Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
3.
Artigo em Inglês | MEDLINE | ID: mdl-38743142

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) employing cryoballoon (CB) or contact force-guided radiofrequency (CF-RF) catheter ablation has been established as an effective strategy for managing atrial fibrillation (AF). However, its efficacy in hypertrophic cardiomyopathy (HCM) remains to be further explored. METHODS: This retrospective study analyzed 60 consecutive AF patients with HCM (average age 67 ± 10 years; 41 men) who were consecutively admitted to our hospital from January 2014 to December 2022 and underwent initial PVI. RESULTS: The patients were treated with CB (26 patients) or CF-RF (34 patients). Successful PVI was achieved in both groups without significant complications. In the CF-RF group, additional ablations were performed on the cavotricuspid isthmus (14.7% of patients) and the anterior line (2.9%). The CB group benefited from reduced procedural times (93 ± 31 vs. 165 ± 60 min, p < 0.05) and decreased saline irrigation requirements (77.5 ± 31.4 vs. 870 ± 281.9 mL, p < 0.0001). Using a contrast medium was exclusive to the CB group (33.8 ± 4.2 mL). In a 12-month follow-up, the atrial tachyarrhythmia recurrence-free rates in the CB and CF-RF groups were comparable (77% and 76%, respectively; p = 0.63 according to the log-rank test). Notably, pulmonary vein reconnection was prevalent in most (7 out of 8) patients requiring a secondary ablation procedure. CONCLUSION: PVI is feasible as a strategy for AF in patients with HCM employing either CB or CF-RF techniques. While the recurrence-free rates were comparable in both groups, differences were noted in procedure duration, saline usage, and the need for a contrast medium.

4.
In Vivo ; 37(1): 336-344, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36593049

RESUMO

BACKGROUND/AIM: The relationship between renal function and severity of cardioembolic stroke (CES) stratified by sex remains poorly understood. PATIENTS AND METHODS: A total of 640 consecutive CES patients within 48 h after stroke onset and with a modified Rankin Scale (mRS) score of 0 or 1 before onset were studied. The patients were divided into three groups based on their CCr values: low creatinine clearance (CCr) (L-CCr) (n=71, <30 ml/min), middle CCr (M-CCr) (n=227, 30 to <50 ml/min), and high CCr (H-CCr) (n=342, ≥50 ml/min). We compared the severity and functional outcomes of stroke among the three groups according to sex. RESULTS: On admission, using the National Institutes of Health Stroke Scale, the L-CCr group had the most severe stroke, followed by the M-CCr and H-CCr groups (p<0.0001). Functional outcomes at discharge, assessed using the mRS, were the worst in the L-CCr group, followed by the M-CCr and H-CCr groups (p<0.0001). Multivariable analyses revealed that L-CCr was a significant determinant of severe stroke on admission and poor functional outcomes at discharge. According to sex, L-CCr was a significant determinant of severe stroke on admission and poor functional outcomes at discharge in female patients, but not in male patients. CONCLUSION: Low CCr is a risk factor for severe stroke on admission and unfavorable functional outcomes at discharge in Japanese CES patients, and particularly in female patients.


Assuntos
Fibrilação Atrial , AVC Embólico , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Creatinina , AVC Embólico/complicações , População do Leste Asiático , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Fatores de Risco
5.
J Cardiol ; 80(5): 482-486, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35902323

RESUMO

BACKGROUND: The PRAETORIAN score was developed to evaluate the implant position and predict defibrillation success in patients implanted with a subcutaneous implantable cardioverter-defibrillator (S-ICD). However, usefulness of the PRAETORIAN score for Japanese patients is unknown. METHODS: We evaluated usefulness of this score, which was determined by width of sub-coil fat, sub-generator fat, and anterior positioning of the S-ICD generator by post-operative chest X-ray, in consecutive 100 Japanese S-ICD implanted patients [78 men, median age 59 (IQR 46.5-67.0) years, median body mass index (BMI) 24.2 (21.3-27.2) kg/m2]. RESULTS: The median PRAETORIAN score was 30 (30-45) and 93 patients were classified as a low risk of conversion failure. The remaining seven were at an intermediate risk. Almost all patients were classified as an optimal pulse-generator position in the second and third steps of the PRAETORIAN score. The only difference observed was in the width of sub-coil fat in the first step. To further evaluate its significance, patients were divided into the Thicker group (sub-coil fat >1 coil width, n = 19) and the Thinner group (sub-coil fat ≤1 coil width, n = 81). BMI and post-shock impedance were both higher in the Thicker group than in the Thinner group [27.1 (25.6-31.6) versus 23.1 (20.9-25.7) kg/m2, p < 0.001, and 75 (68-88) versus 63 (55-74) Ω, p = 0.003, respectively]. During the median follow-up periods of 888 (523-1418) days, 7 patients experienced appropriate shock therapy for spontaneous ventricular tachyarrhythmias, who were all at a low risk. No conversion failure was observed. Inappropriate shock (IAS) occurred in 11 patients, and there was no difference in IAS rate between the Thicker group (n = 2) and the Thinner group (n = 9) (p = 0.747 by log-rank test). CONCLUSIONS: Most Japanese patients were classified as at low risk of conversion failure. The PRAETORIAN score may be useful for the evaluation of conversion failure in Japanese S-ICD implanted patients.


Assuntos
Desfibriladores Implantáveis , Índice de Massa Corporal , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Impedância Elétrica , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA