RESUMO
Congenital heart disease (CHD) is the most common birth defect, and up to 50% of infants with CHD require cardiovascular surgery early in life. Current clinical practice often involves thymus resection during cardiac surgery, detrimentally affecting T-cell immunity. However, epidemiological data indicate that CHD patients face an elevated risk for infections and immune-mediated diseases, independent of thymectomy. Hence, we examined whether the cardiac defect impacts thymus function in individuals with CHD. We investigated thymocyte development in 58 infants categorized by CHD complexity. To assess the relationship between CHD complexity and thymic function, we analyzed T-cell development, thymic output, and biomarkers linked to cardiac defects, stress, or inflammation. Patients with highly complex CHD exhibit thymic atrophy, resulting in low frequencies of recent thymic emigrants in peripheral blood, even prior to thymectomy. Elevated plasma cortisol levels were detected in all CHD patients, while high NT-proBNP and IL-6 levels were associated with thymic atrophy. Our findings reveal an association between complex CHD and thymic atrophy, resulting in reduced thymic output. Consequently, thymus preservation during cardiovascular surgery could significantly enhance immune function and the long-term health of CHD patients.
Assuntos
Cardiopatias Congênitas , Timo , Lactente , Humanos , Linfócitos T , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/patologia , Atrofia/patologiaRESUMO
BACKGROUND: Marfan syndrome (MFS) is associated with cardiovascular complications, particularly valvulopathies; however, its association with primary cardiomyopathy remains unclear. METHODS: This retrospective cohort study examined the cardiomyopathy characteristics (CMCs) in pediatric patients with MFS. CMCs were defined as meeting at least one of the following echocardiography or clinical parameters: (1) cardiac index (CI) too low for patient's age, (2) ejection fraction (EF) <50%, and (3) diastolic dysfunction. The predictive factors for CMCs were determined using a multivariable logistic regression model. RESULTS: Among 83 patients with MFS (age, median [range], 12.5 [0.4-22.3] years), 39.8% exhibited CMCs. Only 4 patients (5%) showed heart failure symptoms (NYHA > 1). Independent predictors for CMCs included a systemic score of ≥7 (revised Ghent criteria) and likely pathogenic or pathogenic variants in FBN1, including variants that introduce a premature stop codon, splice site variants, and missense variants involving cysteine. A multivariable score was constructed with an AUC of 0.733. CONCLUSION: This study offers valuable insights into the prevalence and predictors of CMC in pediatric patients with MFS and presents potential strategies for risk assessment of cardiomyopathy. IMPACT: The objective of this study was to elucidate the contentious issue of intrinsic cardiomyopathy in Marfan syndrome and demonstrate its notable occurrence even in pediatric patients who do not exhibit heart failure symptoms or valvular complications. We highlighted the importance of specific FBN1 variants and higher systemic scores in identifying the potential for intrinsic cardiomyopathy in pediatric patients with Marfan syndrome.
RESUMO
BACKGROUND: Adults with congenital heart defects (ACHD) globally constitute a notably medically underserved patient population. Despite therapeutic advancements, these individuals often confront substantial physical and psychosocial residua or sequelae, requiring specialized, integrative cardiological care throughout their lifespan. Heart failure (HF) is a critical challenge in this population, markedly impacting morbidity and mortality. AIMS: The primary aim of this study is to establish a comprehensive, prospective registry to enhance understanding and management of HF in ACHD. Named PATHFINDER-CHD, this registry aims to establish foundational data for treatment strategies as well as the development of rehabilitative, prehabilitative, preventive, and health-promoting interventions, ultimately aiming to mitigate the elevated morbidity and mortality rates associated with congenital heart defects (CHD). METHODS: This multicenter survey will be conducted across various German university facilities with expertise in ACHD. Data collection will encompass real-world treatment scenarios and clinical trajectories in ACHD with manifest HF or at risk for its development, including those undergoing medical or interventional cardiac therapies, cardiac surgery, inclusive of pacemaker or ICD implantation, resynchronization therapy, assist devices, and those on solid organ transplantation. DESIGN: The study adopts an observational, exploratory design, prospectively gathering data from participating centers, with a focus on patient management and outcomes. The study is non-confirmatory, aiming to accumulate a broad spectrum of data to inform future hypotheses and studies. PROCESSES: Regular follow-ups will be conducted, systematically collecting data during routine clinical visits or hospital admissions, encompassing alterations in therapy or CHD-related complications, with visit schedules tailored to individual clinical needs. ASSESSMENTS: Baseline assessments and regular follow-ups will entail comprehensive assessments of medical history, ongoing treatments, and outcomes, with a focus on HF symptoms, cardiac function, and overall health status. DISCUSSION OF THE DESIGN: The design of the PATHFINDER-CHD Registry is tailored to capture a wide range of data, prioritizing real-world HF management in ACHD. Its prospective nature facilitates longitudinal data acquisition, pivotal for comprehending for disease progression and treatment impacts. CONCLUSION: The PATHFINDER-CHD Registry is poised to offer valuable insights into HF management in ACHD, bridging current knowledge gaps, enhancing patient care, and shaping future research endeavors in this domain.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Insuficiência Cardíaca , Adulto , Humanos , Cardiopatias Congênitas/diagnóstico , Progressão da Doença , Sistema de Registros , Função VentricularRESUMO
BACKGROUND: In patients with tetralogy of Fallot (ToF) or ToF-like anatomy, factors possibly impacting the longevity of biological valves in the pulmonary position were investigated. METHOD: Between 1997 and 2017, 79 consecutive hospital survivors with a median age of 8.7 years (range: 0.2-56.1 years; interquartile range [IQR]: 14.8 years) with ToF or ToF-like anatomy underwent surgical implantation of Contegra (n = 34), Hancock (n = 23), Perimount (n = 9), pulmonary homograft (n = 9), and miscellaneous (n = 4) conduits. The median internal graft diameter was 19 mm (range: 11-29 mm; IQR: 8 mm) which refers to a median z-score of 0.6 standard deviation (SD) (range: -1.8 to 4.0 SD; IQR: 2.1 SD). RESULTS: The median time of follow-up was 9.4 years (range: 1.1-18.8 years; IQR: 6.0 years). Thirty-nine patients (49%) underwent surgical (n = 32) or interventional (n = 7) pulmonary valve re-replacement. Univariate Cox regression revealed patient age (p = 0.018), body surface area (p = 0.004), internal valve diameter (p = 0.005), and prosthesis z-score (p = 0.018) to impact valve longevity. Multivariate Cox regression analysis, however, did not show any significant effect (likely related to multicollinearity). Subgroup analysis showed that valve-revised patients have a higher average z-score (p = 0.003) and younger average age (p = 0.007). CONCLUSION: A decreased longevity of biological valves in the pulmonary position is related to younger age, lower valve diameter, and higher z-score. Because valve size (diameter and z-score) can be predicted by age, patient age is the crucial parameter influencing graft longevity.
Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Valva Pulmonar , Tetralogia de Fallot , Humanos , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Masculino , Feminino , Adulto , Adulto Jovem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Fatores de Tempo , Pessoa de Meia-Idade , Adolescente , Lactente , Fatores de Risco , Resultado do Tratamento , Criança , Pré-Escolar , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Estudos Retrospectivos , Fatores Etários , Falha de Prótese , Medição de Risco , ReoperaçãoRESUMO
Several criteria to identify suitable candidates for anatomic repair in congenitally corrected transposition (cc-TGA) have been proposed. The purpose of this study was to critically re-evaluate adequacy of these recommendations in our patient cohort. All cc-TGA patients undergoing anatomic repair between 2010 and 2019 were reviewed. Evaluated eligibility criteria for repair included age ≤ 15 years, LV mass index ≥ 45-50 g/m2, LV mass/volume ratio > 0.9-1.5 and systolic LV to right ventricle pressure ratio > 70-90% among others. Repair failure was defined as postoperative early mortality or LV dysfunction requiring mechanical circulatory support. Twenty-five patients were included (median [interquartile range] age at surgery 1.8 years [0.7;6.6]; median postoperative follow-up 3.2 years [0.7;6.3]). Median preoperative LV ejection fraction was 60% [56;64], indexed LV mass 48.5 g/m2 [43.7;58.1] and LV mass/volume ratio 1.5 [1.1;1.6], respectively. A total of 12 patients (48%) did not meet at least one of the previously recommended criteria, however, all but two patients (92%) experienced favorable early outcome. Of 7 patients (28%) with indexed LV mass < 45 g/m2, 6 were successfully operated. There were two early repair failures (8%) with LV dysfunction: one patient died and one required mechanical circulatory support but recovered well. Surgery was performed successfully in patients with LV mass and volume Z-scores as low as - 2 and - 2.5, respectively. Anatomic correction for cc-TGA can be performed with excellent early outcome and is feasible even in patients with LV mass below previously recommended cut-offs. The use of LV mass and volume Z-scores might help to refine eligibility criteria.
Assuntos
Transposição dos Grandes Vasos , Adolescente , Transposição das Grandes Artérias Corrigida Congenitamente , Humanos , Lactente , Volume Sistólico , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
BACKGROUND: The reconstruction of heart valves provides substantial benefits, particularly in the pediatric population. We present our experience using decellularized extracellular matrix (dECM, CorMatrix® ) for aortic valve procedures. METHODS: We retrospectively reviewed the case histories of 6 patients (aged from 2 months - 14 years) who underwent surgery for severe aortic valve stenosis (n = 4) or regurgitation (n = 2). Aortic valve repair was performed on all patients using dECM as a leaflet replacement or leaflet extension. Follow-ups were performed using echocardiography. Reoperation was necessary in 4 cases, and the dECM was explanted and examined histologically and immunohistochemically. RESULTS: The early post-operative period was uneventful, and the scaffold fulfilled the mechanical requirements. Significant valve insufficiency developed in 5 patients during the post-operative period (119-441 days postoperatively). In all specimens, only a migration of inflammatory cells was identified, which induced structural and functional changes caused by the chronic inflammatory response. CONCLUSIONS: Our results suggest a mixed immunological response of remodeling and inflammation following the implantation. The expected process of seeding/migration and remodeling of the bioscaffold into the typical 3-layered architecture were not observed in our explanted specimens.
Assuntos
Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Transplante Heterólogo , Resultado do Tratamento , Adolescente , Animais , Valva Aórtica/transplante , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Inflamação/etiologia , Masculino , Reoperação , Estudos Retrospectivos , Transplante Heterólogo/efeitos adversosRESUMO
Twenty-four percent of pediatric heart transplantations (pHTx) are carried out in infants. Neonatal heart transplantation is both rarely performed and challenging. We report on a newborn baby girl suffering from cardiac failure due to a huge tumor (24×52 mm) within the free wall of the left ventricle (LV) and subtotal obstruction of the main left bronchus. Following a surgical tumor resection, a Berlin Heart EXCOR left ventricular assist device was implanted as the bridge to the transplantation. In spite of an organ donor/recipient mismatch of >200%, both heart transplantation and the postoperative course were successful. In addition to this case report, the authors also present data from a survey on performed infant and neonatal transplantations in Western Europe. As neonatal heart transplantation is a rare event in Europe, the authors think it is of crucial importance to share this limited experience. We discuss an alternative strategy-namely, palliative surgical correction using the Fontan pathway. The challenges of donor/recipient weight mismatch and the possibilities of overcoming infant donor organ shortage as a postoperative immunosuppressive regimen are discussed as well.
Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Feminino , Coração Auxiliar , Humanos , Recém-Nascido , Suíça , Resultado do TratamentoRESUMO
OBJECTIVES: The aim of this study was to evaluate the effectiveness of balloon angioplasty (BAP) for recurrent aortic coarctation (ReCoA) in infants comparing simple and complex type of aortic arch pathology (Norwood I procedure). BACKGROUND: ReCoA is a known complication after cardiovascular surgery for coarctation of the aortic arch. METHODS AND RESULTS: In a single center case study, we analyzed 20 infants undergoing BAP for ReCoA comparing simple (n = 10) and complex type of aortic arch pathology (n = 10). At catherization diameter of ReCoA stenosis was 3.2 ± 0.7 mm (mean ± SD) with short localized (11/20) or long hypoplastic stenosis (9/20) before and 4.8 ± 1.2 mm after BAP (P < 0.001). Invasive systolic pressure gradient was reduced from 27.5 ± 16.2 mmHg before to 5.1 ± 6.6 mmHg after BAP (P < 0.001), comparable in simple and complex type of ReCoA. At day 1 after catherization noninvasive systolic arterial blood pressure gradient was reduced from 20.2 ± 23.1 to 6.7 ± 9.9 mmHg (P < 0.001), respectively, calculated continuous wave Doppler echo gradient from 36.3 ± 22 to 16.8 ± 9.6 mmHg (P < 0.01). Complications were aortic arch dissection (1/20), discrete aortic arch aneurysm formation (1/20), pericardial effusion (1/20), and peripheral arterial thrombosis (4/20). At a mid-term follow up of 9.5 months (1-40) after BAP, 3 infants needed early surgical reintervention due to secondary ReCoA, all with long hypoplastic aortic arch segments, but simple type of aortic arch pathology. CONCLUSIONS: At mid-term follow up, BAP remains an effective catheter intervention for ReCoA for infants with localized ReCoA, but not with long hypoplastic aortic arch segments, even in simple type of aortic arch pathology.
Assuntos
Angioplastia com Balão/métodos , Aorta Torácica , Coartação Aórtica , Procedimentos de Norwood , Complicações Pós-Operatórias , Prevenção Secundária/métodos , Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Coartação Aórtica/patologia , Coartação Aórtica/fisiopatologia , Coartação Aórtica/cirurgia , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Humanos , Lactente , Masculino , Procedimentos de Norwood/efeitos adversos , Procedimentos de Norwood/métodos , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Recidiva , Reoperação/métodos , SuíçaRESUMO
BACKGROUND AND AIM OF THE STUDY: An increasing number of young adult patients are choosing bioprostheses for aortic valve replacement (AVR). In this context, the Ross operation deserves renewed consideration as an alternative biological substitute. After both the Ross procedure and bioprosthetic AVR, reoperation rates remain a concern and may be related to age at surgery. Herein are reported details of freedom from reoperation after the Ross procedure for different age groups. METHODS: The reoperation rates of 1,925 patients (1,444 males, 481 females; mean age 41.2 ± 15.3 years) from the German Ross registry with a mean follow up of 7.4 ± 4.7 years (range: 0.00-18.51 years; total 12,866.6 patient-years) were allocated to three age groups: group I < 40 years; group II 40-60 years; and group III > 60 years. RESULTS: At 10 years (respectively 15 years) of follow up, freedom from reoperation was 86% (76%) in group I, 93% (85%) in group II, and 89% (83%) in group III. CONCLUSION: There is some evidence that, at least during the first 10 and 15 years after AVR, the Ross procedure provides a significantly lower reoperation rate in young adult and middle-aged patients aged < 60 years. This information may be of interest to the patients' or physicians' decision-making for aortic valve surgery.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas/cirurgia , Adulto , Bioprótese , Feminino , Alemanha , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Reoperação/estatística & dados numéricos , Adulto JovemRESUMO
Minimally invasive surgical closure of atrial septal defects is gaining widespread acceptance and can be performed via a right midaxillary thoracotomy. In addition, the procedure can be performed in ischaemic cardiac arrest or fibrillation with a core body temperature between 34°C and 36°C. OBJECTIVES: We present our single-centre results of paediatric patients who underwent surgical atrial septal defect II closure via lateral thoracotomy. METHODS: Retrospective analysis. Patients were divided into a cardiac arrest group and a cardiac fibrillation group. All procedures were performed via right midaxillary thoracotomy through a single incision without side ports. RESULTS: All 37 consecutive patients between March 2019 and August 2022 (median age 3 years; percentile 25th: 2; 75th: 5 years) in both groups were free of mortality and postoperative morbidity such as haemodynamically relevant residual shunt or malignant arrhythmias. Cardiopulmonary bypass time was significantly shorter in the fibrillation group (mean: 34.7 min vs 52.6 min, P = 0.01), and all patients were weaned off the ventilator immediately postoperatively. Length of the intensive care unit stay was not different between the 2 groups. Postoperative hospital stay was significantly longer in patients with cardiac arrest (mean: 5.6 days vs 4.9 days, P = 0.04). Postoperative laboratory parameters did not differ between the 2 groups. All patients were discharged with normal left ventricular function and normalized cardiac enzymes. CONCLUSIONS: Minimally invasive closure of an atrial septal defect during atrial fibrillation is a safe procedure with results comparable to those of an induced cardiac arrest procedure.
RESUMO
Objectives: A self-constructed valved pulmonary conduit made out of a de-cellularized porcine small intestinal submucosal extracellular matrix biological scaffold was tested in a chronic growing lamb model. Methods: The conduit was implanted in pulmonary valve position in 19 lambs. We monitored clinical, laboratory, and echocardiographic findings until 12 months after surgery. In two animals, euthanasia was planned at nine and twelve months. Pre-mortem chest computed tomography and post-mortem pathologic work up were performed. Data are presented as frequency and percentage, median and range, or mean and standard deviation. Results: Twelve (63.2%) animals survived the perioperative period. Three unexpected deaths occurred during the follow-up period: one due to aspiration pneumonia at 23 days after surgery, and two due to early and late infective endocarditis of the conduit at 18 and 256 days. In the two animals with planned scarification, the pre-mortem CT scan revealed mild or no calcification within the conduit or valve leaflets. In the echocardiographic examination at 12 months, peak and mean systolic pressure gradients across the conduit valve were 6.5 (3-21) mmHg and 3 (2-12) mmHg, while valve regurgitation was none (n = 2), trivial (n = 5), moderate (n = 1), or severe (n = 1). No clinical or laboratory signs of hemolysis were seen. After 12 months of follow-up, the animals' body weights had increased from 33 (27-38) kg to 53 (38-66) kg (p = 0.010). Conclusions: Implantation of a valved pulmonary conduit in our growing lamb model was feasible. Infective endocarditis of the implanted valved conduit remained a significant complication.
RESUMO
Comprehensive optimization of rotodynamic blood pumps (RBPs) requires the consideration of three partially conflicting objectives: size, hemocompatibility, and motor efficiency. Optimizing these individual objectives independently, the potential of multiobjective optimizations often remains untapped. This study aimed at the multiobjective optimization of an RBP for cavopulmonary support accounting for all three objectives simultaneously. Hydraulic and electromagnetic design spaces were characterized using computational fluid dynamics and computational electromagnetics, respectively. Design variables included secondary flow gap widths, impeller diameters, and stator heights. The size objective encompassed the RBP widths and heights, the hemocompatibility objective was a weighted composite measure of well-established metrics, and the motor objective was determined by motor losses. Multiobjective optimization was performed through Pareto analysis. 81 designs were considered, and 21 Pareto-optimal designs were identified. The Pareto analysis indicated that hemocompatibility performance could be improved by 72.4% with a concomitant 1.5% reduction in the baseline pump volume. This, however, entailed an increase in motor losses by 0.2 W, while still meeting design requirements, with maximum local temperature rises remaining below 0.4 K. The multiobjective optimization led to a Pareto front, demonstrating the feasibility to improve hemocompatibility at reduced pump volume, however, at the cost of a diminished yet still acceptable motor performance.
RESUMO
BACKGROUND: Marfan syndrome (MFS) guidelines recommend optimal pharmacologic therapy (OPT) and replacement of the ascending aorta (RAA) at 5.0 cm in diameter to prevent acute type A aortic dissection (ATAAD) and death. The effect of early MFS diagnosis and initiation of therapy on outcomes is not known. Therefore, we sought to evaluate the effect of age at MFS diagnosis and therapy initiation on delayed RAA and death. METHODS: This retrospective observational cohort study with long-term follow-up included consecutive patients with MFS, pathogenic FBN1 variant, and regular visits to a European Reference Network Center. We considered MFS diagnosis at age ≥21 years late and OPT initiation at age <21 years early. Outcomes were delayed RAA with aneurysm diameter >5.0 cm or ATAAD and death from all causes. We used landmark design starting at age 21 years to determine associations with outcomes. RESULTS: The study group consisted of 288 patients (45.1% male), including 169 patients with late diagnosis of MFS (58.7%) and 63 with early OPT (21.9%). During mean follow-up of 25 ± 14.7 years, 78 patients had delayed RAA, with 42 operations for ATAAD and 36 for aneurysms ≥5.0 cm. There were 33 deaths, including 11 deaths late after ATAAD. All deaths were cardiovascular. Late diagnosis, but not early OPT, showed univariate association with delayed RAA (P < .001) and death (P = .025). Multivariate Cox regression analysis confirmed late diagnosis as predictor of delayed RAA (hazard ratio, 8.01; 95% confidence interval, 2.52-25.45; P < .001) and death (hazard ratio, 4.68; 95% confidence interval, 1.17-18.80; P = .029). CONCLUSIONS: Late diagnosis of MFS is associated with delayed surgery and death.
Assuntos
Bioprótese/efeitos adversos , Veias Jugulares/transplante , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/patologia , Animais , Bovinos , Pré-Escolar , Evolução Fatal , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/patologia , Desenho de Prótese , Falha de PróteseRESUMO
Several device designs for cavopulmonary mechanical circulatory support (MCS) are under investigation, however, challenged by the Fontan population's heterogeneity in size, cardiovascular and thoracic anatomy. This study aimed to preclinically assess the anatomical compliance of proposed device designs in silico. Representative double- and single-outlet cavopulmonary assist device (CPAD) designs were virtually implanted into CT imaging data of 10 patients previously palliated with total cavopulmonary connection (TCPC) for functionally univentricular hearts. Anatomical device compatibility was characterized concerning pump proximity to cardiovascular, respiratory and thoracic structures, as well as pump in- and outflow graft configuration. In 10 Fontan patients with a median age of 10.4 years (interquartile range [IQR] 5.0-15.3 years) and a median body surface area of 1.09 m2 (IQR 0.76-1.28 m2), implantation of a double-outlet CPAD was feasible in 1 patient (10%). In all other, adverse device intersection with the trachea and (neo-)aorta, or posterior pulmonary artery outflow graft kinking were observed. A single-outlet design permitted enhanced device mobilization adapting to individual anatomical conditions, resulting in device fit in nine of 10 patients (90%). Despite vast anatomical variations among single ventricle patients, a single-outlet device design may provide intracorporeal cavopulmonary MCS to a broad spectrum of failing Fontan patients.
Assuntos
Aorta , Artéria Pulmonar , Humanos , Pré-Escolar , Criança , Adolescente , Superfície Corporal , Cooperação do Paciente , PacientesRESUMO
Both single- and double-outflow cavopulmonary assist devices (CPADs) were recently proposed for the Fontan population, whereas single-outflow configurations were evaluated in large animal trials and double-outflow concepts are lacking an equivalent in vivo assessment. The aim of this study was to test the hemodynamic properties of a double-outflow CPAD device in an acute sheep model. The two inflow cannulae of a CPAD were anastomosed to the caval veins. Outflow graft connection was performed via end-to-side anastomosis to the right (RPA) and main pulmonary artery (MPA). Speed ramp protocols were conducted, and hemodynamic effects were monitored in terms of caval flows, cardiac output (CO), central venous pressure (CVP), pulmonary artery pressure (PAP), and left atrial pressure (LAP). Six experiments were conducted (53.35 ± 5.1 kg). In three experiments, the animal model was established, the CPAD was examined, and restoration of biventricular equivalency in terms of venous return was achieved. Venous pressures (CVP) declined linearly with increasing pump speed (r > 0.879), whereas caval flow (r > 0.973), CO (r > 0.993), PAP (r > 0.973), and LAP (r > 0.408) increased. Despite the considerable complexity of the sheep model caused by the sheep pulmonary arterial anatomy that requires substantial graft bending, the CPAD was evaluated in three acute experiments and showed the potential to completely substitute a subpulmonary ventricle.
Assuntos
Técnica de Fontan , Coração Auxiliar , Animais , Ovinos , Estudos de Viabilidade , Artéria Pulmonar/cirurgia , Hemodinâmica , Modelos AnimaisRESUMO
The mid-aortic syndrome is an uncommon clinical condition characterized by severe narrowing of the descending aorta, usually with involvement of its renal and visceral branches, presenting with uncontrollably elevated blood pressures of the upper body, renal and cardiac failure, intestinal ischemia, encephalopathy symptoms and claudication of the lower limbs, although clinical presentation is variable. In this article we report the case of an eleven-year-old patient with the initial diagnosis of a mid-aortic syndrome and present the computed tomography angiography pictures and reconstructions before and after surgical therapy.
Assuntos
Aorta Torácica/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Aortografia/métodos , Circulação Colateral , Tomografia Computadorizada por Raios X , Aorta Torácica/fisiopatologia , Aorta Torácica/cirurgia , Coartação Aórtica/complicações , Coartação Aórtica/fisiopatologia , Coartação Aórtica/cirurgia , Pressão Sanguínea , Implante de Prótese Vascular , Criança , Humanos , Masculino , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Resultado do TratamentoRESUMO
We present a patient with severe tracheal stenosis resulting from a compression by the innominate artery 6 months after an arterial switch operation in a dextro-transposition of the great arteries. Segmentation and three-dimensional (3D) visualization were derived from a contrast-enhanced dual-source computed tomography and post-processing was performed using a dedicated open-source platform (3D Slicer). Post-processing allowed a comprehensible visualization of the relationship of the innominate artery to the trachea when compared to standard computer tomography reformations. Finally, the surgical approach to move the innominate artery anteriorly in order to relieve the tracheal obstruction was emphasized based on the improved 3D visualization of the actual pathology. An effective aortopexy could be performed and the postoperative result was confirmed by a second 3D visualization. About 3 months of follow-up, the patient is completely asymptomatic. Three-dimensional visualization offers excellent opportunities for diagnosis, treatment planning and follow-up in patients with a vascular-related tracheal stenosis in the context of congenital heart disease.