to oxidize alcohols from an antiseptic mouthwash sample into carboxylic acids at a platinum electrode in acid medium. The carboxylates formed in the derivatization process and other sample ingredients, such as benzoate, saccharinate, and sodium ions, were separated in counter-flow mode and detected in one run in Tris-HCl buffer, pH 8.6. Fewer than 5 min were needed to complete each analysis with the automated flow system comprising solenoid pumps for the management of solutions. Insights into the electrochemistry of benzoic acid, present in the sample matrix, were also gained by EC-CE-C(4) D; more specifically, by applying potentials higher than 1.47 V to the platinum electrode, some formiate and minute amounts of salicylate were detected.


Assuntos
Ânions/análise , Cátions/análise , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Ácido Benzoico , Condutividade Elétrica , Eletro-Osmose , Oxirredução
9.
Anal Chem ; 84(18): 7599-602, 2012 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-22931091

RESUMO

A thin-layer electrochemical flow cell coupled to capillary electrophoresis with contactless conductivity detection (EC-CE-C(4)D) was applied for the first time to the derivatization and quantification of neutral species using aliphatic alcohols as model compounds. The simultaneous electrooxidation of four alcohols (ethanol, 1-propanol, 1-butanol, and 1-pentanol) to the corresponding carboxylates was carried out on a platinum working electrode in acid medium. The derivatization step required 1 min at 1.6 V vs. Ag/AgCl under stopped flow conditions, which was preceded by a 10 s activation at 0 V. The solution close to the electrode surface was then hydrodynamically injected into the capillary, and a 2.5 min electrophoretic separation was carried out. The fully automated flow system operated at a frequency of 12 analyses per hour. Simultaneous determination of the four alcohols presented detection limits of about 5 × 10(-5) mol L(-1). As a practical application with a complex matrix, ethanol concentrations were determined in diluted pale lager beer and in nonalcoholic beer. No statistically significant difference was observed between the EC-CE-C(4)D and gas chromatography with flame ionization detection (GC-FID) results for these samples. The derivatization efficiency remained constant over several hours of continuous operation with lager beer samples (n = 40).

10.
Electrophoresis ; 32(8): 939-46, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21394730

RESUMO

This paper describes the automation of a fully electrochemical system for preconcentration, cleanup, separation and detection, comprising the hyphenation of a thin layer electrochemical flow cell with CE coupled with contactless conductivity detection (CE-C4D). Traces of heavy metal ions were extracted from the pulsed-flowing sample and accumulated on a glassy carbon working electrode by electroreduction for some minutes. Anodic stripping of the accumulated metals was synchronized with hydrodynamic injection into the capillary. The effect of the angle of the slant polished tip of the CE capillary and its orientation against the working electrode in the electrochemical preconcentration (EPC) flow cell and of the accumulation time were studied, aiming at maximum CE-C4D signal enhancement. After 6 min of EPC, enhancement factors close to 50 times were obtained for thallium, lead, cadmium and copper ions, and about 16 for zinc ions. Limits of detection below 25 nmol/L were estimated for all target analytes but zinc. A second separation dimension was added to the CE separation capabilities by staircase scanning of the potentiostatic deposition and/or stripping potentials of metal ions, as implemented with the EPC-CE-C4D flow system. A matrix exchange between the deposition and stripping steps, highly valuable for sample cleanup, can be straightforwardly programmed with the multi-pumping flow management system. The automated simultaneous determination of the traces of five accumulable heavy metals together with four non-accumulated alkaline and alkaline earth metals in a single run was demonstrated, to highlight the potentiality of the system.


Assuntos
Eletroforese Capilar/instrumentação , Metais/análise , Cátions/análise , Condutividade Elétrica , Eletrodos , Eletroforese Capilar/métodos , Desenho de Equipamento
11.
Talanta ; 223(Pt 2): 121780, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33298285

RESUMO

A new composite electrode (G-PSE) was developed from graphite powder and expanded polystyrene (EPS, Styrofoam) by simply dissolving the foam in chloroform, incorporating the graphite particles under mixing and volatilizing the solvent at 80 °C. The resulting rigid black composite can be softened with acetone and so it can easily be molded to any shape, e.g., into a PTFE tube with an electric contact, to build the electrode. A 75% graphite content (w/w) was found appropriate for preparing the G-PSE with a working potential similar to that of carbon paste electrodes, superior mechanical stability and a much faster response to ferrocyanide, close to reversible and similar to that of the much more expensive glassy carbon electrode. Applications of the G-PSE to dipyrone and paracetamol quantification in pharmaceutical formulations were demonstrated. The results accomplished by flow injection analysis with amperometric detection at the G-PSE were successfully validated against standards methods.

12.
ACS Omega ; 6(1): 594-605, 2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33458511

RESUMO

Cocaine (COC) is one of the most widely consumed illegal drugs around the world. Street COC is commonly adulterated with pharmaceutical compounds that mimic or intensify the COC's sensory effect. Adulteration is performed to increase the profit of criminal organizations and each one has their own way of doing it. Therefore, determining the composition of seized COC samples (chemical profile) provides evidence for the police to track criminal organization networks and their activity patterns. Using filter paper as a substrate, we developed a multiple detection paper-based analytical device (PAD) that combines colorimetric and electrochemical measurements to discriminate COC samples according to adulterant's content. A regular graphite lead modified with a gold film made from Au leaf (graphite/Au) to improve electron transfer was used as a working electrode. Silver and Ag/AgCl were used as auxiliary and reference electrodes, respectively. The colorimetric device was patterned using a laser cutter and coupled to the electrochemical device using a double-sided tape, allowing simultaneous analysis to gather more analytical information about COC samples. Graphite/Au was characterized by scanning and transmission electron microscopies and electrochemical assays. The simultaneous colorimetric and electrochemical analyses combined to principal component analysis improved the analytical characterization of COC trial samples and provided a fast discrimination based on the assembled database.

13.
Anal Methods ; 12(33): 4109-4115, 2020 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-32744541

RESUMO

The present work describes an Integrated Teaching Tool (ITT) to facilitate the learning process in analytical chemistry. The first instrument integrated in the platform to demonstrate the concept is a wireless, portable fluorometer, produced by 3D printing. The low-cost instrument features a Teensy 3.1 board as the microcontroller, a high-power UV-LED, a secondary filter, a photodiode, and simple auxiliary electronic circuits. Modules of the ITT app were designed to manage the instrument and perform data acquisition remotely from any Android smartphone via Bluetooth, plot and transmit the results. Supporting the educational purpose of the platform, examples of basic concepts about fluorescence as well as technical information about the instrument are also provided to be considered for the app, which also allows instructors to assist and evaluate students through push notifications.

14.
ESC Heart Fail ; 7(4): 1744-1752, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32383349

RESUMO

AIMS: Exhaled breath acetone (EBA) has been described as a new biomarker of heart failure (HF) diagnosis. EBA concentration increases according to severity of HF and is associated with poor prognosis, especially in acute decompensated HF. However, there are no data on chronic HF patients. The aim is to evaluate the role of EBA for predicting cardiac and overall mortality in chronic HF patients. METHODS AND RESULTS: In GENIUS-HF cohort, chronic patients were enrolled between August 2012 and December 2014. All patients had left ventricular ejection fraction ≤ 50%, and the diagnosis was established according to Framingham criteria. After consent, patients were submitted to clinical evaluation and exhaled breath collection. EBA identification and quantitative determination were done by spectrophotometry. The clinical characteristics associated with acetone were identified. All participants were followed for 18 months to assess cardiac and overall mortality. Around 700 participants were enrolled in the current analysis. Patients were 55.4 ± 12.2 years old, 67.6% male patients, and 81% New York Heart Association I/II with left ventricular ejection fraction of 32 ± 8.6%. EBA median concentration was 0.6 (0.3-1.2) ug/L. Acetone levels increased with the number of symptoms of HF and were associated with right HF signs/symptoms and liver biochemical changes. EBA at highest quartile (EBA > 1.2ug/L) was associated with a significantly worse prognosis (log rank test, P < 0.001). Cox proportional multivariable regression model revealed that EBA > 1.20ug/L was an independent predictor of cardiac (P = 0.011) and overall (P = 0.010) mortality in our population. CONCLUSIONS: This study shows that EBA levels reflect clinical HF features, especially right HF signs/symptoms. EBA is an independent predictor of cardiac and overall mortality in chronic HF patients.


Assuntos
Acetona , Insuficiência Cardíaca , Adulto , Idoso , Expiração , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Esquerda
15.
Food Chem ; 292: 114-120, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31054654

RESUMO

The determination of ethanol is one of the most important parameters in the fermentation industry, influencing not only the production yield and the quality of the product, but also its commercial value. In addition to the traditional approach based on distillation/density, procedure that is considered laborious and time-consuming, methods based on chromatography are widely used. Alternatives using electrochemical, spectroscopic and colorimetric techniques have been also proposed for alcohol analysis. In general, these methods not only offer limited throughput, but also require harsh reaction conditions and/or complex instrumentation. Aiming to address these shortcomings, we propose a fast, simple and clean analytical approach for the determination of primary alcohols based on the photochemical oxidation under UV-LED irradiation in the presence of H2O2. The proposed method was successfully applied to the analysis of 12 different types of alcoholic beverages with an alcohol content ranging from 5% v/v (beer) to 53% v/v (whiskey).


Assuntos
Eletroforese Capilar/métodos , Etanol/análise , Bebidas Alcoólicas/análise , Ácido Benzoico/análise , Etanol/química , Histidina/análise , Peróxido de Hidrogênio/análise , Oxirredução , Raios Ultravioleta
16.
Talanta ; 178: 1040-1045, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136794

RESUMO

Methods for determination of glycerol and its electrooxidation products (neutral diols and carboxylates) by capillary electrophoresis (CE) with dual capacitively coupled contactless conductivity detectors (C4D) are presented. Glycerol, dihydroxyacetone and glyceraldehyde were detected as anionic borate complexes in less than 3min under counter Electroosmotic Flow (EOF) mode (resolution of the critical pair of 1.8). Limits of detection (LODs) of 15, 15 and 10µmolL-1 were obtained for glycerol, dihydroxyacetone and glyceraldehyde, respectively. Two methods of separation were used for the separation of carboxylates. The first one used the same Back Ground Electrolyte (BGE) containing borate, and the second used a BGE (pH 6.1) composed by 2-(N-morpholino)ethanesulfonic acid (MES), L-Histidine and a flow modifier. Better separation and LODs for carboxylates were obtained using Mes/Histidine as BGE. However, along with the non-applicability of this BGE to the determination of neutral diols, observation of the C4D signals at two different points of the capillary (10 and 50cm apart from the injection tip) revealed interaction of the flow modifier with some species (mesoxalate and glyoxylate). The electrooxidation of a glycerol sample in alkaline media on an 8cm2 gold working electrode was evaluated by the developed methods. After 16h of electrolysis, 87% of the glycerol had been oxidized and formate, glycolate, hydroxypyruvate and glycerate were detected as the main products.


Assuntos
Ácidos Carboxílicos/química , Capacitância Elétrica , Condutividade Elétrica , Eletroforese Capilar , Glicerol/química , Glicóis/química , Eletroquímica , Oxirredução
17.
Talanta ; 179: 507-511, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29310267

RESUMO

Gold is among the most used materials in electrocatalysis. Despite this, this noble metal is still too expensive to be used in the fabrication of low cost and disposable devices. In the present work, gold-leaf sheets, usually employed in decorative crafts and wedding candies, is introduced as an inexpensive source of gold. Planar-disc and nanoband gold electrodes were simply and easily manufactured by combining gold leaf and polyimide tape. The planar disc electrode exhibited electrochemical behavior similar to that of a commercial gold electrode in 0.2molL-1 H2SO4; cyclic voltammetry of a 1mmolL-1 solution of potassium ferricyanide (K3[Fe(CN)6]) in 0.2molL-1 KNO3, using this novel electrode, displayed an 80mV difference between the oxidation and reduction peak potentials. The electrode also delivers promising prospects for the development of wearable devices. When submitted to severe mechanical deformation, this electrode exhibited neither loss of electrical contact nor significant variation in electrode response, even after fifteen bending and/or folding cycles. The thickness of the gold-leaf sheet facilitates the production of nanoband electrodes with behavior similar to that of ultramicroelectrodes. The electrode surface is easily renewed by cutting a thin slice off its end with a razor blade; this process led to limiting currents that were reproducible, presenting a relative standard deviation (RSD) of 3.8% (n = 5).

18.
PLoS One ; 11(12): e0168790, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28030609

RESUMO

BACKGROUND: The identification of new biomarkers of heart failure (HF) could help in its treatment. Previously, our group studied 89 patients with HF and showed that exhaled breath acetone (EBA) is a new noninvasive biomarker of HF diagnosis. However, there is no data about the relevance of EBA as a biomarker of prognosis. OBJECTIVES: To evaluate whether EBA could give prognostic information in patients with heart failure with reduced ejection fraction (HFrEF). METHODS: After breath collection and analysis by gas chromatography-mass spectrometry and by spectrophotometry, the 89 patients referred before were followed by one year. Study physicians, blind to the results of cardiac biomarker testing, ascertained vital status of each study participant at 12 months. RESULTS: The composite endpoint death and heart transplantation (HT) were observed in 35 patients (39.3%): 29 patients (32.6%) died and 6 (6.7%) were submitted to HT within 12 months after study enrollment. High levels of EBA (≥3.7µg/L, 50th percentile) were associated with a progressively worse prognosis in 12-month follow-up (log-rank = 11.06, p = 0.001). Concentrations of EBA above 3.7µg/L increased the risk of death or HT in 3.26 times (HR = 3.26, 95%CI = 1.56-6.80, p = 0.002) within 12 months. In a multivariable cox regression model, the independent predictors of all-cause mortality were systolic blood pressure, respiratory rate and EBA levels. CONCLUSIONS: High EBA levels could be associated to poor prognosis in HFrEF patients.


Assuntos
Acetona/metabolismo , Expiração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/metabolismo , Adulto , Testes Respiratórios , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
19.
J Pharm Biomed Anal ; 37(2): 281-6, 2005 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-15708668

RESUMO

An original, simple and sensitive flow-injection spectroelectroanalytical method for the determination of chlorpromazine in pure form or in pharmaceutical formulations is described. The method is based on the formation of a stable cationic radical by electro-oxidation in sulfuric acid medium (0.1 mol l(-1)), monitored in situ at lambda=524 nm. The determination of chlorpromazine hydrochloride in pure form or in pharmaceutical formulations was explored, considering the amperometric and the absorptiometric signal. The association of these two signals enhanced the selectivity of the analysis and proved decisive when other electroactive compounds or excipients like ascorbic acid were present in the formulation. The analytical parameters have been evaluated and the results obtained using standard additions are in agreement with the reference methods.


Assuntos
Antipsicóticos/análise , Clorpromazina/análise , Análise de Injeção de Fluxo/métodos , Antipsicóticos/química , Ácido Ascórbico/química , Clorpromazina/química , Eletroquímica , Oxirredução , Ácidos Sulfúricos/química
20.
Free Radic Biol Med ; 75 Suppl 1: S41, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26461370

RESUMO

Air pollution is a major risk for human health. Acetaldehyde is an environmental pollutant present in tobacco smoke, vehicle exhaust and several food products. Formation of DNA adducts has been regarded as a critical factor in the mechanisms of acetaldehyde mutagenicity and carcinogenesis. Acetaldehyde reacts with 2'-deoxyguanosine in DNA to primarily form N(2)-ethylidene-2'-deoxyguanosine (N(2)-ethylidene-dGuo). The subsequent reaction of N(2)-ethylidene-dGuo with another molecule of acetaldehyde gives rise to 1,N(2)-propano-2´-deoxyguanosine (1,N(2)-propanodGuo). In this study, on-line reverse-phase high-performance liquid chromatography (HPLC) separation with tandem mass spectrometry detection was utilized for the accurate quantification of 1,N(2)-propanodGuo and 1,N(2)-etheno-2'-deoxyguanosine (1,N(2)-edGuo) in tissues of rats exposed to 12 ppb, 33 ppb and 96 ppb acetaldehyde in atmospheric air for 50 days. A significant increase in the levels of 1,N(2)-propanodGuo was observed in lung tissues of rats exposed to 12 ppb (7.8/10(8) dGuo); 33 ppb (8.9/10(8) dGuo) and 96 ppb (11.6/10(8) dGuo) compared to controls (4.2/10(8) dGuo). For comparative purposes, the levels of 1,N(2)-etheno-2'-deoxyguanosine (1,N(2)-edGuo), which is produced from a,b-unsaturated aldehydes formed during the lipid peroxidation process were also measured. Elevated levels of 1,N(2)-edGuo were observed only in lung tissues of animals exposed to 96 ppb acetaldehyde. 1,N(2)-propanodGuo also differed quantitatively in liver but not in brain. The monitoring of 1,N(2)-propanodGuo levels in tissues provides important information on acetaldehyde genotoxicity and may contribute to the elucidation of the mechanisms associated with acetaldehyde exposure and cancer risk. Supported byFAPESP:2011/10048-5, CAPES, INCT Redoxoma:573530/2008-4,NAP Redoxoma: 2011.1.9352.1.8, CEPID Redoxoma:2013/07937-8.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA