RESUMO
Given the high morbidity related to the progression of gait deficits in spinocerebellar ataxias (SCA), there is a growing interest in identifying biomarkers that can guide early diagnosis and rehabilitation. Spatiotemporal parameter (STP) gait analysis using inertial measurement units (IMUs) has been increasingly studied in this context. This study evaluated STP profiles in SCA types 3 and 10, compared them to controls, and correlated them with clinical scales. IMU portable sensors were used to measure STPs under four gait conditions: self-selected pace (SSP), fast pace (FP), fast pace checking-boxes (FPCB), and fast pace with serial seven subtractions (FPS7). Compared to healthy subjects, both SCA groups had higher values for step time, variability, and swing time, with lower values for gait speed, cadence, and step length. We also found a reduction in speed gain capacity in both SCA groups compared to controls and an increase in speed dual-task cost in the SCA10 group. However, there were no significant differences between the SCA groups. Swing time, mean speed, and step length were correlated with disease severity, risk of falling and functionality in both clinical groups. In the SCA3 group, fear of falling was correlated with cadence. In the SCA10 group, results of the Montreal cognitive assessment test were correlated with step time, mean speed, and step length. These results show that individuals with SCA3 and SCA10 present a highly variable, short-stepped, slow gait pattern compared to healthy subjects, and their gait quality worsened with a fast pace and dual-task involvement.
Assuntos
Análise da Marcha , Doença de Machado-Joseph , Ataxias Espinocerebelares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Análise da Marcha/métodos , Ataxias Espinocerebelares/fisiopatologia , Ataxias Espinocerebelares/diagnóstico , Adulto , Doença de Machado-Joseph/diagnóstico , Doença de Machado-Joseph/fisiopatologia , Transtornos Neurológicos da Marcha/diagnóstico , Transtornos Neurológicos da Marcha/fisiopatologia , Marcha/fisiologia , Análise Espaço-Temporal , Idoso , Expansão das Repetições de DNARESUMO
This case study aims to examine changes in the lower limb joint kinematic profile and performance stability induced by repeated ski runs in two world-class alpine skiers. Two Olympic medallist alpine skiers were tested during their slalom training, with continuous recording of right knee and hip angles, along with turn time and run time. The eight runs of the training session were analysed with linear mixed models. Results showed no effect of runs repetition on performance (i.e., run and turn time; P ≥ 0.279). There was no global effect of runs repetition on minimal and maximal angles for either the knee or the hip (P > 0.151). There was an interaction between run and leg for the maximal angle of both the knee and hip (P ≤ 0.047), which increased across runs for the outside leg and decreased for the inside leg. The maximal angular velocity for both the knee and hip increased with runs repetition in extension (P ≤ 0.028). There were no overall changes in maximal angular velocity in flexion with runs repetition (P ≥ 0.264), but there was an interaction between run and leg for the knee (P < 0.001) due to faster eccentric velocities across runs for the outside leg and slower velocities for the inside leg. In conclusion, the observed joint kinematic alterations without concomitant performance impairment support the concept of multiple movement strategies in athletes to achieve similar performance, especially under fatigue conditions.
RESUMO
Peripheral neuropathy is a common problem in patients with Parkinson's disease. Peripheral neuropathy's prevalence in Parkinson's disease varies between 4.8-55%, compared with 9% in the general population. It remains unclear whether peripheral neuropathy leads to decreased motor performance in Parkinson's disease, resulting in impaired mobility and increased balance deficits. We aimed to determine the prevalence and type of peripheral neuropathy in Parkinson's disease patients and evaluate its functional impact on gait and balance. A cohort of consecutive Parkinson's disease patients assessed by movement disorders specialists based on the UK Brain Bank criteria underwent clinical, neurophysiological (nerve conduction studies and quantitative sensory testing) and neuropathological (intraepidermal nerve fibre density in skin biopsy punches) evaluation to characterize the peripheral neuropathy type and aetiology using a cross-sectional design. Gait and balance were characterized using wearable health-technology in OFF and ON medication states, and the main parameters were extracted using validated algorithms. A total of 99 Parkinson's disease participants with a mean age of 67.2 (±10) years and mean disease duration of 6.5 (±5) years were assessed. Based on a comprehensive clinical, neurophysiological and neuropathological evaluation, we found that 40.4% of Parkinson's disease patients presented peripheral neuropathy, with a predominance of small fibre neuropathy (70% of the group). In the OFF state, the presence of peripheral neuropathy was significantly associated with shorter stride length (P = 0.029), slower gait speed (P = 0.005) and smaller toe-off angles (P = 0.002) during straight walking; significantly slower speed (P = 0.019) and smaller toe-off angles (P = 0.007) were also observed during circular walking. In the ON state, the above effects remained, albeit moderately reduced. With regard to balance, significant differences between Parkinson's disease patients with and without peripheral neuropathy were observed in the OFF medication state during stance with closed eyes on a foam surface. In the ON states, these differences were no longer observable. We showed that peripheral neuropathy is common in Parkinson's disease and influences gait and balance parameters, as measured with mobile health-technology. Our study supports that peripheral neuropathy recognition and directed treatment should be pursued in order to improve gait in Parkinson's disease patients and minimize balance-related disability, targeting individualized medical care.
Assuntos
Transtornos Neurológicos da Marcha , Doença de Parkinson , Doenças do Sistema Nervoso Periférico , Humanos , Idoso , Doença de Parkinson/complicações , Doença de Parkinson/epidemiologia , Estudos Transversais , Prevalência , Marcha/fisiologia , Doenças do Sistema Nervoso Periférico/epidemiologia , Doenças do Sistema Nervoso Periférico/complicações , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/complicações , Equilíbrio Postural/fisiologiaRESUMO
BACKGROUND: How the joints exactly move and interact and how this reflects PD-related gait abnormalities and the response to dopaminergic treatment is poorly understood. A detailed understanding of these kinematics can inform clinical management and treatment decisions. The aim of the study was to investigate the influence of different gait speeds and medication on/off conditions on inter-joint coordination, as well as kinematic differences throughout the whole gait cycle in well characterized pwPD. METHODS: 29 controls and 29 PD patients during medication on, 8 of them also during medication off walked a straight walking path in slow, preferred and fast walking speeds. Gait data was collected using optical motion capture system. Kinematics of the hip and knee and coordinated hip-knee kinematics were evaluated using Statistical Parametric Mapping (SPM) and cyclograms (angle-angle plots). Values derived from cyclograms were compared using repeated-measures ANOVA for within group, and ttest for between group comparisons. RESULTS: PD gait differed from controls mainly by lower knee range of motion (ROM). Adaptation to gait speed in PD was mainly achieved by increasing hip ROM. Regularity of gait was worse in PD but only during preferred speed. The ratios of different speed cyclograms were smaller in the PD groups. SPM analyses revealed that PD participants had smaller hip and knee angles during the swing phase, and PD participants reached peak hip flexion later than controls. Withdrawal of medication showed an exacerbation of only a few parameters. CONCLUSIONS: Our findings demonstrate the potential of granular kinematic analyses, including > 1 joint, for disease and treatment monitoring in PD. Our approach can be extended to further mobility-limiting conditions and other joint combinations. TRIAL REGISTRATION: The study is registered in the German Clinical Trials Register (DRKS00022998, registered on 04 Sep 2020).
Assuntos
Dopaminérgicos , Doença de Parkinson , Amplitude de Movimento Articular , Humanos , Doença de Parkinson/tratamento farmacológico , Doença de Parkinson/fisiopatologia , Masculino , Feminino , Estudos de Casos e Controles , Fenômenos Biomecânicos , Pessoa de Meia-Idade , Idoso , Dopaminérgicos/uso terapêutico , Amplitude de Movimento Articular/fisiologia , Articulação do Joelho/fisiopatologia , Marcha/fisiologia , Marcha/efeitos dos fármacos , Articulação do Quadril/fisiopatologia , Transtornos Neurológicos da Marcha/fisiopatologia , Transtornos Neurológicos da Marcha/tratamento farmacológico , Transtornos Neurológicos da Marcha/etiologia , Articulações/fisiopatologiaRESUMO
BACKGROUND: Maintaining static balance is relevant and common in everyday life and it depends on a correct intersegmental coordination. A change or reduction in postural capacity has been linked to increased risk of falls. People with Parkinson's disease (pwPD) experience motor symptoms affecting the maintenance of a stable posture. The aim of the study is to understand the intersegmental changes in postural sway and to apply a trend change analysis to uncover different movement strategies between pwPD and healthy adults. METHODS: In total, 61 healthy participants, 40 young (YO), 21 old participants (OP), and 29 pwPD (13 during medication off, PDoff; 23 during medication on, PDon) were included. Participants stood quietly for 10 s as part of the Short Physical Performance Battery. Inertial measurement units (IMU) at the head, sternum, and lumbar region were used to extract postural parameters and a trend change analysis (TCA) was performed to compare between groups. OBJECTIVE: This study aims to explore the potential application of TCA for the assessment of postural stability using IMUs, and secondly, to employ this analysis within the context of neurological diseases, specifically Parkinson's disease. RESULTS: Comparison of sensors locations revealed significant differences between head, sternum and pelvis for almost all parameters and cohorts. When comparing PDon and PDoff, the TCA revealed differences that were not seen by any other parameter. CONCLUSIONS: While all parameters could differentiate between sensor locations, no group differences could be uncovered except for the TCA that allowed to distinguish between the PD on/off. The potential of the TCA to assess disease progression, response to treatment or even the prodromal PD phase should be explored in future studies. TRIAL REGISTRATION: The research procedure was approved by the ethical committee of the Medical Faculty of Kiel University (D438/18). The study is registered in the German Clinical Trials Register (DRKS00022998).
Assuntos
Doença de Parkinson , Equilíbrio Postural , Humanos , Doença de Parkinson/fisiopatologia , Doença de Parkinson/diagnóstico , Doença de Parkinson/tratamento farmacológico , Equilíbrio Postural/fisiologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Adulto , Antiparkinsonianos/uso terapêutico , Adulto JovemRESUMO
BACKGROUND: In the Climb Up! Head Up! trial, we showed that sport climbing reduces bradykinesia, tremor, and rigidity in mildly to moderately affected participants with Parkinson's disease. This secondary analysis aimed to evaluate the effects of sport climbing on gait and functional mobility in this cohort. METHODS: Climb Up! Head Up! was a 1:1 randomized controlled trial. Forty-eight PD participants (Hoehn and Yahr stage 2-3) either participated in a 12-week, 90-min-per-week sport climbing course (intervention group) or were engaged in regular unsupervised physical activity (control group). Relevant outcome measures for this analysis were extracted from six inertial measurement units placed on the extremities, chest, and lower back, that were worn during supervised gait and functional mobility assessments before and after the intervention. Assessments included normal and fast walking, dual-tasking walking, Timed Up and Go test, Instrumented Stand and Walk test, and Five Times Sit to Stand test. RESULTS: Compared to baseline, climbing improved gait speed during normal walking by 0.09 m/s (p = 0.005) and during fast walking by 0.1 m/s. Climbing also reduced the time spent in the stance phase during fast walking by 0.03 s. Climbing improved the walking speed in the 7-m- Timed Up and Go test by 0.1 m/s (p < 0.001) and the turning speed by 0.39 s (p = 0.052), the speed in the Instrumented Stand and Walk test by 0.1 m/s (p < 0.001), and the speed in the Five Times Sit to Stand test by 2.5 s (p = 0.014). There was no effect of sport climbing on gait speed or gait variables during dual-task walking. CONCLUSIONS: Sport climbing improves gait speed during normal and fast walking, as well as functional mobility in people with Parkinson's disease. Trial registration This study was registered within the U.S. National Library of Medicine (No: NCT04569981, date of registration September 30th, 2020).
Assuntos
Marcha , Doença de Parkinson , Humanos , Doença de Parkinson/reabilitação , Doença de Parkinson/fisiopatologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Marcha/fisiologia , Locomoção/fisiologia , Terapia por Exercício/métodosRESUMO
Over recent decades, wearable inertial sensors have become popular means to quantify physical activity and mobility. However, research assessing measurement accuracy and precision is required, especially before using device-based measures as outcomes in trials. The GT9X Link is a recent activity monitor available from ActiGraph, recognized as a "gold standard" and previously used as a criterion measure to assess the validity of various consumer-based activity monitors. However, the validity of the ActiGraph GT9X Link is not fully elucidated. A systematic review was undertaken to synthesize the current evidence for the criterion validity of the ActiGraph GT9X Link in measuring steps and energy expenditure. This review followed the PRISMA guidelines and eight studies were included with a combined sample size of 558 participants. We found that (1) the ActiGraph GT9X Link generally underestimates steps; (2) the validity and accuracy of the device in measuring steps seem to be influenced by gait speed, device placement, filtering process, and monitoring conditions; and (3) there is a lack of evidence regarding the accuracy of step counting in free-living conditions and regarding energy expenditure estimation. Given the limited number of included studies and their heterogeneity, the present review emphasizes the need for further validation studies of the ActiGraph GT9X Link in various populations and in both controlled and free-living settings.
Assuntos
Actigrafia , Metabolismo Energético , Humanos , Actigrafia/instrumentação , Actigrafia/métodos , Actigrafia/normas , Metabolismo Energético/fisiologia , Exercício Físico/fisiologia , Monitorização Ambulatorial/métodos , Monitorização Ambulatorial/instrumentação , Dispositivos Eletrônicos Vestíveis , Estudos de Validação como AssuntoRESUMO
BACKGROUND: walking is crucial for an active and healthy ageing, but the perspectives of individuals living with walking impairment are still poorly understood. OBJECTIVES: to identify and synthesise evidence describing walking as experienced by adults living with mobility-impairing health conditions and to propose an empirical conceptual framework of walking experience. METHODS: we performed a systematic review and meta-ethnography of qualitative evidence, searching seven electronic databases for records that explored personal experiences of walking in individuals living with conditions of diverse aetiology. Conditions included Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, hip fracture, heart failure, frailty and sarcopenia. Data were extracted, critically appraised using the NICE quality checklist and synthesised using standardised best practices. RESULTS: from 2,552 unique records, 117 were eligible. Walking experience was similar across conditions and described by seven themes: (i) becoming aware of the personal walking experience, (ii) the walking experience as a link between individuals' activities and sense of self, (iii) the physical walking experience, (iv) the mental and emotional walking experience, (v) the social walking experience, (vi) the context of the walking experience and (vii) behavioural and attitudinal adaptations resulting from the walking experience. We propose a novel conceptual framework that visually represents the walking experience, informed by the interplay between these themes. CONCLUSION: a multi-faceted and dynamic experience of walking was common across health conditions. Our conceptual framework of the walking experience provides a novel theoretical structure for patient-centred clinical practice, research and public health.
Assuntos
Antropologia Cultural , Caminhada , Humanos , Pesquisa Qualitativa , Antropologia Cultural/métodosRESUMO
BACKGROUND: Turning during walking is a relevant and common everyday movement and it depends on a correct top-down intersegmental coordination. This could be reduced in several conditions (en bloc turning), and an altered turning kinematics has been linked to increased risk of falls. Smartphone use has been associated with poorer balance and gait; however, its effect on turning-while-walking has not been investigated yet. This study explores turning intersegmental coordination during smartphone use in different age groups and neurologic conditions. OBJECTIVE: This study aims to evaluate the effect of smartphone use on turning behavior in healthy individuals of different ages and those with various neurological diseases. METHODS: Younger (aged 18-60 years) and older (aged >60 years) healthy individuals and those with Parkinson disease, multiple sclerosis, subacute stroke (<4 weeks), or lower-back pain performed turning-while-walking alone (single task [ST]) and while performing 2 different cognitive tasks of increasing complexity (dual task [DT]). The mobility task consisted of walking up and down a 5-m walkway at self-selected speed, thus including 180° turns. Cognitive tasks consisted of a simple reaction time test (simple DT [SDT]) and a numerical Stroop test (complex DT [CDT]). General (turn duration and the number of steps while turning), segmental (peak angular velocity), and intersegmental turning parameters (intersegmental turning onset latency and maximum intersegmental angle) were extracted for head, sternum, and pelvis using a motion capture system and a turning detection algorithm. RESULTS: In total, 121 participants were enrolled. All participants, irrespective of age and neurologic disease, showed a reduced intersegmental turning onset latency and a reduced maximum intersegmental angle of both pelvis and sternum relative to head, thus indicating an en bloc turning behavior when using a smartphone. With regard to change from the ST to turning when using a smartphone, participants with Parkinson disease reduced their peak angular velocity the most, which was significantly different from lower-back pain relative to the head (P<.01). Participants with stroke showed en bloc turning already without smartphone use. CONCLUSIONS: Smartphone use during turning-while-walking may lead to en bloc turning and thus increase fall risk across age and neurologic disease groups. This behavior is probably particularly dangerous for those groups with the most pronounced changes in turning parameters during smartphone use and the highest fall risk, such as individuals with Parkinson disease. Moreover, the experimental paradigm presented here might be useful in differentiating individuals with lower-back pain without and those with early or prodromal Parkinson disease. In individuals with subacute stroke, en bloc turning could represent a compensative strategy to overcome the newly occurring mobility deficit. Considering the ubiquitous smartphone use in daily life, this study should stimulate future studies in the area of fall risk and neurological and orthopedic diseases. TRIAL REGISTRATION: German Clinical Trials Register DRKS00022998; https://drks.de/search/en/trial/DRKS00022998.
Assuntos
Doença de Parkinson , Acidente Vascular Cerebral , Humanos , Doença de Parkinson/complicações , Smartphone , Marcha , Caminhada , Acidente Vascular Cerebral/complicações , Dor nas CostasRESUMO
BACKGROUND: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. METHODS: Twenty healthy older adults, 20 people with Parkinson's disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. RESULTS: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms' performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. CONCLUSIONS: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms' performances. Trial registration ISRCTN - 12246987.
Assuntos
Tecnologia Digital , Fraturas Proximais do Fêmur , Humanos , Idoso , Marcha , Caminhada , Velocidade de Caminhada , Modalidades de FisioterapiaRESUMO
Daily steps could be a valuable indicator of real-world ambulation in Parkinson's disease (PD). Nonetheless, no study to date has investigated the minimum number of days required to reliably estimate the average daily steps through commercial smartwatches in people with PD. Fifty-six patients were monitored through a commercial smartwatch for 5 consecutive days. The total daily steps for each day was recorded and the average daily steps was calculated as well as the working and weekend days average steps. The intraclass correlation coefficient (ICC) (3,k), standard error of measurement (SEM), Bland-Altman statistics, and minimum detectable change (MDC) were used to evaluate the reliability of the step count for every combination of 2-5 days. The threshold for acceptability was set at an ICC ≥ 0.8 with a lower bound of CI 95% ≥ 0.75 and a SAM < 10%. ANOVA and Mann-Whitney tests were used to compare steps across the days and between the working and weekend days, respectively. Four days were needed to achieve an acceptable reliability (ICC range: 0.84-0.90; SAM range: 7.8-9.4%). In addition, daily steps did not significantly differ across the days and between the working and weekend days. These findings could support the use of step count as a walking activity index and could be relevant to developing monitoring, preventive, and rehabilitation strategies for people with PD.
Assuntos
Doença de Parkinson , Humanos , Doença de Parkinson/reabilitação , Reprodutibilidade dos Testes , CaminhadaRESUMO
The swallowing process involves complex muscle coordination mechanisms. When alterations in such mechanisms are produced by neurological conditions or diseases, a swallowing disorder known as dysphagia occurs. The instrumental evaluation of dysphagia is currently performed by invasive and experience-dependent techniques. Otherwise, non-invasive magnetic methods have proven to be suitable for various biomedical applications and might also be applicable for an objective swallowing assessment. In this pilot study, we performed a novel approach for deglutition evaluation based on active magnetic motion sensing with permanent magnet cantilever actuators. During the intake of liquids with different consistency, we recorded magnetic signals of relative movements between a stationary sensor and a body-worn actuator on the cricoid cartilage. Our results indicate the detection capability of swallowing-related movements in terms of a characteristic pattern. Consequently, the proposed technique offers the potential for dysphagia screening and biofeedback-based therapies.
Assuntos
Transtornos de Deglutição , Sistemas Microeletromecânicos , Humanos , Transtornos de Deglutição/diagnóstico , Deglutição/fisiologia , Projetos Piloto , Fenômenos MagnéticosRESUMO
BACKGROUND: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. METHODS: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants' strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson's disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. RESULTS: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. CONCLUSIONS: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. TRIAL REGISTRATION: ISRCTN-12246987.
Assuntos
Marcha , Doença de Parkinson , Adulto , Humanos , Caminhada , Velocidade de Caminhada , Projetos de PesquisaRESUMO
Monitoring disease progression in Parkinson's disease is challenging. Postural transfers by sit-to-stand motions are adapted to trace the motor performance of subjects. Wearable sensors such as inertial measurement units allow for monitoring motion performance. We propose quantifying the sit-to-stand performance based on two scores compiling kinematics, dynamics, and energy-related variables. Three groups participated in this research: asymptomatic young participants (n = 33), senior asymptomatic participants (n = 17), and Parkinson's patients (n = 20). An unsupervised classification was performed of the two scores to differentiate the three populations. We found a sensitivity of 0.4 and a specificity of 0.96 to distinguish Parkinson's patients from asymptomatic subjects. In addition, seven Parkinson's patients performed the sit-to-stand task "ON" and "OFF" medication, and we noted the scores improved with the patients' medication states (MDS-UPDRS III scores). Our investigation revealed that Parkinson's patients demonstrate a wide spectrum of mobility variations, and while one inertial measurement unit can quantify the sit-to-stand performance, differentiating between PD patients and healthy adults and distinguishing between "ON" and "OFF" periods in PD patients is still challenging.
Assuntos
Doença de Parkinson , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Doença de Parkinson/diagnóstico , Fenômenos Biomecânicos , Movimento (Física)RESUMO
Parkinson's disease (PD) is a complex neurodegenerative disease with a multitude of disease variations including motor and non-motor symptoms. Quality of life and symptom management may be improved with physical activity. Due to technological advancement, development of small new wearable devices recently emerged and allowed objective measurement of walking activity in daily life. This review was specifically designed to synthesize literature on objective walking activity measurements using wearable devices of patients with PD. Inclusion criteria included patients with a diagnosis of PD and exclusion criteria included studies using animal models or mixed syndromes. Participants were not required to undergo any type of intervention and the studies must have reported at least one output that quantifies daily walking activity. Three databases were systematically searched with no limitation on publication date. Twenty-six studies were eligible and included in the systematic review. The most frequently used device was the ActiGraph GT3X which was used in 10 studies. Duration of monitoring presented a range from 8 h to one year. Nevertheless, 11 studies measured walking activity during a 7-day period. On-body sensor wearing location differed throughout the included studies showing eight positions, with the waist, ankle, and wrist being the most frequently used locations. The main procedures consisted of measurement of walking hours during a 2-day period or more, equipped with a triaxial accelerometer at the dominant hip or ankle. It is also important for further research to take care of different factors such as the population, their pathology, the period, and the environment.
Assuntos
Doenças Neurodegenerativas , Doença de Parkinson , Dispositivos Eletrônicos Vestíveis , Humanos , Doença de Parkinson/diagnóstico , Qualidade de Vida , CaminhadaRESUMO
Many algorithms use 3D accelerometer and/or gyroscope data from inertial measurement unit (IMU) sensors to detect gait events (i.e., initial and final foot contact). However, these algorithms often require knowledge about sensor orientation and use empirically derived thresholds. As alignment cannot always be controlled for in ambulatory assessments, methods are needed that require little knowledge on sensor location and orientation, e.g., a convolutional neural network-based deep learning model. Therefore, 157 participants from healthy and neurologically diseased cohorts walked 5 m distances at slow, preferred, and fast walking speed, while data were collected from IMUs on the left and right ankle and shank. Gait events were detected and stride parameters were extracted using a deep learning model and an optoelectronic motion capture (OMC) system for reference. The deep learning model consisted of convolutional layers using dilated convolutions, followed by two independent fully connected layers to predict whether a time step corresponded to the event of initial contact (IC) or final contact (FC), respectively. Results showed a high detection rate for both initial and final contacts across sensor locations (recall ≥92%, precision ≥97%). Time agreement was excellent as witnessed from the median time error (0.005 s) and corresponding inter-quartile range (0.020 s). The extracted stride-specific parameters were in good agreement with parameters derived from the OMC system (maximum mean difference 0.003 s and corresponding maximum limits of agreement (-0.049 s, 0.051 s) for a 95% confidence level). Thus, the deep learning approach was considered a valid approach for detecting gait events and extracting stride-specific parameters with little knowledge on exact IMU location and orientation in conditions with and without walking pathologies due to neurological diseases.
Assuntos
Aprendizado Profundo , Tornozelo , Pé , Marcha , Humanos , CaminhadaRESUMO
Commercial smartwatches could be useful for step counting and monitoring ambulatory activity. However, in Parkinson's disease (PD) patients, an altered gait, pharmacological condition, and symptoms lateralization may affect their accuracy and potential usefulness in research and clinical routine. Steps were counted during a 6 min walk in 47 patients with PD and 47 healthy subjects (HS) wearing a Garmin Vivosmart 4 (GV4) on each wrist. Manual step counting was used as a reference. An inertial sensor (BTS G-Walk), placed on the lower back, was used to compute spatial-temporal gait parameters. Intraclass correlation coefficient (ICC) and mean absolute percentage error (MAPE) were used for accuracy evaluation and the Spearman test was used to assess the correlations between variables. The GV4 overestimated steps in PD patients with only a poor-to-moderate agreement. The OFF pharmacological state and wearing the device on the most-affected body side led to an unacceptable accuracy. The GV4 showed an excellent agreement and MAPE in HS at a self-selected speed, but an unacceptable performance at a slow speed. In PD patients, MAPE was not associated with gait parameters and clinical variables. The accuracy of commercial smartwatches for monitoring step counting might be reduced in PD patients and further influenced by the pharmacological condition and placement of the device.
Assuntos
Doença de Parkinson , Humanos , Marcha , Caminhada , Pacientes , PunhoRESUMO
Evaluating gait is part of every neurological movement disorder assessment. Generally, the physician assesses the patient based on their experience, but nowadays inertial measurement units (IMUs) are also often integrated in the assessment. Instrumented gait analysis has a longstanding tradition and temporal parameters are used to compare patient groups or trace disease progression over time. However, the day-to-day variability needs to be considered especially in specific patient cohorts. The aim of the study was to examine day-to-day variability of temporal gait parameters of two experimental conditions in a cohort of neurogeriatric patients using data extracted from a lower back-worn IMU. We recruited 49 participants (24 women (age: 78 years ± 6 years, BMI = 25.1 kg/m2 and 25 men (age: 77 years ± 6 years, BMI = 26.5 kg/m2)) from the neurogeriatric ward. Two gait distances (4 m and 20 m) were performed during the first session and repeated the following day. To evaluate reliability, the Intraclass Correlation Coefficient (ICC2,k) and minimal detectable change (MDC) were calculated for the number of steps, step time, stride time, stance time, swing time, double limb support time, double limb support time variability, stride time variability and stride time asymmetry. The temporal gait parameters showed poor to moderate reliability with mean ICC and mean MDC95% values of 0.57 ± 0.18 and 52% ± 53%, respectively. Overall, only four out of the nine computed temporal gait parameters showed high relative reliability and good absolute reliability values. The reliability increased with walking distance. When only investigating steady-state walking during the 20 m walking condition, the relative and absolute reliability improved again. The most reliable parameters were swing time, stride time, step time and stance time. Study results demonstrate that reliability is an important factor to consider when working with IMU derived gait parameters in specific patient cohorts. This advocates for a careful parameter selection as not all parameters seem to be suitable when assessing gait in neurogeriatric patients.
Assuntos
Doenças do Sistema Nervoso , Caminhada , Idoso , Feminino , Marcha , Análise da Marcha , Humanos , Masculino , Reprodutibilidade dos TestesRESUMO
BACKGROUND: Human well-being has been linked to the composition and functional capacity of the intestinal microbiota. As regular exercise is known to improve human health, it is not surprising that exercise was previously described to positively modulate the gut microbiota, too. However, most previous studies mainly focused on either elite athletes or animal models. Thus, we conducted a randomised intervention study that focused on the effects of different types of training (endurance and strength) in previously physically inactive, healthy adults in comparison to controls that did not perform regular exercise. Overall study duration was ten weeks including six weeks of intervention period. In addition to 16S rRNA gene amplicon sequencing of longitudinally sampled faecal material of participants (six time points), detailed body composition measurements and analysis of blood samples (at baseline and after the intervention) were performed to obtain overall physiological changes within the intervention period. Activity tracker devices (wrist-band wearables) provided activity status and sleeping patterns of participants as well as exercise intensity and heart measurements. RESULTS: Different biometric responses between endurance and strength activities were identified, such as a significant increase of lymphocytes and decrease of mean corpuscular haemoglobin concentration (MCHC) only within the strength intervention group. In the endurance group, we observed a significant reduction in hip circumference and an increase in physical working capacity (PWC). Though a large variation of microbiota changes were observed between individuals of the same group, we did not find specific collective alterations in the endurance nor the strength groups, arguing for microbiome variations specific to individuals, and therefore, were not captured in our analysis. CONCLUSIONS: We could show that different types of exercise have distinct but moderate effects on the overall physiology of humans and very distinct microbial changes in the gut. The observed overall changes during the intervention highlight the importance of physical activity on well-being. Future studies should investigate the effect of exercise on a longer timescale, investigate different training intensities and consider high-resolution shotgun metagenomics technology. TRIAL REGISTRATION: DRKS, DRKS00015873 . Registered 12 December 2018; Retrospectively registered.
Assuntos
Exercício Físico , Microbioma Gastrointestinal , Adulto , Bactérias/classificação , Bactérias/genética , Bactérias/isolamento & purificação , DNA Bacteriano/genética , Dieta , Fezes/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , RNA Ribossômico 16S/genética , Adulto JovemRESUMO
There are no effective treatments in progressive supranuclear palsy (PSP). The aim of this study was to test the efficacy of theta burst repetitive transcranial magnetic stimulation (rTMS) on postural instability in PSP. Twenty PSP patients underwent a session of sham or real cerebellar rTMS in a crossover design. Before and after stimulation, static balance was evaluated with instrumented (lower back accelerometer, Rehagait®, Hasomed, Germany) 30-s trials in semitandem and tandem positions. In tandem and semitandem tasks, active stimulation was associated with increase in time without falls (both p=0.04). In the same tasks, device-extracted parameters revealed significant improvement in area (p=0.007), velocity (p=0.005), acceleration and jerkiness of sway (p=0.008) in real versus sham stimulation. Cerebellar rTMS showed a significant effect on stability in PSP patients, when assessed with mobile digital technology, in a double-blind design. These results should motivate larger and longer trials using non-invasive brain stimulation for PSP patients.