Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 220(1): 73-85, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35731096

RESUMO

BACKGROUND. Anatomic redundancy between phases can be used to achieve denoising of multiphase CT examinations. A limitation of iterative reconstruction (IR) techniques is that they generally require use of CT projection data. A frequency-split multi-band-filtration algorithm applies denoising to the multiphase CT images themselves. This method does not require knowledge of the acquisition process or integration into the reconstruction system of the scanner, and it can be implemented as a supplement to commercially available IR algorithms. OBJECTIVE. The purpose of the present study is to compare radiologists' performance for low-contrast and high-contrast diagnostic tasks (i.e., tasks for which differences in CT attenuation between the imaging target and its anatomic background are subtle or large, respectively) evaluated on multiphase abdominal CT between routine-dose images and radiation dose-reduced images processed by a frequency-split multiband-filtration denoising algorithm. METHODS. This retrospective single-center study included 47 patients who underwent multiphase contrast-enhanced CT for known or suspected liver metastases (a low-contrast task) and 45 patients who underwent multiphase contrast-enhanced CT for pancreatic cancer staging (a high-contrast task). Radiation dose-reduced images corresponding to dose reduction of 50% or more were created using a validated noise insertion technique and then underwent denoising using the frequency-split multi-band-filtration algorithm. Images were independently evaluated in multiple sessions by different groups of abdominal radiologists for each task (three readers in the low-contrast arm and four readers in the high-contrast arm). The noninferiority of denoised radiation dose-reduced images to routine-dose images was assessed using the jackknife alternative free-response ROC (JAFROC) figure-of-merit (FOM; limit of noninferiority, -0.10) for liver metastases detection and using the Cohen kappa statistic and reader confidence scores (100-point scale) for pancreatic cancer vascular invasion. RESULTS. For liver metastases detection, the JAFROC FOM for denoised radiation dose-reduced images was 0.644 (95% CI, 0.510-0.778), and that for routine-dose images was 0.668 (95% CI, 0.543-0.792; estimated difference, -0.024 [95% CI, -0.084 to 0.037]). Intraobserver agreement for pancreatic cancer vascular invasion was substantial to near perfect when the two image sets were compared (κ = 0.53-1.00); the 95% CIs of all differences in confidence scores between image sets contained zero. CONCLUSION. Multiphase contrast-enhanced abdominal CT images with a radiation dose reduction of 50% or greater that undergo denoising by a frequency-split multiband-filtration algorithm yield performance similar to that of routine-dose images for detection of liver metastases and vascular staging of pancreatic cancer. CLINICAL IMPACT. The image-based denoising algorithm facilitates radiation dose reduction of multiphase examinations for both low- and high-contrast diagnostic tasks without requiring manufacturer-specific hardware or software.


Assuntos
Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Skeletal Radiol ; 50(1): 149-157, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32691125

RESUMO

OBJECTIVE: To evaluate a new adaptive iterative metal artifact reduction algorithm (AiMAR) in whole-body low-dose CT (WBLDCT) skeletal survey examinations. METHODS: Projection data were retrospectively obtained from 25 clinical WBLDCT skeletal survey patients, each with two types of metal implants. Images were reconstructed with bone and soft tissue kernels using four settings-original and AiMAR with strengths of 2, 4, and 5. All images were anonymized and randomized for a reader study, where three musculoskeletal radiologists independently determined the overall ranking of all series based on diagnostic quality, and local scoring of metal artifact and anatomy visualization for each implant. Quantitative image noise analysis was performed in areas close to the implants. Intraclass correlation coefficients (ICC) and Krippendorff's alpha were computed for inter-rater reliability. RESULTS: AiMAR 4 was ranked the highest for 64.3% of the series across eight types of implants. For local scoring task, AiMAR 4 showed better metal artifact and anatomy visualization than the original and AiMAR 2. AiMAR 4 was comparable in anatomy visualization but inferior to AiMAR 5 in metal artifact scores. AiMAR 4 led to 56.3% noise reduction around the implant areas compared with the original images, and AiMAR 5 68.1% but also resulted in anatomy blurring in 40% of the implants. ICC and Krippendorff's alpha revealed at least substantial reliability in the local scores among the readers. CONCLUSIONS: AiMAR was evaluated in WBLDCT skeletal surveys. AiMAR 4 demonstrated the highest overall quality ranking and improved local scores with noise reduction around implant areas.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Próteses e Implantes , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Vascular ; 29(6): 927-937, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33459205

RESUMO

OBJECTIVE: This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. METHODS: After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into "not opacified", "<50% stenosis", " 50 ̶70% stenosis", ">70% stenosis", and "occluded" for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. RESULTS: Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8-32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively (p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus (p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) (p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients (p = 0.319), respectively. CONCLUSION: Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Iohexol/administração & dosagem , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Índice de Gravidade de Doença
4.
Radiographics ; 39(3): 729-743, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31059394

RESUMO

Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.


Assuntos
Fótons , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste , Desenho de Equipamento , Humanos , Compostos de Iodo , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/tendências
5.
J Comput Assist Tomogr ; 43(4): 612-618, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31268876

RESUMO

OBJECTIVE: The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. METHODS: The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. RESULTS: The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. CONCLUSION: The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.


Assuntos
Abdome , Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Meios de Contraste , Iodo , Abdome/irrigação sanguínea , Abdome/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Meios de Contraste/administração & dosagem , Meios de Contraste/uso terapêutico , Humanos , Iodo/administração & dosagem , Iodo/uso terapêutico , Masculino , Radiografia Abdominal , Estudos Retrospectivos , Fatores de Tempo
6.
Radiology ; 289(2): 436-442, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30084728

RESUMO

Purpose To compare a research photon-counting-detector (PCD) CT scanner to a dual-source, dual-energy CT scanner for the detection and characterization of renal stones in human participants with known stones. Materials and Methods Thirty study participants (median age, 61 years; 10 women) underwent a clinical renal stone characterization scan by using dual-energy CT and a subsequent research PCD CT scan by using the same radiation dose (as represented by volumetric CT dose index). Two radiologists were tasked with detection of stones, which were later characterized as uric acid or non-uric acid by using a commercial dual-energy CT analysis package. Stone size and contrast-to-noise ratio were additionally calculated. McNemar odds ratios and Cohen k were calculated separately for all stones and small stones (≤3 mm). Results One-hundred sixty renal stones (91 stones that were ≤ 3 mm in axial length) were visually detected. Compared with 1-mm-thick routine images from dual-energy CT, the odds of detecting a stone at PCD CT were 1.29 (95% confidence interval: 0.48, 3.45) for all stones. Stone segmentation and characterization were successful at PCD CT in 70.0% (112 of 160) of stones versus 54.4% (87 of 160) at dual-energy CT, and was superior for stones 3 mm or smaller at PCD CT (45 vs 25 stones, respectively; P = .002). Stone characterization agreement between scanners for stones of all sizes was substantial (k = 0.65). Conclusion Photon-counting-detector CT is similar to dual-energy CT for helping to detect renal stones and is better able to help characterize small renal stones. © RSNA, 2018.


Assuntos
Cálculos Renais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Fótons , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação
7.
J Appl Clin Med Phys ; 19(4): 252-260, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29749048

RESUMO

OBJECTIVES: Both projection and dual-energy (DE)-based methods have been used for metal artifact reduction (MAR) in CT. The two methods can also be combined. The purpose of this work was to evaluate these three MAR methods using phantom experiments for five types of metal implants. MATERIALS AND METHODS: Five phantoms representing spine, dental, hip, shoulder, and knee were constructed with metal implants. These phantoms were scanned using both single-energy (SE) and DE protocols with matched radiation output. The SE data were processed using a projection-based MAR (iMAR, Siemens) algorithm, while the DE data were processed to generate virtual monochromatic images at high keV (Mono+, Siemens). In addition, the DE images after iMAR were used to generate Mono+ images (DE iMAR Mono+). Artifacts were quantitatively evaluated using CT numbers at different regions of interest. Iodine contrast-to-noise ratio (CNR) was evaluated in the spine phantom. Three musculoskeletal radiologists and two neuro-radiologists independently ranked the artifact reduction. RESULTS: The DE Mono+ at high keV resulted in reduced artifacts but also lower iodine CNR. The iMAR method alone caused missing tissue artifacts in dental phantom. DE iMAR Mono+ caused wrong CT numbers in close proximity to the metal prostheses in knee and hip phantoms. All musculoskeletal radiologists ranked SE iMAR > DE iMAR Mono+ > DE Mono+ for knee and hip, while DE iMAR Mono+ > SE iMAR > DE Mono+ for shoulder. Both neuro-radiologists ranked DE iMAR Mono+ > DE Mono+ > SE iMAR for spine and DE Mono+ > DE iMAR Mono+ > SE iMAR for dental. CONCLUSIONS: The SE iMAR was the best choice for the hip and knee prostheses, while DE Mono+ at high keV was best for dental implants and DE iMAR Mono+ was best for spine and shoulder prostheses. Artifacts were also introduced by MAR algorithms.


Assuntos
Artefatos , Algoritmos , Humanos , Metais , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
8.
Acta Oncol ; 56(11): 1465-1471, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28885130

RESUMO

PURPOSE: To evaluate the accuracy and precision across phantom size of a dual-energy computed tomography (DECT) technique used to calculate relative proton stopping power (SPR) in tissue-simulating materials and a silicone implant relative to conventional single-energy CT (SECT). MATERIAL AND METHODS: A 32 cm lateral diameter (CIRS model 062M, Norfolk, Virginia) electron density phantom containing inserts which simulated the chemical composition of eight tissues in a solid-water background was scanned using SECT and DECT. A liquid water insert was included to confirm CT number accuracy. All materials were also placed in four water tanks, ranging from 15 to 45 cm in lateral width and scanned using DECT and SECT. A silicone breast implant was scanned in the same water phantoms. SPR values were calculated based on commercial software (syngo CT Dual Energy, Siemens Healthcare GmbH) and compared to reference values derived from proton beam measurements. Accuracy and precision were quantified across phantom size using percent error and standard deviation. Graphical and regression analysis were used to determine whether SECT or DECT was superior in estimating SPR across phantom size. RESULTS: Both DECT and SECT SPR data resulted in good agreement with the reference values. Percent error was ±3% for both DECT and SECT in all materials except lung and dense bone. The coefficient of variation (CV) across materials and phantom sizes was 1.12% for SECT and 0.96% for DECT. Material-specific regression and graphical analysis did not reveal size dependence for either technique but did show reduced systematic bias with DECT for dense bone and liver. Mean percent error in SPR for the implant was reduced from 11.46% for SECT to 0.49% for DECT. CONCLUSIONS: We demonstrate the superior ability of DECT to mitigate systematic bias in bones and liver and estimate SPR in a silicone breast implant.


Assuntos
Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Prótons , Tomografia Computadorizada por Raios X/métodos , Relação Dose-Resposta à Radiação , Humanos
9.
J Comput Assist Tomogr ; 40(4): 663-70, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27096399

RESUMO

PURPOSE: A research photon-counting computed tomography (CT) system that consists of an energy-integrating detector (EID) and a photon-counting detector (PCD) was installed in our laboratory. The scanning fields of view of the EID and PCD at the isocenter are 500 and 275 mm, respectively. When objects are larger than the PCD scanning field of view, a data-completion scan (DCS) using the EID subsystem is needed to avoid truncation artifacts in PCD images. The goals of this work were to (1) find the impact of a DCS on noise of PCD images and (2) determine the lowest possible dose for a DCS such that truncation artifacts are negligible in PCD images. METHODS: First, 2 semianthropomorphic abdomen phantoms were scanned on the PCD subsystem. For each PCD scan, we acquired 1 DCS with the maximum effective mAs and 5 with lower effective mAs values. The PCD image reconstructed using the maximum effective mAs was considered as the reference image, and those using the lower effective mAs as the test images. The PCD image reconstructed without a DCS was considered the baseline image. Each PCD image was assessed in terms of noise and CT number uniformity; the results were compared among the baseline, test, and reference images. Finally, the impact of a DCS on PCD image quality was qualitatively assessed for other body regions using an anthropomorphic torso phantom. RESULTS: The DCS had a negligible impact on the noise magnitude in the PCD images. The PCD images with the minimum available dose (CTDIvol < 2 mGy) showed greatly enhanced CT number uniformity compared with the baseline images without noticeable truncation artifacts. Further increasing the effective mAs of a DCS did not yield noticeable improvement in CT number uniformity. CONCLUSIONS: A DCS using the minimum available dose had negligible effect on image noise and was sufficient to maintain satisfactory CT number uniformity for the PCD scans.


Assuntos
Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Imagem Corporal Total/instrumentação , Contagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Fótons , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Contagem Corporal Total/métodos
10.
AJR Am J Roentgenol ; 205(6): 1203-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26587926

RESUMO

OBJECTIVE: The purpose of this phantom study was to determine the utility of a third-generation dual-source CT scanner with increased dual-energy spectral separation in differentiating urinary stone composition. MATERIALS AND METHODS: Eighty-seven urinary stones from humans were scanned in 35-, 40-, 45-, and 50-cm wide anthropomorphic phantoms with a third-generation dual-source scanner (system A) with a high-energy beam of 150 kV plus 0.6-mm tin filtration (Sn). The low-energy data were acquired at 70, 80, 90, and 100 kV. A second-generation dual-source scanner (system B) was used to acquire data at 140 kV plus 0.4-mm Sn for the high-energy and 80 or 100 kV for the low-energy images. Volume CT dose index was matched for a given phantom size. CT number ratios were calculated and used to differentiate uric acid from non-uric acid stones and oxalate from apatite stones in an ROC analysis. RESULTS: The area under the curve (AUC) of the ROC curve for uric acid versus non-uric acid stones increased for large phantoms. For example, for imaging of the 45-cm wide phantom with system A at the 100- and 150-kV Sn low- and high-energy combination, the AUC was 0.99, whereas for system B at the 100- and 140-kV Sn combination, the AUC was 0.86. At each phantom size and for all energy combinations, the AUC values for oxalate versus apatite stones were higher for system A than they were for any energy combination for system B. CONCLUSION: Compared with use of second-generation dual-source CT, use of third-generation dual-source CT at the energy combination of 100 and 150 kV Sn improved classification of urinary stones across a wide range of phantom sizes and increased the ability to differentiate oxalate from apatite stones.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/química , Cálculos Urinários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador
11.
J Magn Reson Imaging ; 39(3): 735-41, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24123760

RESUMO

PURPOSE: To evaluate the use of a modular MRI conditional respiratory monitoring and gating solution, designed to facilitate proper monitoring of subjects' vital signals and their respiratory efforts, during free-breathing and breathheld 19F, oxygen-enhanced, and Fourier-decomposition MRI-based acquisitions. MATERIALS AND METHODS: All Imaging was performed on a Siemens TIM Trio 3 Tesla MRI scanner, following Institutional Review Board approval. Gas delivery is accomplished through the use of an MR compatible pneumotachometer, in conjunction with two three-way pneumatically controlled Hans Rudolph Valves. The pneumatic valves are connected to Douglas bags used as the gas source. A mouthpiece (+nose clip) or an oro-nasal Hans Rudolph disposable mask is connected following the pneumatic valve to minimize dead-space and provide an airtight seal. Continuous monitoring/sampling of inspiratory and expiratory oxygen and carbon dioxide levels at the mouthpiece/mask is achieved through the use of an Oxigraf gas analyzer. RESULTS: Forty-four imaging sessions were successfully monitored, during Fourier-decomposition (n=3), fluorine-enhanced (n=29), oxygen-enhanced, and ultra short echo (n=12) acquisitions. The collected waveforms, facilitated proper monitoring and coaching of the subjects. CONCLUSION: We demonstrate an inexpensive, off-the-shelf solution for monitoring these signals, facilitating assessments of lung function. Monitoring of respiratory efforts and exhaled gas concentrations assists in understanding the heterogeneity of lung function visualized by gas imaging.


Assuntos
Asma/diagnóstico , Fibrose Cística/diagnóstico , Imageamento por Ressonância Magnética , Monitorização Fisiológica/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Testes de Função Respiratória/métodos , Adolescente , Adulto , Idoso , Estudos de Coortes , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Troca Gasosa Pulmonar , Valores de Referência , Testes de Função Respiratória/instrumentação , Mecânica Respiratória , Fenômenos Fisiológicos Respiratórios , Adulto Jovem
12.
Radiology ; 267(3): 747-56, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23192773

RESUMO

PURPOSE: To compare measurements of regional pulmonary perfused blood volume (PBV) and pulmonary blood flow (PBF) obtained with computed tomography (CT) in two pig models. MATERIALS AND METHODS: The institutional animal care and use committee approved all animal studies. CT-derived PBF and PBV were determined in four anesthetized, mechanically ventilated, supine swine by using two methods for creating pulmonary parenchymal perfusion heterogeneity. Two animals were examined after sequentially moving a pulmonary arterial balloon catheter from a distal to a central location, and two others were examined over a range of static airway pressures, which varied the extents of regional PBF. Lung sections were divided into blocks and Pearson correlation coefficients calculated to compare matching regions between the two methods. RESULTS: CT-derived PBF, CT-derived PBV, and their associated coefficients of variation (CV) were closely correlated on a region-by-region basis in both the balloon occlusion (Pearson R = 0.91 and 0.73 for animals 1 and 2, respectively; Pearson R = 0.98 and 0.87 for comparison of normalized mean and CV for animals 1 and 2, respectively) and lung inflation studies (Pearson R = 0.94 and 0.74 for animals 3 and 4, respectively; Pearson R = 0.94 and 0.69 for normalized mean and CV for animals 3 and 4, respectively). When accounting for region-based effects, correlations remained highly significant at the P < .001 level. CONCLUSION: CT-derived PBV heterogeneity is a suitable surrogate for CT-derived PBF heterogeneity.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Volume Sanguíneo/fisiologia , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Animais , Meios de Contraste/administração & dosagem , Iopamidol/administração & dosagem , Modelos Animais , Suínos
13.
Radiology ; 268(2): 572-80, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23592768

RESUMO

PURPOSE: To evaluate the effects of lung volume differences on apparent diffusion coefficient (ADC) measurements on a regional basis, with breath holds at volumes adjusted for differences in lung size across individuals according to the subject's vital capacity (VC). MATERIALS AND METHODS: This study was approved by the local institutional review board and was compliant with HIPAA. Informed consent was obtained from all subjects. Imaging was performed under a physician's Investigational New Drug application from the Food and Drug Administration. ADC changes as a function of inflation levels were evaluated in 24 healthy never-smokers across three lung volumes (20%, 60%, and 100% VC) on the basis of the spirometric data collected from each subject. Response variables based on lung volume and anatomic position were assessed with multifactorial analysis of variance followed by posthoc pair-wise testing. Imaging was performed with a 1.5-T magnetic resonance (MR) unit with use of a two-dimensional gradient-echo fast low-angle shot sequence. RESULTS: Significant differences in ADCs between lung volumes were observed for all inflation levels (20%, 60%, and 100% VC; P < .001), along with significant dependent-nondependent vertical gradients at 20% VC (P < .0001) and 60% VC (P < .0001, left lung only). In addition, significant differences between mean values in the left and right lungs with respect to those in the whole lung were observed at the lower lung inflation levels (20% and 60% VC, P < .01), reaching more uniform expansion at 100% VC. CONCLUSION: The results confirm known anatomic differences in patterns of regional inflation and ventilation with corresponding lung volume changes, emphasizing the need for tight control over lung volume when performing hyperpolarized helium 3 ((3)He) lung studies if (3)He MR imaging is to be used to follow up small longitudinal changes in lung abnormalities.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Pulmão/fisiologia , Adulto , Idoso , Análise de Variância , Feminino , Hélio , Humanos , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Espirometria , Capacidade Vital
14.
Abdom Radiol (NY) ; 47(6): 2158-2167, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35320381

RESUMO

PURPOSE: To compare the utility of a novel metal artifact reduction algorithm to standard imaging in improving visualization of key structures, diagnostic confidence, and patient-level confidence in malignancy in patients with suspected bladder cancer. METHODS: Patients with hip implants undergoing CT urography for suspected bladder malignancy were enrolled. Images were reconstructed using 3 methods: (1) Filtered Back Projection (FBP), (2) Iterative Metal Artifact Reduction (iMAR), and (3) Adaptive Iterative Metal Artifact Reduction (AiMAR) strength 4. In multiple reading sessions, three radiologists graded visualization of critical anatomic structures and artifact severity (6-point scales, lower scores desirable), and diagnostic confidence in blinded fashion. They also graded patient-level confidence in malignancy based on imaging findings in each patient. RESULTS: Thirty-two patients (8 females) with a mean age of 74.5 ± 8.5 years were included. The median (range) visualization scores for FBP, iMAR, and AiMAR were 3.6 (1.1-4.9), 1.6 (0.3-2.8), and 1.6 (0.3-2.6), respectively. Both iMAR and AiMAR had anatomic visualization and artifact scores better than FBP (P < 0.001 for both) and similar to each other (P > 0.05). Structures with the most improvement in visualization score with the use of metal artifact reduction algorithms included the obturator internus muscle, internal and external iliac nodal chains, and vagina. iMAR and AiMAR improved diagnostic confidence (P < 0.001) and patient-level confidence in malignancy (P ≤ 0.24). CONCLUSION: For patients with hip prostheses and suspected bladder malignancy, the use of iMAR or AiMAR was shown to significantly reduce metal artifacts, thus improving diagnostic confidence and patient-level confidence in malignancy.


Assuntos
Prótese de Quadril , Neoplasias da Bexiga Urinária , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Feminino , Humanos , Masculino , Metais , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem
15.
Med Phys ; 48(9): 4857-4871, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33988849

RESUMO

PURPOSE: Multi-energy computed tomography (MECT) has a great potential to enable many novel clinical applications such as simultaneous multi-contrast imaging. The purpose of this study was to implement triple-beam MECT on a traditional energy-integrating-detector (EID) CT platform (EID-MECT). METHODS: This was accomplished by mounting a z-axis split-filter (0.05 mm Au, 0.6 mm Sn) on Tube A of a dual-source EID CT scanner. With the two split x-ray beams from Tube A and the third beam from Tube B, three beams with different x-ray spectra can be simultaneously acquired. With Tube B operated at 70 or 80 kV and Tube A at 120 or 140 kV, four different triple-beam configurations were calibrated for MECT measurements: 70/Au120/Sn120, 80/Au120/Sn120, 70/Au140/Sn140, and 80/Au140/Sn140 kV. Iodine (I), gadolinium (Gd), bismuth (Bi) samples, and their mixtures were prepared for 2 three-material-decomposition tasks and 1 four-material-decomposition task. For each task, samples were placed in a water phantom and scanned using each of the four triple-beam configurations. For comparison, the same phantom was also scanned using three other dual-energy CT (DECT) or MECT technologies: twin-beam DECT (TB-DECT), dual-source DECT (DS-DECT), and photon-counting-detector CT (PCD-CT), all with optimal x-ray spectrum settings and at equal volume CT dose index (CTDIvol). The phantom for four-material decomposition (I/Gd/Bi/Water imaging) was scanned using the PCD-CT only (140 kV with 25, 50, 75, and 90 keV). Image-based material decomposition was performed to acquire material-specific images, on which the mean basis material concentrations and noise levels were measured and compared across all triple-beam configurations in EID-MECT and various DECT/MECT systems. RESULTS: The optimal triple-beam configuration was task-dependent with 70/Au120/Sn120, 70/Au140/Sn140, and 70/Au120/Sn120 kV for I/Gd/Water, I/Bi/Water, and I/Gd/Bi/Water material decomposition tasks, respectively. At equal radiation dose level, EID-MECT provided comparable or better quantification accuracy in material-specific images for all three material decomposition tasks, compared to EID-based DECT and PCD-CT systems. In terms of noise level comparison, EID-MECT-derived material-specific images showed lower noise levels than TB-DECT and DS-DECT, but slightly higher than that from PCD-CT in I/Gd/Water imaging. For I/Bi/Water imaging, EID-MECT showed a comparable noise level to DS-DECT, and a much lower noise level than TB-DECT and PCD-CT in all material-specific images. For the four-material decomposition task involving I/Gd/Bi/Water, the bismuth-specific image derived from EID-MECT was slightly noisier, but both iodine- and gadolinium-specific images showed much lower noise levels in comparison to PCD-CT. CONCLUSIONS: For the first time, an EID-based MECT system that can simultaneously acquire three x-ray spectra measurements was implemented on a clinical scanner, which demonstrated comparable or better imaging performance than existing DECT and MECT systems.


Assuntos
Iodo , Fótons , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
16.
Med Phys ; 48(3): 1307-1314, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33332626

RESUMO

PURPOSE: To determine the accuracy of CT number and calcium score of a kV-independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. METHODS: Anthropomorphic chest phantoms were scanned on a third-generation dual-source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20-mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70-140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto-kV). Phantoms were also scanned at 120 kV using a size-dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. RESULTS: The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto-kV provided a 25-34% dose reduction compared to AEC alone. CONCLUSION: A kV-independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto-kV, this technique can reduce radiation by 25-34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.


Assuntos
Cálcio , Doença da Artéria Coronariana , Redução da Medicação , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
17.
IEEE Trans Med Imaging ; 40(1): 251-261, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32956046

RESUMO

Electrical impedance tomography is clinically used to trace ventilation related changes in electrical conductivity of lung tissue. Estimating regional pulmonary perfusion using electrical impedance tomography is still a matter of research. To support clinical decision making, reliable bedside information of pulmonary perfusion is needed. We introduce a method to robustly detect pulmonary perfusion based on indicator-enhanced electrical impedance tomography and validate it by dynamic multidetector computed tomography in two experimental models of acute respiratory distress syndrome. The acute injury was induced in a sublobar segment of the right lung by saline lavage or endotoxin instillation in eight anesthetized mechanically ventilated pigs. For electrical impedance tomography measurements, a conductive bolus (10% saline solution) was injected into the right ventricle during breath hold. Electrical impedance tomography perfusion images were reconstructed by linear and normalized Gauss-Newton reconstruction on a finite element mesh with subsequent element-wise signal and feature analysis. An iodinated contrast agent was used to compute pulmonary blood flow via dynamic multidetector computed tomography. Spatial perfusion was estimated based on first-pass indicator dilution for both electrical impedance and multidetector computed tomography and compared by Pearson correlation and Bland-Altman analysis. Strong correlation was found in dorsoventral (r = 0.92) and in right-to-left directions (r = 0.85) with good limits of agreement of 8.74% in eight lung segments. With a robust electrical impedance tomography perfusion estimation method, we found strong agreement between multidetector computed and electrical impedance tomography perfusion in healthy and regionally injured lungs and demonstrated feasibility of electrical impedance tomography perfusion imaging.


Assuntos
Síndrome do Desconforto Respiratório , Animais , Impedância Elétrica , Pulmão/diagnóstico por imagem , Perfusão , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Suínos , Tomografia , Tomografia Computadorizada por Raios X
18.
Acta Radiol Open ; 10(7): 20584601211030658, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34377539

RESUMO

BACKGROUND: Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. PURPOSE: To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. MATERIALS AND METHODS: Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). RESULTS: 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images (p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images (p = 0.006, p = 0.018). CONCLUSION: A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.

19.
Artigo em Inglês | MEDLINE | ID: mdl-35414740

RESUMO

Energy-integrating-detector (EID)-based triple-beam multi-energy CT (TB-MECT) was recently implemented on a dual-source (DS) CT platform by mounting a z-axis split-filter (0.05 mm Au, 0.6 mm Sn) on one of the two tubes. The purpose of this work is to perform a feasibility animal study on this new MECT platform for a small bowel imaging task using two contrast agents, iodine and bismuth. Optimal triple-beam configurations, 70/Au140/Sn140 kV were determined in a phantom study for this task and applied in the animal study for best material decomposition imaging performance. The results demonstrated that the TB-MECT can successfully separate and quantify the two contrast agents from one single scan for the task of small bowel imaging.

20.
J Med Imaging (Bellingham) ; 7(5): 053501, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33033732

RESUMO

Purpose: Conventional stenosis quantification from single-energy computed tomography (SECT) images relies on segmentation of lumen boundaries, which suffers from partial volume averaging and calcium blooming effects. We present and evaluate a method for quantifying percent area stenosis using multienergy CT (MECT) images. Approach: We utilize material decomposition of MECT images to measure stenosis based on the ratio of iodine mass between vessel locations with and without a stenosis, thereby eliminating the requirement for segmentation of iodinated lumen. The method was first assessed using simulated MECT images created with different spatial resolutions. To experimentally assess this method, four phantoms with different stenosis severity (30% to 51%), vessel diameters (5.5 to 14 mm), and calcification densities (700 to 1100 mgHA / cc ) were fabricated. Conventional SECT images were acquired using a commercial CT system and were analyzed with commercial software. MECT images were acquired using a commercial dual-energy CT (DECT) system and also from a research photon-counting detector CT (PCD-CT) system. Three-material-decomposition was performed on MECT data, and iodine density maps were used to quantify stenosis. Clinical radiation doses were used for all data acquisitions. Results: Computer simulation verified that this method reduced partial volume and blooming effects, resulting in consistent stenosis measurements. Phantom experiments showed accurate and reproducible stenosis measurements from MECT images. For DECT and two-threshold PCD-CT images, the estimation errors were 4.0% to 7.0%, 2.0% to 9.0%, 10.0% to 18.0%, and - 1.0 % to - 5.0 % (ground truth: 51%, 51%, 51%, and 30%). For four-threshold PCD-CT images, the errors were 1.0% to 3.0%, 4.0% to 6.0%, - 1.0 % to 9.0%, and 0.0% to 6.0%. Errors using SECT were much larger, ranging from 4.4% to 46%, and were especially worse in the presence of dense calcifications. Conclusions: The proposed approach was shown to be insensitive to acquisition parameters, demonstrating the potential to improve the accuracy and precision of stenosis measurements in clinical practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA