Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Neurology ; 92(6): e576-e586, 2019 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-30610090

RESUMO

OBJECTIVE: To determine the diagnostic accuracy and clinical utility of electromagnetic source imaging (EMSI) in presurgical evaluation of patients with epilepsy. METHODS: We prospectively recorded magnetoencephalography (MEG) simultaneously with EEG and performed EMSI, comprising electric source imaging, magnetic source imaging, and analysis of combined MEG-EEG datasets, using 2 different software packages. As reference standard for irritative zone (IZ) and seizure onset zone (SOZ), we used intracranial recordings and for localization accuracy, outcome 1 year after operation. RESULTS: We included 141 consecutive patients. EMSI showed localized epileptiform discharges in 94 patients (67%). Most of the epileptiform discharge clusters (72%) were identified by both modalities, 15% only by EEG, and 14% only by MEG. Agreement was substantial between inverse solutions and moderate between software packages. EMSI provided new information that changed the management plan in 34% of the patients, and these changes were useful in 80%. Depending on the method, EMSI had a concordance of 53% to 89% with IZ and 35% to 73% with SOZ. Localization accuracy of EMSI was between 44% and 57%, which was not significantly different from MRI (49%-76%) and PET (54%-85%). Combined EMSI achieved significantly higher odds ratio compared to electric source imaging and magnetic source imaging. CONCLUSION: EMSI has accuracy similar to established imaging methods and provides clinically useful, new information in 34% of the patients. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that EMSI had a concordance of 53%-89% and 35%-73% (depending on analysis) for the localization of epileptic focus as compared with intracranial recordings-IZ and SOZ, respectively.


Assuntos
Epilepsia/diagnóstico por imagem , Adolescente , Adulto , Idoso , Criança , Eletroencefalografia , Epilepsia/fisiopatologia , Epilepsia/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Magnetoencefalografia , Masculino , Pessoa de Meia-Idade , Neuroimagem , Procedimentos Neurocirúrgicos , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
2.
Clin Neurophysiol ; 127(10): 3301-5, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27573996

RESUMO

OBJECTIVE: To elucidate the possible additional diagnostic yield of MEG in the workup of patients with suspected epilepsy, where repeated EEGs, including sleep-recordings failed to identify abnormalities. METHODS: Fifty-two consecutive patients with clinical suspicion of epilepsy and at least three normal EEGs, including sleep-EEG, were prospectively analyzed. The reference standard was inferred from the diagnosis obtained from the medical charts, after at least one-year follow-up. MEG (306-channel, whole-head) and simultaneous EEG (MEG-EEG) was recorded for one hour. The added sensitivity of MEG was calculated from the cases where abnormalities were seen in MEG but not EEG. RESULTS: Twenty-two patients had the diagnosis epilepsy according to the reference standard. MEG-EEG detected abnormalities, and supported the diagnosis in nine of the 22 patients with the diagnosis epilepsy at one-year follow-up. Sensitivity of MEG-EEG was 41%. The added sensitivity of MEG was 18%. MEG-EEG was normal in 28 of the 30 patients categorized as 'not epilepsy' at one year follow-up, yielding a specificity of 93%. CONCLUSIONS: MEG provides additional diagnostic information in patients suspected for epilepsy, where repeated EEG recordings fail to demonstrate abnormality. SIGNIFICANCE: MEG should be included in the diagnostic workup of patients where the conventional, widely available methods are unrevealing.


Assuntos
Eletroencefalografia , Epilepsia/diagnóstico , Magnetoencefalografia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
3.
Clin Neurophysiol ; 127(2): 1067-1072, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26238854

RESUMO

OBJECTIVE: Reviewing magnetoencephalography (MEG) recordings is time-consuming: signals from the 306 MEG-sensors are typically reviewed divided into six arrays of 51 sensors each, thus browsing each recording six times in order to evaluate all signals. A novel method of reconstructing the MEG signals in source-space was developed using a source-montage of 29 brain-regions and two spatial components to remove magnetocardiographic (MKG) artefacts. Our objective was to evaluate the accuracy of reviewing MEG in source-space. METHODS: In 60 consecutive patients with epilepsy, we prospectively evaluated the accuracy of reviewing the MEG signals in source-space as compared to the classical method of reviewing them in sensor-space. RESULTS: All 46 spike-clusters identified in sensor-space were also identified in source-space. Two additional spike-clusters were identified in source-space. As 29 source-channels can be easily displayed simultaneously, MEG recordings had to be browsed only once. Yet, this yielded a global coverage of the recorded signals and enhanced detectability of epileptiform discharges because MKG-artefacts were suppressed and did not impede evaluation in source-space. CONCLUSIONS: Our results show that reviewing MEG recordings in source-space is accurate and much more rapid than the classical method of reviewing in sensor-space. SIGNIFICANCE: This novel method facilitates the clinical use of MEG.


Assuntos
Potenciais de Ação/fisiologia , Epilepsia/diagnóstico , Epilepsia/fisiopatologia , Magnetoencefalografia/métodos , Magnetoencefalografia/normas , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA