Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Nano Lett ; 17(8): 4941-4945, 2017 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-28671833

RESUMO

The feasibility of many proposals in nanoquantum-optics depends on the efficient coupling of photons to individual quantum emitters, the possibility to control this interaction on demand, and the scalability of the experimental platform. To address these issues, we report on chip-based systems made of one-dimensional subwavelength dielectric waveguides (nanoguides) and polycyclic aromatic hydrocarbon molecules. We discuss the design and fabrication requirements, present data on extinction spectroscopy of single molecules coupled to a nanoguide mode, and show how an external optical beam can switch the propagation of light via a nonlinear optical process. The presented architecture paves the way for the investigation of many-body phenomena and polaritonic states and can be readily extended to more complex geometries for the realization of quantum integrated photonic circuits.

2.
Opt Express ; 24(5): 5087-5101, 2016 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-29092337

RESUMO

The modulus of the degree of coherence can be derived from interference patterns either by using fringes and next neighbour operations or by using several interferograms produced through phase shifting. Here the latter approach will be followed by using a lateral shearing interferometer exploiting a diffractive grating wedge providing a linearly progressive shear. Phase shifting methods offer pixel-oriented evaluations but suffer from instabilities and drifts which is the reason for the derivation of an error immune algorithm. This algorithm will use five π/2-steps of the reference phase also for the calculation of the modulus of the coherence function.

3.
Biophys J ; 109(1): 26-34, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26153699

RESUMO

We describe a method for quantifying the mechanical properties of cells in suspension with a microfluidic device consisting of a parallel array of micron-sized constrictions. Using a high-speed charge-coupled device camera, we measure the flow speed, cell deformation, and entry time into the constrictions of several hundred cells per minute during their passage through the device. From the flow speed and the occupation state of the microconstriction array with cells, the driving pressure across each constriction is continuously computed. Cell entry times into microconstrictions decrease with increased driving pressure and decreased cell size according to a power law. From this power-law relationship, the cell elasticity and fluidity can be estimated. When cells are treated with drugs that depolymerize or stabilize the cytoskeleton or the nucleus, elasticity and fluidity data from all treatments collapse onto a master curve. Power-law rheology and collapse onto a master curve are predicted by the theory of soft glassy materials and have been previously shown to describe the mechanical behavior of cells adhering to a substrate. Our finding that this theory also applies to cells in suspension provides the foundation for a quantitative high-throughput measurement of cell mechanical properties with microfluidic devices.


Assuntos
Fenômenos Fisiológicos Celulares , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Linhagem Celular Tumoral , Núcleo Celular/efeitos dos fármacos , Núcleo Celular/fisiologia , Fenômenos Fisiológicos Celulares/efeitos dos fármacos , Citoesqueleto/efeitos dos fármacos , Citoesqueleto/fisiologia , Desenho de Equipamento , Vidro/química , Humanos , Fenômenos Mecânicos , Técnicas Analíticas Microfluídicas/métodos , Microtecnologia/instrumentação , Modelos Teóricos , Pressão , Reologia
4.
Opt Express ; 23(1): 413-21, 2015 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-25835686

RESUMO

We report on the fabrication and the experimental demonstration of Moiré diffractive spiral phase plates with adjustable helical charge. The proposed optical unit consists of two axially stacked diffractive elements of conjugate structure. The joint transmission function of the compound system corresponds to that of a spiral phase plate where the angle of mutual rotation about the central axis enables continuous adjustment of the helical charge. The diffractive elements are fabricated by gray-scale photolithography with a pixel size of 200 nm and 128 phase step levels in fused silica. We experimentally demonstrate the conversion of a TEM(00) beam into approximated Laguerre-Gauss (LG) beams of variable helical charge, with a correspondingly variable radius of their ring-shaped intensity distribution.

5.
Opt Lett ; 37(19): 4140-2, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23027305

RESUMO

Optical components manipulating both polarization and phase of wave fields find more and more applications in today's optical systems. In particular, the polarization orientation may vary across the aperture. New measurement techniques and evaluation algorithms are needed to simultaneously characterize the properties of such elements. In this Letter, a general measurement algorithm for locally linear polarization distributions is presented, extending the methods of phase shifting interferometry to the simultaneous determination of polarization and phase. A class of evaluation algorithms is derived, and some example algorithms are described and tested for their resilience against systematic and stochastic stepping errors.

6.
Opt Express ; 19(3): 1930-5, 2011 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-21369008

RESUMO

Parallel two-step phase-shifting point-diffraction interferometry for microscopy based on a pair of cube beamsplitters is proposed. The first 45°-tilted cube beamsplitter splits object wave into two parallel copies: one copy is filtered by a pinhole in its Fourier plane to behave as reference wave, while the other one remains unchanged as object wave. The second cube beamsplitter combines the object and reference waves, and then split them together into two beams. Along with the two beams, two parallel phase-shifting interferograms are obtained in aid of polarization elements. Based on the proposed configuration, slightly-off-axis interferometry for microscopy is performed, which suppresses dc term by subtracting the two phase-shifting holograms from each other. The setup is highly stable due to its common-path configuration, and has been demonstrated to be suitable for measuring moving objects or dynamic processes.


Assuntos
Aumento da Imagem/instrumentação , Interferometria/instrumentação , Microscopia de Polarização/instrumentação , Refratometria/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
7.
Opt Lett ; 36(21): 4305-7, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22048399

RESUMO

Zernike phase contrast microscopy is extended and combined with a phase-shifting mechanism to perform quantitative phase measurements of microscopic objects. Dozens of discrete point light sources on a ring are constructed for illumination. For each point light source, three different levels of point-like phase steps are designed, which are alternatively located along a ring on a silica plate to perform phase retardation on the undiffracted (dc) component of the object waves. These three levels of the phase steps are respectively selected by rotating the silica plate. Thus, quantitative evaluation of phase specimens can be performed via phase-shifting mechanism. The proposed method has low "halo" and "shade-off" effects, low coherent noise level, and high lateral resolution due to the improved illumination scheme.

8.
J Opt Soc Am A Opt Image Sci Vis ; 28(3): 434-40, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21383826

RESUMO

An optical configuration for parallel two-step phase-shifting digital holographic microscopy (DHM) based on a grating pair is proposed for the purpose of real-time phase microscopy. Orthogonally circularly polarized object and reference waves are diffracted twice by a pair of gratings, and two parallel copies for each beams come into being. Combined with polarization elements, parallel two-step phase-shifting holograms are obtained. Based on the proposed configuration, two schemes of DHM, i.e., slightly off-axis and on-axis DHM, have been implemented. The slightly off-axis DHM suppresses the dc term by subtracting the two phase-shifting holograms from each other, thus the requirement on the off-axis angle and sampling power of the CCD camera is reduced greatly. The on-axis DHM has the least requirement on the resolving power of the CCD camera, while it requires that the reference wave is premeasured and its intensity is no less than 2 times the maximal intensity of the object wave.

9.
Appl Opt ; 50(4): 571-8, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21283249

RESUMO

Measurements of wavefront deformations can be carried out with the help of lateral shearing interferometers. Here the focus is on a setup providing two shears along orthogonal directions simultaneously to generate the data needed for a reconstruction. We describe a diffractive solution using Ronchi phase gratings with a suppressed zeroth order for both the doubling of the wavefront under test and the bidirectional shearing unit. A series arrangement of the gratings offers an on-axis geometry, which minimizes the systematic errors of the test. For illumination, an extended incoherent monochromatic light source is used. High-contrast fringes can be obtained by tailoring the degree of coherence via a periodic intensity distribution.

10.
Opt Lett ; 35(5): 712-4, 2010 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20195328

RESUMO

A new common-path and in-line point-diffraction interferometer for quantitative phase microscopy is proposed. The interferometer is constructed by introducing a grating pair into the point-diffraction interferometer, thus forming a common-path and in-line configuration for object and reference waves. Achromatic phase shifting is implemented by linearly moving one of the two gratings in its grating vector direction. The feasibility of the proposed configuration is demonstrated by theoretical analysis and experiments.

11.
Appl Opt ; 49(9): 1599-606, 2010 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-20300156

RESUMO

In this work we investigate, analytically and numerically, the effect on the diffracted field produced by typical fabrication errors in sawtooth gratings. The analysis is carried out for the near and far field, showing the effects on the intensity and on the diffraction orders efficiency. When the grating profile is not perfect but presents a curved profile or overdevelopment error, some different diffraction orders appear, changing the intensity and the efficiency of each order. In addition, when roughness is present, a decreasing of efficiency is produced, but without generating different diffraction orders than the first one. We show the analytical dependence of these modifications in terms of the profile of the grating, corroborating the results with numerical methods.

12.
Appl Opt ; 49(12): 2382-90, 2010 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-20411020

RESUMO

Normally, fly's eye condensers are used to homogenize light. However, in the case of fully coherent light, a fly's eye condenser, in connection with some simple optical elements, such as a diffractive axicon, a grating, and a telescope, can be used as a quite flexible beam shaping system, forming arrays of rings, parts of rings, or other structures with varying diameters. We present the principle, some simulation results, and some first experimental results.

13.
Opt Lett ; 34(20): 3178-80, 2009 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-19838265

RESUMO

Increasing accuracy requirements in aspheric metrology make the development of absolute testing procedures for aspheric surfaces important. One strategy is transferring the standard practice three-position test for spheres to aspherics. The three-position test, however, involves a cat's eye position and therefore has certain drawbacks. We propose an absolute testing method for rotationally symmetric aspherics where the cat's eye position is replaced with a radially sheared position. Together with rotational movements of the specimen, the surface deviations can be obtained in an absolute manner. To demonstrate the validity of the procedure, we present a measurement result for a sphere and compare it with a result obtained by the standard three-position test.

14.
Opt Lett ; 34(22): 3553-5, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19927208

RESUMO

A simple algorithm for blind extraction of phase shifts is proposed for generalized phase-shifting interferometry from only three interferograms. Based on the statistical property of the object wave, the algorithm calculates approximately the involved phase shifts as initial values. The extraction is further improved by an iterative method, considering the fact that the closer the phase shifts approach their real values, the more uniform the reconstructed reference wave will become. The feasibility of this algorithm is demonstrated by both simulation and experiment.

15.
Appl Opt ; 46(28): 7040-8, 2007 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-17906734

RESUMO

Aspheric optical surfaces are often tested using diffractive optics as null elements. For precise measurements, the errors caused by the diffractive optical element must be calibrated. Recently, we reported first experimental results of a three position quasi-absolute test for rotationally invariant aspherics by using combined-diffractive optical elements (combo-DOEs). Here we investigate the effects of the DOE substrate errors on the proposed calibration procedure and present a set of criteria for designing an optimized combo-DOE. It is demonstrated that this optimized design enhances the overall consistency of the procedure. Furthermore, the rotationally varying part of the surface deviations is compared with the rotationally varying deviations obtained by an N-position averaging procedure and is found to be in good agreement.

16.
Appl Opt ; 41(1): 64-9, 2002 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-11900447

RESUMO

Grazing-incidence interferometry that makes use of diffractive axicons for the measurement of cylindrical mantle surfaces has already been reported. However, measurement of concave rod structures poses a severe problem because these structures are subject to spurious fringes caused by parasitic diffraction orders of the diffractive axicons. By breaking the symmetry of the interferometric setup it is possible to obtain unique interferograms of the inner mantle surfaces of hollow cylinders as cages for roller bearings or other workpieces produced on lathe machines that have a suitable surface finish. Special design issues for the computer-generated holograms and the interferometric setup are discussed, and test examples are given.

SELEÇÃO DE REFERÊNCIAS