Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(6): 340, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801642

RESUMO

BACKGROUND: Pediatric rotary file systems were developed to solve manual file limitations. With many systems available, it may be tricky to select the most appropriate one. AIM: to assess & compare Kedo-S Square, Fanta-AF™-Baby rotary files with manual K-file concerning removed dentin amount, canal transportation, centric ability & root canal taper using CBCT in primary anterior teeth. DESIGN: Extracted Seventy-five upper primary anterior teeth with intact 2/3 root length were collected and divided into three groups based on root canal instrumentation, group-I: prepared using K-file, group-II: prepared using Kedo-S Square, and group-III: prepared using Fanta AF™ Baby file. The teeth were imaged with CBCT before & following canal instrumentation. Then, the removed dentin amount was calculated at each root-canal level. The Kruskal-Wallis test was utilized to statistically analyze study data. RESULT: The difference among the three groups was highly statistically significant at cervical & apical thirds concerning dentin thickness changes on both mesial & distal sides following canal preparation with the least removed dentin in the Kedo-S Square group(P < 0.0001). Regarding transportation & centering ability, a non-significant difference between the three groups was found. 80% of the Fanta AF™ Baby group had good-tapered preparation compared to the Kedo-S Square (72%) and K-file (40%) groups(P < 0.05). CONCLUSION: Kedo-S Square was preferable to Fanta-AFTM-Baby & manual K-files in primary root canal preparation.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Desenho de Equipamento , Preparo de Canal Radicular , Dente Decíduo , Humanos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Técnicas In Vitro , Dente Decíduo/diagnóstico por imagem , Incisivo/diagnóstico por imagem , Instrumentos Odontológicos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/cirurgia
2.
Clin Oral Investig ; 27(12): 7395-7405, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37864602

RESUMO

OBJECTIVES: The complex root canal anatomy of primary teeth keeps it very tricky to attain appropriate cleansing by biomechanical instrumentation, so obtaining an obturating material with excellent antimicrobial properties is a challenge in current clinical pulpectomy practice. So, this study aimed to assess the clinical and radiographic performance of zinc oxide-ozonated olive oil as a primary root canal filling material. MATERIALS AND METHODS: Ninety non-vital primary molars in children ranging from 4 to 8 years were allocated into three groups in which root canals were filled with zinc oxide-ozonated olive oil, zinc oxide-olive oil, and zinc oxide-eugenol (ZOE) according to each group after pulpectomy procedure. Clinical and radiographic evaluations were done at 3-, 6-, and 12-month follow-up periods. Statistical analysis was performed for the collected data. RESULTS: All study groups showed a significant improvement regarding clinical signs and symptoms during follow-up periods. Ozonated-olive oil group revealed a significant increase in furcation radiodensity and a decrease in periodontal ligament space at 3-, 6-, and 12-month follow-up intervals compared to other groups. CONCLUSION: Zinc oxide-ozonated olive oil and zinc oxide-olive oil paste had shown good clinical and radiographic success for primary teeth pulpectomy. CLINICAL RELEVANCE: The intricate torturous primary root canal anatomy, in addition to the child's negative behavior, interferes with the complete debridement, so the long-lasting antibacterial effect of the primary root canal filling material aids in the pulpectomy success.


Assuntos
Materiais Restauradores do Canal Radicular , Óxido de Zinco , Criança , Humanos , Dente Molar/cirurgia , Azeite de Oliva , Pulpectomia/métodos , Materiais Restauradores do Canal Radicular/farmacologia , Dente Decíduo , Óxido de Zinco/farmacologia , Cimento de Óxido de Zinco e Eugenol/farmacologia , Pré-Escolar
3.
BMC Oral Health ; 23(1): 687, 2023 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-37742023

RESUMO

INTRODUCTION: The success of primary teeth pulpectomy is strongly reliant on instrumentation techniques and their impact on obturation quality & postoperative pain. Recently, pediatric rotary file systems have been implemented. AIM: to compare two pediatric rotary file systems (Kedo-S-Square & Fanta AF™ Baby) with manual K-files concerning obturation quality, instrumentation time, and postoperative pain in root canal preparation of primary molars using cone beam computed tomography (CBCT). METHODS: A randomized clinical trial was conducted with the trial registration number (TRN: NCT05619796 and date of registration: (17/11/2022) on sixty primary lower 2nd molars in healthy children aged 4-7 years. Molars were assigned randomly to three groups (n = 20). Group-I and -II were prepared with Kedo-S-Square & Fanta AF™Baby rotary systems respectively while group-III was prepared with a manual K-file. Instrumentation time was recorded using a stopwatch. CBCT was used to assess obturation quality immediately & recorded as optimal, underfilled, or overfilled. Postoperative pain was evaluated at 6, 12, 24, 48 h-time intervals using a four-point pain intensity scale. Statistical analysis was performed for the collected data. RESULTS: Among the three groups, group-I revealed a greater number of optimally filled teeth (85%) & less instrumentation time (74.75 s) followed by group-II & manual-K file group (p < 0.05). The hand K-file group had significantly more postoperative pain than the two rotary groups (p < 0.05). CONCLUSION: the tested rotary file systems resulted in better obturation quality, less instrumentation time, and less postoperative pain compared to manual-K files during primary teeth pulpectomy.


Assuntos
Preparo de Canal Radicular , Dente Decíduo , Criança , Humanos , Pulpectomia , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Dor Pós-Operatória
4.
Sci Rep ; 14(1): 18640, 2024 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-39128909

RESUMO

Rehabilitation of pulpotomized primary molars with an appropriate restoration is essential for recovering function and safeguarding the durability of the treatment. This study aimed to assess and compare the surface roughness of stainless steel (ST) crowns, zirconia (ZR) crowns, fiberglass (FG) crowns, and lithium disilicate (LD) endo-crowns as a restoration for pulpotomized primary molars also, evaluating the surface roughness of their antagonists. Sixty pulpotomized primary mandibular first molars were used for qualitative surface roughness evaluation and divided into four groups (n = 15/group) according to the crown type (group-ST, group-ZR, group-FG, group-LD). While the other sixty sound, unprepared primary maxillary first molars were used for evaluation of their surface roughness against the tested crowns. Specimens' preparation and cementation were carried out according to each crown type and manufacturer's instructions. The surface roughness was done using a two-body wear test. The data were statistically analyzed. All tested crowns showed an increased change in surface roughness, except group-ZR, which had the least change in surface roughness after mechanical wear with no statistically significant difference(P = 0.681). All crown types significantly increased the surface roughness of their antagonists after mechanical wear, except group-ST which showed insignificant affection (p ≥ 0.05). Zirconia crowns and lithium disilicate endo-crowns had the least change in surface roughness compared to other groups while SSCs showed the least tooth loss in the antagonist enamel.


Assuntos
Coroas , Porcelana Dentária , Dente Molar , Propriedades de Superfície , Dente Decíduo , Zircônio , Porcelana Dentária/química , Humanos , Zircônio/química , Aço Inoxidável/química , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA