Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pediatr Dermatol ; 32(4): e181-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25968096

RESUMO

The eruptive disseminated form of Spitz nevi (EDSN) is the rarest variant, is cosmetically disabling, and has a poorly documented natural history. We report the case of a 4-year-old boy with more than 100 Spitz nevi that have significantly regressed 8 years after onset. There is no satisfactory treatment for EDSN. There have been no reports of supervening malignancy. Our case illustrates the possibility of regression of EDSN, corroborating long-term observation as a safe and acceptable management option.


Assuntos
Nevo de Células Epitelioides e Fusiformes/fisiopatologia , Neoplasias Cutâneas/fisiopatologia , Pré-Escolar , Humanos , Masculino , Nevo de Células Epitelioides e Fusiformes/diagnóstico , Observação/métodos , Remissão Espontânea , Neoplasias Cutâneas/diagnóstico , Conduta Expectante/métodos
2.
Arch Dis Child Fetal Neonatal Ed ; 106(1): 57-61, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32611602

RESUMO

BACKGROUND: Evidence is lacking as to whether ambient light or phototherapy light could interfere with pulse oximeter performance. METHODS: In this randomised cross-over trial, we recruited neonates of gestation >24 weeks. Consented infants were randomly assigned to either pulse oximeter sensor with opaque wrap or without opaque wrap. Nellcor and Masimo sensors were applied simultaneously to different feet for 10 min of recording. Infants were crossed over to the other intervention for a further 10 min, totalling 20 min recording per infant. Primary outcome was faster acquisition of data with shielding of pulse oximeter sensor as compared with not shielding. RESULTS: A total of 96 babies were recruited. There was no difference in primary outcome of time taken to display valid data between the two groups (opaque wrap: 12.73±3.1 s vs no opaque wrap: 13.16±3.3 s, p=0.27). There was no difference in any of the secondary outcomes (percentage of valid data points, percentage of time saturation below target, and so on) between the two groups in both pulse oximeters. Masimo sensor readings displayed a higher mean oxygen saturation (mean difference of 2.85, p=0.001) and lower percentage of time saturation below 94% (mean difference of -27.8, p=0.001) than Nellcor in both groups. There was no difference in any of the outcomes in babies receiving phototherapy (n=21). CONCLUSION: In this study, shielding the pulse oximeter sensor from ambient light or phototherapy light did not yield faster data acquisition or better data quality. TRIAL REGISTRATION NUMBER: ISRCTN10302534.


Assuntos
Iluminação , Oximetria/métodos , Estudos Cross-Over , Feminino , Humanos , Recém-Nascido , Masculino , Fototerapia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA